Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Interpretation of Indications Generated by Small Welding Discontinuities in Ultrasonic Time of Flight Diffraction Technique

The article presents results of research on non-destructive ultrasonic time of flight diffraction technique TOFD and metallographic examinations of selected cross-sections of a MAG welded joint. The main objective was to compare the results of TOFD and metallographic examination at the locations where a large number of point-like indications, located on specific depths, have been detected on TOFD images and analyse the impact of this type of indication on results of a welded joint evaluation. Considered, that the indications have not exhibited separations between upper and lower diffraction signals, because of their small heights, measuring of height of indications in those cases was impossible. In all cases, the occurrence of discontinuities of 0.16–0.78 mm in height, in locations indicated by TOFD has been confirmed.

42 ENGINEERING↗

Theoretical interpretation of electron energy-loss spectroscopic images

In this paper, we discuss the theory of electron energy-loss spectroscopic images in scanning transmission electron microscopy. Three case studies are presented which have as common themes issues of inelastic scattering, coherence and image interpretation. The first is a state-by-state inelastic transitions analysis of a spectroscopic image which does not admit direct visual interpretation. The second compares theory and experiment for two-dimensional mapping. Finally, the third considers imaging in three dimensions via depth sectioning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Western Aphrodite Terra, tectonics, geology, and line-of-sight gravity

Aphrodite Terra is the largest area of high-standing topography on Venus, and isostatic considerations strongly suggest that this high topography is supported at least in part by thickened crust. Previous studies of line-of-sight gravity data from the Pioneer Venus Orbiter indicate rapidly changing apparent depths of compensation across Aphrodite Terra. Magellan imaging data provide the first detailed images of this region, and we are mapping the region along Pioneer Venus orbit 440 to investigate whether the changing apparent depths of compensation correlate with changes in surficial tectonics. Preliminary mapping of geological features on Magellan images along the path of Pioneer Venus orbit 440 do not indicate a first-order correlation among surface features and changes in the apparent depth of compensation of line-of-sight gravity data. The apparent depth of compensation appears to be most variable in regions dominated by tessera, but not all areas of tessera have distinct gravity signatures. There is a weak correlation among areas in which impact craters are relatively common and areas in which the observed and predicted gravity anomalies are poorly correlated.

Hays, John E.↗

The Athena Microscopic Imager Investigation

The Athena science payload on the Mars Exploration Rovers (MER) includes the Microscopic Imager (MI) [1]. The MI is a fixed-focus camera mounted on the end of an extendable instrument arm, the Instrument Deployment Device (IDD; see Figure 1).The MI was designed to acquire images at a spatial resolution of 30 microns/pixel over a broad spectral range (400 - 700 nm; see Table 1). Technically, the microscopic imager is not a microscope: it has a fixed magnification of 0.4 and is intended to produce images that simulate a geologist s view through a common hand lens. In photographers parlance, the system makes use of a macro lens. The MI uses the same electronics design as the other MER cameras [2, 3] but has optics that yield a field of view of 31 31 mm across a 1024 1024 pixel CCD image (Figure 2). The MI acquires images using only solar or skylightillumination of the target surface. A contact sensor is used to place the MI slightly closer to the target surface than its best focus distance (about 66 mm), allowing concave surfaces to be imaged in good focus. Because the MI has a relatively small depth of field (3 mm), a single MI image of a rough surface will contain both focused and unfocused areas. Coarse focusing will be achieved by moving the IDD away from a rock target after the contact sensor is activated. Multiple images taken at various distances will be acquired to ensure good focus on all parts of rough surfaces. By combining a set of images acquired in this way, a completely focused image can be assembled. Stereoscopic observations can be obtained by moving the MI laterally relative to its boresight. Estimates of the position and orientation of the MI for each acquired image will be stored in the rover computer and returned to Earth with the image data. The MI optics will be protected from the Martian environment by a retractable dust cover. The dust cover includes a Kapton window that is tinted orange to restrict the spectral bandpass to 500-700 nm, allowing color information to be obtained by taking images with the dust cover open and closed. The MI will image the same materials measured by other Athena instruments (including surfaces prepared by the Rock Abrasion Tool), as well as rock and soil targets of opportunity. Subsets of the full image array can be selected and/or pixels can be binned to reduce data volume. Image compression will be used to maximize the information contained in the data returned to Earth. The resulting MI data will place other MER instrument data in context and aid in petrologic and geologic interpretations of rocks and soils on Mars.

