Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Large-scale penetration of Gulf Stream water onto the continental shelf north of Cape Hatteras

The presence of Gulf Stream water on the continental shelf as much as 60 km north of Cape Hatteras was observed during a hydrographic cruise in the summer of 1990. Gulf Stream water was concentrated at mid-depth between 10 and 30 m and penetrated the shelfbreak front which normally separates the shelf water from slope water and Gulf Stream water. Velocities of Gulf Stream water in the upper 110 m of the water column along the 1000 m isobath indicated a flow of 18 to 25 cm/s directed towards the northwest. Gulf Stream water on the shelf is considered to be associated with low values of fluorescence, transmissivity, and nutrient concentrations relative to adjacent shelf water.

Gawarkiewicz, Glen↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

SOFIA Observations of S106: Dynamics of the Warm Gas

Context The H II region/PDR/molecular cloud complex S106 is excited by a single O-star. The full extent of the warm and dense gas close to the star has not been mapped in spectrally resolved high-J CO or [C II] lines, so the kinematics of the warm. partially ionized gas, are unknown. Whether the prominent dark lane bisecting the hourglass-shaped nebula is due solely to the shadow cast by a small disk around the exciting star or also to extinction in high column foreground gas was an open question until now. Aims. To disentangle the morphology and kinematics of warm neutral and ionized gas close to the star, study their relation to the bulk of the molecular gas. and to investigate the nature of the dark lane. Methods. We use the heterodyne receiver GREAT on board SOFIA to observe velocity resolved spectral lines of [C II] and CO 11 yields 10 in comparison with so far unpublished submm continuum data at 350 micron (8HARC-Il) and complementary molecular line data. Results. The high angular and spectral resolution observations show a very complex morphology and kinematics of the inner S106 region, with many different components at different excitation conditions contributing to the observed emission. The [C II] lines are found to be bright and very broad. tracing high velocity gas close to the interface of molecular cloud and H II region. CO 11 yields 10 emission is more confined.. both spatially and in velocity, to the immediate surroundings of S 106 IR showing the presence of warm, high density (clumpy) gas. Our high angular resolution submm continuum observations rule out the scenario where the dark lane separating the two lobes is due solely to the shadow cast by a small disk close to the star. The lane is clearly seen also as warm, high column density gas at the boundary of the molecular cloud and H II region.

Simon, R.↗

Aircraft Measurements of BrO, IO, Glyoxal, NO2, H2O, O2-O2 and Aerosol Extinction Profiles in the Tropics: Comparison with Aircraft-/Ship-Based in Situ and Lidar Measurements

Tropospheric chemistry of halogens and organic carbon over tropical oceans modifies ozone and atmospheric aerosols, yet atmospheric models remain largely untested for lack of vertically resolved measurements of bromine monoxide (BrO), iodine monoxide (IO) and small oxygenated hydrocarbons like glyoxal (CHOCHO) in the tropical troposphere. BrO, IO, glyoxal, nitrogen dioxide (NO2), water vapor (H2O) and O2-O2 collision complexes (O4/ were measured by the University of Colorado Airborne Multi-AXis Differential Optical Absorption Spectroscopy (CU AMAXDOAS) instrument, aerosol extinction by high spectral resolution lidar (HSRL), in situ aerosol size distributions by an ultra high sensitivity aerosol spectrometer (UHSAS) and in situ H2O by vertical-cavity surface-emitting laser (VCSEL) hygrometer. Data are presented from two research flights (RF12, RF17) aboard the National Science Foundation/ National Center for Atmospheric Research Gulfstream V aircraft over the tropical Eastern Pacific Ocean (tEPO) as part of the "Tropical Ocean tRoposphere Exchange of Reactive halogens and Oxygenated hydrocarbons" (TORERO) project (January/February 2012). We assess the accuracy of O4 slant column density (SCD) measurements in the presence and absence of aerosols. Our O4-inferred aerosol extinction profiles at 477 nm agree within 6% with HSRL in the boundary layer and closely resemble the renormalized profile shape of Mie calculations constrained by UHSAS at low (sub-Rayleigh) aerosol extinction in the free troposphere. CU AMAX-DOAS provides a flexible choice of geometry, which we exploit to minimize the SCD in the reference spectrum (SCDREF, maximize signal-to-noise ratio) and to test the robustness of BrO, IO and glyoxal differential SCDs. The RF12 case study was conducted in pristine marine and free tropospheric air. The RF17 case study was conducted above the NOAA RV Ka'imimoana (TORERO cruise, KA-12-01) and provides independent validation data from ship-based in situ cavity-enhanced DOAS and MAX-DOAS. Inside the marine boundary layer (MBL) no BrO was detected (smaller than 0.5 pptv), and 0.2-0.55 pptv IO and 32-36 pptv glyoxal were observed. The near-surface concentrations agree within 30% (IO) and 10% (glyoxal) between ship and air-craft. The BrO concentration strongly increased with altitude to 3.0 pptv at 14.5 km (RF12, 9.1 to 8.6 deg N; 101.2 to 97.4 deg W). At 14.5 km, 5-10 pptv NO2 agree with model predictions and demonstrate good control over separating tropospheric from stratospheric absorbers (NO2 and BrO). Our profile retrievals have 12-20 degrees of freedom (DoF) and up to 500m vertical resolution. The tropospheric BrO vertical column density (VCD) was 1.5 x 10(exp 13) molec cm(exp -2) (RF12) and at least 0.5 x 10(exp 13) molec cm(exp -2) (RF17, 0- 10 km, lower limit). Tropospheric IO VCDs correspond to 2.1 x 10(exp 12) molec cm(exp -2) (RF12) and 2.5 x 10(exp 12) molec cm(exp -2) (RF17) and glyoxal VCDs of 2.6 x 10(exp 14) molec cm(exp -2) (RF12) and 2.7 x 10(exp 14) molec cm(exp -2) (RF17). Surprisingly, essentially all BrO as well as the dominant IO and glyoxal VCD fraction was located above 2 km (IO: 58 plus or minus 5 %, 0.1-0.2 pptv; glyoxal: 52 plus or minus 5 %, 3-20 pptv). To our knowledge there are no previous vertically resolved measurements of BrO and glyoxal from aircraft in the tropical free troposphere. The atmospheric implications are briefly discussed. Future studies are necessary to better understand the sources and impacts of free tropospheric halogens and oxygenated hydrocarbons on tropospheric ozone, aerosols, mercury oxidation and the oxidation capacity of the atmosphere.

