Transforming Power Grid Operations via High Performance Computing

Past power grid blackout events revealed the adequacy of grid operations in responding to adverse situations partially due to low computational efficiency in grid operation functions. High performance computing (HPC) provides a promising solution to this problem. HPC applications in power grid computation also become necessary to take advantage of parallel computing platforms as the computer industry is undergoing a significant change from the traditional single-processor environment to an era for multi-processor computing platforms. HPC applications to power grid operations are multi-fold. HPC can improve today’s grid operation functions like state estimation and contingency analysis and reduce the solution time from minutes to seconds, comparable to SCADA measurement cycles. HPC also enables the integration of dynamic analysis into real-time grid operations. Dynamic state estimation, look-ahead dynamic simulation and real-time dynamic contingency analysis can be implemented and would be three key dynamic functions in future control centers. HPC applications call for better decision support tools, which also need HPC support to handle large volume of data and large number of cases. Given the complexity of the grid and the sheer number of possible configurations, HPC is considered to be an indispensible element in the next generation control centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Preliminary Analysis of Precipitation Properties and Processes during NASA GPM IFloodS

The Iowa Flood Studies (IFloodS) is a NASA Global Precipitation Measurement (GPM) ground measurement campaign, which took place in eastern Iowa from May 1 to June 15, 2013. The goals of the field campaign were to collect detailed measurements of surface precipitation using ground instruments and advanced weather radars while simultaneously collecting data from satellites passing overhead. Data collected by the radars and other ground instruments, such as disdrometers and rain gauges, will be used to characterize precipitation properties throughout the vertical column, including the precipitation type (e.g., rain, graupel, hail, aggregates, ice crystals), precipitation amounts (e.g., rain rate), and the size and shape of raindrops. The impact of physical processes, such as aggregation, melting, breakup and coalescence on the measured liquid and ice precipitation properties will be investigated. These ground observations will ultimately be used to improve rainfall estimates from satellites and in particular the algorithms that interpret raw data for the upcoming GPM mission's Core Observatory satellite, which launches in 2014. The various precipitation data collected will eventually be used as input to flood forecasting models in an effort to improve capabilities and test the utility and limitations of satellite precipitation data for flood forecasting. In this preliminary study, the focus will be on analysis of NASA NPOL (S‐band, polarimetric) radar (e.g., radar reflectivity, differential reflectivity, differential phase, correlation coefficient) and NASA 2D Video Disdrometers (2DVDs) measurements. Quality control and processing of the radar and disdrometer data sets will be outlined. In analyzing preliminary cases, particular emphasis will be placed on 1) documenting the evolution of the rain drop size distribution (DSD) as a function of column melting processes and 2) assessing the impact of range on ground‐based polarimetric radar estimates of DSD properties.

Carey, Lawrence↗

Decentralized Low-Rank State Estimation for Power Distribution Systems

This article considers the low-observability state estimation problem in power distribution networks and develops a decentralized state estimation algorithm leveraging the matrix completion methodology. Matrix completion has been shown to be an effective technique in state estimation that exploits the low dimensionality of the power system measurements to recover missing information. This technique can utilize an approximate (linear) load flow model, or it can be used with no physical models in a network where no information about the topology or line admittance is available. The direct application of matrix completion algorithms requires solving a semi-definite programming (SDP) problem, which becomes computationally challenging for large networks. We therefore develop a decentralized algorithm that capitalizes on the popular proximal alternating direction method of multipliers (proximal ADMM). The method allows us to distribute the computation among different areas of the network, leading to a scalable algorithm. By doing all computations at individual control areas and only communicating with neighboring areas, the algorithm eliminates the need for data to be sent to a central processing unit and thus increases efficiency and contributes to the goal of autonomous control of distribution networks. We illustrate the advantages of the proposed algorithm numerically using standard IEEE test cases.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Modeling of GE Appliances in GridLAB-D: Peak Demand Reduction

