Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Endocervical ultrasound applicator for integrated hyperthermia and HDR brachytherapy in the treatment of locally advanced cervical carcinoma

Purpose: The clinical success of hyperthermia adjunct to radiotherapy depends on adequate temperature elevation in the tumor with minimal temperature rise in organs at risk. Existing technologies for thermal treatment of the cervix have limited spatial control or rapid energy falloff. The objective of this work is to develop an endocervical applicator using a linear array of multisectored tubular ultrasound transducers to provide 3-D conformal, locally targeted hyperthermia concomitant to radiotherapy in the uterine cervix. The catheter-based device is integrated within a HDR brachytherapy applicator to facilitate sequential and potentially simultaneous heat and radiation delivery. Methods: Treatment planning images from 35 patients who underwent HDR brachytherapy for locally advanced cervical cancer were inspected to assess the dimensions of radiation clinical target volumes (CTVs) and gross tumor volumes (GTVs) surrounding the cervix and the proximity of organs at risk. Biothermal simulation was used to identify applicator and catheter material parameters to adequately heat the cervix with minimal thermal dose accumulation in nontargeted structures. A family of ultrasound applicators was fabricated with two to three tubular transducers operating at 6.6-7.4 MHz that are unsectored (360 deg.), bisectored (2x180 deg.), or trisectored (3x120 deg.) for control of energy deposition in angle and along the device length in order to satisfy anatomical constraints. The device is housed in a 6 mm diameter PET catheter with cooling water flow for endocervical implantation. Devices were characterized by measuring acoustic efficiencies, rotational acoustic intensity distributions, and rotational temperature distributions in phantom. Results: The CTV in HDR brachytherapy plans extends 20.5{+-}5.0 mm from the endocervical tandem with the rectum and bladder typically <8 mm from the target boundary. The GTV extends 19.4{+-}7.3 mm from the tandem. Simulations indicate that for 60 min treatments the applicator can heat to 41 deg. C and deliver >5EM{sub 43 Degree-Sign C} over 4-5 cm diameter with T{sub max}<45 deg. C and 1 kg m{sup -3} s{sup -1} blood perfusion. The 41 deg. C contour diameter is reduced to 3-4 cm at 3 kg m{sup -3} s{sup -1} perfusion. Differential power control to transducer elements and sectors demonstrates tailoring of heating along the device length and in angle. Sector cuts are associated with a 14-47 deg. acoustic dead zone, depending on cut width, resulting in a {approx}2-4 deg. C temperature reduction within the dead zone below T{sub max}. Dead zones can be oriented for thermal protection of the rectum and bladder. Fabricated devices have acoustic efficiencies of 33.4%-51.8% with acoustic output that is well collimated in length, reflects the sectoring strategy, and is strongly correlated with temperature distributions. Conclusions: A catheter-based ultrasound applicator was developed for endocervical implantation with locally targeted, 3-D conformal thermal delivery to the uterine cervix. Feasibility of heating clinically relevant target volumes was demonstrated with power control along the device length and in angle to treat the cervix with minimal thermal dose delivery to the rectum and bladder.

60 APPLIED LIFE SCIENCES↗

Standardizing Naming Conventions in Radiation Oncology

Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this nomenclature. Conclusions: Use of standardized naming conventions is important to facilitate comparison of dosimetry across patient datasets. The guidelines presented here will facilitate international acceptance across a wide range of efforts, including groups organizing clinical trials, Radiation Oncology Institute, Dutch Radiation Oncology Society, Integrating the Healthcare Enterprise, Radiation Oncology domain (IHE-RO), and Digital Imaging and Communication in Medicine (DICOM).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Auto-segmentation of normal and target structures in head and neck CT images: A feature-driven model-based approach

