Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection probability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Constraining Gamma-Ray Pulsar Gap Models with a Simulated Pulsar Population

With the large sample of young gamma-ray pulsars discovered by the Fermi Large Area Telescope (LAT), population synthesis has become a powerful tool for comparing their collective properties with model predictions. We synthesised a pulsar population based on a radio emission model and four gamma-ray gap models (Polar Cap, Slot Gap, Outer Gap, and One Pole Caustic). Applying gamma-ray and radio visibility criteria, we normalise the simulation to the number of detected radio pulsars by a select group of ten radio surveys. The luminosity and the wide beams from the outer gaps can easily account for the number of Fermi detections in 2 years of observations. The wide slot-gap beam requires an increase by a factor of 10 of the predicted luminosity to produce a reasonable number of gamma-ray pulsars. Such large increases in the luminosity may be accommodated by implementing offset polar caps. The narrow polar-cap beams contribute at most only a handful of LAT pulsars. Using standard distributions in birth location and pulsar spin-down power (E), we skew the initial magnetic field and period distributions in a an attempt to account for the high E Fermi pulsars. While we compromise the agreement between simulated and detected distributions of radio pulsars, the simulations fail to reproduce the LAT findings: all models under-predict the number of LAT pulsars with high E , and they cannot explain the high probability of detecting both the radio and gamma-ray beams at high E. The beaming factor remains close to 1.0 over 4 decades in E evolution for the slot gap whereas it significantly decreases with increasing age for the outer gaps. The evolution of the enhanced slot-gap luminosity with E is compatible with the large dispersion of gamma-ray luminosity seen in the LAT data. The stronger evolution predicted for the outer gap, which is linked to the polar cap heating by the return current, is apparently not supported by the LAT data. The LAT sample of gamma-ray pulsars therefore provides a fresh perspective on the early evolution of the luminosity and beam width of the gamma-ray emission from young pulsars, calling for thin and more luminous gaps.

Pierbattista, Marco↗

HABITABLE PLANETS ECLIPSING BROWN DWARFS: STRATEGIES FOR DETECTION AND CHARACTERIZATION

Given the very close proximity of their habitable zones, brown dwarfs (BDs) represent high-value targets in the search for nearby transiting habitable planets that may be suitable for follow-up occultation spectroscopy. In this paper, we develop search strategies to find habitable planets transiting BDs depending on their maximum habitable orbital period (P{sub HZ{sub out}}). Habitable planets with P{sub HZ{sub out}} shorter than the useful duration of a night (e.g., 8-10 hr) can be screened with 100% completeness from a single location and in a single night (near-IR). More luminous BDs require continuous monitoring for longer duration, e.g., from space or from a longitude-distributed network (one test scheduling achieved three telescopes, 13.5 contiguous hours). Using a simulated survey of the 21 closest known BDs (within 7 pc) we find that the probability of detecting at least one transiting habitable planet is between 4.5{sup +5.6}{sub -1.4}% and 56{sup +31}{sub -13}%, depending on our assumptions. We calculate that BDs within 5-10 pc are characterizable for potential biosignatures with a 6.5 m space telescope using {approx}1% of a five-year mission's lifetime spread over a contiguous segment only one-fifth to one-tenth of this duration.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗

Stimulus configuration determines the detectability of motion signals in noise

We measured the detectability of moving signal dots in dynamic noise to determine whether local motion signals are preferentially combined along an axis parallel to the direction of motion. Observers were asked to detect a signal composed of three dots moving in a linear trajectory among dynamic noise dots. The signal dots were collinear and equally spaced in a configuration that was either parallel to or perpendicular to their trajectory. The probability of detecting the signal was measured as a function of noise density, over a range of signal dot spacings from 0.5 degrees to 5.0 degrees. At any given noise density, the signal in the parallel configuration was more detectable than that in the perpendicular configuration. Our four observers could tolerate 1.5-2.5 times more noise in the parallel configuration. This improvement is not due merely to temporal summation between consecutive dots in the parallel trajectory. Temporal summation functions measured on our observers indicate that the benefit from spatial coincidence of the dots lasts for no more than 50 ms, whereas the increased detectability of the parallel configuration is observed up to the largest temporal separations tested (210 ms). These results demonstrate that dots arranged parallel to the signal trajectory are more easily detected than those arranged perpendicularly. Moreover, this enhancement points to the existence of visual mechanisms that preferentially organize motion information parallel to the direction of motion.