The widespread adoption of demand response enabled appliances and thermostats can result in significant reduction to peak electrical demand and provide potential grid stabilization benefits. GE has developed a line of appliances that will have the capability of offering several levels of demand reduction actions based on information from the utility grid, often in the form of price. However due to a number of factors, including the number of demand response enabled appliances available at any given time, the reduction of diversity factor due to the synchronizing control signal, and the percentage of consumers who may override the utility signal, it can be difficult to predict the aggregate response of a large number of residences. The effects of these behaviors can be modeled and simulated in open-source software, GridLAB-D, including evaluation of appliance controls, improvement to current algorithms, and development of aggregate control methodologies. This report is the first in a series of three reports describing the potential of GE's demand response enabled appliances to provide benefits to the utility grid. The first report will describe the modeling methodology used to represent the GE appliances in the GridLAB-D simulation environment and the estimated potential for peak demand reduction at various deployment levels. The second and third reports will explore the potential of aggregated group actions to positively impact grid stability, including frequency and voltage regulation and spinning reserves, and the impacts on distribution feeder voltage regulation, including mitigation of fluctuations caused by high penetration of photovoltaic distributed generation and the effects on volt-var control schemes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model files for estimating snow dynamics and stable water isotopes across the East River, CO.

A coupled hydrologic and snowpack stable water isotope model is used to assesses controls on isotopic inputs across the East River, Colorado, a large, mountainous basin. The hydrologic model uses the semi-empirical, spatially distributed and publicly available U.S. Geological Survey numerical code Precipitation-Modelling Runoff System (PRMS). Water and energy are tracked daily through the atmosphere, canopy and subsurface at a 100-m grid resolution. The isotope mass balance model follows previous work by Ala-aho et al. (2017) to track stable isotopes entering the soil system as snowmelt or rain. Water stores and fluxes needed for the isotope model use hydrologic model output for each timestep and model modeled grid location. This data package provides all files related to the hydrologic model (executable, input and output files), the isotopic model calibration and the historic isotopic model (water years 2015-2020). The isotope model source code and executable are provided. The file "readme.txt" includes information on the file structure, steps to run the model, and description of included folders.

54 ENVIRONMENTAL SCIENCES↗

Aging of galaxies along the morphological sequence, marked by bulge growth and disk quenching

Aims: We revisit the color bimodality of galaxies using the extensive EFIGI morphological classification of nearby galaxies. Methods: The galaxy profiles from the Sloan Digital Sky Survey (SDSS) gri images were decomposed as a bulge and a disk by controlled profile modeling with the Euclid SourceXtractor++ software. The spectral energy distributions from our resulting gri SDSS photometry complemented with Galaxy Evolution Explorer (GALEX) NUV photometry were fitted with the ZPEG software and PEGASE.2 templates in order to estimate the stellar masses and specific star formation rates (sSFR) of whole galaxies as well as their bulge and disk components. Results: The absolute NUV-r color versus stellar mass diagram shows a continuous relationship between the present sSFR of galaxies and their stellar mass, which spans all morphological types of the Hubble sequence monotonously. Irregular galaxies to intermediate-type Sab spirals make up the “Blue Cloud” across 4 orders of magnitude in stellar mass but a narrow range of sSFR. This mass build-up of spiral galaxies requires major mergers, in agreement with their frequently perturbed isophotes. At high mass, the Blue Cloud leads to the “Green Plain”, dominated by S0a and Sa early-type spirals. It was formerly called the “Green Valley”, due to its low density, but we rename it because of its wide stretch and nearly flat density over ~2 mag in NUV-r color (hence sSFR), despite a limited range of stellar mass (1 order of magnitude). The Green Plain links up the “Red Sequence”, containing all lenticular and elliptical galaxies with a 2 order of magnitude mass interval, and systematically higher masses for the ellipticals. We confirm that the Green Plain cannot be studied using u - r optical colors because it is overlayed by the Red Sequence, hence NUV data are necessary. Galaxies across the Green Plain undergo a marked growth by a factor 2 to 3 in their bulge-to-total mass ratio and a systematic profile change from pseudo to classical bulges, as well as a significant reddening due to star formation fading in their disks. The Green Plain is also characterized by a maximum stellar mass of 10 11.7 M ⊙ beyond which only elliptical galaxies exist, hence supporting the scenario of ellipticals partly forming by major mergers of massive disk galaxies. Conclusions: The EFIGI attributes indicate that dynamical processes (spiral arms and isophote distortions) contribute to the scatter of the Main Sequence of star-forming galaxies (Blue Cloud), via the enhancement of star formation (flocculence, HII regions). The significant bulge growth across the Green Plain confirms that it is a transition region, and excludes a predominantly quick transit due to rapid quenching. The high frequency of bars for all spirals as well as the stronger spiral arms and flocculence in the knee of the Green Plain suggest that internal dynamics, likely triggered by flybys or (mainly minor) mergers, may be the key to the bulge growth of massive disk galaxies, which is a marker of the aging of galaxies from star forming to quiescence. The Hubble sequence can then be considered as an inverse sequence of galaxy physical evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Size controlled near-infrared high-quality PbSe quantum dots