Purpose: Intensity modulated radiation therapy (IMRT) allows greater control over dose distribution, which leads to a decrease in radiation related toxicity. IMRT, however, requires precise and accurate delineation of the organs at risk and target volumes. Manual delineation is tedious and suffers from both interobserver and intraobserver variability. State of the art auto-segmentation methods are either atlas-based, model-based or hybrid however, robust fully automated segmentation is often difficult due to the insufficient discriminative information provided by standard medical imaging modalities for certain tissue types. In this paper, the authors present a fully automated hybrid approach which combines deformable registration with the model-based approach to accurately segment normal and target tissues from head and neck CT images. Methods: The segmentation process starts by using an average atlas to reliably identify salient landmarks in the patient image. The relationship between these landmarks and the reference dataset serves to guide a deformable registration algorithm, which allows for a close initialization of a set of organ-specific deformable models in the patient image, ensuring their robust adaptation to the boundaries of the structures. Finally, the models are automatically fine adjusted by our boundary refinement approach which attempts to model the uncertainty in model adaptation using a probabilistic mask. This uncertainty is subsequently resolved by voxel classification based on local low-level organ-specific features. Results: To quantitatively evaluate the method, they auto-segment several organs at risk and target tissues from 10 head and neck CT images. They compare the segmentations to the manual delineations outlined by the expert. The evaluation is carried out by estimating two common quantitative measures on 10 datasets: volume overlap fraction or the Dice similarity coefficient (DSC), and a geometrical metric, the median symmetric Hausdorff distance (HD), which is evaluated slice-wise. They achieve an average overlap of 93% for the mandible, 91% for the brainstem, 83% for the parotids, 83% for the submandibular glands, and 74% for the lymph node levels. Conclusions: Our automated segmentation framework is able to segment anatomy in the head and neck region with high accuracy within a clinically-acceptable segmentation time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-307: Peripheral Dose Comparison Between Static and Dynamic Jaw Tracking On a High Definition MLC System

Purpose: To investigate the effect of dynamic and static jaw tracking on patient peripheral doses. Materials and Methods: A patient plan with a large sacral metastasis (volume 800cm3, prescription 600cGyx5) was selected for this study. The plan was created using 2-field RapidArc with jaw tracking enabled (Eclipse, V11.0.31). These fields were then exported and edited in MATLAB with static jaw positions using the control point with the largest field size for each respective arc, but preserving the optimized leaf sequences for delivery. These fields were imported back into Eclipse for dose calculation and comparison and copied to a Rando phantom for delivery analysis. Points were chosen in the phantom at depth and on the phantom surface at locations outside the primary radiation field, at distances of 12cm, 20cm, and 30cm from the isocenter. Measurements were acquired with OSLDs placed at these positions in the phantom with both the dynamic and static jaw deliveries for comparison. Surface measurements included an additional 1cm bolus over the OSLDs to ensure electron equilibrium. Results: The static jaw deliveries resulted in cumulative jaw-defined field sizes of 17.3% and 17.4% greater area than the dynamic jaw deliveries for each arc. The static jaw plan resulted in very small differences in calculated dose in the treatment planning system ranging from 0–16cGy. The measured dose differences were larger than calculated, but the differences in absolute dose were small. The measured dose differences at depth (surface) between the two deliveries showed an increase for the static jaw delivery of 2.2%(11.4%), 15.6%(20.0%), and 12.7%(12.7%) for distances of 12cm, 20cm, and 30cm, respectively. Eclipse calculates a difference of 0–3.1% for all of these points. The largest absolute dose difference between all points was 6.2cGy. Conclusion: While we demonstrated larger than expected differences in peripheral dose, the absolute dose differences were small.

60 APPLIED LIFE SCIENCES↗

Sensor Development for Liquid Water Detection in Dry Storage Casks: FY 2023 Status