Non-NASA Center↗

Explosive Detection in Aviation Applications Using CT

CT scanners are deployed world-wide to detect explosives in checked and carry-on baggage. Though very similar to single- and dual-energy multi-slice CT scanners used today in medical imaging, some recently developed explosives detection scanners employ multiple sources and detector arrays to eliminate mechanical rotation of a gantry, photon counting detectors for spectral imaging, and limited number of views to reduce cost. For each bag scanned, the resulting reconstructed images are first processed by automated threat recognition algorithms to screen for explosives and other threats. Human operators review the images only when these automated algorithms report the presence of possible threats. The US Department of Homeland Security (DHS) has requirements for future scanners that include dealing with a larger number of threats, higher probability of detection, lower false alarm rates and lower operating costs. One tactic that DHS is pursuing to achieve these requirements is to augment the capabilities of the established security vendors with third-party algorithm developers. A third-party in this context refers to academics and companies other than the established vendors. DHS is particularly interested in exploring the model that has been used very successfully by the medical imaging industry, in which university researchers develop algorithms that are eventually deployed in commercial medical imaging equipment. The purpose of this paper is to discuss opportunities for third-parties to develop advanced reconstruction and threat detection algorithms.

42 ENGINEERING↗

Fully integrated safeguards and security for reprocessing plant monitoring.

Nuclear fuel reprocessing plants contain a wealth of plant monitoring data including material measurements, process monitoring, administrative procedures, and physical protection elements. Future facilities are moving in the direction of highly-integrated plant monitoring systems that make efficient use of the plant data to improve monitoring and reduce costs. The Separations and Safeguards Performance Model (SSPM) is an analysis tool that is used for modeling advanced monitoring systems and to determine system response under diversion scenarios. This report both describes the architecture for such a future monitoring system and present results under various diversion scenarios. Improvements made in the past year include the development of statistical tests for detecting material loss, the integration of material balance alarms to improve physical protection, and the integration of administrative procedures. The SSPM has been used to demonstrate how advanced instrumentation (as developed in the Material Protection, Accounting, and Control Technologies campaign) can benefit the overall safeguards system as well as how all instrumentation is tied into the physical protection system. This concept has the potential to greatly improve the probability of detection for both abrupt and protracted diversion of nuclear material.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of PCR Systems for Field Screening of Bacillus anthracis

There is little published data on the performance of hand-portable polymerase chain reaction (PCR) instruments that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated five commercially available hand-portable PCR instruments for detection of Bacillus anthracis (Ba). We designed a cost-effective, statistically-based test plan that allows instruments to be evaluated at performance levels ranging from 0.85-0.95 lower confidence bound (LCB) on the probability of detection (POD) at confidence levels of 80-95%. We assessed specificity using purified genomic DNA from 13 Ba strains and 18 Bacillus near neighbors, interference with 22 common hoax powders encountered in the field, and PCR inhibition when Ba spores were spiked into these powders. Our results indicated that three of the five instruments achieved >0.95 LCB on the POD with 95% confidence at test concentrations of 2,000 genome equivalents/mL (comparable to 2,000 spores/mL), displaying more than sufficient sensitivity for screening suspicious powders. These instruments exhibited no false positive results or PCR inhibition with common hoax powders, and reliably detected Ba spores spiked into common hoax powders, though some issues with instrument controls were observed. Our testing approach enables efficient instrument performance testing to a statistically rigorous and cost-effective test plan to generate performance data that will allow users to make informed decisions regarding the purchase and use of biodetection equipment in the field.

