Search NASA⌕ Search

SEARCH · Search NASA

Results for “data logging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Thermal-Hydraulic Results for the Boiling Water Reactor Dry Cask Simulator.

The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both aboveground and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of this investigation was to produce validation-quality data that can be used to test the validity of the modeling presently used to determine cladding temperatures in modern vertical dry casks. These cladding temperatures are critical to evaluate cladding integrity throughout the storage cycle. To produce these data sets under well-controlled boundary conditions, the dry cask simulator (DCS) was built to study the thermal-hydraulic response of fuel under a variety of heat loads, internal vessel pressures, and external configurations. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplified interpretation of results. Two different arrangements of ducting were used to mimic conditions for aboveground and belowground storage configurations for vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured throughout the test assembly. The induced air mass flow rate was measured for both the aboveground and belowground configurations. In addition, the impact of cross-wind conditions on the belowground configuration was quantified. Over 40 unique data sets were collected and analyzed for these efforts. Fourteen data sets for the aboveground configuration were recorded for powers and internal pressures ranging from 0.5 to 5.0 kW and 0.3 to 800 kPa absolute, respectively. Similarly, fourteen data sets were logged for the belowground configuration starting at ambient conditions and concluding with thermal-hydraulic steady state. Over thirteen tests were conducted using a custom-built wind machine. The results documented in this report highlight a small, but representative, subset of the available data from this test series. This addition to the dry cask experimental database signifies a substantial addition of first-of-a-kind, high-fidelity transient and steady-state thermal-hydraulic data sets suitable for CFD model validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessing mechanical response of CO 2 storage into a depleted carbonate reef using a site-scale geomechanical model calibrated with field tests and InSAR monitoring data

Geomechanical risks of injection have raised concerns regarding secure CO 2 storage. In this work, a combined monitoring and modeling approach is used to assess the stress changes and surface uplift associated with CO 2 injection into a depleted carbonate reef of the Michigan basin. A site-scale geomechanical model is built by assigning mechanical properties of formations using well-log and experimental data. Gravity load is applied to the model to estimate the vertical component of stress as well as different lateral boundary displacement scenarios to estimate horizontal stresses. We used a poroelastic pressure-dependent model (instead of a linear elastic mechanical earth model) to calibrate initial stresses using hydraulic fracture test data measured at depleted reservoir status. Multi-phase fluid flow-geomechanical simulations are performed to estimate the poroelastic response during (1) primary depletion (2) field-scale CO 2 injection phase (3) a hypothetical forecast scenario in which well bottom hole pressure (BHP) reach 45000 KPa. The predicted surface uplift is less than 1 mm at the end of the field-scale CO 2 injection phase which is in good agreement with Interferometric Synthetic Aperture Radar (InSAR) uplift measurement. Although the InSAR data shows an insignificant uplift, hydromechanical modeling of injection shows that CO 2 injection still causes reservoir deformation emphasizing the role of carbonate overburden and reservoir formation mechanical properties and limited size of reef on diminishing the surface deformation. Modeling indicates poroelastic response of caprock matters to estimate uplift. The lower permeability of the top two layers provides additional barrier to large uplift. Also, history of subsidence due to production should be accounted to predict uplift due to a follow up injection correctly. This report shows the significance of combining a calibrated geomechanical model with field measured stresses and monitoring data to be used as a tool to ensure the safety of CO 2 storage.

42 ENGINEERING↗

Falcon: Visual analysis of large, irregularly sampled, and multivariate time series data in additive manufacturing

Flexible visual analysis of long, high-resolution, and irregularly sampled time series data from multiple sensor streams is a challenge in several domains. In the field of additive manufacturing, this capability is critical for realizing the full potential of large-scale 3D printers. Here, we propose a visual analytics approach that helps additive manufacturing researchers acquire a deep understanding of patterns in log and imagery data collected by 3D printers. Our specific goals include discovering patterns related to defects and system performance issues, optimizing build configurations to avoid defects, and increasing production efficiency. We introduce Falcon, a new visual analytics system that allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations, all with adjustable scale options. To illustrate the effectiveness of Falcon at providing thorough and efficient knowledge discovery, we present a practical case study involving experts in additive manufacturing and data from a large-scale 3D printer. The techniques described are applicable to the analysis of any quantitative time series, though the focus of this paper is on additive manufacturing.

