Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Natural circulation loop using liquid nitrogen for cryo-detection system

The natural circulation loop is designed for the cryogenic insert in a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Sensitivity is the key parameter of a FTICR mass spectrometer and the cryo-cooling of the pre-amplifier can reduce the thermal noise level and thereby improve the signal-to-noise ratio. The pre-amplifier consisted of non-magnetic materials is thermally connected to the cooling loop which is passing through the flange maintaining ultra-high vacuum in the ion cell. The liquid nitrogen passes through inside of the loop to cool the pre-amplifier indirectly. At the end, a cryocooler is located to re-condense nitrogen vapor generated due to the heat from the pre-amplifier. The circulating fluid removes heat from the pre-amplifier and transports it to the cryocooler or heat sink. In this paper the natural circulation loop for cryogenic pre-amplifier is introduced for improving the sensitivity of cryo-detector. In addition, the initial cool-down of the system by a cryocooler is presented and the temperature of the radiation shield is discussed with respect to the thickness of shield and the thermal radiation load.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DimaSense™: A Novel Nucleic Acid Detection System

Recently, we developed a suite of methods for the rational design and fabrication of well-defined nanoparticle architectures, including clusters using bio-encoded nanoscale building blocks and layer-by-layer stepwise assembly on a solid support. In particular, the Nano-Assembly platform using Encoded Solid Supports (NAESS) allows for controlled interactions, purification of side products, modularity of design, and the construction of complex nanoparticle architectures. This approach offers several advantages over the current art of designing nanoparticle clusters, which include the high-yield synthesis of desired architectures, a 'plug-and-play' design allowing for the introduction of a variety of sensing modalities, and ease of scalability in high-throughput and synthesis yield. As a utility proof of concept, we implemented our unique cluster fabrication platform to design gold nanoparticle dimers which are linked via a single-stranded DNA oligonucleotide recognition motif. The design of this motif is such that binding of complementary nucleic acids results in specific, selective and rapid dimer dissociation, which can be monitored by dynamic light scattering (DLS). We demonstrated single level mismatch selectivity using this approach. The limit of detection was determined to be 1011 molecules of synthetic target RNA or DNA within 30 minutes of incubation at 33 C. This detection limit is determined by the dimer's concentration which can be probed by currently used standard DLS instruments. We also demonstrated a specific detection of target RNA in a solution containing competing 1,000-fold excess of non-complementary DNA fragments, 10% BSA, and endonucleases. Molecular diagnostic companies, RNA-based technology developers, and personalized medicine companies have applications that could benefit from using DimaSense{trademark}. The technology represents a platform which enables the simple and reasonably inexpensive design and fabrication of highly selective genetic sensors. These sensors operate with very low concentrations of target, can utilize standard instrumentation, produce detection results rapidly, and are robust enough to function in the presence of many competing genetic targets. Many current genetic target detection products/approaches/technologies rely upon methods (such as qPCR) which are more complicated, cumbersome, and costly to perform, and are not well suited to point-of-care diagnostic applications. Several clinical diagnostic applications, particularly point-of-care (POC) diagnostics for infectious diseases, are possible and appear to be a good fit for the technology. In addition, the advent of personalized medicine will create opportunities for molecular diagnostic companies with the capabilities of rapidly and quantitatively detecting nucleic acid sequences. The global POC market was {approx}$7.7B in 2010, with a recent annual growth rate of {approx}7%. A specific disease or disease-class diagnostic would need to be identified before a more meaningful sub-market value could be stated. Additional validation of the technology to show that it displays appropriate performance parameters for a commercial application on 'real world' samples is required for true commercial readiness. In addition, optimization of sensor design parameters, to effect a 10-fold increase in sensitivity, may be required to produce a commercially ready sensor system. These validation and sensor design optimization are estimated to require 3-4 months and {approx}$75k. For an unregulated product to give this sensor system a distinct competitive advantage, 2-3 years of product development and $1.5-3M are likely required. For regulated markets, time to market (through clinic) and cost would depend upon the product.