K E Herkenhoff↗

Collisional Grooming Models of the Kuiper Belt Dust Cloud

We modeled the three-dimensional structure of the Kuiper Belt (KB) dust cloud at four different dust production rates, incorporating both planet-dust interactions and grain-grain collisions using the collisional grooming algorithm. Simulated images of a model with a face-on optical depth of approximately 10 (exp -4) primarily show an azimuthally- symmetric ring at 40-47 AU in submillimeter and infrared wavelengths; this ring is associated with the cold classical KB. For models with lower optical depths (10 (exp -6) and 10 (exp-7)), synthetic infrared images show that the ring widens and a gap opens in the ring at the location of Neptune; this feature is caused by trapping of dust grains in Neptune's mean motion resonances. At low optical depths, a secondary ring also appears associated with the hole cleared in the center of the disk by Saturn. Our simulations, which incorporate 25 different grain sizes, illustrate that grain-grain collisions are important in sculpting today's KB dust, and probably other aspects of the solar system dust complex; collisions erase all signs of azimuthal asymmetry from the submillimeter image of the disk at every dust level we considered. The model images switch from being dominated by resonantly trapped small grains ("transport dominated") to being dominated by the birth ring ("collision dominated") when the optical depth reaches a critical value of r approximately v/c, where v is the local Keplerian speed.

Kuchner, Marc J.↗

2D/3D Visual Tracker for Rover Mast

A visual-tracker computer program controls an articulated mast on a Mars rover to keep a designated feature (a target) in view while the rover drives toward the target, avoiding obstacles. Several prior visual-tracker programs have been tested on rover platforms; most require very small and well-estimated motion between consecutive image frames a requirement that is not realistic for a rover on rough terrain. The present visual-tracker program is designed to handle large image motions that lead to significant changes in feature geometry and photometry between frames. When a point is selected in one of the images acquired from stereoscopic cameras on the mast, a stereo triangulation algorithm computes a three-dimensional (3D) location for the target. As the rover moves, its body-mounted cameras feed images to a visual-odometry algorithm, which tracks two-dimensional (2D) corner features and computes their old and new 3D locations. The algorithm rejects points, the 3D motions of which are inconsistent with a rigid-world constraint, and then computes the apparent change in the rover pose (i.e., translation and rotation). The mast pan and tilt angles needed to keep the target centered in the field-of-view of the cameras (thereby minimizing the area over which the 2D-tracking algorithm must operate) are computed from the estimated change in the rover pose, the 3D position of the target feature, and a model of kinematics of the mast. If the motion between the consecutive frames is still large (i.e., 3D tracking was unsuccessful), an adaptive view-based matching technique is applied to the new image. This technique uses correlation-based template matching, in which a feature template is scaled by the ratio between the depth in the original template and the depth of pixels in the new image. This is repeated over the entire search window and the best correlation results indicate the appropriate match. The program could be a core for building application programs for systems that require coordination of vision and robotic motion.

Bajracharya, Max↗

Smoothing-Based Relative Navigation and Coded Aperture Imaging

This project will develop an efficient smoothing software for incremental estimation of the relative poses and velocities between multiple, small spacecraft in a formation, and a small, long range depth sensor based on coded aperture imaging that is capable of identifying other spacecraft in the formation. The smoothing algorithm will obtain the maximum a posteriori estimate of the relative poses between the spacecraft by using all available sensor information in the spacecraft formation.This algorithm will be portable between different satellite platforms that possess different sensor suites and computational capabilities, and will be adaptable in the case that one or more satellites in the formation become inoperable. It will obtain a solution that will approach an exact solution, as opposed to one with linearization approximation that is typical of filtering algorithms. Thus, the algorithms developed and demonstrated as part of this program will enhance the applicability of small spacecraft to multi-platform operations, such as precisely aligned constellations and fractionated satellite systems.

