Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were significantly lower than supine in both original and uptake time-adjusted data across a range of index times (P < < 0.0001, Wilcoxon signed rank test). Before correcting for uptake time differences, Bland–Altman analyses revealed proportional bias between prone and supine measurements (SUV{sub peak} and SUV{sub max}) that increased with higher levels of FDG uptake. After uptake time correction, this bias was significantly reduced (P < 0.01). Significant prone-supine differences, with regard to the spatial distribution of lesions relative to isocenter, were observed between the two scan positions, but this was poorly correlated with the residual (uptake time-corrected) prone-supine SUV{sub peak} difference (P = 0.78). Conclusions: Quantitative 18F-FDG-PET/CT of the breast in the prone position is not deleteriously affected by the support device but yields SUV that is consistently lower than those obtained in the standard supine position. SUV differences between scans arising from FDG uptake time differences can be substantially reduced, but not removed entirely, with the current correction method. SUV from the two scan orientations is quantitatively different and should not be assumed equivalent or interchangeable within the same subject. These findings have clinical relevance in that they underscore the importance of patient positioning while scanning as a clinical variable that must be accounted for with longitudinal PET measurement, for example, in the assessment of treatment response.

60 APPLIED LIFE SCIENCES↗

Preferential diffusion in concentrated solid solution alloys: NiFe, NiCo and NiCoCr

In single-phase concentrated solid-solution alloys (CSAs), including high entropy alloys (HEAs), remarkable mechanical properties are exhibited, as well as extraordinary corrosion and radiation resistance compared to pure metals and dilute alloys. But, the mechanisms responsible for these properties are unknown in many cases. In this work, we employ ab initio molecular dynamics based on density functional theory to study the diffusion of interstitial atoms in Ni and Ni-based face-centered cubic CSAs including NiFe, NiCo and NiCoCr. We model the defect trajectories over >100 ps and estimate tracer diffusion coefficients, correlation factors and activation energies. Furthermore, we found that the diffusion mass transport in CSAs is not only slower than that in pure components, i.e. sluggish diffusion, but also chemically non-homogeneous. The results obtained here can be used in understanding and predicting the atomic segregation and phase separation in CSAs under irradiation conditions.

36 MATERIALS SCIENCE↗

WE-G-BRD-06: Volumetric Cine MRI (VC-MRI) Estimated Based On Prior Knowledge for On-Board Target Localization

Purpose: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. Methods: The end-expiration phase images of a 4D-MRI acquired during patient simulation are used as patient prior images. Principal component analysis (PCA) is used to extract 3 major respiratory deformation patterns from the Deformation Field Maps (DFMs) generated between end-expiration phase and all other phases. On-board 2D-cine MRI images are acquired in the axial view. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI at the end-expiration phase. The DFM is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by matching the corresponding 2D slice of the estimated VC-MRI with the acquired single 2D-cine MRI. The method was evaluated using both XCAT (a computerized patient model) simulation of lung cancer patients and MRI data from a real liver cancer patient. The 3D-MRI at every phase except end-expiration phase was used to simulate the ground-truth on-board VC-MRI at different instances, and the center-tumor slice was selected to simulate the on-board 2D-cine images. Results: Image subtraction of ground truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground truth with prior image. Excellent agreement between profiles was achieved. The normalized cross correlation coefficients between the estimated and ground-truth in the axial, coronal and sagittal views for each time step were >= 0.982, 0.905, 0.961 for XCAT data and >= 0.998, 0.911, 0.9541 for patient data. For XCAT data, the maximum-Volume-Percent-Difference between ground-truth and estimated tumor volumes was 1.6% and the maximum-Center-of-Mass-Shift was 0.9 mm. Conclusion: Preliminary studies demonstrated the feasibility to estimate real-time VC-MRI for on-board target localization before or during radiotherapy treatments. National Institutes of Health Grant No. R01-CA184173; Varian Medical System.