59 BASIC BIOLOGICAL SCIENCES↗

Commercially available Hydrogen Detection Systems for Corrosive, Oxygen-free Gas Streams: A Technical Summary

The growing use of hydrogen gas across energy, transportation, and chemical applications necessitates better hydrogen sensors and detectors. Few sensors exist for quantifying hydrogen gas in a corrosive, oxygen-free gas stream due to the challenging nature of the sampling environment and current technological status. Handheld, economic options include palladium-based, metal oxide, catalytic bead, and electrochemical sensors. More permanent and costly options include electrochemical sensors, thermal gas analyzers, mass spectrometers, gas chromatographs, and Raman spectrometers. In this technical report, a short review of current technology, along with the associated commercially available products, is provided. Raman spectroscopy is recommended as an ideal technology for on-line detection of hydrogen at low concentrations in a corrosive, oxygen-free gas stream.

08 HYDROGEN↗

Multiple rate digital command detection system with range clean-up capability

A multi-rate digital command system is disclosed which uses the composite signal of a mu-type ranging system as a subcarrier to transmit range codes and data from a station to a receiver where the range codes are sequentially phase modulated on a subcarrier of frequency by one of its own subharmonics and data is phase modulated on a selected ranging component. A range cleanup loop in a spacecraft locks the phase of a locally generated reference component to a received ranging component and retransmits the component to a ground station. When the inverse phase of a ranging component is received and detected, the cleanup loop is modified to demodulate phase modulated command symbols while continuing tracking the same ranging component. The command symbol rate is coherently related to the ranging signal component bit rate.

Lesh, J. R.↗

Semi-empirical simulation of in-motion radiation detection systems

The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Launcher for Wildlife Collision Simulation on Wind Turbines to Validate Strike Detection Systems

Design and construction of a custom launcher and projectiles to simulate wildlife collisions with wind turbines is investigated. The various design features that led to success of the launcher are enumerated and described in detail. These features include custom projectiles, precision aiming capabilities, repeatable launch parameters, and azimuthal control over projectile launch. Success is investigated in terms of an overall hit percentage.

collision simulation↗

Integrated X-ray detection system for determination of nuclear material concentration

An integrated system of X-ray Absorption Spectrometry (XAS), also called L-edge densitometry for uranium (LED) and X-ray Fluorescence spectrometry (XRF) is designed using Monte Carlo simulation for determining concentration of uranium and minor actinides for safeguard. The system can be useful to determination uranium and minor actinide, such as plutonium, neptunium, and etc., concurrently. The equipment is compact compared to the K-edge densitometer with high purity germanium detector which needs liquid nitrogen cooling since a low energy X-ray source is used. The system has been validated from simulation and analysis of the transmitted and reflected spectrum. The concentrations of nuclear material samples are obtained from this study. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power System Event Detection Using the Energy Detector: A Performance Analysis

As the grid becomes smarter, the need to accurately detect, predict, and classify waveform phenomena is growing. When it comes to detecting high-frequency behaviors, i.e. transients, it is especially important to employ an event detection system that is able to accurately uncover these types of disturbances that would otherwise be lost with traditional hardware. In this paper, we first present the energy detector; a waveform event detection system that adaptively monitors a signal's energy and picks out high-frequency events that deviate from the nominal state. Secondly, we evaluate the performance of this detector against waveform data that have been corrupted by sensor irregularities. Using Oak Ridge National Laboratory's sensor testbed, we are able to show the results of the detector's performance against events that have been corrupted by three distinct sensor types, and examine how these results change with multiple trials. The results show excellent performance when detecting the beginning of an anomalous event with an average of less than 1% error.

Ekti, Ali Riza↗

Simultaneous projection and detection system of four different frequencies for microwave imaging reflectometry in Large Helical Device

A simultaneous projection/detection system of four different frequencies for microwave imaging reflectometry (MIR) was developed for three-dimensional observation of electron density fluctuations in the Large Helical Device (LHD). The microwave with four frequency components at 60.410, 61.808, 63.008, and 64.610 GHz is projected in a continuous-wave mode to illuminate the target LHD plasma. A two-dimensional horn-antenna mixer array (2D HMA) receives the reflected wave from the plasma as well as the wave from the local oscillator operating at 55.800 GHz. The first intermediate frequency (IF) signals at 4.610, 6.008, 7.208, and 8.810 GHz were confirmed to be obtained by downconversion of these microwaves using the 2D HMA. Each of these first IF components is filtered from each other and downconverted again for the superheterodyne detection. It was confirmed that both the amplitudes and the phases of the detected signals reflect the fluctuations in LHD plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Algorithms Performance Investigation of a Generalized Spreader-Bar Detection System