Modeling efforts were undertaken in fiscal year (FY) 2023 to evaluate the feasibility and capability for sensing of liquid water inside canister-based dry cask storage systems (DCSSs). The focus was on the development of full-scale finite element models (FEMs) of ultrasound propagation through DCSS canister components. For these initial investigations, simulation of the baseplate component was targeted, envisioning water collection at the bottom of a vertically oriented canister. The effects of internal canister components (i.e., fuel basket, fuel assemblies) on ultrasound propagation in the baseplate component were evaluated in these efforts. The environment inside a DCSS confinement is intended to be inert and free of water to prevent potential corrosion of used fuel cladding or other internal hardware. Spent fuel assemblies are dried, after storage in water pools, to make sure water has been removed from assembly cavities. However, there is some uncertainty about the amount of residual water potentially left behind in a DCSS after drying processes, because water can become trapped in cavities or other small crevices in the surfaces formed by the fuel cladding, fuel assemblies, and other internal hardware components. Considering the complex space- and time-dependent temperature profiles in DCSSs, water may be in a liquid or gas phase depending on its location in the cask and how long the cask has been in storage. Evacuating most water and oxidizing agents contained within a canister is recommended by NUREG-1536 (NRC 2010), which covers DCSSs. As summarized by Salazar et al. (2020), existing guidance typically relies on achievable vacuum pumping pressures sustained over a hold period as a signal of dryness and water removal. However, time series data about water removal from full-scale commercial drying procedures are lacking (Hanson and Alsaed 2019). A review of drying specifications from several vendors led to the conclusion that if the specifications are followed correctly, the residual moisture in DCSSs should present an insignificant risk of cladding degradation (Knoll and Gilbert 1987). A more recent analysis concluded that much larger quantities of residual water could remain in DCSSs, but the amount would still not be expected to lead to significant corrosion of fuel cladding or other internal components (Jung et al. 2013). Industry drying procedures are mostly prescriptive in nature, and operational issues arising during the process could result in incomplete drying. A summary of operational issues and potential negative effects of residual water is provided by Salazar et al. (2019). Experimental efforts are ongoing to validate the extent of water removal in a DCSS based on drying procedures used at nuclear power plants through well-designed investigations of drying process efficacy and water retention (Durbin et al. 2021; Pulido et al. 2022a, Pulido et al. 2022b). This has been approached by simulating limited portions of a DCSS internal volume and fuel assemblies. So far, these efforts have focused on the effects of potential water trapping in the dashpot region of control rod guide tubes but are expected to be expanded to include the effects of other internal hardware features and failed fuel rod cladding. A method for detection and measurement of liquid water (Meyer et al. 2022; Meyer et al. 2021), in tandem with the drying information gained through experimental investigations, provides comprehensive bases for understanding the internal conditions of DCSSs and provides technical information to support licensing decisions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Friction Stir Welding of Line-Pipe Steels

Friction stir welding (FSW) offers both economic and technical advantages over conventional fusion welding practices for welding line-pipe. For offshore line-pipe construction, the economic savings has been shown to be considerable, approaching a calculated 25%. Offshore pipe is relatively small diameter but heavy wall compared to onshore pipe. One concern is the ability to achieve consistent full weld penetration in an on-site offshore FSW operation, e.g., on a lay-barge. In addition, depending on the size and morphology of the unwelded zone, lack of penetration at the weld root can be difficult if not impossible to detect by conventional NDE methods. Thus, an approach to assure consistent full penetration via process control is required for offshore line-pipe construction using FSW. For offshore construction, an internal structural mandrel can be used offering the opportunity to use a sacrificial anvil FSW approach. With this approach, a small volume of sacrificial material can be inserted into the structural anvil. The FSW tool penetrates into the sacrificial anvil, beyond the inner diameter of the pipe wall, thus assuring full penetration. The sacrificial material is subsequently removed from the pipe inner wall. In the work presented herein, FSW studies were completed on both 6 mm and 12 mm wall thickness line-pipe. Lastly, post-FSW evaluations including radiography, root-bend tests, and metallography demonstrated the merits of the sacrificial anvil approach to achieve consistent full penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IMRT Reirradiation of Head and Neck Cancer-Disease Control and Morbidity Outcomes