Relative positioning↗

Limits on the Abundance and Burial Depth of Lunar Polar Ice

The Diviner imaging radiometer experiment aboard the Lunar Reconnaissance Orbiter has revealed that surface temperatures in parts of the lunar polar regions are among the lowest in the solar system. Moreover, modeling of these Diviner data using realistic thermal conductivity profiles for lunar regolith and topography-based illumination has been done, with surprising results. Large expanses of circum-polar terrain appear to have near-subsurface temperatures well below 110K, despite receiving episodic low-angle solar illumination [Paige et al., 2010]. These subsurface cold traps could provide areally extensive reservoirs of volatiles. Here we examine the limits to abundance and burial depth of putative volatiles, based on the signature they would create for orbital thermal and epithermal neutrons. Epithermals alone are not sufficient to break the abundance-depth ambiguity, while thermal neutrons provide an independent constraint on the problem. The subsurface cold traps are so large that even modest abundances, well below that inferred from LCROSS observations, would produce readily detectable signatures in the Lunar Prospector neutron spectrometer data [Colaprete et al., 2010]. Specifically, we forward-model the thermal and epithermal neutron leakage flux that would be observed for various ice concentrations, given the depth at which ice stability begins. The LCROSS results point to a water-equivalent hydrogen abundance (WEH) in excess of 10 wt%, when all hydrogenous species are added together (except for H2, detected by LAMP on LRO [Gladstone et al., 2010]). When such an ice abundance is placed in a layer below the stability depth of Paige et al., the epithermal and thermal neutron leakage fluxes are vastly reduced and very much at odds with orbital observations. So clearly an environment that is conducive to cold trapping is necessary but not sufficient for the presence of volatiles such as water. We present the limits on the abundances that are indeed consistent with orbital data. At the LCROSS impact site itself, the data are consistent with very high ice abundances at 50-100 cm depth. However, radar results rule out these high abundances.

Elphic, Richard C.↗

On the potential of long wavelength imaging radars for mapping vegetation types and woody biomass in tropical rain forests

In the tropical rain forests of Manu, in Peru, where forest biomass ranges from 4 kg/sq m in young forest succession up to 100 kg/sq m in old, undisturbed floodplain stands, the P-band polarimetric radar data gathered in June of 1993 by the AIRSAR (Airborne Synthetic Aperture Radar) instrument separate most major vegetation formations and also perform better than expected in estimating woody biomass. The worldwide need for large scale, updated biomass estimates, achieved with a uniformly applied method, as well as reliable maps of land cover, justifies a more in-depth exploration of long wavelength imaging radar applications for tropical forests inventories.

Rignot, Eric J.↗

PTT System Performance Evaluation in 3-D Imaging of AM Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for non-destructive evaluation (NDE) either during or post manufacturing. Known material flaws in AM include low density regions consisting of nonsintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This study investigates the capability of PTT in imaging several AM structures fabricated from Inconel 718 (IN718) feedstock. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of IN718 nozzle plate and a particle filter plate. The results demonstrate the capability of PTT in 3- D imaging of complex geometry AM structures. Further, increased resolution imaging is achieved compared to prior results using older FLIR SC4000 IR camera. In addition, preliminary studies were conducted on developing image processing algorithms for automated detection of flaws. Initial demonstrations are shown for segmentation of PTT images of flat bottom hole (FBH) specimens. Imaging of FBH specimens was described in a prior report. Intermediate results demonstrated in this report will be developed further in detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Internal structure of the San Jacinto fault zone at Jackass Flat from data recorded by a dense linear array

The internal structure of the Clark fault in the trifurcation area of the San Jacinto fault zone is imaged using seismograms recorded by a dense linear array (Jackass Flat, JF) crossing the surface trace of the fault and an adjacent array (TR) to the SW. Delay times between phase arrivals associated with ~3500 local earthquakes and nine teleseismic events are used to estimate velocity variations within the arrays. The teleseismic P waves travel faster beneath the TR than the JF array, in contrast to larger scale tomographic results. Statistical analysis of local P-wave delay times indicates that the entire JF array, with an aperture of ~400 m, is inside a low-velocity damage zone. This low-velocity zone is bounded on the NE side by a shallow bimaterial interface generating fault zone head waves, and it contains an inner zone of more intense damage generating fault zone trapped waves. The P-wave velocity contrast across the local bounding bimaterial interface is 10–15 per cent. The trapping structure is associated with a width of ~200 m, S-wave velocity reduction of ~35 per cent with respect to the surrounding rock, Q-value of ~20 and depth of ~3.5 km. The imaging results suggest that the main seismogenic fault is near the SW end of the JF array, in agreement with a prominent geomorphologic feature. The existence of intense local damage on the crustal block with faster larger scale velocity at depth is consistent with common propagation of earthquake ruptures in the area to the NW.

