Search NASA⌕ Search

SEARCH · Search NASA

Results for “condition based monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

An LSTM Deep Learning Network for ¿Background Radiation Prediction

Determination of appropriate background radiation is important in any measurement application. Environmental radiation monitors and monitors used to assess dose to individuals outside of controlled areas are particularly susceptible to changes in readings due to fluctuations in the environmental conditions. These fluctuations (e.g. radon progeny concentrations) lead to changes in the detector response in the actual radiation environment, and they need to be taken into account when extracting the net operational doses. Work has been ongoing to apply advances in Deep Learning and Artificial Intelligence to account for changes in detector responses based on environmental parameters; in particular, a Long-Short Term Memory (LSTM) Deep Learning architecture has been utilized to incorporate time-series data into a prediction model. In this work, we present the current status of the project to predict radiation measurements based on meteorological conditions and air packet trajectories extracted using the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT4) model.

Degtiarenko, Pavel↗

Shock tube/laser absorption measurement of the rate constant of the reaction: H 2 O 2 + CO 2 2OH + CO 2

We address the role of the linear mixing rule in the kinetics of the H 2 O 2 decomposition system by reporting the rate constant for H 2 O 2 + M = 2OH + M (M = Ar and CO 2 ) in the temperature range of 1087-1234 K at low pressures in a mixture of 20% CO 2 in Argon. The reaction rate constant was inferred from H 2 O concentrations monitored by using a laser-absorption spectroscopy-based water diagnostic. To the best of our knowledge, this is the first measurement of the rate constant of this reaction in a mixture to be reported in literature. A significant discrepancy was found between the rate constants derived using the traditional linear mixing rule and the reduced pressure linear mixing rule. Furthermore, this discrepancy can have serious implications on the predictive accuracy of these kinetic models, especially under conditions relevant to the operation of supercritical CO 2 (sCO 2 ) power cycles that rely on oxy-fuel combustion in a working fluid comprised almost entirely of CO 2 .

20 FOSSIL-FUELED POWER PLANTS↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

The EGS Collab Project – Stimulations at Two Depths

The EGS Collab project, supported by the US Department of Energy, is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory to address challenges in implementing enhanced geothermal systems (EGS). Data and observations from the field tests are compared to simulations to understand processes and build confidence in numerical modeling of the processes. We have completed Experiment 1 (of 3), which examined hydraulic fracturing in a well-characterized underground fractured phyllite test bed at a depth of approximately 1.5 km at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. Testbed characterization included fracture mapping, borehole acoustic and optical televiewers, full waveform sonic, conductivity, resistivity, temperature, campaign p- and s-wave investigations and electrical resistance tomography. Borehole geophysical techniques including passive seismic, continuous active source seismic monitoring, electrical resistance tomography, fiber-based distributed strain, distributed temperature, and distributed acoustic monitoring, were used to carefully monitor stimulation events and flow tests. More than a dozen stimulations and nearly one year of flow tests were performed. Quality data and detailed observations were collected and analyzed during stimulation and water flow tests using ambient temperature and chilled water. We achieved adaptive control of the tests using real-time monitoring and rapid dissemination of data and near-real-time simulation. More detailed numerical simulation was performed to answer key experimental design questions, forecast fracture propagation trajectories and extents, and analyze and evaluate results. Data are freely available from the Geothermal Data Repository. Experiment 2 examines the potential for hydraulic shearing in amphibolite at a depth of about 1.25 km at SURF. This site has a different set of stress and fracture conditions than Experiment 1. The Experiment 2 testbed consists of nine subhorizontal boreholes configured in two fans of two boreholes which surround the testbed and contain grouted-in electrical resistance tomography, seismic sensors, active seismic sources and distributed fiber sensors. A “five-spot” set of test wells that extends from a custom mined alcove includes an injection well and four production/monitoring wells. The testbed was characterized geophysically and hydrologically, and three stimulations have been performed using the Step-Rate Injection Method for Fracture In-Situ Properties (SIMFIP) tool to measure strains, and a new strain quantifying tool (downhole robotic strain analysis tool -DORSA) was deployed in a monitoring hole during stimulation. Real-time data were broadcast during stimulations to allow real-time response to arising issues.