Purpose: Institutional and cooperative group experience has demonstrated the feasibility of reirradiation for head and neck cancer. Limited data are available regarding the use of intensity-modulated radiotherapy (IMRT) for this indication. We reviewed our initial experience using IMRT for previously irradiated head and neck cancer patients. Methods and Materials: Records of 78 consecutive patients reirradiated with IMRT for head and neck cancer between 1999 and 2004 were reviewed; 74 cases were analyzed. Reirradiation was defined as any overlap between original and new radiation treatment volumes regardless of the time interval between initial and subsequent treatment. Severe reirradiation-related toxicity was defined as toxic events resulting in hospitalization, corrective surgery, or patient death. Longitudinal estimates of survival were calculated by Kaplan-Meier technique. Results: Twenty (27%) patients underwent salvage surgical resection and 36 (49%) patients received chemotherapy. Median follow-up from reirradiation was 25 months. Median time interval between initial radiation and reirradiation was 46 months. Median reirradiation dose was 60 Gy. Median lifetime radiation dose was 116.1 Gy. The 2-year overall survival and locoregional control rates were 58% and 64%, respectively. Severe reirradiation related toxicity occurred in 15 patients (20%); one treatment-related death was observed. Conclusions: The use of IMRT for reirradiation of recurrent or second primary head and neck cancers resulted in encouraging local control and survival. Reirradiation-related morbidity was significant, but may be less severe than previously published reports using conventional techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost Impacts of Risk-Based Methods for Defining AoR and PISC Duration of a CO 2 Storage Project Using NRAP Tools and FE/NETL CO 2 Saline Storage Cost Model

The purpose of this analysis is to assess the fiscal impact of using risk-based methods to define the area of review (AoR) and post-injection site care (PISC) duration for a geologic carbon dioxide (CO 2 ) storage project. The Office of Fossil Energy (FE)/National Energy Technology Laboratory (NETL) CO 2 Saline Storage Cost Model (“cost model”) was utilized to evaluate CO 2 storage economics in this study. The cost model is a widely used tool for evaluating CO 2 storage costs in geologic settings. It estimates costs for storage operations conducted under compliance to the United States Environmental Protection Agency (EPA) Underground Injection Control (UIC) Class VI regulations. This analysis evaluates and compares the costs of storage (on a first-year break-even dollar per tonne [2018$] basis) at the proposed FutureGen 2.0 site as a case study storage location by implementing different approaches to determine AoR and PISC given the prevailing geologic conditions and injection volume and duration considerations. The approaches include the use of 1) risk-based methods to define AoR and PISC duration, 2) an EPA-approved AoR and PISC documented in the FutureGen 2.0 UIC Class VI permit applications, and 3) cost model default settings that utilize uncertainty multipliers to estimate CO 2 plume and pressure front extent as part of AoR determination, as well as a 50-year PISC default. From all three sources, the AoR and PISC specified in the Class VI permit applications for FutureGen 2.0 were the largest and longest relative to the other two sources.

54 ENVIRONMENTAL SCIENCES↗

Plackett-Burman experimental design to facilitate syntactic foam development

The use of an eight-experiment Plackett–Burman method can assess six experimental variables and eight responses in a polysiloxane-glass microsphere syntactic foam. The approach aims to decrease the time required to develop a tunable polymer composite by identifying a reduced set of variables and responses suitable for future predictive modeling. The statistical design assesses the main effects of mixing process parameters, polymer matrix composition, microsphere density and volume loading, and the blending of two grades of microspheres, using a dummy factor in statistical calculations. Responses cover rheological, physical, thermal, and mechanical properties. The cure accelerator content of the polymer matrix and the volume loading of the microspheres have the largest effects on foam properties. These factors are the most suitable for controlling the gel point of the curing foam, and the density of the cured foam. The mixing parameters introduce widespread variability and therefore should be fixed at effective levels during follow-up testing. Some responses may require greater contrast in microsphere-related factors. As a result, compared to other possible statistical approaches, the run economy of the Plackett–Burman method makes it a valuable tool for rapidly characterizing new foams.

36 MATERIALS SCIENCE↗

Highly Efficient Training, Refinement, and Validation of a Knowledge-based Planning Quality-Control System for Radiation Therapy Clinical Trials