59 BASIC BIOLOGICAL SCIENCES↗

The Safety Course Design and Operations of Composite Overwrapped Pressure Vessels (COPV)

Following a Commercial Launch Vehicle On-Pad COPV (Composite Overwrapped Pressure Vessels) failure, a request was received by the NESC (NASA Engineering and Safety Center) June 14, 2014. An assessment was approved July 10, 2014, to develop and assess the capability of scanning eddy current (EC) nondestructive evaluation (NDE) methods for mapping thickness and inspection for flaws. Current methods could not identify thickness reduction from necking and critical flaw detection was not possible with conventional dye penetrant (PT) methods, so sensitive EC scanning techniques were needed. Developmental methods existed, but had not been fully developed, nor had the requisite capability assessment (i.e., a POD (Probability of Detection) study) been performed.

Saulsberry, Regor↗

Observations of optical counterparts of Gamma-Ray bursts

This is a final report for a contract begun in Dec. 1987 and ended in Mar. 1989 to use the existing Lincoln Laboratory Experimental Test Site in Socorro, NM to search for optical counterparts to gamma-ray bursts. The objective was to develop an autonomous staring system to search for stationary, transient optical flashes. The search was to use an existing 31-inch telescope equipped with a sensitive video detector. The approach for the search was to develop real-time processing software to monitor the video signal from the detector and to record any transient, point-like flashes that occurred in the field of view. The system would have been able to detect fainter flashes (B is approximately 15(sup m) in 1/30 s, delta(m(sub v)) = 0.25(sup m)) than other systems but lacked a large field of view (only 1.2 deg diameter) necessary to give a high probability of detecting a random flash on the sky. As such, the plan was to monitor known gamma-ray burst error boxes and wait for a repetition of an earlier event. The high payoff of good sensitivity with high angular resolution (1 pixel = 10sec) and good time resolution (30 s) to allow post-burst searches warranted funding if the cost was not prohibitive. The contract began in the middle of the three-year cycle for High Energy Astrophysics Gamma-Ray Astronomy Research and Analysis Program. This final report briefly describes the portion of the plan completed under the original contract.

Knight, Frederick K.↗

Spatial patterns in occupancy and density of larval lampreys in freshwater habitats restored to a Stage 0 condition

Abstract We examined occupancy and density of larval lampreys ( Entosphenus tridentatus and Lampetra spp.) in two rivers in Oregon (USA) restored to a Stage 0 condition 1–5 years prior, using a multiscale occupancy model and a zero‐inflated Poisson mixture model. We sampled lampreys using backpack electrofishing in randomly distributed, paired, 1‐m 2 quadrats and recorded environmental data. Probabilities of occupancy and density were higher when water velocity was low, the substrate was noncompacted, and sediment was dominated by fines (<4 mm). At mean water depth (0.34 m) and velocity (0.09 m/s), estimated densities in occupied quadrats were 4.8 lampreys/m 2 (95%: 3.4–6.9) when the substrate was compacted, and fines were not dominant, and 21.1 lampreys/m 2 (95%: 17.7–25.3) when the substrate was noncompacted and fines were dominant. Probabilities of detecting occupancy in a 1‐m 2 quadrat sampled by backpack electrofishing were 0.76 (95%: 0.64–0.87) when captured after visual observation and 0.80 (95%: 0.71–0.88) with blind sweeps (i.e., constantly moving the net regardless of observation). The probability of capturing a single lamprey in a quadrat sampled by blind sweeps was 0.32 (95%: 0.27–0.37). Sampling in paired 1‐m 2 quadrats facilitated concurrent examination of patterns in occupancy and density while accounting for capture probability, which could aid temporal monitoring of restored habitats. To the best of our knowledge, this is the first study to document occupancy and estimate densities of larval lampreys in habitats that underwent valley floor restoration to Stage 0. We observed both lamprey genera within 5 years of restoration. Aquatic restoration that increases low‐velocity, noncompacted, fine sediment habitats could benefit lampreys.