Herein, we report the size controlled preparation of PbSe quantum dots (QDs) by non coordinating solvent route using oleic acid as surfactant molecules. The particles size is controlled by varying temperature and time of reaction. The present method of synthesis gives highly stable colloids, spherical in shape, better size tunability, narrow size distribution, extremely small size, monodisperse and exhibit strong near-infrared emission. The estimated particles sizes are in the range of 2 to 8 nm. These PbSe quantum dots are used for applications in optoelectronics and biological imaging.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $\$$50-$\$$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A discrete decentralized variable structure robotic controller

A decentralized trajectory controller for robotic manipulators is designed and tested using a multiprocessor architecture and a PUMA 560 robot arm. The controller is made up of a nominal model-based component and a correction component based on a variable structure suction control approach. The second control component is designed using bounds on the difference between the used and actual values of the model parameters. Since the continuous manipulator system is digitally controlled along a trajectory, a discretized equivalent model of the manipulator is used to derive the controller. The motivation for decentralized control is that the derived algorithms can be executed in parallel using a distributed, relatively inexpensive, architecture where each joint is assigned a microprocessor. Nonlinear interaction and coupling between joints is treated as a disturbance torque that is estimated and compensated for.

Tumeh, Zuheir S.↗

Building America Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts, Tyler, Texas

?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Novel Thermodynamical Predictor of Tropical High‐Cloud Area Coverage: Estimated Anvil‐Outflow Stability

The stability at the lapse-rate tropopause (LRT) was previously defined as the upper-tropospheric stability (UTS and SUT) but might underestimate the stability control on high-level clouds, since there is little direct connection between convective processes and the thermal stratification at the LRT. Here, a novel estimated anvil-outflow stability (EAS) based on the minimum stability in the upper troposphere is proposed. At the Manus site, the results show that small and large values of the LRT-based UTS and SUT both correspond to strong divergence and frequent occurrence of high-level ice clouds. In contrast, smaller EAS corresponds to stronger convective outflows to produce likely more high-level ice clouds, with a strong negative correlation. In tropics, EAS better explains the geographic distribution of high-level cloud coverage (HCC) and its temporal variations than UTS and SUT. With a strong linear correlation, EAS is likely a simple useful predictor of HCC.

54 ENVIRONMENTAL SCIENCES↗

SANS coupled with fluid invasion approaches for characterization of overall nanopore structure and mesopore connectivity of organic-rich marine shales in China

The pore structure of shales, including pore morphology, connectivity, pore volume, specific surface area (SSA), and pore size distribution (PSD), is a significant factor in controlling gas storage and transport and the migration mechanisms of hydrocarbons. However, the lack of comprehensive characterization for both accessible and inaccessible pore structure increases the difficulty of gas-in-place estimation and gas exploration. In order to investigate the nanoscale pore system, integration of high-pressure mercury intrusion porosimetry (MIP), low-pressure N 2 /CO 2 adsorption (LNA/LCA), and small-angle neutron scattering (SANS) were employed to obtain a multi-scale quantitative characterization of the nanopore structure of organic-rich marine shale samples from the Longmaxi and Niutitang Formations in China. In this work, PSDs obtained from the combined techniques appropriately cover an overall nanopore size range of shale (0.35–15,000 nm) and overcome the limits of the individual method. Uni-, bi, and multi-modal PSDs were observed, but the sizes of a significant portion of the nanopores observed in these shales range from 0.35 to 100 nm. Pore volumes and surface areas of micropores (<2 nm), mesopores (2–50 nm), and macropores (>50 nm) were characterized based on the best performance window of each technique: LCA for micropores; LNA and SANS for mesopores; and MIP for macropores. It was found that micropores are the major contributor to the total SSA for both the Longmaxi and Niutitang shales. With respect to pore volume, however, the contribution to the total pore volume has a trend of micropore < mesopore < macropore for the Longmaxi shale samples, but micro-/mesopore volumes are greater than macropore volumes for samples of the Niutitang shale. Strong correlations were also observed between total organic carbon (TOC) content and micropore volume and surface area, which implies that organic matter is a controlling factor in the micropore system of organic-rich shales. In addition, strong correlations between methane adsorption capacity and both micro-/mesopore volumes and SSAs indicate that micro-/mesopores are governing factors for methane storage. Furthermore, the fractions of accessible mesopore volume and surface area were quantitatively estimated by SANS and LNA. Correlation analyses suggest that the accessibility of the mesopore surface area could be an indicator for gas transport and storage in mesopores in organic matter. Thus, a shale with higher connectivity could have higher gas diffusion capability but lower gas adsorption capacity, and vice versa.