58 GEOSCIENCES↗

Optical recognition of constructs using hyperspectral imaging and detection (ORCHID)

Abstract Challenges to deep sample imaging have necessitated the development of special techniques such as spatially offset optical spectroscopy to collect signals that have travelled through several layers of tissue. However, these techniques provide only spectral information in one dimension (i.e., depth). Here, we describe a general and practical method, referred to as Optical Recognition of Constructs Using Hyperspectral Imaging and Detection (ORCHID). The sensing strategy integrates (1) the spatial offset detection concept by computationally binning 2D optical data associated with digital offsets based on selected radial pixel distances from the excitation source; (2) hyperspectral imaging using tunable filter; and (3) digital image binding and collation. ORCHID is a versatile modality that is designed to collect optical signals deep inside samples across three spatial (X, Y, Z) as well as spectral dimensions. The ORCHID method is applicable to various optical techniques that exhibit narrow-band structures, from Raman scattering to quantum dot luminescence. Samples containing surface-enhanced Raman scattering (SERS)-active gold nanostar probes and quantum dots embedded in gel were used to show a proof of principle for the ORCHID concept. The resulting hyperspectral data cube is shown to spatially locate target emitting nanoparticle volumes and provide spectral information for in-depth 3D imaging.

47 OTHER INSTRUMENTATION↗

Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept

Purpose: Molecular breast imaging (MBI) is a dedicated nuclear medicine breast imaging modality that employs dual-head cadmium zinc telluride (CZT) gamma cameras to functionally detect breast cancer. MBI has been shown to detect breast cancers otherwise occult on mammography and ultrasound. Currently, a MBI-guided biopsy system does not exist to biopsy such lesions. Our objective was to consider the utility of a novel conical slant-hole (CSH) collimator for rapid (<1 min) and accurate monitoring of lesion position to serve as part of a MBI-guided biopsy system. Methods: An initial CSH collimator design was derived from the dimensions of a parallel-hole collimator optimized for MBI performed with dual-head CZT gamma cameras. The parameters of the CSH collimator included the collimator height, cone slant angle, thickness of septa and cones of the collimator, and the annular areas exposed at the base of the cones. These parameters were varied within the geometric constraints of the MBI system to create several potential CSH collimator designs. The CSH collimator designs were evaluated using Monte Carlo simulations. The model included a breast compressed to a thickness of 6 cm with a 1-cm diameter lesion located 3 cm from the collimator face. The number of particles simulated was chosen to represent the count density of a low-dose, screening MBI study acquired with the parallel-hole collimator for 10 min after a {approx}150 MBq (4 mCi) injection of Tc-99m sestamibi. The same number of particles was used for the CSH collimator simulations. In the resulting simulated images, the count sensitivity, spatial resolution, and accuracy of the lesion depth determined from the lesion profile width were evaluated. Results: The CSH collimator design with default parameters derived from the optimal parallel-hole collimator provided 1-min images with error in the lesion depth estimation of 1.1 {+-} 0.7 mm and over 21 times the lesion count sensitivity relative to 1-min images acquired with the current parallel-hole collimator. Sensitivity was increased via more vertical cone slant angles, larger annular areas, thinner cone walls, shorter cone heights, and thinner radiating septa. Full width at half maximum trended in the opposite direction as sensitivity for all parameters. There was less error in the depth estimates for less vertical slant angles, smaller annular areas, thinner cone walls, cone heights near 1 cm, and generally thinner radiating septa. Conclusions: A Monte Carlo model was used to demonstrate the feasibility of a CSH collimator design for rapid biopsy application in molecular breast imaging. Specifically, lesion depth of a 1-cm diameter lesion positioned in the center of a typical breast can be estimated with error of less than 2 mm using circumferential count profiles of images acquired in 1 min.

60 APPLIED LIFE SCIENCES↗

Thermographic imaging for high-temperature composite materials: A defect detection study

The ability of a thermographic imaging technique for detecting flat-bottom hole defects of various diameters and depths was evaluated in four composite systems (two types of ceramic matrix composites, one metal matrix composite, and one polymer matrix composite) of interest as high-temperature structural materials. The holes ranged from 1 to 13 mm in diameter and 0.1 to 2.5 mm in depth in samples approximately 2-3 mm thick. The thermographic imaging system utilized a scanning mirror optical system and infrared (IR) focusing lens in conjunction with a mercury cadmium telluride infrared detector element to obtain high resolution infrared images. High intensity flash lamps located on the same side as the infrared camera were used to heat the samples. After heating, up to 30 images were sequentially acquired at 70-150 msec intervals. Limits of detectability based on depth and diameter of the flat-bottom holes were defined for each composite material. Ultrasonic and radiographic images of the samples were obtained and compared with the thermographic images.