Volkamer, R.↗

Methods for separating isotopes from a sample of fission products

Systems and methods for efficient, effective, and safe separation and isolation of multiple isotopes (e.g., Mo, Zr, Ba, Sr, Te, and lanthanide isotopes) from fission products includes use of a plurality of chromatography columns, each containing a chromatographic resin formulated to target one or more particular isotopes. The system is operable in a “series” configuration to load the multiple columns by a single pass of the sample. Then, the system may be transitioned (e.g., using valves) to a “parallel” configuration in which multiple columns of the system may be operated simultaneously to elute targeted isotopes. Additional parallel operations of the columns, using different eluent compositions, may be used to elute different targeted isotopes. The system may be reconditioned in preparation for a subsequent sample.

Snow, Mathew S.↗

Systems for separating isotopes from a sample of fission products

Systems and methods for efficient, effective, and safe separation and isolation of multiple isotopes (e.g., Mo, Zr, Ba, Sr, Te, and lanthanide isotopes) from fission products includes use of a plurality of chromatography columns, each containing a chromatographic resin formulated to target one or more particular isotopes. The system is operable in a “series” configuration to load the multiple columns by a single pass of the sample. Then, the system may be transitioned (e.g., using valves) to a “parallel” configuration in which multiple columns of the system may be operated simultaneously to elute targeted isotopes. Additional parallel operations of the columns, using different eluent compositions, may be used to elute different targeted isotopes. The system may be reconditioned in preparation for a subsequent sample.

Snow, Mathew S.↗

Simulation of DWPF Chemical Process Cell Using a Reaction Calorimeter

The Defense Waste Processing Facility (DWPF) converts liquid radioactive waste into glass using a Sludge Receipt Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in addition to other processes. The SRAT and SME processes can be simulated on a small-scale using the Mettler-Toledo Reaction Calorimeter (RC1). This equipment is able to automate the execution and monitoring of experiments involving nonradioactive chemical simulants. During the chemical processing of sludge in the SRAT process, foam begins to form and can foam over the reaction vessel. The current antifoam used at DWPF creates a risk of increased flammability and has a limited pH range. Usually, mercury is circulated back into the reaction vessel during the SRAT process, making it difficult to remove. To combat foam over, novel antifoams will be tested during the boil-up process using the RC1. To improve mercury extraction, 3D-printed coalescer columns will be tested within the Mercury Water Wash Tank (MWWT) of the RC1. Testing of Simulant Sludge Batch 6 (SB6) was performed to ensure: the sludge would form a stable foam at boiling during full SRAT/SME runs; the antifoam would reduce the amount of foam within the vessel The sludge and a Precipitate Reactor Feed Tank (PRFT) simulant with monosodium titanate (MST) were mixed separately, combined, and then heated to boiling. As shown below, the antifoam used was able to eliminate the foam within the vessel, as expected. The FormLabs Form2 3D Printer can be used to create roughly 3-inch tall and 1-inch diameter columns from clear and ceramic resins. The columns will utilize chemical and physical forces to draw the mercury out of a condensed offgas stream leaving the RC1 reaction vessel. These columns will be tested during full SRAT/SME runs on the basis of how well they are able to collect elemental mercury. In preparation for full-scale runs, the RC1 equipment was assembled onto a custom table and tested with water runs. The software used to control automation, iControl, has a user-friendly interface that allows the experiment to be altered as needed. An example of the data recorded during an experimental run is represented in Figure 1 below. Water runs were utilized as a way to prove if the RC1 system was functioning in the following areas: Boil-up rates, Chemical additions using pumps, Temperature readings, Balance readings, Probe readings, Offgas system, Agitation. Future Plans: Five novel antifoams will be tested during full SRAT/SME runs. The most effective antifoam will be utilized in DWPF's Chemical Process Cell. The design of the Mercury Extraction Coalescer can be further manipulated to increase the extraction of not only elemental mercury, but other heavy metals in environmental remediation processes as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗

