Search NASA⌕ Search

SEARCH · Search NASA

Results for “doppler effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

High resolution ion Doppler spectroscopy at Prairie View Rotamak

A fast ion Doppler spectroscopy (IDS) diagnostic system is installed on the Prairie View Rotamak to measure ion temperature and plasma flow. The diagnostic employs a single channel photomultiplier tube and a Jarrell-Ash 50 monochromator with a diffraction grating line density of 1180 lines/mm, which allows for first order spectra of 200-600 nm. The motorized gear of the monochromator allows spectral resolution of 0.01 nm. Equal IDS measurements are observed for various impurity emission lines of which carbon lines exhibit stronger intensities. Furthermore, the diagnostics is examined in an experiment where plasma experiences sudden disruption and quick recovery. In this case, the IDS measurements show {approx}130% increase in ion temperature. Flow measurements are shown to be consistent with plasma rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density fluctuation measurements by far-forward collective scattering in the MST reversed-field pinch

The multichannel polarimeter-interferometer system on the MST reversed-field pinch can be utilized to measure far-forward collective scattering from electron density fluctuations. The collective scattering system has 11 viewing chords with {approx}8 cm spacing. The source is a 432 {mu}m (694 GHz) far infrared laser and the scattered power is measured using a heterodyne detection scheme. Collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k{sub Up-Tack} < 1.3 cm{sup -1}, corresponding k{sub Up-Tack }{rho}{sub s} < 1.3 ({rho}{sub s} is the ion-sound Larmor radius), the region of primary interest for turbulent fluctuation-induced transport. The perpendicular wavenumber consists of toroidal, poloidal, and radial contributions, which vary with chord position. Coherent modes associated with tearing instabilities and neutral-beam driven fast particles are observed along with broadband turbulence at frequencies up to 500 kHz. Changes in frequency are consistent with a Doppler shift due to parallel plasma flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isorotation and differential rotation in a magnetic mirror with imposed E Multiplication-Sign B rotation

Doppler spectroscopy of helium impurities in the Maryland Centrifugal Experiment reveals the simultaneous existence of isorotating and differentially rotating magnetic surfaces. Differential rotation occurs at the innermost surfaces and is conjectured to cause plasma voltage oscillations of hundreds of kilohertz by periodically changing the current path inductance. High-speed images show the periodic expulsion of plasma near the mirror ends at the same frequencies. In spite of this, the critical ionization velocity limit is exceeded, with respect to the vacuum field definition, for at least 0.5 ms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high etendue spectrometer suitable for core charge eXchange recombination spectroscopy on ITER

A feasibility study for the use of core charge exchange recombination spectroscopy on ITER has shown that accurate measurements on the helium ash require a spectrometer with a high etendue of 1mm{sup 2}sr to comply with the measurement requirements [S. Tugarinov et al., Rev. Sci. Instrum. 74, 2075 (2003)]. To this purpose such an instrument has been developed consisting of three separate wavelength channels (to measure simultaneously He/Be, C/Ne, and H/D/T together with the Doppler shifted direct emission of the diagnostic neutral beam, the beam emission (BES) signal), combining high dispersion (0.02 nm/pixel), sufficient resolution (0.2 nm), high efficiency (55%), and extended wavelength range (14 nm) at high etendue. The combined measurement of the BES along the same sightline within a third wavelength range provides the possibility for in situ calibration of the charge eXchange recombination spectroscopy signals. In addition, the option is included to use the same instrument for measurements of the fast fluctuations of the beam emission intensity up to 2 MHz, with the aim to study MHD activity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of neutral beam energy fractions from collisional radiative measurements on DIII-D

Neutral beams based on positive ion source technology are a key component of contemporary fusion research. An accurate assessment of the injected beam species mix is important for determining the actual plasma heating and momentum input as well as proper interpretation of beam-based diagnostics. On DIII-D, the main ion charge-exchange spectroscopy system is used to extract well-resolved intensity ratios of the Doppler-shifted D{sub {alpha}} emission from the full, half, and third energy beam components for a variety of beam operational parameters. In conjunction with accurate collisional-radiative modeling, these measurements indicate the assumed species mix and power fractions can vary significantly and should be regularly monitored and updated for the most accurate interpretation of plasma performance. In addition, if stable active control of the power fractions can be achieved through appropriate source tuning, the resulting control over the deposition profile can serve as an additional experimental knob for advanced tokamak studies, e.g., varying the off axis beam current drive without altering the beam trajectory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of spatially resolved high resolution crystal spectrometry to inertial confinement fusion plasmas