60 APPLIED LIFE SCIENCES↗

THE RELATIONSHIP BETWEEN {nu}{sub max} AND AGE t FROM ZAMS TO RGB-TIP FOR LOW-MASS STARS

Stellar age is an important quantity in astrophysics, which is useful for many fields both in the universe and galaxies. It cannot be determined by direct measurements, but can only be estimated or inferred. We attempt to find a useful indicator of stellar age, which is accurate from the zero-age main sequence to the tip of red giant branch for low-mass stars. Using the Yale Rotation and Evolution Code (YREC), a grid of stellar models has been constructed. Meanwhile, the frequency of maximum oscillations' power {nu}{sub max} and the large frequency separation {Delta}{nu} are calculated using the scaling relations. For the stars, the masses of which are from 0.8 M{sub Sun} to 2.8 M{sub Sun }, we can obtain the {nu}{sub max} and stellar age by combing the scaling relations with the four sets of grid models (YREC, Dotter et al., Marigo et al., and YY isochrones). We find that {nu}{sub max} is tightly correlated and decreases monotonically with the age of the star from the main sequence to the red giant evolutionary stages. Moreover, we find that the line shapes of the curves in the Age versus {nu}{sub max} diagram, which is plotted by the four sets of grid models, are consistent for red giants with masses from 1.1 M{sub Sun} to 2.8 M{sub Sun }. For red giants, the differences of correlation coefficients between Age and {nu}{sub max} for different grid models are minor and can be ignored. Interestingly, we find two peaks that correspond to the subgiants and bump of red giants in the Age versus {nu}{sub max} diagram. By general linear least-squares, we make the polynomial fitting and deduce the relationship between log(Age) and log({nu}{sub max}) in red giants' evolutionary state.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Lyβ auto-correlations and Lyα-Lyβ cross-correlations in BOSS Data Release 9

The Lyman-β forest refers to a region in the spectra of distant quasars that lies between the rest-frame Lyman-β and Lyman-γ emissions. The forest in this region is dominated by a combination of absorption due to resonant Lyα and Lyβ scattering. When considering the 1D Lyβ forest in addition to the 1D Lyα forest, the full statistical description of the data requires four 1D power spectra: Lyα and Lyβ auto-power spectra and the Lyα-Lyβ real and imaginary cross-power spectra. We describe how these can be measured using an optimal quadratic estimator that naturally disentangles Lyα and Lyβ contributions. Using a sample of approximately 60,000 quasar sight-lines from the BOSS Data Release 9, we make the measurement of the one-dimensional power spectrum of fluctuations due to the Lyβ resonant scattering. While we have not corrected our measurements for resolution damping of the power and other systematic effects carefully enough to use them for cosmological constraints, we can robustly conclude the following: i) Lyβ power spectrum and Lyα-Lyβ cross spectra are detected with high statistical significance; ii) the cross-correlation coefficient is ≈ 1 on large scales; iii) the Lyβ measurements are contaminated by the associated OVI absorption, which is analogous to the SiIII contamination of the Lyα forest. Measurements of the Lyβ forest will allow extension of the usable path-length for the Lyα measurements while allowing a better understanding of the physics of intergalactic medium and thus more robust cosmological constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting patient survival and stent patency, and stent patency showed statistically significant correlation with patient survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phenomenological Constitutive Modeling of High-Temperature Flow Behavior Incorporating Individual and Coupled Effects of Processing Parameters in Super-austenitic Stainless Steel