97 MATHEMATICS AND COMPUTING↗

Mesozoic Deserts and CO2 Storage: The Glen Canyon Group, Utah, USA

For much of the Mesozoic an extensive desert environment extended across the Western Interior of the USA. These desert systems deposited vast dunefields, including one of the largest ergs preserved in the rock record. The Glen Canyon Group in Utah is a Triassic-Jurassic aged aeolian succession, consisting of thick, laterally extensive aeolian dune deposits, interdune lakes and oases, and dryland fluvial systems. These aeolian deposits have been identified as potential CO2 sequestration reservoirs. The Jurassic-aged Navajo Sandstone has been the subject of research into its potential as a CO2 reservoir, as well as naturally occurring CO2 seeps in the Green River area. It has excellent reservoir properties, consisting of thick sandstones with high porosity and permeability, and has industry data including well logs and core. It occurs in both outcrop and subcrop, allowing for comparison and sense checking of interpretations across small and large scales. The Triassic Wingate Sandstone has received much less attention, however it too is composed of thick aeolian dune deposits. Like the Navajo Sandstone, the Wingate Sandstone has industry data, and occurs in both outcrop and subcrop. Using extensive industry data which exists across Utah is an effective way to pivot from a hydrocarbon focus to CO2 injection, and so contribute to green energy and carbon neutral emission goals. Here we use historic industry data in conjunction with field work, to study the Navajo and Wingate Sandstones and their potential as CO2 reservoirs, in addition to increasing our understanding of lithologic and stratigraphic complexity in one of the most significant aeolian systems in the world.

Mahon, Elizabeth↗

Physical Properties and Gas Hydrate at a Near-Seafloor Thrust Fault, Hikurangi Margin, New Zealand

The Papaku Fault Zone, drilled at International Ocean Discovery Program (IODP) Site U1518, is an active splay fault in the frontal accretionary wedge of the Hikurangi Margin. In logging-while-drilling data, the 33-m-thick fault zone exhibits mixed modes of deformation associated with a trend of downward decreasing density, P-wave velocity, and resistivity. Methane hydrate is observed from ~30 to 585 m below seafloor (mbsf), including within and surrounding the fault zone. Hydrate accumulations are vertically discontinuous and occur throughout the entire logged section at low to moderate saturation in silty and sandy centimeter-thick layers. In this paper, we argue that the hydrate distribution implies that the methane is not sourced from fluid flow along the fault but instead by local diffusion. This, combined with geophysical observations and geochemical measurements from Site U1518, suggests that the fault is not a focused migration pathway for deeply sourced fluids and that the near-seafloor Papaku Fault Zone has little to no active fluid flow.

58 GEOSCIENCES↗

The Increasingly Complex Challenge of Gas Hydrate Reservoir Simulation

Gas hydrate reservoir simulation is a complex endeavor. Reliable simulation capability will allow the proper design of field tests and the interpretation of field test data that are necessary to advance the understanding of the response of gas hydrate reservoirs to production activities. Increasing appreciation of the complexity of gas hydrate reservoirs, as well as continued uncertainty in key petrophysical parameters, requires great care in the design of simulation studies. This report outlines select emerging issues that greatly impact the relevance of numerical simulation resulting, including reservoir heterogeneity, geomechanics, log and core data interpretation, grid size, and others.

Boswell, Ray↗

Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.