EGS Collab, Enhanced Geothermal Systems, EGS, fiel↗

Research on Deformation Law of Deep Foundation Pit of Station in Core Region of Saturated Soft Loess Based on Monitoring

Saturated soft loess has a large pore structure, high compressibility, low strength, fluid plastic state, and poor engineering properties. It is still one of the key problems that engineering needs to solve. In order to study the influence of deep foundation pit excavation in the saturated soft loess area on the deformation of foundation pits, the deformation laws of ground settlement, enclosure structure, and supporting axial force were clarified based on the field tests on the deformation characteristics of deep foundation pits in areas with the high-water level in saturated soft loess, combined with geological conditions and on-site construction procedures. The results indicate the following: water supply and construction process were found to be the main factor in changing the surface settlement curve of deep foundation pits in saturated soft loess; increasing the construction speed of the pit bottom floor, inverted braces, floor frame beams, and sidewall frame beams to close the structure, which is conducive to restraining the deformation of the continuous underground wall and foundation pits in similar areas. In the initial stage of support layout, the axial force of steel support tends to increase too fast or even exceed the standard control value. Therefore, a reasonable preadding axial force is an effective means to control the deformation of the continuous underground wall and the axial force of the steel support. The current research results may provide a reference for constructing deep foundation pits in similar areas.

Wang, Xueyan↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

A study on computational fluid dynamics modeling of a refrigerated container for COVID-19 vaccine distribution with experimental validation

A key issue with the distribution of vaccines to prevent COVID-19 is the temperature level required during transport, storage, and distribution. Typical refrigerated transport containers can provide a temperature-controlled environment down to -30 °C. However, the Pfizer vaccine must be carefully transported and stored under a lower temperature between -80 °C and -60 °C. One way to provide the required temperature is to pack the vaccine vials into small packages containing dry ice. Dry ice sublimates from a solid to a gas, which limits the allowable transport duration. This can be mitigated by transporting in a -30 °C refrigerated container. Moreover, because the dry ice will sublimate and thereby release CO 2 gas into the transport container, monitoring the CO 2 concentration within the refrigerated container is also essential. In the present work, a 3D computational fluid dynamics model was developed based on a commercially available refrigerated container and validated with experimental data. The airflow, temperature distribution, and CO 2 concentration within the container were obtained from the simulations. The modeling results can provide guidance on preparing experimental setups, thus saving time and lowering cost, and also provide insight into safety precautions needed to avoid hazardous conditions associated with the release of CO 2 during vaccine distribution.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding the Polymorphism of Cobalt Nanoparticles Formed in Electrodeposition–An In Situ XRD Study

An advanced synchrotron-based in situ X-ray diffraction (XRD) technique is successfully developed and employed to track and monitor the formation and phase selection of cobalt (Co) in electrodeposition in real time and verify DFT computational results. The impacts of a number of controlling factors including the pH of the electrolyte and deposition overpotential are systematically studied. The results show that the yielded phase of the electrodeposited Co is controlled by both thermodynamics and kinetics. The low pH low overpotential condition favors the formation of the thermodynamically stable fcc phase. While the high pH high overpotential condition promotes the formation of the metastable hcp phase. The experimental results agree well with the nanometric phase diagram computed with DFT. Layer-by-layer alternative stacking of fcc-hcp polymorphic phases can be facilely fabricated by just varying the overpotential. This work not only offers an effective means to control the phase of electroplating of Co but also presents a new approach to reveal the fundamental insights of the formation of metals under electrochemical reduction driving force.

36 MATERIALS SCIENCE↗

Technical Assessment of Off-Gas System Technologies for Potential Use in Molten Salt Reactors

Molten salt reactors (MSRs) are a class of Generation IV advanced reactor technologies aimed to enhance and improve the safety, fuel utilization and cost-effectiveness of nuclear power generation. MSR concepts are based on using a molten salt mixture as a primary nuclear reactor coolant, while the fuel can be either directly dissolved in the coolant (i.e., fluid-fueled) or can be in a separate solid form (i.e., salt-cooled solid-fueled). MSRs can be operated in either thermal or fast neutron spectra, as simple fissile convertors, or breeder reactors (e.g., utilizing both fissile and fertile fuels), as well as accelerator-driven sub-critical reactors or transuranic element burners. Operation of MSRs will necessitate management and treatment of the off-gas streams released to the headspace of the reactor where, in some designs, a cover gas can be circulated to remove certain fission products and maintain an inert atmosphere. An inert MSR cover gas swept over or sparged into the salt will confine radionuclides emerging from the free surface, including radioactive noble and non-noble gases, aerosols, and volatile species. The elements and compounds of these species will have a wide range of thermochemical and physical properties, some of which will decay to different products in the off-gas stream. Therefore, system components used to manage and treat MSR off-gas streams will need to be robust under dynamic reactor and chemistry conditions to support adequate reactor performance by managing the composition and species in the salt coolant and cover gas space. Off-gas system components would perform as a radionuclide boundary to the reactor vessel and a primary means for preventing radionuclide release; therefore, they are of high safety significance for MSR operations. This report reviews various technologies and materials for potential implementation in the design of an MSR off-gas system per a general conceptual framework. The reviewed technologies operate based on scrubbing, capture, delay, or separation of species in the off-gas stream. These include molten hydroxide scrubbers, solid sorbents, delay off-gas systems, particle traps, and cryogenic distillation. Since aspects of an off-gas system will be design-specific, the approach is to provide general discussions on attributes of these technologies and materials, including target off-gas stream species, operational parameters and conditions of importance to decontamination factors, implementation maturity, system component monitoring, potential off-normal conditions and considerations for waste products. The information aims to support the U.S. Nuclear Regulatory Commission in their safety evaluations for MSR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Robust Method to Identify Groundwater Affected By Redox Conditions at Los Alamos National Laboratory Legacy Cleanup Site - 20497