Roth, Don J.↗

Hyperspectral Infrared Imaging of Flames Using a Spectrally Scanning Fabry-Perot Filter

The temperatures and compositions of gases in and around flames can be diagnosed using infrared emission spectroscopy to observe molecular band shapes and intensities. We have combined this approach with a low-order scanning Fabry-Perot filter and an infrared camera to obtain spectrally scanned infrared emission images of a laboratory flame and exhaust plume from 3.7 to 5.0 micrometers, at a spectral resolution of 0.043 micrometers, and a spatial resolution of 1 mm. The scanning filter or AIRIS (Adaptive Infrared Imaging Spectroradiometer) is a Fabry-Perot etalon operating in low order (mirror spacing = wavelength) such that the central spot, containing a monochromatic image of the scene, is viewed by the detector array. The detection system is a 128 x 128 liquid-nitrogen-cooled InSb focal plane array. The field of view is controlled by a 50 mm focal length multielement lens and an V4.8 aperture, resulting in an image 6.4 x 6.4 cm in extent at the flame and a depth of field of approximately 4 cm. Hyperspectral images above a laboratory CH4/air flame show primarily the strong emission from CO2 at 4.3 micrometers, and weaker emissions from CO and H2O. We discuss techniques to analyze the spectra, and plans to use this instrument in microgravity flame spread experiments.

Rawlins, W. T.↗

Thermographic Characterization of Impact Damage in SiC/SiC Composite Materials

SiC/SiC composite materials targeted as turbine components for next-generation aero-engines are being investigated at NASA Glenn Research Center. In order to examine damage mechanisms in these materials, SiC/SiC coupons were impacted with 1.59 mm diameter steel spheres at increasing velocities from 115 m/s to 400 m/s. Pulsed thermography, a nondestructive evaluation technique that monitors the thermal response of a sample over time, was utilized to characterize the impact damage. A thermal standard of similar material was fabricated to aid in the interpretation of the thermographic data and to provide information regarding thermography system detection capabilities in 2.4 mm thick SiC/SiC composite materials. Flat bottom holes at various depths with aspect ratios greater than 2.5 were detectable in the thermal images. In addition, the edges of holes at depths of 1.93 mm into the sample were not as resolvable as flat bottom holes closer to the surface. Finally, cooling behavior was characterized in SiC/SiC materials and used to determine impact damage depth within an 8.5% error of a known depth.

Fox, Dennis S.↗

PTT System Design and Data Analysis for Improved Performance: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for non-destructive evaluation (NDE) either during or post manufacturing. Known material flaws in AM include low density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusively using a unique inversion algorithm developed at Argonne. This study investigates the limits of PTT capability in detection of defects in metallic plates using COMSOL numerical modeling of heat transfer. Defects are modeled as cylindrical flat bottom holes (FBH), which is a common model of calibrated material flaws in thermal tomography experiments. Materials considered in this study include stainless steel 316 (SS316), stainless steel 304 (SS304), and Inconel 718. Theoretical analyses were conducted to validate inversion of simulated PTT data with COMSOL for a plate. Subsequently, 3D reconstructions were performed on COMSOL simulations for FBH, revealing a decrease in spatial resolution over depth due to thermal diffusion. The results of this study show that the performance of the inversion algorithm for detecting smaller defects depends strongly on the depth of the defect as well as the incident heat flux. The size of detectable defect was estimated by fitting a Gaussian function to surface temperature profile. The criteria for detectability was taken as 20mK noise equivalent temperature difference (NETD), which is currently the sensitivity limit of high-performance infrared cameras. It was determined through computer simulations that the smallest detectable FBH in SS316 has a 50µm diameter and is located 0.5mm below the plate surface.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using High Frequency Focused Water-Coupled Ultrasound for 3-D Surface Depression Profiling

Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. A prior study was performed demonstrating that focused air-coupled ultrasound at 1 MHz was capable of profiling surfaces with 25 micron depth resolution and 400 micron lateral resolution over a 1.4 mm depth range. In this article, the question of whether higher-frequency focused water-coupled ultrasound can improve on these specifications is addressed. 10 and 25 MHz focused ultrasonic transducers were employed in the water-coupled mode. Time-of-flight images of the sample surface were acquired and converted to depth / surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in water (V). Results are compared for the two frequencies used and with those from the 1 MHz air-coupled configuration.

Roth, Don J.↗