Harris, Julianne E.↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Stereo-Optic High Definition Imaging: A New Technology to Understand Bird and Bat Avoidance of Wind Turbines

There is a critical need to develop monitoring tools to track aerofauna (birds and bats) in three dimensions around wind turbines. New monitoring systems will reduce permitting uncertainty by increasing the understanding of how birds and bats are interacting with wind turbines, which will improve the accuracy of impact predictions. Biodiversity Research Institute (BRI), The University of Maine Orono School of Computing and Information Science (UMaine SCIS), HiDef Aerial Surveying Limited (HiDef), and SunEdison, Inc. (formerly First Wind) responded to this need by using stereo-optic cameras with near-infrared (nIR) technology to investigate new methods for documenting aerofauna behavior around wind turbines. The stereo-optic camera system used two synchronized high-definition video cameras with fisheye lenses and processing software that detected moving objects, which could be identified in post-processing. The stereo- optic imaging system offered the ability to extract 3-D position information from pairs of images captured from different viewpoints. Fisheye lenses allowed for a greater field of view, but required more complex image rectification to contend with fisheye distortion. The ability to obtain 3-D positions provided crucial data on the trajectory (speed and direction) of a target, which, when the technology is fully developed, will provide data on how animals are responding to and interacting with wind turbines. This project was focused on testing the performance of the camera system, improving video review processing time, advancing the 3-D tracking technology, and moving the system from Technology Readiness Level 4 to 5. To achieve these objectives, we determined the size and distance at which aerofauna (particularly eagles) could be detected and identified, created efficient data management systems, improved the video post-processing viewer, and attempted refinement of 3-D modeling with respect to fisheye lenses. The 29-megapixel camera system successfully captured 16,173 five-minute video segments in the field. During nighttime field trials using nIR, we found that bat-sized objects could not be detected more than 60 m from the camera system. This led to a decision to focus research efforts exclusively on daytime monitoring and to redirect resources towards improving the video post- processing viewer. We redesigned the bird event post-processing viewer, which substantially decreased the review time necessary to detect and identify flying objects. During daytime field trials, we determine that eagles could be detected up to 500 m away using the fisheye wide-angle lenses, and eagle-sized targets could be identified to species within 350 m of the camera system. We used distance sampling survey methods to describe the probability of detecting and identifying eagles and other aerofauna as a function of distance from the system. The previously developed 3-D algorithm for object isolation and tracking was tested, but the image rectification (flattening) required to obtain accurate distance measurements with fish-eye lenses was determined to be insufficient for distant eagles. We used MATLAB and OpenCV to improve fisheye lens rectification towards the center of the image, but accurate measurements towards the image corners could not be achieved. We believe that changing the fisheye lens to rectilinear lens would greatly improve position estimation, but doing so would result in a decrease in viewing angle and depth of field. Finally, we generated simplified shape profiles of birds to look for similarities between unknown animals and known species. With further development, this method could provide a mechanism for filtering large numbers of shapes to reduce data storage and processing. These advancements further refined the camera system and brought this new technology closer to market. Once commercialized, the stereo-optic camera system technology could be used to: a) research how different species interact with wind turbines in order to refine collision risk models and inform mitigation solutions; and b) monitor aerofauna interactions with terrestrial and offshore wind farms replacing costly human observers and allowing for long-term monitoring in the offshore environment. The camera system will provide developers and regulators with data on the risk that wind turbines present to aerofauna, which will reduce uncertainty in the environmental permitting process.