Purpose: To demonstrate an efficient method for training and validation of a knowledge-based planning (KBP) system as a radiation therapy clinical trial plan quality-control system. Methods and Materials: We analyzed 86 patients with stage IB through IVA cervical cancer treated with intensity modulated radiation therapy at 2 institutions according to the standards of the INTERTECC (International Evaluation of Radiotherapy Technology Effectiveness in Cervical Cancer, National Clinical Trials Network identifier: 01554397) protocol. The protocol used a planning target volume and 2 primary organs at risk: pelvic bone marrow (PBM) and bowel. Secondary organs at risk were rectum and bladder. Initial unfiltered dose-volume histogram (DVH) estimation models were trained using all 86 plans. Refined training sets were created by removing sub-optimal plans from the unfiltered sample, and DVH estimation models… and DVH estimation models were constructed by identifying 30 of 86 plans emphasizing PBM sparing (comparing protocol-specified dosimetric cutpoints V{sub 10} (percentage volume of PBM receiving at least 10 Gy dose) and V{sub 20} (percentage volume of PBM receiving at least 20 Gy dose) with unfiltered predictions) and another 30 of 86 plans emphasizing bowel sparing (comparing V{sub 40} (absolute volume of bowel receiving at least 40 Gy dose) and V{sub 45} (absolute volume of bowel receiving at least 45 Gy dose), 9 in common with the PBM set). To obtain deliverable KBP plans, refined models must inform patient-specific optimization objectives and/or priorities (an auto-planning “routine”). Four candidate routines emphasizing different tradeoffs were composed, and a script was developed to automatically re-plan multiple patients with each routine. After selection of the routine that best met protocol objectives in the 51-patient training sample (KBP{sub FINAL}), protocol-specific DVH metrics and normal tissue complication probability were compared for original versus KBP{sub FINAL} plans across the 35-patient validation set. Paired t tests were used to test differences between planning sets. Results: KBP{sub FINAL} plans outperformed manual planning across the validation set in all protocol-specific DVH cutpoints. The mean normal tissue complication probability for gastrointestinal toxicity was lower for KBP{sub FINAL} versus validation-set plans (48.7% vs 53.8%, P<.001). Similarly, the estimated mean white blood cell count nadir was higher (2.77 vs 2.49 k/mL, P<.001) with KBP{sub FINAL} plans, indicating lowered probability of hematologic toxicity. Conclusions: This work demonstrates that a KBP system can be efficiently trained and refined for use in radiation therapy clinical trials with minimal effort. This patient-specific plan quality control resulted in improvements on protocol-specific dosimetric endpoints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Thermal Storage on the Performance of a Wood Pellet-fired Residential Boiler

Interest in the direct use of biomass for thermal applications as a renewable technology is increasing as is also focus on air pollutant emissions from these sources and methods to minimize the impact. This work has focused on wood pellet-fired residential boilers, which are the cleanest fuel in this category. In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum. One common pellet boiler was tested at full load and also at the minimum load used in the U.S. certification testing (15%). In these tests the load was steady over the test period. Testing was also done with an emulated load profile for a home in Albany, N.Y. on a typical January, March, and April day. In this case the load imposed on the boiler varied hourly under computer control, based on the modeled load for the example case used. The boiler used has a nominal output of 25 kW and a common mixed hardwood/softwood commercial pellet was used. Moisture content was 3.77%. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements. The test results showed that the use of storage strongly reduces cycling rates under part load conditions. The transients which occur as these boilers cycle contribute to increased particulate emissions and reduced efficiency. The time period of a full cycle at a given load condition can be increased by increasing the storage tank volume and/or increasing the control differential range. It was shown that increasing the period strongly increased the measured efficiency and reduced the particulate emission (relative to the no storage case). The impact was most significant at the low load levels. Storage tank heat loss is shown to be a significant factor in thermal efficiency, particularly at low load. Different methods to measure this heat loss were explored. For one of the tanks evaluated the efficiency loss at the 15% load point was found to be as high as 7.9%. Where storage is used good insulation on the tank, insulation on the piping, and attention to fittings are recommended.