High resolution ({lambda}/{Delta}{lambda}{approx} 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-{mu}m {sup 55}Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10{sup -8}-10{sup -6} times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrades of the high resolution imaging x-ray crystal spectrometers on experimental advanced superconducting tokamak

Two imaging x-ray crystal spectrometers, the so-called 'poloidal' and 'tangential' spectrometers, were recently implemented on experimental advanced superconducting tokamak (EAST) to provide spatially and temporally resolved impurity ion temperature (T{sub i}), electron temperature (T{sub e}) and rotation velocity profiles. They are derived from Doppler width of W line for Ti, the intensity ratio of Li-like satellites to W line for Te, and Doppler shift of W line for rotation. Each spectrometer originally consisted of a spherically curved crystal and a two-dimensional multi-wire proportional counter (MWPC) detector. Both spectrometers have now been upgraded. The layout of the tangential spectrometer was modified, since it had to be moved to a different port, and the spectrometer was equipped with two high count rate Pilatus detectors (Model 100 K) to overcome the count rate limitation of the MWPC and to improve its time resolution. The poloidal spectrometer was equipped with two spherically bent crystals to record the spectra of He-like and H-like argon simultaneously and side by side on the original MWPC. These upgrades are described, and new results from the latest EAST experimental campaign are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of parallel electron velocity distributions using whistler wave absorption

We describe a diagnostic to measure the parallel electron velocity distribution in a magnetized plasma that is overdense ({omega}{sub pe} > {omega}{sub ce}). This technique utilizes resonant absorption of whistler waves by electrons with velocities parallel to a background magnetic field. The whistler waves were launched and received by a pair of dipole antennas immersed in a cylindrical discharge plasma at two positions along an axial background magnetic field. The whistler wave frequency was swept from somewhat below and up to the electron cyclotron frequency {omega}{sub ce}. As the frequency was swept, the wave was resonantly absorbed by the part of the electron phase space density which was Doppler shifted into resonance according to the relation {omega}-k{sub ||v||} = {omega}{sub ce}. The measured absorption is directly related to the reduced parallel electron distribution function integrated along the wave trajectory. The background theory and initial results from this diagnostic are presented here. Though this diagnostic is best suited to detect tail populations of the parallel electron distribution function, these first results show that this diagnostic is also rather successful in measuring the bulk plasma density and temperature both during the plasma discharge and into the afterglow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stochastic mechanism of electron heating

Due to Landau resonant interaction with lower hybrid waves in the lower hybrid current drive scheme part of electrons are accelerated and, as a result of this, a tail of energetic electrons is formed on the electron distribution function. The same situation takes place in the problem of type III radio bursts when the suprathermal burst electrons acquire a plateau distribution due to excitation of plasma waves in the solar wind plasma. These distributions are unstable with respect to the cyclotron excitation of waves at anomalous Doppler resonance ('fan' instability). In this case, the tail electrons interact simultaneously with both (i) waves that accelerate or decelerate them (Cerenkov resonance) and (ii) waves excited in the process of the fan instability that led to their pitch angle diffusion. Because velocity diffusion lines of electrons formed due to heir interaction with each type of waves intersect, this interaction can lead not only to pitch angle diffusion but also to heating of electrons mainly in perpendicular direction. We investigated this mechanism of electron heating and studied the temporal evolution of the electron temperature and the energy of excited waves. Our results show significant enhancement of the electron perpendicular temperature T{sub Up-Tack} due to this stochastic heating mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactive quenching of OH A {sup 2}{Sigma}{sup +} by O{sub 2} and CO: Experimental and nonadiabatic theoretical studies of H- and O-atom product channels