43 PARTICLE ACCELERATORS↗

Development of intelligent instruments with embedded HTTP servers for control and data acquisition in a cryogenic setup—The hardware, firmware, and software implementation

The power of Ethernet for control and automation technology is being largely understood by the automation industry in recent times. Ethernet with HTTP (Hypertext Transfer Protocol) is one of the most widely accepted communication standards today. Ethernet is best known for being able to control through internet from anywhere in the globe. The Ethernet interface with built-in on-chip embedded servers ensures global connections for crate-less model of control and data acquisition systems which have several advantages over traditional crate-based control architectures for slow applications. This architecture will completely eliminate the use of any extra PLC (Programmable Logic Controller) or similar control hardware in any automation network as the control functions are firmware coded inside intelligent meters itself. Here, we describe the indigenously built project of a cryogenic control system built for linear accelerator at Inter University Accelerator Centre, known as “CADS,” which stands for “Complete Automation of Distribution System.” CADS deals with complete hardware, firmware, and software implementation of the automated linac cryogenic distribution system using many Ethernet based embedded cryogenic instruments developed in-house. Each instrument works as an intelligent meter called device-server which has the control functions and control loops built inside the firmware itself. Dedicated meters with built-in servers were designed out of ARM (Acorn RISC (Reduced Instruction Set Computer) Machine) and ATMEL processors and COTS (Commercially Off-the-Shelf) SMD (Surface Mount Devices) components, with analog sensor front-end and a digital back-end web server implementing remote procedure call over HTTP for digital control and readout functions. At present, 24 instruments which run 58 embedded servers inside, each specific to a particular type of sensor-actuator combination for closed loop operations, are now deployed and distributed across control LAN (Local Area Network). A group of six categories of such instruments have been identified for all cryogenic applications required for linac operation which were designed to build this medium-scale cryogenic automation setup. These devices have special features like remote rebooters, daughter boards for PIDs (Proportional Integral Derivative), etc., to operate them remotely in radiation areas and also have emergency switches by which each device can be taken to emergency mode temporarily. Finally, all the data are monitored, logged, controlled, and analyzed online at a central control room which has a user-friendly control interface developed using LabVIEW{sup ®}. This paper discusses the overall hardware, firmware, software design, and implementation for the cryogenics setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Northwest Open Automated Demand Response Technology Demonstration Project

Lawrence Berkeley National Laboratory (LBNL) and the Demand Response Research Center (DRRC) performed a technology demonstration and evaluation for Bonneville Power Administration (BPA) in Seattle City Light's (SCL) service territory. This report summarizes the process and results of deploying open automated demand response (OpenADR) in Seattle area with winter morning peaking commercial buildings. The field tests were designed to evaluate the feasibility of deploying fully automated demand response (DR) in four to six sites in the winter and the savings from various building systems. The project started in November of 2008 and lasted 6 months. The methodology for the study included site recruitment, control strategy development, automation system deployment and enhancements, and evaluation of sites participation in DR test events. LBNL subcontracted McKinstry and Akuacom for this project. McKinstry assisted with recruitment, site survey collection, strategy development and overall participant and control vendor management. Akuacom established a new server and enhanced its operations to allow for scheduling winter morning day-of and day-ahead events. Each site signed a Memorandum of Agreement with SCL. SCL offered each site $3,000 for agreeing to participate in the study and an additional $1,000 for each event they participated. Each facility and their control vendor worked with LBNL and McKinstry to select and implement control strategies for DR and developed their automation based on the existing Internet connectivity and building control system. Once the DR strategies were programmed, McKinstry commissioned them before actual test events. McKinstry worked with LBNL to identify control points that can be archived at each facility. For each site LBNL collected meter data and trend logs from the energy management and control system. The communication system allowed the sites to receive day-ahead as well as day-of DR test event signals. Measurement of DR was conducted using three different baseline models for estimation peak load reductions. One was three-in-ten baseline, which is based on the site electricity consumption from 7 am to 10 am for the three days with the highest consumption of the previous ten business days. The second model, the LBNL outside air temperature (OAT) regression baseline model, is based on OAT data and site electricity consumption from the previous ten days, adjusted using weather regressions from the fifteen-minute electric load data during each DR test event for each site. A third baseline that simply averages the available load data was used for sites less with less than 10 days of historical meter data. The evaluation also included surveying sites regarding any problems or issues that arose during the DR test events. Question covered occupant comfort, control issues and other potential problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steel Creek, Pen Branch, and D-Area Watershed Stream Gauging Stations