09 BIOMASS FUELS↗

In vivo study of breast carcinoma radiosensitization by targeting eIF4E

Highlights: Black-Right-Pointing-Pointer eIF4E is associated with the formation and progression for breast cancer. Black-Right-Pointing-Pointer pSecX-t4EBP1 can downregulated the expression of eIF4E in direct binding. Black-Right-Pointing-Pointer We transfected pSecX-t4EBP1 into a mouse xenograft model. Black-Right-Pointing-Pointer It can significantly inhibit tumor growth and enhance the radiosensitivity. Black-Right-Pointing-Pointer The possible mechanism is downregulation of HIF-1{alpha} expression. -- Abstract: Background: Eukaryotic initiation factor eIF4E, an important regulator of translation, plays a crucial role in the malignant transformation, progression and radioresistance of many human solid tumors. The overexpression of this gene has been associated with tumor formation in a wide range of human malignancies, including breast cancer. In the present study, we attempted to explore the use of eIF4E as a therapeutic target to enhance radiosensitivity for breast carcinomas in a xenograft BALB/C mice model. Materials and methods: Ninety female BALB/C mice transfected with EMT-6 cells were randomly divided into six groups: control, irradiation (IR), pSecX-t4EBP1, pSecX-t4EBP1 + irradiation, pSecX and pSecX + irradiation. At the end of the experiments, all mice were sacrificed, the xenografts were harvested to measure the tumor volume and mass, and the tumor inhibition rates were calculated. Apoptosis was detected with a flow cytometric assay. Immunohistochemistry was used to detect the expression of HIF-1{alpha}. Results: The xenografts in pSecX-t4EBP1 mice showed a significantly delayed growth and smaller tumor volume, with a higher tumor inhibition rate compared with the control and pSecX groups. A similar result was obtained in the pSecX-t4EBP1 + IR group compared with IR alone and pSecX + irradiation. The expression of HIF-1{alpha} in the tumor cells was significantly decreased, while the apoptosis index was much higher. Conclusions: pSecX-t4EBP1 can significantly inhibit tumor growth and enhance the radiosensitivity of breast carcinoma xenografts in BALB/C mice. This is possibly associated with the downregulation of HIF-1{alpha} expression, which suggests that pSecX-t4EBP1 may serve as an ideal molecular target for the radiosensitization of breast carcinoma.

60 APPLIED LIFE SCIENCES↗

Long-Term Heating to Improve Receiver Performance

The buildup of hydrogen in the heat transfer fluid (HTF) that circulates through components of parabolic trough power plants decreases receiver thermal efficiency, and ultimately, it decreases plant performance and electricity output. The generation and occurrence of hydrogen in the HTF provides the driving force for hydrogen to permeate from the HTF through the absorber tube wall and into the receiver annulus. Getters adsorb hydrogen from the annulus volume until they saturate and are no longer able to maintain low hydrogen pressure. The increase in hydrogen pressure within the annulus significantly degrades thermal performance of the receiver and decreases overall power-plant efficiency. NREL and Acciona Energy North America (Acciona) are developing a method to control the levels of dissolved hydrogen in the circulating HTF. The basic approach is to remove hydrogen from the expansion tanks of the HTF subsystem at a rate that maintains hydrogen in the circulating HTF to a target level. Full-plant steady-state models developed by the National Renewable Energy Laboratory (NREL) predict that if hydrogen is removed from the HTF within the expansion tanks, the HTF that circulates through the collector field remains essentially free of hydrogen until the HTF returns to the power block in the hot headers. One of the key findings of our modeling is the prediction that hydrogen will reverse-permeate out of the receiver annulus if dissolved hydrogen in the HTF is kept sufficiently low. To test this prediction, we performed extended heating of an in-service receiver that initially had high levels of hydrogen in its annulus. The heating was performed using NREL's receiver test stand. Results of our testing showed that receiver heat loss steadily decreased with daily heating, resulting in a corresponding improvement in receiver thermal efficiency.

14 SOLAR ENERGY↗

SU-E-J-190: Development of Abdominal Compression & Respiratory Guiding System Using Gas Pressure Sensor