The outcomes following collisional quenching of electronically excited OH A {sup 2}{Sigma}{sup +} by O{sub 2} and CO are examined in a combined experimental and theoretical study. The atomic products from reactive quenching are probed using two-photon laser-induced fluorescence to obtain H-atom Doppler profiles, O ({sup 3}P{sub J}) atom fine structure distributions, and the relative yields of these products with H{sub 2}, O{sub 2}, and CO collision partners. The corresponding H-atom translational energy distributions are extracted for the H + O{sub 3} and H + CO{sub 2} product channels, in the latter case revealing that most of the available energy is funneled into internal excitation of CO{sub 2}. The experimental product branching ratios show that the O-atom producing pathways are the dominant outcomes of quenching: the OH A {sup 2}{Sigma}{sup +}+ O{sub 2}{yields} O + HO{sub 2} channel accounts for 48(3)% of products and the OH A {sup 2}{Sigma}{sup +}+ CO {yields} O + HCO channel yields 76(5)% of products. In addition, quenching of OH A {sup 2}{Sigma}{sup +} by O{sub 2} generates H + O{sub 3} products [12(3)%] and returns OH to its ground X {sup 2}{Pi} electronic state [40(1)%; L. P. Dempsey, T. D. Sechler, C. Murray, and M. I. Lester, J. Phys. Chem. A 113, 6851 (2009)]. Quenching of OH A {sup 2}{Sigma}{sup +} by CO also yields H + CO{sub 2} reaction products [26(5)%]; however, OH X {sup 2}{Pi} (v{sup Double-Prime }= 0,1) products from nonreactive quenching are not observed. Theoretical studies characterize the properties of energy minimized conical intersections in four regions of strong nonadiabatic coupling accessible from the OH A {sup 2}{Sigma}{sup +}+ CO asymptote. Three of these regions have the O-side of OH pointing toward CO, which lead to atomic H and vibrationally excited CO{sub 2} products and/or nonreactive quenching. In the fourth region, energy minimized points are located on a seam of conical intersection from the OH A {sup 2}{Sigma}{sup +}+ CO asymptote to an energy minimized crossing with an extended OH bond length and the H-side of OH pointing toward CO in a bent configuration. This region, exoergic with respect to the reaction asymptote, is likely to be the origin of the dominant O + HCO product channel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lifetime measurements of high-lying short lived states in {sup 69}As

Lifetimes of high-spin states in {sup 69}As have been measured using Doppler shift attenuation technique with the GASP and RFD setup. The determined transition probabilities indicate large deformation associated with some rotational bands in this nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Note: Simultaneous measurement of transverse speed and axial velocity from a single optical beam

A method is introduced for simultaneously measuring transverse speed and axial velocity using a single optical beam and a standard photon Doppler velocimetry (PDV) sensing architecture. This result is of particular interest given the recent, widespread use of PDV and the fact that optical velocimetry has thus far been limited to measuring motion in one dimension per probe. Further, this result demonstrates that both axial velocity data and transverse speed data (at least qualitative) may be obtained entirely through signal analysis; not requiring hardware modification. This result is immediately relevant to analyses of existing PDV data and to future efforts in high-speed optical velocimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring time of flight of fusion products in an inertial electrostatic confinement fusion device for spatial profiling of fusion reactions

A new diagnostic has been developed that uses the time of flight (TOF) of the products from a nuclear fusion reaction to determine the location where the fusion reaction occurred. The TOF diagnostic uses charged particle detectors on opposing sides of the inertial electrostatic confinement (IEC) device that are coupled to high resolution timing electronics to measure the spatial profile of fusion reactions occurring between the two charged particle detectors. This diagnostic was constructed and tested by the University of Wisconsin-Madison Inertial Electrostatic Confinement Fusion Group in the IEC device, HOMER, which accelerates deuterium ions to fusion relevant energies in a high voltage ({approx}100 kV), spherically symmetric, electrostatic potential well [J. F. Santarius, G. L. Kulcinski, R. P. Ashley, D. R. Boris, B. B. Cipiti, S. K. Murali, G. R. Piefer, R. F. Radel, T. E. Radel, and A. L. Wehmeyer, Fusion Sci. Technol. 47, 1238 (2005)]. The TOF diagnostic detects the products of D(d,p)T reactions and determines where along a chord through the device the fusion event occurred. The diagnostic is also capable of using charged particle spectroscopy to determine the Doppler shift imparted to the fusion products by the center of mass energy of the fusion reactants. The TOF diagnostic is thus able to collect spatial profiles of the fusion reaction density along a chord through the device, coupled with the center of mass energy of the reactions occurring at each location. This provides levels of diagnostic detail never before achieved on an IEC device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Behaviour and stability of Trivelpiece-Gould modes in non-neutral plasma containing small density fraction of background gas ions

