Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Thermal conductivity tensor of β -1,3,5,7-tetranitro-1,3,5,7-tetrazoctane ( β -HMX) as a function of pressure and temperature

Here, we have used reverse non-equilibrium molecular dynamics (RNEMD) simulations to determine the full thermal conductivity tensor for the monoclinic high explosive crystal β-1,3,5,7-tetranitro-1,3,5,7-tetrazoctane (β-HMX). In order to do so for the monoclinic crystal, four directions for heat propagation are used. Effects of the temperature and pressure are investigated between 200 and 500 K and 0 and 5 GPa, respectively, which approximately covers the range where the β polymorph is stable. Simulations are carried out with the Smith–Bharadwaj non-reactive empirical potential [Smith and Bharadwaj, J. Phys. Chem. B 103, 3570 (1999)], which is known to reproduce well the thermo-elastic properties of HMX. Our results indicate that the thermal conductivity, κ, is highly anisotropic, with 36% difference between the two extreme values at 300 K and 0 GPa. A simple function is used to interpolate κ in the pressure-temperature regime considered in this study, which can be used in continuum models. The results from RNEMD simulations compare well with available experimental results from the literature and allow the determination of κ for any direction and temperature and pressure within or around the fitting interval.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Temperature Microwave Dielectric Properties of JSC-1AC Lunar Simulant

Microwave heating has many potential lunar applications including sintering regolith for lunar surface stabilization and heating regolith for various oxygen production reactors. The microwave properties of lunar simulants must be understood so this technology can be applied to lunar operations. Dielectric properties at microwave frequencies for a common lunar simulant, JSC-1AC, were measured up to 1100 C, which is approximately the melting point. The experimentally determined dielectric properties included real and imaginary permittivity (epsilon', epsilon"), loss tangent (tan delta), and half-power depth, the di stance at which a material absorbs 50% of incident microwave energy. Measurements at 2.45 GHz revealed tan delta of JSC-1A increases from 0.02 at 25 C to 0.31 at 110 C. The corresponding half-power depth decreases from a peak of 286 mm at 110 C, to 13 mm at 1100 C. These data indicate that JSC-1AC becomes more absorbing, and thus a better microwave heater as temperature increases. A half-power depth maximum at 100-200 C presents a barrier to direct microwave heating at low temperatures. Microwave heating experiments confirm the sluggish heating effect of weak absorption below 200 C, and increasingly strong absorption above 200 C, leading to rapid heating and melting of JSC-1AC.

Allan, Shawn M.↗

RHESSI and Trace Observations of the 21 April 2002 X1.5 Flare

Observations of the X1.5 flare on 21 April 2002 are reviewed using the Ramaty High Energy Solar Spectroscopic Imager (RHESSI) and the Transition Region and Coronal Explorer (TRACE). The major findings are as follows: 1. The 3-25 keV X-rays started 54 mins before the EUV (195 A) emission suggesting that the initial energy release heated plasma directly to 220 MK, well above the 1.6 MK needed to produce the Fe XII (195 A) line. 2. Using coaligned 12-25 keV RHESSI and TRACE images, further evidence is found for the existence of hot (15-20 MK) plasma in the 195 A passband. This hot, diffuse emission is attributed to the presence of the Fe XXIV (192 A) line within the TRACE 195 A passband. 3. The 12-25 keV source centroid moves away from the limb with an apparent velocity of approx. 9.9 km/ s, slowing to approx. 1.7 km/ s after 3 hours, its find altitude being approx. 120 Mm after approx. 12 hours. This suggests that the energy release site moves to higher altitudes in agreement with classical flare models. 4. The 50-100 keV emission correlates well with EUV flare ribbons, suggesting thick-target interactions at the footpoints of the magnetic arcade. The 50-100 keV time profile matches the time derivative of the GOES light curve (Neupert effect), which suggests that the same electrons that produced the thick-target hard X-ray emission also heat the plasma seen in soft X-rays. 5. X-ray footpoint emission has an E(sup -3) spectrum down to approx. 10 keV suggesting a lower electron cutoff energy than previously thought. 6. The hard X-ray (25-200 keV) peaks have FWHM durations of approx. 1 min suggesting a more gradual energy release process than expected. 7. The TRACE images reveal a bright symmetric front propagating away from the main flare site at speeds of greater than or = 120 km/ s. This may be associated with fast CME observed several minutes later by LASCO. 8. Dark sinuous lanes are observed in the TRACE images that extend almost radially from the post-flare loop system. This "fan of spines" becomes visible well into the decay phase of the flare and shows evidence for both lateral and downward motions.