Purpose: Abdominal compression is known to be effective but, often makes external-marker-based monitoring of breathing motion not feasible. In this study, we developed and evaluated a system that enables both abdominal compression and monitoring of residual abdominal motion simultaneously. The system can also provide visual-biofeedback capability. Methods: The system developed consists of a compression belt, an abdominal motion monitoring sensor (gas pressure sensor) and a visual biofeedback device. The compression belt was designed to be able to compress the frontal side of the abdomen. The pressure level of the belt is controlled by air volume and monitored in real time using the gas pressure sensor. The system displays not only the real-time monitoring curve but also a guiding respiration model (e.g., a breath hold or shallow breathing curve) simultaneously on the head mounted display to help patients keep their breathing pattern as consistent as possible. Three healthy volunteers were enrolled in this pilot study and respiratory signals (pressure variations) were obtained both with and without effective abdominal compression to investigate the feasibility of the developed system. Two guidance patterns, breath hold and shallow breathing, were tested. Results: All volunteers showed smaller abdominal motion with compression (about 40% amplitude reduction compared to without compression). However, the system was able to monitor residual abdominal motion for all volunteers. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed abdominal compression & respiratory guiding system was feasible for residual abdominal motion management. It is considered that the system can be used for a respiratory motion involved radiation therapy while maintaining the merit of abdominal compression. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-F-J-130: Margin Determination for Hypofractionated Partial Breast Irradiation

Purpose: To determine the Planning Target Volume (PTV) margin for Hypofractionated Partial Breast Irradiation (HPBI) using the van Herk formalism (M=2.5∑+0.7σ). HPBI is a novel technique intended to provide local control in breast cancer patients not eligible for surgical resection, using 40 Gy in 5 fractions prescribed to the gross disease. Methods: Setup uncertainties were quantified through retrospective analysis of cone-beam computed tomography (CBCT) data sets, collected prior to (prefraction) and after (postfraction) treatment delivery. During simulation and treatment, patients were immobilized using a wing board and an evacuated bag. Prefraction CBCT was rigidly registered to planning 4-dimensional computed tomography (4DCT) using the chest wall and tumor, and translational couch shifts were applied as needed. This clinical workflow was faithfully reproduced in Pinnacle (Philips Medical Systems) to yield residual setup and intrafractional error through translational shifts and rigid registrations (ribs and sternum) of prefraction CBCT to 4DCT and postfraction CBCT to prefraction CBCT, respectively. All ten patients included in this investigation were medically inoperable; the median age was 84 (range, 52–100) years. Results: Systematic (and random) setup uncertainties (in mm) detected for the left-right, craniocaudal and anteroposterior directions were 0.4 (1.5), 0.8 (1.8) and 0.4 (1.0); net uncertainty was determined to be 0.7 (1.5). Rotations >2° in any axis occurred on 8/72 (11.1%) registrations. Conclusion: Preliminary results suggest a non-uniform setup margin (in mm) of 2.2, 3.3 and 1.7 for the left-right, craniocaudal and anteroposterior directions is required for HPBI, given its immobilization techniques and online setup verification protocol. This investigation is ongoing, though published results from similar studies are consistent with the above findings. Determination of margins in breast radiotherapy is a paradigm shift, but a necessary step in moving towards hypofractionated regiments, which may ultimately redefine the standard of care for this select patient population.

60 APPLIED LIFE SCIENCES↗

Hitting the target: fragment screening with acoustic in situ co-crystallization of proteins plus fragment libraries on pin-mounted data-collection micromeshes

A method is presented for screening fragment libraries using acoustic droplet ejection to co-crystallize proteins and chemicals directly on micromeshes with as little as 2.5 nl of each component. This method was used to identify previously unreported fragments that bind to lysozyme, thermolysin, and trypsin. Acoustic droplet ejection (ADE) is a powerful technology that supports crystallographic applications such as growing, improving and manipulating protein crystals. A fragment-screening strategy is described that uses ADE to co-crystallize proteins with fragment libraries directly on MiTeGen MicroMeshes. Co-crystallization trials can be prepared rapidly and economically. The high speed of specimen preparation and the low consumption of fragment and protein allow the use of individual rather than pooled fragments. The Echo 550 liquid-handling instrument (Labcyte Inc., Sunnyvale, California, USA) generates droplets with accurate trajectories, which allows multiple co-crystallization experiments to be discretely positioned on a single data-collection micromesh. This accuracy also allows all components to be transferred through small apertures. Consequently, the crystallization tray is in equilibrium with the reservoir before, during and after the transfer of protein, precipitant and fragment to the micromesh on which crystallization will occur. This strict control of the specimen environment means that the crystallography experiments remain identical as the working volumes are decreased from the few microlitres level to the few nanolitres level. Using this system, lysozyme, thermolysin, trypsin and stachydrine demethylase crystals were co-crystallized with a small 33-compound mini-library to search for fragment hits. This technology pushes towards a much faster, more automated and more flexible strategy for structure-based drug discovery using as little as 2.5 nl of each major component.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new method for the experimental heating of intact soil profiles for application to climate change experiments