A novel constitutive model has been developed for predicting flow responses of super-austenitic stainless steel over a wide range of strains (0.05-0.6), temperatures (1173-1423 K) and strain rates (0.001-1 s{sup −1}). Further, the predictability of this new model has been compared with the existing Johnson–Cook (JC) and modified Zerilli–Armstrong (M-ZA) model. The JC model is not befitted for flow prediction as it is found to be exhibiting very high (~ 36%) average absolute error (δ) and low (~ 0.92) correlation coefficient (R). On the contrary, the M-ZA model has demonstrated relatively lower δ (~ 13%) and higher R (~ 0.96) for flow prediction. The incorporation of couplings of processing parameters in M-ZA model has led to exhibit better prediction than JC model. However, the flow analyses of the studied alloy have revealed the additional synergistic influences of strain and strain rate as well as strain, temperature, and strain rate apart from those considered in M-ZA model. Hence, the new phenomenological model has been formulated incorporating all the individual and synergistic effects of processing parameters and a ‘strain-shifting’ parameter. The proposed model predicted the flow behavior of the alloy with much better correlation and generalization than M-ZA model as substantiated by its lower δ (~ 7.9%) and higher R (~ 0.99) of prediction.

36 MATERIALS SCIENCE↗

Measuring the axial form factor of {sup 3}He using weak capture of polarized electrons

A low energy, high intensity polarized electron beam could enable the extraction of the A=3 weak axial form factors F{sub A} using the reaction →e+{sup 3}He→{sup 3}H+ν. These form factors have never been measured before. We discuss the feasibility of such an experiment using a small toroidal magnet and a radial low energy recoil detector to tag the recoil tritons. A moderately high intensity polarized electron beam (>500 μA) with beam energies between 50 - 150 MeV is necessary for the cross section measurement and to provides a free clean measurement of the background. Moreover, in addition to the cross section, by measuring the electron spin and recoil triton correlation coefficient it may be possible to search for second class currents and to extract the ratio of the axial to the vector form factor of the nucleon. Such novel electron scattering based measurements would have a completely different set of systematic uncertainties compared to polarized neutron beta decay, neutrino scattering and muon capture experiments which are typically used to extract the weak form-factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Urinary polycyclic aromatic hydrocarbon metabolites among 3-year-old children from Krakow, Poland

Highlights: • ETS, combustion of gas, coal or wood indoors were associated with OH-PAH levels. • The predominant metabolites in urine were OH-napthalenes and OH-fluorenes. • In biomonitoring of PAHs exposure, measuring only 1-OH-pyrene is insufficient. • Urinary OH-PAHs only modestly reflect high molecular weight PAHs exposures. Polycyclic aromatic hydrocarbons (PAHs) are widespread in the environment and can adversely affect human health. The aim of the present study is to describe the level of PAHs exposure in children living in Kraków, one of the most polluted cities in Poland, and to determine the relationship of urinary biomarkers with environmental PAHsexposure. Urinary monohydroxy metabolites (OH-PAHs) of 20 PAHs were assessed in 218 three-year old children, of which only 10 were present in nearly all the samples: monohydroxy metabolites of naphthalene, fluorene, phenantrene and pyrene. Of the metabolites analyzed, hydroxynaphthalenes were predominant and constituted almost 73% of total excreted OH-PAHs, while 1-OH-PYRene was the least abundant (2.3% of total OH-PAHs). All measured urinary OH-PAHs were statistically significantly correlated with each other (R = 0.165–0.880) but the highest correlation coefficients with other individual OH-PAHs and with total OH-PAHs were observed for 2-OH-FLUOR. Children exposed at home to environmental tobacco smoke (ETS) had higher concentrations of fluorene and pyrene urinary metabolites compared to those without ETS exposure; and those exposed to gas-based appliances used for cooking or heating water had higher levels of fluorene and phenanthrene metabolites than children not exposed. The use of coal, wood or oil for heating was associated with elevated levels of 1-OH-PYRene. Urinary PAHs metabolites only modestly reflect high molecular weight carcinogenic PAHs exposures such as those monitored in air in the present study. None of the measured PAHs metabolites was correlated with airborne PM{sub 2.5} and only two were slightly correlated with measured higher molecular mass airborne PAHs. The average concentrations of these specific metabolites in Polish children were much higher than observed in other pediatric populations living in developed countries. Our findings suggest that to capture various sources of PAHs, in addition to 1-OH-PYRene, biomonitoring of PAHs exposure should include 2-OH-NAP and 2-OH-FLUOR.