Gallagher, Peter T.↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal conductivity tensor of γ and ε -hexanitrohexaazaisowurtzitane as a function of pressure and temperature

Using reverse non-equilibrium molecular dynamics simulations, we have determined the dependences on temperature and pressure of the thermal conductivity tensors for the monoclinic γ and ε polymorphs of hexanitrohexaazaisowurtzitane (HNIW or CL20). In this work, a recently developed non-reactive force field [X. Bidault and S. Chaudhuri, RSC Adv. 9, 39649–39661 (2019)], designed to study polymorphism and phase transitions in CL20, is employed. The effects of temperature and pressure are investigated between 200 and 500 K and up to 0.5 GPa for γ-CL20 and 2 GPa for ε-CL20. In order to obtain the full thermal conductivity tensor, $κ_{ij}$, for the monoclinic crystals, four distinct heat propagation directions are used. We find that $κ_{ij}$ for both polymorphs is more isotropic than for other energetic molecular crystals, including α- and γ-RDX, β-HMX, and PETN, with a maximum difference of 9.8% between orientations observed at 300 K and 0 GPa for γ-CL20 and a maximum difference of 4.8% for ε-CL20. The average thermal conductivity, $\bar{κ}$, of ε-CL20 is 6.4% larger than that of γ-CL20 at 300 K and 0 GPa. Analytic linear functions of the inverse temperature and the pressure are provided, which fit the data well and can be used to predict the thermal conductivity of both polymorphs for any orientation, pressure, and temperature in and around the fitting range. Our predictions agree reasonably well with the limited available experimental data, for which the polymorph type is unknown.

36 MATERIALS SCIENCE↗

On the efficiency of solar heating in the middle atmosphere

The efficiency at which solar ultraviolet radiation absorbed in the Hartley band of ozone is directly converted to heat in the terrestrial mesosphere and lower thermosphere (50-110 km) is calculated. The ozone molecule undergoes photolysis to yield the excited species O(1D) and O2(1Delta) with a quantum yield of about 0.9. Spontaneous emission from O2(1Delta) and from O2(1Sigma) (excited by energy transfer from O/1D/) significantly decreases the amount of energy available for heat. Similarly, the efficiency at which solar ultraviolet radiation absorbed by O2 in the Schumann-Runge continuum is directly converted to heat in the lower thermosphere (95-110 km) is calculated. The O2 undergoes photolysis and the excited product O(1D) is generated. Spontaneous emission from O2(1Sigma) (excited by energy transfer from O/1D/) reduces the amount of energy available for heat in the lower thermosphere. The consideration of these energy transfer and loss processes results in significantly reduced heating rates as compared to those conventionally calculated in models of the middle atmosphere.

Mlynczak, Martin G.↗

Estimation of instantaneous heat transfer coefficients for a direct-injection stratified-charge rotary engine

The main objective of this report was to derive equations to estimate heat transfer coefficients in both the combustion chamber and coolant pasage of a rotary engine. This was accomplished by making detailed temperature and pressure measurements in a direct-injection stratified-charge rotary engine under a range of conditions. For each sppecific measurement point, the local physical properties of the fluids were calculated. Then an empirical correlation of the coefficients was derived by using a multiple regression program. This correlation expresses the Nusselt number as a function of the Prandtl number and Reynolds number.