A network of stream gauging systems were installed in the Steel Creek, Pen Branch, D-Area Discharge Canal, and the D006 Stream in support of the groundwater modeling efforts for the P-Area Groundwater Operable Unit (OU); Chemical, Metals, and Pesticides (CMP) Pits OU; and the D-Area Watershed, respectively. Each location is monitored by a MACE Floseries3 FloPro data logger and a MACE doppler ultrasonic area/velocity sensor. Each stream gauging system is powered by an internal 12-volt battery supplied by a solar panel with a trickle charger. Information collected by each data logger is logged internally and telecommunicated via a cellular network to an online server for real time analysis and monitoring. The MACE doppler ultrasonic area/velocity sensor can measure stream depth and velocities to give output values of flow rates, total flow, net flow, and volumes. The water depth is measured by a ceramic pressure transducer located on the top of the sensor. The velocity is measured by a continuous wave doppler sensor to give an average velocity across the whole stream profile. This report discusses the equipment and methods used to install continuous stream gauging stations and provides a summary of data collected through FY2025.

54 ENVIRONMENTAL SCIENCES↗

Autonomous Inversion of In Situ Deformation Measurement Data for Injection-Induced Stress Change

Geologic carbon storage (GCS) is likely to play a key part of the global effort to dramatically reduce CO2 emissions and perhaps even reduce atmospheric CO2 concentrations through carbon negative operations. A critical part of effort to commercialize and widely deploy this technology is developing the capability to rapidly assimilate real-time monitoring data into a form that will enable site operators to make decisions to manage the safe and efficient operations. Two of the risks associate with GCS are the risk of inducing fractures in the sealing formations that can create leakage pathways and the risk of inducing earthquakes of sufficient magnitude to cause public concern, property damage, or safety risks. To properly manage these risks the site operator needs to know the initial state of stress, the change in stress induced by injection, and the relationship between operational parameters such as injection rate and pressure and the change in stress. Current methods of estimating the change in stress require choosing the type of constitutive model and the model parameters based on core, log, and geophysical data during the characterization phase, with little feedback from operational observations to validate or refine these choices. These characterization methods interrogate the geologic formations using length scales, loading rates or magnitudes that are quite different from those encountered by the actual storage system. It is shown that errors in the assumed constitutive response, even when informed by laboratory tests on core samples, are likely to be common, large, and underestimate the magnitude of stress change caused by injection. Recent advances in borehole-based strain instruments and borehole and surface-based tilt and displacement instruments have now enabled monitoring of the deformation of the storage system throughout its operational lifespan. This data can enable validation and refinement of the knowledge of the geomechanical properties and state of the system, but brings with it a challenge to transform the raw data into actionable knowledge. We demonstrate a method that uses automatic differentiation and a finite-element based geomechanical model perform a gradient-based deterministic inversion of geomechanical monitoring data. This approach allows autonomous integration of the instrument data without the need for time consuming manual interpretation and selection of updated model parameters. Furthermore, only isotropic linear elasticity is considered in this paper, the approach presented is very flexible as to what type of geomechanical constitutive response can be used. The approach is easily adaptable to nonlinear physics-based constitutive models to account for common rock behaviors such as creep and plasticity. The approach also enables training of machine learning-based constitutive models by allowing back propagation of errors through the finite element calculations. This enables strongly enforcing known physics, such as conservation of momentum and continuity, while allowing data-driven models to learn the truly unknown physics such as the constitutive or petrophysical responses.

Burghardt, Jeffrey A.↗

Field Results from New Tensor Borehole Optical Fiber Strainmeter Installations in Oklahoma and Utah