54 ENVIRONMENTAL SCIENCES↗

Direct phase selection of initial phases from single-wavelength anomalous dispersion (SAD) for the improvement of electron density and ab initio structure determination

A novel direct phase-selection method to select optimized phases from the ambiguous phases of a subset of reflections to replace the corresponding initial SAD phases has been developed. With the improved phases, the completeness of built residues of protein molecules is enhanced for efficient structure determination. Optimization of the initial phasing has been a decisive factor in the success of the subsequent electron-density modification, model building and structure determination of biological macromolecules using the single-wavelength anomalous dispersion (SAD) method. Two possible phase solutions (ϕ{sub 1} and ϕ{sub 2}) generated from two symmetric phase triangles in the Harker construction for the SAD method cause the well known phase ambiguity. A novel direct phase-selection method utilizing the θ{sub DS} list as a criterion to select optimized phases ϕ{sub am} from ϕ{sub 1} or ϕ{sub 2} of a subset of reflections with a high percentage of correct phases to replace the corresponding initial SAD phases ϕ{sub SAD} has been developed. Based on this work, reflections with an angle θ{sub DS} in the range 35–145° are selected for an optimized improvement, where θ{sub DS} is the angle between the initial phase ϕ{sub SAD} and a preliminary density-modification (DM) phase ϕ{sub DM}{sup NHL}. The results show that utilizing the additional direct phase-selection step prior to simple solvent flattening without phase combination using existing DM programs, such as RESOLVE or DM from CCP4, significantly improves the final phases in terms of increased correlation coefficients of electron-density maps and diminished mean phase errors. With the improved phases and density maps from the direct phase-selection method, the completeness of residues of protein molecules built with main chains and side chains is enhanced for efficient structure determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ensemble cure kinetics network (ECK-Net): A method to derive cure kinetics of thermosetting resin

This paper introduces an Ensemble Cure Kinetics Network (ECK-Net), a neural network (NN)–based framework for modeling the cure kinetics of thermosetting resins within a phenomenological context. ECK-Net replaces traditional analytic models, which require extensive chemical insight and multiple isothermal/non-isothermal experiments, with a data-driven surrogate that maps nonlinear relationships between temperature, degree of cure, and reaction rate from differential scanning calorimetry data. The proposed approach predicts input-dependent kinetic coefficients of a generalized nth-order reaction equation rather than reaction rates directly, enabling a single unified model to represent various epoxy systems without relying on iso-conversional analysis or predefined functional forms. To ensure robustness, multiple independently trained networks under different random initializations are blended through an ensemble strategy, effectively mitigating the stochastic variability inherent to neural networks. The framework is validated using experimental datasets from multiple resin systems, including aerospace-grade materials (Toray 3900-2, Cycom 5320-1, and Hexcel 8552) and a windmill-grade resin (RIMR 035c). The model accurately reproduces the temporal evolution of the degree of cure under manufacturers’ recommended cure cycles across all tested resins systems, yielding Pearson’s correlation coefficients of 0.992, 0.994, 0.993, 0.997, respectively. To demonstrate process-level applicability, the trained network was implemented within the Abaqus environment to simulate out-of-autoclave (OOA) curing process of the CFRP panel composed of Toray T830H-6K/3900-2D prepreg. The simulation results showed excellent agreement with experimental temperature response (maximum peak temperature, simulation: 189.6 °C, experiment: 188.5 °C) and the final degree of cure (simulation: 0.948, experiment: 0.960 ± 0.013), confirming ECK-Net’s capability as a reliable alternative to conventional cure kinetics modeling methods.