Lee, C. M.↗

Elucidating the effect of preheating temperature on melt pool morphology variation in Inconel 718 laser powder bed fusion via simulation and experiment

In laser powder bed fusion (L-PBF) additive manufacturing, the mechanical performance, microstructure and defects of fabricated parts are closely associated with the melt pool morphology, e.g., its dimension and shape through the building process. Past studies have largely focused on how the process parameters such as laser power and scan speed affect melt pool characteristics. In this study, the melt pool morphology variation as a function of preheating temperature in the conduction, transition, and keyhole regimes and the underlying mechanisms in each regime are investigated through ex-situ sample characterization and computation thermal fluid dynamics (CtFD) simulation. Single tracks with different combinations of laser power and scan speed are deposited on an Inconel 718 bare plate preheated to a temperature range of 100–500 °C in the experiment. Significant changes are observed in melt pool morphology as a function of preheating temperature from optical measurements of melt track cross sections. The depth of melt pool in the three regimes increases monotonically with preheating temperature, e.g., at 500 °C, the experimental melt pool depth is increased by 49% in conduction regime, 34% in transition regime and 33% in keyhole regime, respectively, while the variation of melt pool width in each regime does not all follow an increasing trend but depends on the melt pool regimes. Melt pool width variation in the conduction and transition regimes is found to depend on the enhanced heat conduction directly related to temperature dependent thermal properties. Through validated CtFD simulations, it is found that in the keyhole regime the evaporation mass, recoil pressure, and laser drilling effect is enhanced with higher preheating temperature, which gives rise to a deeper melt pool. The simulations also reveal that preheating temperature significantly elongates the melt track length due to the increased flow rate and strong recoil pressure that accelerates the backward flow.

36 MATERIALS SCIENCE↗

Sulfuric Acid Improves the Reactivity of Zeolites via Dealumination

The demand for supplementary cementitious materials (SCMs), like fly ash, slag, and silica fume, is projected to rise over the next few decades. However, global decarbonization efforts, such as decommissioning of coal-fired power plants, will limit the supply of SCMs. Therefore, alternative SCM sources are a critical need for the cement and concrete industry. However, the high crystallinity of zeolites limits their pozzolanic reactivity. The goal of this work was to improve the reactivity of two common zeolites, namely clinoptilolite and SSZ-13, by treating them with sulfuric acid. The treatment enhanced zeolite reactivity via dealumination and decreased particle sizes, which led to increased reactivity with calcium hydroxide, as indicated by a 42.0% increase in reaction heat measured by isothermal calorimetry. Here, we elucidate mechanistic understanding that smaller particle sizes induced by acid treatment accelerated peak heat evolution, while free aluminates from dealumination increased heat via direct reaction with aqueous Ca 2+ .

36 MATERIALS SCIENCE↗

A review of Geological Thermal Energy Storage for seasonal, grid-scale dispatching

Energy storage is essential for the decarbonization of the U.S. energy grid, especially with the increasing deployment of variable renewable energy sources like solar and wind. Geological thermal energy storage (GeoTES) has emerged as a promising long duration, grid scale solution, providing stability and security through flexible operations and valuable grid services. GeoTES utilizes subsurface reservoirs to store thermal energy for power generation and direct-use heating and cooling. This approach significantly enhances the use of low-temperature reservoirs, which would otherwise be unsuitable for geothermal power plants. It also aligns well with depleted oil and gas reservoirs, concentrating solar power, non-flexible renewables (photovoltaic and wind), and geothermal-related power cycles. Given the favorable marginal costs of GeoTES as storage duration increases, it becomes particularly competitive for seasonal, grid-scale dispatch, where few technologies are viable. This paper provides a comprehensive review of GeoTES systems and the research underpinning itsr development. This analysis begins by defining and categorizing the unique characteristics of thermal energy storage techniques, setting GeoTES apart from other technologies. The various components, configurations, subsurface characteristics, and modeling efforts that guide GeoTES development are then explored. Finally, challenges in GeoTES research, development, and deployment are discussed, along with mitigation strategies and lessons from related technologies. Beyond their economic benefits, GeoTES systems support grid resilience and decarbonize industrial processes. Their scalability, broad distribution, seasonal storage potential, and flexible dispatch capacity make GeoTES a valuable tool for expanding renewable energy deployment and addressing climate change.