To facilitate the mission of the Department of Energy's (DoE's) Environmental Management Program at Los Alamos National Laboratory (LANL), a significant number of groundwater monitoring wells with depths ranging from 152-396 meter were completed for characterization and monitoring. Groundwater at Los Alamos tends to be oxygen saturated with very low concentrations of organic matter. Drilling fluids can introduce residual carbon causing an increase in microbial activity and local reducing conditions around the well, potentially impacting representativeness of groundwater data quality for redox sensitive constituents. We assert that the redox state of the wells can robustly be identified by aqueous solution concentrations of iron and manganese. An automated review process has been built into a computer-based data management system enabling an efficient screening process for identifying reducing conditions that are not caught using standard data-validation protocol, and ensures that important data quality issues are thoroughly identified and addressed in an efficient and timely manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coastal-Fog Microphysics Using In-Situ Observations and GOES-R Retrievals

Here, the objective of this work is to evaluate GOES-R based fog conditions occurred during the C-FOG (Toward Improving Coastal Fog Prediction) field campaign. C-FOG is designed to advance understanding of fog formation, development, and dissipation over coastal environments to improve its predictability. The project took place along coastlines and open water environments of Eastern Canada (Nova Scotia, NS and the Island of Newfoundland, NL) during August-October of 2018 where environmental conditions play an important role for late season’s fog formation. During the C-FOG field campaign, instruments were located at the Ferryland Supersite, NL, with 2 main sites, and five satellite sites, as well as on the Research Vessel (R/V) Hugh R. Sharp. Key measurement instruments included a Gondola carrying a CDP (cloud droplet probe) and a BCP (backscatter cloud probe) was used for measuring droplet spectra from 1-75 µm on the R/V. A LPM (laser precipitation monitor) with 100 µm-1 cm size range and an OPC (optical particle counter) with 0.3-17 µm at 16 spectral channels provided information for fog and drizzle discrimination. Remote sensing platforms (e.g. profiling microwave radiometer, PMWR), Ceilometer, Lidar), meteorological towers, tethered balloons, and GOES-R products (e.g. fog coverage and droplet size and liquid water path) were used to evaluate fog over horizontal and vertical dimensions. Results suggest that effective radius, phase, liquid water path, and liquid water content values obtained from GOES-R and PMWR were comparable to ground based in-situ observations. It is concluded that integration of observations and nowcasting products may help improve short term local fog predictions.

54 ENVIRONMENTAL SCIENCES↗

Subspace-Driven Learning for Anomaly Detection in Process Transients

Nuclear power plant (NPP) monitoring and diagnostic centers are actively investigating and implementing automated anomaly detection algorithms to help plants catch anomalies sooner, thereby preventing or reducing the duration of unexpected shutdowns. Current machine learning-based anomaly detection methods are expected to be highly effective during stable, full-power operations because NPPs typically operate as baseload power generators, meaning there are extensive operating data available from plant equipment. However, it is expected that anomaly detection methods will face significant challenges during transient conditions (i.e., when power output falls below full power) because plants only occasionally operate at these lower power levels, generating sparse transient operational data, and resulting in false alarms or missed detections. Here, to address this issue, transfer learning is used, which for this problem leverages knowledge (in the form of learned features) from stable, full-power operations to improve detection accuracy during transient conditions, even with limited data. In this effort, a novel subspace approach is developed to transfer a subset of the data features from full power operation to transients. This approach is validated through experiments using synthetic data and was found to outperform two baseline transfer learning approaches in anomaly detection performance across a range of amounts of transient data used in the training process.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accurate and Fast Anomaly Detection in Additive Composite-Based Manufacturing using Thermal Cameras

Today, large-scale additive manufacturing with plastics and composite materials requires continuous monitoring by experienced staff to prevent, detect and correct anomalous events affecting the performance of the printed part. We address the complexity of this demanding task by designing a camera-based anomaly detection system utilizing probabilistic principal component analysis (PPCA). This is a machine learning technique is trained with thermal images collected during normal operation of the large-scale printer (Cincinnati BAAM). This technique is advantageous for practical applications as there is no need to artificially introduce anomalous conditions into model training. During deployment, we challenge this model by introducing deliberate variations of the extruder speed. We reduce extrusion speed to a lower level, between 70 and 95% of the nominal value to collected test images. Our results show that images are easily identified as anomalous for extruder speeds at or below 85% of the nominal speed, meaning that an anomalous reduction of the material deposition rate can be detected within seconds of its onset. We show that our results are robust to (a) camera-to-camera variability and (b) print-to-print variability.