Composite curing↗

Analysis of Existing Data from a Distributed Acoustic Sensing Experiment at Garner Valley, California

In September 2013, an experiment using Distributed Acoustic Sensing (DAS) was conducted at Garner Valley, a test site of the University of California Santa Barbara (Lancelle et al., 2014). This submission includes noise cross-correlation functions (NCF) . Each file includes a NCF between two channels. The name of each channel denotes the distance in meters from starting point of the fiber-optic cable. The NCF is a time series data. The column 1 and 2 are time in seconds and dimensionless amplitude (cross correlation coefficient) respectively. Lancelle, C., N. Lord, H. Wang, D. Fratta, R. Nigbor, A. Chalari, R. Karaulanov, J. Baldwin, and E. Castongia (2014), Directivity and Sensitivity of Fiber-Optic Cable Measuring Ground Motion using a Distributed Acoustic Sensing Array (abstract # NS31C-3935), AGU Fall Meeting. https://agu.confex.com/agu/fm14/webprogram/Session1938.html The e-poster is available at: https://agu.confex.com/data/handout/agu/fm14/Paper_19828_handout_696_0.pdf

15 GEOTHERMAL ENERGY↗

Image encryption and watermarking combined dynamic chaotic hopping pattern with double random phase encoding DRPE

In modern civilization information, security is a crucial problem. Image encryption and watermarking can effectively protect information from unauthorized access. This paper introduces a new vigorous symmetric optical image encryption and watermarking technique. This technique depends on a novel dynamic delay chaotic hopping pattern (DDCHP) combined with double random phase encoding (DRPE). To get a robust watermark image, the plain image is first watermarked with a binary secret message using a new chaotic hopping pattern (CHP) and then encrypted using a DRPE system that is controlled by double random independent keys generated with double DDCHP. In this symmetric cryptosystem, three different chaotic maps are used to enlarge the key space of the proposed cryptosystem against brute-force attack and overcome the linearity and vulnerable of the classical DRPE. The system keys are hypersensitive and their initial parameters are selected carefully. Security scrutiny proves the efficiency of the suggested cryptosystem. Therefore, the obtained simulation results prove that the cryptosystem is robust enough against the known attacks, such as statistical attack (uniform histograms of different encrypted images, correlation coefficients between the plain and the encrypted image is as low as 5.46 × 10{sup −6}), differential attack (99.99% NPCR and 38.6% UACI), brute force attack (large enough key space), and entropy attack. Moreover, the robustness of the watermark (secret message) is proved due to the solidity of CHP. The proposed approach can be used in different implementations like secure military communications, e-finance, e-healthcare, authenticated multimedia broadcasting, etc.

97 MATHEMATICS AND COMPUTING↗

ON THE MAGNETIC AND ENERGY CHARACTERISTICS OF RECURRENT HOMOLOGOUS JETS FROM AN EMERGING FLUX

In this paper, we present the detailed analysis of recurrent homologous jets originating from an emerging negative magnetic flux at the edge of an active region. The observed jets show multithermal features. Their evolution shows high consistence with the characteristic parameters of the emerging flux, suggesting that with more free magnetic energy, the eruptions tend to be more violent, frequent, and blowout-like. The average temperature, average electron number density, and axial speed are found to be similar for different jets, indicating that they should have been formed by plasmas from similar origins. Statistical analysis of the jets and their footpoint region conditions reveals a strong positive relationship between the footpoint region total 131 Å intensity enhancement and jets’ length/width. Stronger linearly positive relationships also exist between the total intensity enhancement/thermal energy of the footpoint regions and jets’ mass/kinetic/thermal energy, with higher cross-correlation coefficients. All the above results together confirm the direct relationship between the magnetic reconnection and the jets and validate the important role of magnetic reconnection in transporting large amounts of free magnetic energy into jets. It is also suggested that there should be more free energy released during the magnetic reconnection of blowout than of standard jet events.