15 - GEOTHERMAL ENERGY↗

Identifying the Gate-Opening Mechanism in the Flexible Metal–Organic Framework UTSA-300

Atomic-level understanding of the gate-opening phenomenon in flexible porous materials is an important step toward learning how to control, design, and engineer them for applications such as the separation of gases from complex mixtures. Here, we report such mechanistic insight through an in-depth study of the pressure-induced gate-opening phenomenon in our earlier reported metal–organic framework (MOF) Zn(dps) 2 (SiF 6 ) (dps = 4,4'-dipyridylsulfide), also called UTSA-300, using isotherm and calorimetry measurements, in situ infrared spectroscopy, and ab initio simulations. UTSA-300 is shown to selectively adsorb acetylene (C 2 H 2 ) over ethylene (C 2 H 4 ) and ethane (C 2 H 6 ) and undergoes an abrupt gate-opening phenomenon, making this framework a highly selective gas separator of this complex mixture. The selective adsorption is confirmed by pressure-dependent in situ infrared spectroscopy, which, for the first time, shows the presence of multiple C 2 H 2 species with varying strengths of bonding. A rare energetic feature at the gate-opening condition of the flexible MOF is observed in our differential heat energies, directly measured by calorimetry, showcasing the importance of this tool in adsorption property exploration of flexible frameworks and offering an energetic benchmark for further energy-based fundamental studies. Based on the agreement of this feature with ab initio-based adsorption energies of C 2 H 2 in the closed-pore structure UTSA-300a (“a” refers to the activated form), this feature is assigned to the weakening of the H-bond C–H···F formed between C 2 H 2 and fluorine of the MOF. Furthermore, our analysis identifies the weakening of this H-bond, the expansion of the closed-pore MOF upon successive C 2 H 2 coadsorption until its volume is close to that of the open-pore MOF, and the spontaneous gate opening to energetically favor C 2 H 2 adsorption in the open-pore structure as crucial steps in the gate-opening mechanism in this system.

36 MATERIALS SCIENCE↗

High-Performance Thermoelectric Generators for Field Deployments

Thermoelectric power generation is a reliable energy harvesting technique for directly converting heat into electricity. Recent studies have reported the thermal-to-electrical energy conversion efficiency of thermoelectric generators (TEGs) up to 11% under laboratory settings. However, the practical effectiveness of TEGs deployed under real environments is still not more than a few percent. In this study, we provide fundamental insight on the operation of TEGs in realistic environments by illustrating the combinatory effect of thermoelectric material properties, device boundary conditions, and environmental thermal resistivity on TEG performance in conjunction with the module parameters. Using numerical and experimental studies, we demonstrate the existence of a critical heat transfer coefficient that dramatically affects the design and performance of TEGs. Results provide a set of concrete design criteria for developing efficient TEGs that meet the metrics for field deployments. High-performance TEGs demonstrated in this study generated up to 28% higher power and 162% higher power per unit mass of thermoelectric materials as compared to the commercial module deployed for low-grade waste heat recovery. This advancement in understanding the TEG operation will have a transformative impact on the development of scalable thermal energy harvesters and in realizing their practical targets for efficiency, power density, and total output power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lowering the reactor breakeven requirements for proton–boron 11 fusion

Recently, it has been shown that altering the natural collisional power flow of the proton–boron 11 (pB11) fusion reaction can significantly reduce the Lawson product of ion density and confinement time required to achieve ignition. However, these products are still onerous—on the order of 7×1015 cm−3 s under the most optimistic scenarios. Fortunately, a breakeven fusion power plant does not require an igniting plasma, but rather a reactor that produces more electrical power than it consumes. Here, we extend the existing 0D power balance analysis to check the conditions on power plant breakeven. We find that even for the base thermonuclear reaction, modern high-efficiency thermal engines should reduce the Lawson product to 1.2×1015 cm−3 s. We then explore the impact of several potential improvements, including fast proton heating, alpha power capture, direct conversion, and efficient heating. We find that such improvements could reduce the required Lawson product by a further order of magnitude, bringing aneutronic fusion to target ITER ion densities and confinement times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Severe Accident Phenomena: A Comparison Among the NuScale SMR, Other Advanced LWR Designs, and Operating LWRs