Pike, John [ORNL]↗

FRMAC Laboratory Analysis Manual Volume 1, Revision 0

The Federal Radiological Monitoring and Assessment Center (FRMAC) is an operational center, available on request by the Department of Homeland Security (DHS) to respond to nuclear and radiological incidents as described in the National Response Framework (NRF). Under the Federal Interagency Operational Plan for Response and Recovery’s Nuclear/Radiological Annex, the U.S. Department of Energy (DOE) has the responsibility to maintain the operational readiness of the FRMAC during the emergency phase of an event. FRMAC is initially established and managed by the Nuclear Emergency Support Team (NEST) and serves as an interagency operations center with representatives from various federal, state, and local radiological response organizations. The purpose of the FRMAC is to assist state, local, tribal, and territorial governments (SLTT) in their mission to protect the health and well-being of their citizens with: • Verified radiation measurements. • Interpretations of radiation distributions based on Environmental Protection Agency (EPA), Food and Drug Administration (FDA), or local Protective Action Guidelines (PAGs). • Characterization of overall radiological conditions. Once a declaration to respond to a radiological emergency has been made, the National Nuclear Security Administration (NNSA) Headquarters will coordinate the response in consultation with the cognizant NNSA Regional Coordinating Office (RCO). Each of the eight RCOs maintain a 24-hour response capability for radiological emergencies that may occur in states served by its region. When a FRMAC is established, it operates under the parameters of the Incident Command System (ICS), as defined in the National Incident Management Systems (NIMS) construct. The Consequence Management Home Team (CMHT) will be activated immediately during normal business hours (Pacific Time Zone), and within two hours otherwise. The Consequence Management Response Team (CMRT) is prepared for deployment within six hours after activation. Along with the assets, FRMAC provides an operational framework for coordinating of all federal off-site radiological monitoring and assessment activities during a response to a radiological emergency to support the coordinating agency and SLTT governments. Potential radiological emergencies that fall within FRMAC vary widely in terms of the area affected, the nature of the contamination, and the scope of the government’s response. Detonation of a nuclear device, accidental release of radiation from a nuclear power plant, and a terrorist threat are just a few of the many possible scenarios FRMAC must be prepared to address. Through all this, supporting the state, local, and tribal organizations in the protection of the public remains the primary goal of the federal response.

54 ENVIRONMENTAL SCIENCES↗

A Review of Online Monitoring within Used Nuclear Fuel Recycling Processes

The processing of used nuclear fuels and related materials is often complex and variable. The ability to quickly optimize conditions to the material being processed can aid in increasing efficiency and safety, but requires very quick determination of the conditions present in the feedstock, the process, and the product. Furthermore, accurate quantification of materials such as enriched uranium and plutonium aids in maintaining material accountancy and avoiding nuclear proliferation risks. Traditional analytical methods require process samples to be collected and analyzed in a laboratory, which often takes days to weeks. Online monitoring is suitable for collecting this information nearly instantaneously, enabling much faster optimization of the process or detection of material diversion. Online monitoring is also beneficial as it is typically based on robust and nondestructive analytical methods, so no material is removed as samples. This review examines online monitoring relevant to used nuclear fuel processing for the determination of both chemical and physical parameters. The chemical parameters include quantities such as concentration, isotopic composition, and speciation. These values are often well suited to spectroscopic or spectrometric measurements as they are fast, nondestructive, and easily implemented in an online manner. Physical quantities are often more varied and include temperature, pressure, tank fill levels, and others. Due to the specificity of these quantities, specialized instrumentation is often used. However, this instrumentation is often amendable to online monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring the Stability of Porous Coordination Cages during the Photoreduction of Porous Salt Thin Films

This study investigates the photochemical properties and stability of zirconium-based porous salts composed of coordination cages and redox-active polyoxometalates (POMs). While bulk porous salts demonstrated photoreduction confined to surface regions due to lim-ited light penetration and scattering effects, thin films of cage-POM assemblies were fabricated to address these challenges. These optically transparent films allowed access to the catalyst core, enabling enhanced photochemical characterization. Comparative studies revealed that the thin films exhibited superior photochemical activity and maintained porosity under optimized conditions, whereas bulk powders suffered from surface-limited photoreduction and cage decomposition. Furthermore, this work highlights the utility of thin films as a platform for studying and advancing the photochemical applications of porous salts.

Hoq, Jahidul [Indiana University, Bloomington, IN ↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