Adams, Evan↗

A Quantitative Assessment of Advanced NDI Techniques for Detecting Flaws in Composite Laminate Aircraft Structures. Draft

The aircraft industry continues to increase its use of composite materials, most noteworthy in the arena of principle structural elements. This expanded use, coupled with difficulties associated with damage tolerance analysis of composites, has placed greater emphasis on the application of accurate nondestructive inspection (NDI) methods. Traditionally, a few ultrasonic-based inspection methods have been used to inspect solid laminate structures. Recent developments in more advanced NDI techniques have produced a number of new inspection options. Many of these methods can be categorized as wide area techniques that produce two-dimensional flaw maps of the structure. An experiment has been developed to assess the ability of both conventional and advanced NDI techniques to detect voids, disbonds, delaminations, and impact damage in adhesively bonded composite aircraft structures. A series of solid laminate, carbon composite specimens with statistically relevant flaw profiles are being inspected using conventional, hand-held pulse echo UT and resonance, as well as, new NDI methods that have recently been introduced to improve sensitivity and repeatability of inspections. The primary factors affecting flaw detection in laminates are included in this study: material type, flaw profiles, presence of complex geometries like taper and substructure elements, presence of fasteners, secondarily bonded joints, and environmental conditions. One phase of this effort utilized airline personnel to study Probability of Detection (POD) in the field and to formulate improvements to existing inspection techniques. In addition, advanced NDI methods for laminate inspections — such as thermography, shearography, laser ultrasonics, microwave, and phased/linear array UT — were applied to quantify the improvements achievable through the use of more sophisticated NDI. This report presents the composite laminate experiment design and the POD results for advanced NDI with comparisons to results achieved by airline inspectors using conventional UT methods. A companion report provides the full set of results from the conventional NDI testing.

36 MATERIALS SCIENCE↗

Examining Nuisance Aerosol Detections in Light of the Origin of the Screening Process (November 2021)

The evolution of philosophy and computations in the International Data Center (IDC) related to aerosol samples have had profound impacts on the number of recorded detections in the network since routine operations began in 2000. Key decisions from policymakers have been the list of triggering radionuclides, the scheme for categorizing these into interest levels 1-5, and an algorithm for determining when an anthropogenic isotope is seen so often that it is no longer interesting, known as the Exponential Weighted Moving Average (EWMA). These are described in the Operations Manual of the IDC. Key parameters that are controlled by the IDC but for which the IDC receives occasional input from policymakers include the constants in EWMA and the peak significance threshold for individual gamma rays, the latter of which directly leads to determination of the presence or absence of a radionuclide in a sample. There are also changes in computations which the IDC makes and informs policy makers about, such as changes in how background is computed, which could also affect the ease of detecting a peak – real or false. Rather than focus on the quantitative changes due to computation changes, this work records some thinking on how isotopes and peak significance levels were chosen, and the resulting detections seen over 18 years during the buildup of the International Monitoring System (IMS). These detections are considered on a global scale to try to determine the relative impact on monitoring, and in some cases, the nature of their existence. Repeated detections of 131I and 133I are the most troublesome, but they are not so frequent to be a major problem for the Verification Regime. These detections could probably be handled adequately using scientific methods currently under development for xenon backgrounds. It is also somewhat problematic that top-level analysis of aerosol backgrounds has not been reported previous to this. The steep increase in the rate of detections after 2016 are a concern, either in the actual backgrounds or from changes in the calculations methods used to generate the Reviewed Radionuclide Report (RRR.) Final conclusions of the authors are that the computational stability of the RRR is very important. With computational stability, changes can be usefully analyzed as being due to changes in radioactivity in Earth’s atmosphere This report is a distillation into text of a talk given in the Radionuclide Experts Group (RNEG) in Vienna during Working Group B (WGB) in February of 2019. This report does not directly contain any IDC data, only summaries by year, or by isotope, or by location. No specific IDC detection by time, location, or isotope is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical comparison of pooled nitrogen washout data of various altitude decompression response groups

This analysis was done to determine whether various decompression response groups could be characterized by the pooled nitrogen (N2) washout profiles of the group members, pooling individual washout profiles provided a smooth time dependent function of means representative of the decompression response group. No statistically significant differences were detected. The statistical comparisons of the profiles were performed by means of univariate weighted t-test at each 5 minute profile point, and with levels of significance of 5 and 10 percent. The estimated powers of the tests (i.e., probabilities) to detect the observed differences in the pooled profiles were of the order of 8 to 30 percent.

Edwards, B. F.↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

Ellis, Tayera↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

Ellis, Tayera↗