Advanced facilities are needed to evaluate the response of complex ecosystems to projected unique climate conditions not observable in the context of current natural variation or through the use of climate gradients. A next-generation, experimental system for simulating future belowground temperature increases was conceived, simulated, constructed and tested in a temperate deciduous forest in Oak Ridge, Tennessee, USA. The new system uses low-wattage, 3-m deep, circumferentially-installed heaters surrounding a defined soil volume to both add the necessary energy to support a set-point soil temperature differential within the treatment area and to add exterior energy inputs equal to that which might be lost from lateral heat conduction. This approach, which is designed to work in conjunction with aboveground heated chambers, requires only two control positions, (1) aboveground air temperatures at 1 m and (2) belowground temperatures at 0.8 m. The approach is capable of achieving in situ target temperature differentials in the tested range of +4.0 0.5 C for soils to a measured depth of -2 m located within the aboveground boundary for air heating. These differentials were sustained throughout 2009, and both diurnal and seasonal cycles at all soil depths were retained using this simple heating approach. Measured mean energy inputs required to sustain the target heating level of +4 C over the 7.1 m2 target area were substantial: 21.1 kW h d-1 m-2 for aboveground heating but 16 times lower for belowground heaters at 1.3 kW h d-1 m-2. Observations of soil CO2 efflux from the surface of the target soil volumes showed CO2 losses throughout 2009 that were elevated above the temperature response curve for control CO2 losses at levels greater than have been reported in previous soil warming studies. Stimulation of biological activity of previously undisturbed deep-soil carbon stocks is the expected source. Long-term research programs may be able to apply similar experimental systems to address uncertainties in process-level responses of microbial, plant, and animal communities in whole, intact ecosystems using this new heating method that capture expected future warming and temperature dynamics throughout the soil profile.

54 ENVIRONMENTAL SCIENCES↗

Decline of Cosmetic Outcomes Following Accelerated Partial Breast Irradiation Using Intensity Modulated Radiation Therapy: Results of a Single-Institution Prospective Clinical Trial

Purpose: To report the final cosmetic results from a single-arm prospective clinical trial evaluating accelerated partial breast irradiation (APBI) using intensity modulated radiation therapy (IMRT) with active-breathing control (ABC). Methods and Materials: Women older than 40 with breast cancer stages 0-I who received breast-conserving surgery were enrolled in an institutional review board-approved prospective study evaluating APBI using IMRT administered with deep inspiration breath-hold. Patients received 38.5 Gy in 3.85-Gy fractions given twice daily over 5 consecutive days. The planning target volume was defined as the lumpectomy cavity with a 1.5-cm margin. Cosmesis was scored on a 4-category scale by the treating physician. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). We report the cosmetic and toxicity results at a median follow-up of 5 years. Results: A total of 34 patients were enrolled. Two patients were excluded because of fair baseline cosmesis. The trial was terminated early because fair/poor cosmesis developed in 7 of 32 women at a median follow-up of 2.5 years. At a median follow-up of 5 years, further decline in the cosmetic outcome was observed in 5 women. Cosmesis at the time of last assessment was 43.3% excellent, 30% good, 20% fair, and 6.7% poor. Fibrosis according to CTCAE at last assessment was 3.3% grade 2 toxicity and 0% grade 3 toxicity. There was no correlation of CTCAE grade 2 or greater fibrosis with cosmesis. The 5-year rate of local control was 97% for all 34 patients initially enrolled. Conclusions: In this prospective trial with 5-year median follow-up, we observed an excellent rate of tumor control using IMRT-planned APBI. Cosmetic outcomes, however, continued to decline, with 26.7% of women having a fair to poor cosmetic result. These results underscore the need for continued cosmetic assessment for patients treated with APBI by technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