Lead-acid battery

A sealed, low maintenance battery (10, 100) is formed of a casing (14, 102) having a sealed lid (12, 104) enclosing cell compartments (22, 110) formed by walls (24, 132). The cells comprise a stack (26) of horizontally disposed negative active plates (30) and positive active plates (28) interspersed with porous, resilient separator sheets (30). Each plate has a set of evenly spaced tigs (40, 41) disposed on one side thereof; like polarity tigs being disposed on one side and opposite polarity tigs on the other. Columns of tigs are electrically and mechanically joined by vertical bus bars (46). The bus bars contain outwardly projecting arms (56) of opposite polarity which are electrically joined at each partition wall (24) to electrically connect the cells in series. The stack is compressed by biasing means such as resilient pad (58) attached to the lid or by joining the tigs (52) to the post (48) at a distance less than the thickness of the mat (124). The end bus bars (46) are joined to straps (60, 62) which connect to the terminals (16, 18). The negative plates contain more capacity than the positive plates and the starved electrolyte imbibed in the separator sheets permits pressurized operation during which oxygen diffuses through the separator sheet to the negative plate where it recombines. Excess pressure is relieved through the vent and pressure relief valve (20).

Edwards, Dean B.↗

Rapid recovery of At-211 by extraction chromatography

The near quantitative separation, purification, and recovery of 211 At has been demonstrated through an extraction chromatography process which utilizes porous beads impregnated with 3-octanone, resulting in an elution yield of 92–95%. Moreover, the rapid nature of this process, <20 min, was achieved after dissolution of a Bi metal target in HNO 3 following retrieval from the beamline after α-particle bombardment. The solution was directly loaded onto the column with no volume or acidity adjustment. The column was washed with HNO 3 and H 2 O, and 211 At was eluted with ethanol, collecting roughly 87–93% in 1 mL. This process of recovering high purity 211 At, in near quantitative yields, represents a significant advance in At separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical processes for recovery and purification of high-purity uranium-234 from aged plutonium-238

This work describes a streamlined approach to the recovery and purification of 234 U from aged 238 Pu. Key modifications to conventional techniques are described that result in an efficient uranium and plutonium separation process that successfully produced tens of grams of ultrahigh purity 234 U at Oak Ridge National Laboratory. A new processing scheme was developed using an anion exchange column run in a cycling mode with HNO 3 media as the primary uranium purification process. This was followed with a uranyl peroxide precipitation step to purify and solidify the uranium before conversion to U 3 O 8 . Both the traditional uranyl peroxide precipitation method and a new cascade uranyl peroxide precipitation process were used for final purification of the 234 U.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Absorption lines in the spectrum of the quasar Markarian 132.

Wavelengths and profiles of several absorption lines in the spectrum of the quasar Markarian 132, obtained with the aid of an integrating television sensor, are presented. An attempt is made to derive column densities and internal Doppler velocities by fitting theoretical Voigt profiles to the observed spectra. C IV lines show that the absorption must occur in at least two separate clouds with a relative velocity of 160 km/sec.

Morton, D. C.↗

Sensitivity Limits of Space-Based Interferometric Gravitational Wave Observatories from the Solar Wind

Space-based interferometric gravitational wave instruments such as the ESA/NASA Laser Interferometer Space Antenna (LISA) observe gravitational waves by measuring changes in the light travel time between widely separated spacecraft. One potential noise source for these instruments is interaction with the solar wind, in particular the free electrons in the interplanetary plasma. Variations in the integrated column density of free electrons along the laser links will lead to time-of-flight delays which directly compete with signals produced by gravitational waves. In this paper we present a simplified model of the solar plasma relevant for this problem, anchor key parameters of our model using data from the NASA Wind/solar wind experiment instrument, and derive estimates for the effect in the LISA measurement. We find that under normal solar conditions, the gravitational wave sensitivity limit from the free-electron effect is smaller than other noise sources that are expected to limit LISA’s sensitivity.