During a severe accident in a nuclear reactor, there are a number of phenomenological events which can present a challenge to containment integrity. These include the generation and combustion of hydrogen, energetic fuel-coolant interactions, thermal attack of fission product barriers, core-concrete interactions, direct containment heating, and gradual overpressurization. The advanced design of the NuScale small modular reactor has resulted in the reduced likelihood and severity of severe accident challenges to containment. This paper discusses the features of the NuScale design that reduce the likelihood of occurrence of these severe accident phenomena, and discusses the ability of containment to survive in the unlikely event that they do occur. Here, the impact of severe accident phenomena for the NuScale design is compared and contrasted against other advanced light water reactors, such as AP1000 and ESBWR, as well as the existing fleet, using information from publicly available documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low Thermal Resistance (0.5 K/W) Ga 2 O 3 Schottky Rectifiers With Double-Side Packaging

The low thermal conductivity of Ga 2 O 3 has arguably been the most serious concern for Ga 2 O 3 power and RF devices. Despite many simulation studies, there is no experimental report on the thermal resistance of a large-area, packaged Ga 2 O 3 device. This work fills this gap by demonstrating a 15-A double-side packaged Ga 2 O 3 Schottky barrier diode (SBD) and measuring its junction-to-case thermal resistance (R θJC ) in the bottom-side- and junction-side-cooling configurations. The R θJC characterization is based on the transient dual interface method, i.e., JEDEC 51-14 standard. The R θJC of the junction- and bottom-cooled Ga 2 O 3 SBD was measured to be 0.5 K/W and 1.43 K/W, respectively, with the former R θJC lower than that of similarly-rated commercial SiC SBDs. This low R θJC is attributable to the heat extraction directly from the Schottky junction instead of through the Ga 2 O 3 chip. Here, the R θJC lower than that of commercial SiC devices proves the viability of Ga 2 O 3 devices for high-power applications and manifest the significance of proper packaging for their thermal management.

42 ENGINEERING↗

High-speed phase contrast imaging of spray breakup of jet fuels under combusting conditions

X-ray phase contrast imaging is conducted at 90,517 Hz on a fuel spray to characterize the breakup of the bulk fuel into ligaments and individual droplets in a single-sector, swirl-stabilized combustor under reacting conditions. Phase contrast imaging is used to qualitatively assess spray breakup for two fuels: Jet-A, which represents a normal viscosity fuel, and a blend of JP-5 (64%) and farnesane (36% by volume), which represents a high-viscosity fuel, at three fuel-flow rates and two air inlet temperatures. Time-series images of the fuels show that atomization occurs much more rapidly at higher fuel pressure with thinner ligaments being rapidly shredded. The high-viscosity fuel is qualitatively observed to have markedly longer, thicker ligaments and larger droplet diameters after the primary breakup than the normal viscosity fuel. Using an image processing and droplet quantification strategy, the mean droplet velocity magnitudes were found to decrease with decreasing fuel pressure and fuel-flow rate. The increase in preheat temperature from 323 to 370 K results in an increase in the mean droplet velocity magnitude and a decrease in numerical average and Sauter mean diameter, indicating improved atomization. The high-viscosity fuel was found to have larger average droplet diameters at each condition than the normal viscosity fuel. The increased preheat is found to enhance the combustion efficiency, which is hypothesized to couple with the improved atomization due to the higher combustion temperatures. This indicates the importance of examining spray atomization and breakup under realistic combusting conditions for relevant fuels as the heat release directly couples with the atomization process.

42 ENGINEERING↗