It is shown that the frequencies of Trivelpiece-Gould (TG) modes in non-neutral plasma can get into the low-frequency range due to the Doppler shift caused by plasma rotation in crossed fields. TG modes interact with the ion modes that leads to plasma instability. In paper the frequency spectrum of 'cold' electron plasma completely filling a waveguide and containing small density fraction of ions of background gas is determined numerically. For ions the kinetic description is used. Oscillations having azimuthal number m= 2 are considered. In this case both low- and upper-hybrid TG modes get into the low-frequency range. The spectrum consists of families of 'modified' ion cyclotron (MIC) modes and electron TG modes with the frequencies equal to hybrid frequencies with the Doppler shift. The growth rates of upper-hybrid modes are much faster than the growth rates of low-hybrid and MIC modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-linear modulation of short wavelength compressional Alfven eigenmodes

Most Alfvenic activity in the frequency range between toroidal Alfven eigenmodes and roughly one half of the ion cyclotron frequency on National Spherical Torus eXperiment [Ono et al., Nucl. Fusion 40, 557 (2000)], that is, approximately 0.3 MHz up to Almost-Equal-To 1.2 MHz, are modes propagating counter to the neutral beam ions. These have been modeled as Compressional and Global Alfven Eigenmodes (CAE and GAE) and are excited through a Doppler-shifted cyclotron resonance with the beam ions. There is also a class of co-propagating modes at higher frequency than the counter-propagating CAE and GAE. These modes have been identified as CAE, and are seen mostly in the company of a low frequency, n = 1 kink-like mode. In this paper, we present measurements of the spectrum of these high frequency CAE (hfCAE) and their mode structure. We compare those measurements to a simple model of CAE and present a predator-prey type model of the curious non-linear coupling of the hfCAE and the low frequency kink-like mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision lifetime measurements of exotic nuclei based on Doppler-shift techniques

A recent progress in precision lifetime measurements of exotic nuclei at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University is presented. The Recoil Distance Doppler-shift (RDDS) technique has been applied to nuclear reactions involving intermediate-energy rare isotope (RI) beams, to determine absolute transition strengths between nuclear states model independently from level lifetimes of interest. As such an example, recent lifetime measurements of the first 2{sup +} states in the neutron-rich {sup 62,64,66}Fe isotopes at and around N=40 are introduced. The experiment was performed at the Coupled Cyclotron Facility at NSCL using a unique combination of several experimental instruments; the Segmented Germanium Array (SeGA), the plunger device, and the S800 spectrograph. The reduced E2 transition probabilities B(E2) are determined directly from the measured lifetimes. The observed trend of B(E2) clearly demonstrates that an enhanced collectivity persists in {sup 66}Fe despite the harmonic-oscillator magic number N=40. The present results are also discussed in comparison with the large-scale shell model calculations, pointing to a possible extension of the deformation region beyond N=40.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status and characterization of the lithium beam diagnostic on DIII-D

The 30 keV lithium beam diagnostic on DIII-D is suitable to measure both the radial electron density and poloidal magnetic field profiles in the pedestal. The refurbished system features a new setup to measure the Doppler shift allowing accurate alignment of the spectral filters. The injector has been optimized to generate a stable lithium neutral beam with a current of I= 15−20 mA and a diameter of 1.9 ± 0.1 cm measured by beam imaging. The typical temporal resolution is Δt= 1−10 ms and the radial resolution of ΔR= 5 mm is given by the optical setup. A new analysis technique based on fast Fourier transform avoids systematic error contributions from the digital lock-in analysis and accounts intrinsically for background light correction. Latest upgrades and a detailed characterization of the system are presented. Proof-of-principle measurements of the poloidal magnetic field with a statistical error of typically 2% show a fair agreement with the predictions modeled with the Grad-Shafranov equilibrium solver EFIT within 4%.

43 PARTICLE ACCELERATORS↗

Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade

A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as D{sub 2}-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