Oliver Jennrich↗

Quantitative separation of tetralin hydroperoxide from its decomposition products by high performance liquid chromatography

A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.

Worstell, J. H.↗

HEAO 1 A-2 low-energy detector X-ray spectra of the Cygnus Loop

The Cygnus Loop supernova remnant was observed by the A-2 low-energy detector (LED) proportional counters on the HEAO 1 satellite. Recent improvements to the non-X-ray background rejection and detector response simulation have allowed production of the most accurate spectra of the Cygnus Loop to date. Three separate regions of the Cygnus Loop were observed. Single-temperature, Raymond-Smith models are inadequate to describe the spectra, but two component model fits are good. Temperature, column density, and emission measure variations across the Cygnus Loop are found. These results are interpreted and compared with previous work.

Leahy, D. A.↗

Adaptive Pore Opening to Form Tailored Adsorption Sites in a Cooperatively Flexible Framework Enables Record Inverse Propane/Propylene Separation

A proposed low-energy alternative to the separation of alkanes from alkenes by energy-intensive cryogenic distillation is separation by porous adsorbents. Unfortunately, most adsorbents preferentially take up the desired, high-value major component alkene, requiring frequent regeneration. Adsorbents with inverse selectivity for the minor component alkane would enable the direct production of purified, reagent-grade alkene, greatly reducing global energy consumption. However, such materials are exceedingly rare, especially for propane/propylene separation. Here, we report that through adaptive and spontaneous pore size and shape adaptation to optimize an ensemble of weak noncovalent interactions, the structurally responsive metal-organic framework CdIF-13 (sod-Cd(benzimidazolate) 2 ) exhibits inverse selectivity for propane over propylene with record-setting separation performance under industrially relevant temperature, pressure, and mixture conditions. Powder synchrotron X-ray diffraction measurements combined with first-principles calculations yield atomic-scale insight and reveal the induced fit mechanism of adsorbate-specific pore adaptation and ensemble interactions between ligands and adsorbates. Dynamic column breakthrough measurements confirm that CdIF-13 displays selectivity under mixed-component conditions of varying ratios, with a record measured selectivity factor of α ≈ 3 at 95:5 propylene:propane at 298 K and 1 bar. When sequenced with a low-cost rigid adsorbent, we demonstrated the direct purification of propylene under ambient conditions. In conclusion, this combined atomic-level structural characterization and performance testing firmly establishes how cooperatively flexible materials can be capable of unprecedented separation factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of silver($\mathrm{I}$) ion reduction on the selectivity of olefins, paraffins, and aromatic compounds by gas chromatographic stationary phases consisting of silver($\mathrm{I}$) salts in ionic liquids

We report the olefin/paraffin selectivity offered by ionic liquid (IL) stationary phases can be enhanced through the addition of silver(I) ion, which is well-known to undergo selective complexation with unsaturated compounds. However, such stationary phases often suffer from the loss of chromatographic selectivity as silver(I) ion can be reduced to elemental silver. To maintain the separation performance of silver(I) ion/IL stationary phases, an understanding of factors and conditions that promote the reduction of silver(I) ion is needed. In this study, capillary gas chromatography columns featuring a stationary phase consisting of the 1-decyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 10 MIM + ][NTf 2 - ]) IL impregnated with [Ag + ][NTf 2 - ] were examined to investigate the effects of temperature, hydrogen content in exposure gas stream, and time of heating/exposure events on olefin selectivity. Retention factors of representative analytes, such as C 6 olefins and paraffins as well as aromatic compounds, were measured after subjecting the columns to the aforementioned conditions, followed by an evaluation of selectivity factors over time. Selectivity factors of olefins and aromatic compounds were observed to decrease significantly when the stationary phases were heated to temperatures higher than 110°C as well as being subjected to mixed gas streams containing greater than 50 mol% of hydrogen. As constant column heating temperatures were applied under exposure gas mixtures containing hydrogen and nitrogen, a gradual decrease in analyte selectivity factors was observed under prolonged periods of time. However, application of a ternary gas mixture comprised of 25/50/25 mol% hydrogen/nitrogen/methane resulted in an increase in the 3-hexyne/cis-2-hexene selectivity when measured at 120°C for 60 h, due to a smaller decrease in the retention factor of 3-hexyne compared to cis-2-hexene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The interstellar medium near the sun - The line of sight to lambda Scorpii

Copernicus satellite spectrometric observations are used to determine column densities and ionization structure in the local interstellar medium in the line of sight to lambda Sco. Three, or possibly four, regions are identified by physical properties or velocity separations in the UV absorption line profiles, including a region with a temperature near 200,000 K containing O VI lines, one or two H II regions, and an H I region which may also contain S III and C III. Element abundances are tabulated, and abundances in the H I region are shown to have a depletion pattern similar to that for the line of sight to zeta Oph.

York, D. G.↗