A “generic” gantry-crane-mounted spreader bar detector has been simulated in the Monte-Carlo radiation transport code MCNP [1]. This model is intended to represent the largest realistically feasible number of detector crystals in a single gantry-crane model intended to sit atop an InterModal Cargo Container (IMCC). Detectors were chosen from among large commonly-available sodium iodide (NaI) crystal scintillators and spaced as evenly as is thought possible with a detector apparatus attached to a gantry crane. Several scenarios were simulated with this model, based on a single IMCC being moved between a ship’s deck or cargo hold and the dock. During measurement, the gantry crane will carry that IMCC through the air and lower it onto a receiving vehicle (e.g. a chassis or a bomb cart). The case of an IMCC being moved through the air from an unknown radiological environment to the ground is somewhat complex; for this initial study a single location was picked at which to simulate background. An HEU source based on earlier validated models was used, and placed at varying depths in a wood cargo. Many statistical realizations of these scenarios are constructed from simulations of the component spectra, simulated to have high statistics. The resultant data are analyzed with several different algorithms. The simulated data were evaluated by each algorithm, with a threshold set to a statistical-only false alarm probability of 0.001 and the resultant Minimum Detectable Amounts were generated for each Cargo depth possible within the IMCC. Using GADRAS as an anomaly detector provided the greatest detection sensitivity, and it is expected that an algorithm similar to this will be of great use to the detection of highly shielded sources.

97 MATHEMATICS AND COMPUTING↗

Product Defect Detection System: SYSM- 5620 Final Project

Retail sales is a growing market estimated to up to seven percent year over year. With this growing market there is also a trend in growing rate of retail returns, estimated just last year at $\$$850 billion. Retail stores must ensure that products available for purchase remain safe, undamaged, and acceptable to customers throughout their time in the store. This job exists regardless of the specific solution used because stores are always responsible for preventing damaged or defective products from reaching customers and when they fail to this is categorized under operation inefficiencies which accounts for an estimated $\$$12 billion in returns. When defective items remain on the sales floor, stores may experience increased returns, reduced customer satisfaction, loss of customer trust, and potential safety concerns depending on the product type. As a result, the core job to be done is to identify defective products quickly, remove them from the sales floor before they are purchased, and preserve useful information about the defect so that the store can improve its handling, stocking, and supplier coordination over time. The need for a more reliable process is especially important in high volume retail environments where employees manage large numbers of products across many aisles, shelves, and storage areas. In these settings, manual inspection alone can be inconsistent and difficult to sustain at the individual item level. At the same time, broader retail trends continue to emphasize operational efficiency, product visibility, and improved customer experience, creating an opportunity for more automated and data driven defect detection methods.

42 ENGINEERING↗

Systematic measurement of fast neutron background fluctuations in an urban area using a mobile detection system

Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reduction in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system

In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4{pi} Detection System for the Measurement of the {sup 6}Li(n,{alpha}){sup 3}H Reaction Cross Section

A dedicated one-dimensional Time Projection Chamber (1D-TPC) was designed and produced at IRMM to determine the {sup 6}Li(n,{alpha}){sup 3}H cross section in the 0.4-2.8 MeV energy range, aiming at 5% accuracy. The basic TPC components were a twin gridded ionisation chamber (GIC) with interwired electrodes and fast digitisation of the anode and cathode signals. The energy of both reaction products emitted from a thin {sup 6}LiF sample at the common TPC cathode was measured. A Kr(97%)CO{sub 2}(3%) mixture was used as the detector gas at a pressure up to 3.5 bar. A {sup 238}U sample mounted on the cathode of an ionisation chamber without grid was used as the neutron flux monitor. Special care was taken to reduce the experimental sources of uncertainty. The beam-monitor {sup 238}U sample was characterised at IRMM by low-geometry {alpha}-counting with an accuracy of 0.1%. A {sup 6}Li sample was produced at IRMM by vacuum evaporation of {sup 6}LiF onto transparent aluminium backing. The number of {sup 6}Li atoms will be measured via Thermal Neutron Depth Profiling with an expected accuracy of 2% with respect to an IRMM Standard Reference Material. First test measurements were performed using a monoenergetic neutron beam produced by the T(p,n){sup 3}He reaction at the IRMM 7 MV Van de Graaff accelerator. The experimental method and preliminary results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