The time evolving strain field contains a wealth of information that can be used to interpret subsurface behavior. For example, injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. We've previously demonstrated the feasibility of measuring the strain tensor at a depth of 30m caused by injection into a reservoir at 530m. The observed strain signals were interpreted using four independent analytic and numerical methods that resulted in estimates of the poroelastic properties and geometry of the reservoir that was consistent with data from well logs. However, studies like these are only possible if these deformations can be reliably measured. Years of lab and field work has culminated in the development of a novel borehole strainmeter capable of resolving multiple components of strain using embedded optical fibers configured as Michelson interferometers. It features four horizontal gauges separated by 45° to resolve the horizontal strain tensor as well as a vertical strain gauge and a sixth null component for state-of-health monitoring. The downhole sensing package also includes an open pipe through its center for grout circulation during single-trip deployments and a fully welded stainless steel exterior for robustness and longevity. These instruments have a resolution of 2x10-13 strain that can easily measure the solid earth tides. Preliminary data are available from four strainmeters in shale at our Oklahoma site and four in compacted sand and gravel in Utah. These are deployed from 40-60m, except one of the strainmeters in Oklahoma is deployed at 500m. The data include strains from the initial grout curing, comparisons to predicted earth tide models and in-situ calibration results, barometric pressure admittances and spectral analyses as well as signals from underground injections and surface waves from teleseismic events. Preliminary analyses indicate behavior consistent with other strainmeter deployments, and comparison to data from a Gladwin strainmeter at the Oklahoma site validate the performance of the new design. Analyses from a suite of six well tests at the Oklahoma site show for the first time how the strain tensor field varies with location during well testing.

DeWolf, Scott↗

SPE2 Far-field Seismic Data Quicklook

The purpose of this report is to provide a brief overview of the far-field seismic data collected by the array of instruments (Figures 1 and 2) deployed by the Source Physics experiment for shots 1 (roughly 100 kg TNT equivalent at a depth of 60 m) and shot 2, (roughly 2000 kg TNT equivalent at a depth of 45 m). 'Far-field' is taken to refer to instruments in the zone of purely elastic response at distances of 100 m or greater. The primary focus is data from the main instrument array and hence data from other groups is not considered. Infrasound data is not addressed nor any remote sensing data. Data processing was done at LLNL in parallel with the effort at UNR. Raw reftek data was sent via hard disk from NsTec. Reftek data was converted to SEGY and then to SAC format. Data files were renamed according to station and channel information. Reftek logs were reviewed. These data have been reviewed for consistency with the UNR data on the server. The primary goal was quality check and a summary is provided in Tables 1 and 2.

58 GEOSCIENCES↗

Ordovician-Cambrian Units: Hierarchical Evaluation of Geologic Carbon Storage Resource Estimates

The Indiana Geological and Water Survey (IGWS) led subtask 1.1 to assess the regional distribution and estimate the storage capacity of Ordovician-Cambrian stratigraphic units located within the partnership region. A comprehensive data set of wireline logs and petrophysical information was used to generate these interpretations. These data include core analysis for porosity and permeability, mercury injection capillary pressure (MICP), and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for three potential storage reservoirs(limestone and dolostone from the Upper Ordovician Trenton Limestone/Black River Group and equivalent units, the Middle Ordovician St. Peter Sandstone, and primary target reservoir rocks of the Lower Ordovician and Upper Cambrian Knox Supergroup and equivalent units) calculated using six methodologies: (1) a fixed value of porosity of 10 percent in all units evaluated; (2) a unique average porosity (per well) from wireline-derived porosity (neutron, sonic, and/or density porosity for each unit); (3) porosity values from core analysis; (4) a depth-dependent porosity model (Knox Supergroup only); (5) porosity based on a model based on petrophysical facies; and (6) SREs using National Energy Technology Laboratory’s CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN beta V2). All methods used the same values for thickness for each unit. However, the areal extent of each assessment was limited by the data available for each method. Estimated volumes were calculated in 1-by-1 kilometer grid cells and summarized as county and total stratigraphic unit volumes. The resultant SREs mass are displayed using boxplots, which allow for comparing data statistics (mean values and variability) between methods. Differences observed in SRE results from the six methods are mainly attributable to differences in the data and conceptual models used to interpret or estimate porosity in each method. Based on this systematic variability between methods, it is inferred that methods 1, 4, and 6 are best used for regional-scale reconnaissance estimates of storage capacity while methods 2, 3, and 5 are more appropriate for local scales where more data is required. All estimates are data-density dependent and different methods require different amounts of data for reasonable assessments. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Identification of blind geothermal resources in Surprise Valley, CA, using publicly available groundwater well water quality data