79 ASTRONOMY AND ASTROPHYSICS↗

Deriving the Intrahepatic Arteriovenous Shunt Rate from CT Images and Biochemical Data Instead of from Arterial Perfusion Scintigraphy in Hepatic Arterial Infusion Chemotherapy

The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual}; calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Serial crystallography with multi-stage merging of thousands of images

KAMO and BLEND provide particularly effective tools to automatically manage the merging of large numbers of data sets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending BLEND to support additional clustering options such as the use of more accurate cell distance metrics and the use of reflection-intensity correlation coefficients to infer `distances' among sets of reflections. This increases the sensitivity to differences in unit-cell parameters and allows clustering to assemble nearly complete data sets on the basis of intensity or amplitude differences. If the data sets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. When starting from incomplete data sets, one applies KAMO twice, first using unit-cell parameters. In this step, either the simple cell vector distance of the original BLEND or the more sensitive NCDist is used. This step tends to find clusters of sufficient size such that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between reflections with a common hkl to merge clusters in a way that is sensitive to structural differences that may not have perturbed the unit-cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into categories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent of one another, it should be possible to greatly improve the efficacy of data-clustering software by using a multi-stage partitioning strategy. Here, one possible approach to multi-stage data clustering is demonstrated. The strategy is to use unit-cell clustering until the merged data are sufficiently complete and then to use intensity-based clustering. Using this strategy, it is demonstrated that it is possible to accurately cluster data sets from crystals that have subtle differences.

36 MATERIALS SCIENCE↗

Thinking outside the box: effects of modes larger than the survey on matter power spectrum covariance

Accurate power spectrum (or correlation function) covariance matrices are a crucial requirement for cosmological parameter estimation from large scale structure surveys. In order to minimize reliance on computationally expensive mock catalogs, it is important to have a solid analytic understanding of the different components that make up a covariance matrix. Considering the matter power spectrum covariance matrix, it has recently been found that there is a potentially dominant effect on mildly non-linear scales due to power in modes of size equal to and larger than the survey volume. This beat coupling effect has been derived analytically in perturbation theory and while it has been tested with simulations, some questions remain unanswered. Moreover, there is an additional effect of these large modes, which has so far not been included in analytic studies, namely the effect on the estimated average density which enters the power spectrum estimate. In this article, we work out analytic, perturbation theory based expressions including both the beat coupling and this local average effect and we show that while, when isolated, beat coupling indeed causes large excess covariance in agreement with the literature, in a realistic scenario this is compensated almost entirely by the local average effect, leaving only ∼ 10% of the excess. We test our analytic expressions by comparison to a suite of large N-body simulations, using both full simulation boxes and subboxes thereof to study cases without beat coupling, with beat coupling and with both beat coupling and the local average effect. For the variances, we find excellent agreement with the analytic expressions for k < 0.2 hMpc{sup −1} at z = 0.5, while the correlation coefficients agree to beyond k = 0.4 hMpc{sup −1}. As expected, the range of agreement increases towards higher redshift and decreases slightly towards z = 0. We finish by including the large-mode effects in a full covariance matrix description for arbitrary survey geometry and confirming its validity using simulations. This may be useful as a stepping stone towards building an actual galaxy (or other tracer's) power spectrum covariance matrix.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of a Single Water Cerenkov Detector to Monitor Forbush Decreases

We describe a simple experimental setup to measure the rate of arrival of muons at the surface of the Earth by using a single water Cerenkov detector and home-made electronics. We find a strong anti-correlation between the muon rates averaged over one-hour periods and the atmospheric pressure, with a measured correlation coefficient of -0.67% per hPa. After applying this correction we achieve sufficient sensitivity to observe long term (hours) variations in the averaged muon rates which are greater than 2%. Forbush decreases as big as 4% have been observed with muon detectors located at similar magnetic rigidities compared to Morelia, therefore our experimental setup will detect Forbush decreases as soon as the Sun enters into a more active phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