58 GEOSCIENCES↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Relationships between digital signal processing and control and estimation theory

Research areas associated with digital signal processing and control and estimation theory are identified. Particular attention is given to image processing, system identification problems (parameter identification, linear prediction, least squares, Kalman filtering), stability analyses (the use of the Liapunov theory, frequency domain criteria, passivity), and multiparameter systems, distributed processes, and random fields.

Willsky, A. S.↗

The Sensitivity of African Easterly Waves to Eastern Tropical Atlantic Sea-Surface Temperatures

The results of two regional atmospheric model simulations are compared to assess the influence of the eastern tropical Atlantic sea-surface temperature maximum on local precipitation, transient easterly waves and the West African summer monsoon. Both model simulations were initialized with reanalysis 2 data (US National Center for Environmental Prediction and Department of Energy) on 15 May 2006 and extended through 6 October 2006, forced by synchronous reanalysis 2 lateral boundary conditions introduced four times daily. One simulation uses 2006 reanalysis 2 sea-surface temperatures, also updated four times daily, while the second simulation considers ocean forcing absent the sea-surface temperature maximum, achieved here by subtracting 3 K at every ocean grid point between 0 and 15 N during the entire simulation. The simulation with 2006 sea-surface temperature forcing produces a realistic distribution of June-September mean precipitation and realistic westward propagating swaths of maximum rainfall, based on validation against Tropical Rainfall Measuring Mission (TRMM) estimates. The simulation without the sea-surface temperature maximum produces only 57% of the control June-September total precipitation over the eastern tropical Atlantic and about 83% of the Sahel precipitation. The simulation with warmer ocean temperatures generates generally stronger circulation, which in turn enhances precipitation by increasing moisture convergence. Some local precipitation enhancement is also attributed to lower vertical thermal stability above the warm water. The study shows that the eastern tropical Atlantic sea-surface temperature maximum enhances the strength of transient easterly waves and broadens the spatial extent of associated precipitation. However, large-scale circulation and its interaction with the African continent, and not sea-surface temperatures, control the timing and trajectories of the waves.

Druyan, Leonard M.↗

High-Resolution Near-Surface Imaging at the Basin Scale Using Dark Fiber and Distributed Acoustic Sensing: Toward Site Effect Estimation in Urban Environments

Near-surface seismic structure, particularly the shear wave velocity (V s ), can strongly affect local site response, and should be accurately estimated for ground motion prediction during seismic hazard assessment. The Imperial Valley (California), occupying the southern end of the Salton Trough, is a seismically active basin with thick surficial lacustrine sedimentary deposits. In this study, we utilize ambient noise records and local earthquake events for high-resolution near-surface characterization and site effect estimation with an unlit fiber-optic telecommunication infrastructure (dark fiber) in Imperial Valley by using the distributed acoustic sensing (DAS) technique. We apply ambient noise interferometry to retrieve coherent surface waves from DAS records, and evaluate performances of three different surface wave methods on DAS ambient noise dispersion imaging. We develop a quality control workflow to improve the dispersion measurement of noisy portions of the DAS data set by using a data selection strategy. Using the joint inversion of both the fundamental mode and higher overtones of Rayleigh waves, a high resolution two-dimensional (2D) V s structure down to 70 m depth is obtained. We successfully achieve an improved V s 30 (the time-averaged shear-wave velocity in the top 30 m) model with higher spatial-resolution and reliability compared to the existing community model for the area. We also explore the potential for utilizing DAS earthquake events for site amplification estimation. The preliminary results reveal a clear anti-correlation between the approximated site response and the V s 30 profile. In conclusion, our results indicate the potential utility of DAS deployed on dark fiber for near-surface characterization in appropriate contexts.

58 GEOSCIENCES↗

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determinethe number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging towardutility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetrationscenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