Geothermal resource exploration is generally limited to areas with surface expressions of thermal activity (fumaroles and hot springs), or relies on expensive geophysical exploration techniques. The hidden subsurface distribution of geothermal fluids has been identified using a free and publicly available water quality dataset from agricultural and domestic water wells in Surprise Valley, northeastern California. Thermally evolved waters in Surprise Valley have element ratios that vary in response to Ca carbonate and Mg silicate mineral precipitation, and have elevated total dissolved solids (TDS). The arid climate in Surprise Valley leads to surface water evaporation in a closed basin, producing high TDS Na-Cl-CO 3 -SO 4 brines in three ephemeral alkali lakes and in shallow groundwater under elevated soil CO 2 conditions. Evaporated fluids in Surprise Valley follow a chemical divide that leads to Ca carbonate and Mg silicate mineral precipitation. Plots of dissolved element ratios can be used to distinguish groundwater affected by evaporation from water affected by thermal water-rock interaction, however it is challenging to select components for plotting that best illustrate different fluid evolution mechanisms. Here, we use a principal component analysis of centered log-ratio transformed data, coupled with geochemical models of fluid evaporation and thermal mixing pathways, to identify components to plot that distinguish between groundwater samples influenced by evaporation from those influenced by thermal processes. We find that groundwater samples with a thermal signature come from wells that define a coherent, linear geographical distribution that closely matches the location of known and inferred faults. Finally, modification of the general approach employed here provides promise for identifying blind geothermal resources in other locations, by applying low-cost geochemical modeling and statistical techniques to areas where large groundwater quality geochemical datasets are available.

15 GEOTHERMAL ENERGY↗

MASK4 Test Campaign for Sandia WaveBot Device

This data and report details the findings from a wave tank test focused on production of useful work of a wave energy converter (WEC) device. The experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance. These data describe the "MASK4" wave tank test of the Sandia WaveBot device. The WaveBot device has been tested a number of times in different permutations at the US Navy's Maneuvering and Sea Keeping (MASK) basin. Each test in this series is referred to as MASK1, MASK2, etc. The WaveBot device was first tested in one degree of freedom (heave) in 2016. This MASK1 test focused primarily on system identification and modeling. After MASK1, major modifications were performed to improve the overall real-time control and measurement system, improve the heave drive train, and add surge and pitch degrees of freedom. The second set of testing, which was broken up in to two stages: MASK2A and MASK2B, focused on bench testing and closed-loop control performance as well as nonlinear modeling. MASK3 then focused on multi-input, multi-output modeling and control for maximization of electrical power. The attached report presents the results from MASK4, which focuses on detailed modeling of the power conversion chain and validation co-design principles by way of the introduction of a magnetic spring. The test log, report, and data from the MASK4 test of the WaveBot augmented with a tunable magnetic spring. Processing codes can be found at the Github link below.

16 TIDAL AND WAVE POWER↗

Bayesian and LASSO Regressions for Comparative Permeability Modeling of Sandstone Reservoirs

In this research, Bayesian model averaging (BMA) and least absolute shrinkage and selection operator regression (LASSO) algorithms were adopted for the core permeability modeling as a function of well log and core measurements. More specifically, the core permeability (dependent factor) was modeled given the well log and core data (independent variables) and then predicted in non-cored intervals of a well in a sandstone formation. The BMA is a stochastic linear modeling and a Bayesian parameter selection. Among 50 linear models generated as a function of the independent variables and depicted in Occam’s window, the best model of the highest posterior probability is determined. The best model has the optimal subset parameters that most influences the response factor. The core permeability modeling was again conducted using the LASSO algorithm, which adopts a completely different way of modeling and subset selection by using the penalized least-squared equation. Both BMA and LASSO resulted in a very accurate prediction of the core permeability by achieving perfect measured and calculated permeability matching. Matches for the two algorithms were quantified by computing the adjusted R-squared and root-mean-squared prediction error. In addition, results of the BMA and LASSO were compared to the conventional multiple linear regression (LM). The LASSO algorithm led to an accurate matching similar to LM, but slightly better than BMA. Therefore, both BMA and LASSO represent integrated procedures for accurate permeability estimation similar to conventional regression analysis.

58 GEOSCIENCES↗