Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

DOE Residential Energy Code Field Study - Pennsylvania

This project consisted of three distinct phases – all focused on residential one- and two-family dwellings and townhouses. Phase 1 included a baseline field study with inspections and performance testing to assess construction practices with respect to the energy code. PNNL used the data to perform EUI and savings potential analyses. Phase 2 consisted of training, education, and outreach to building industry professionals with content based on the findings from Phase 1. Phase 3 was a post-program field study using the same methodology as Phase 1 and was intended to measure the impact of Phase 2. During Phase 1 of the project, PSD collected data from 171 job sites across eastern Pennsylvania, a territory bounded by PECO, PPL, and Met-Ed electric distribution territories, to reach the required 63 “home equivalents” deemed necessary by PNNL for a representative sample. Based on subsequent analysis, four key items were identified as having significant savings potential from improvement in compliance, including duct leakage, above-grade wall insulation (specifically insulation installation quality), foundation insulation, and high-efficacy lighting. About half the total savings potential is from duct leakage, so that was the primary focus. The goal of Phase 2 was to improve upon these key compliance weaknesses through an intensive training, education, and outreach program. PSD dubbed this effort the Penn Energy Codes Program. For Phase 3, PSD obtained a new sample plan from PNNL, obtained permit data from sample municipalities, and made substitutions where necessary. PSD field staff visited 165 job sites to collect the required 504 key observations. PSD submitted all data collection sheets to PNNL for their analysis to determine if there was a measurable change due to Phase 2 activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A generalized implicit algorithm for multi-dimensional particle-in-cell simulations in Cartesian geometry

An implicit multi-dimensional particle-in-cell (PIC) code is developed to study the interaction of ultrashort pulse lasers with matter. The algorithm is based on current density decomposition and is only marginally more complicated compared to explicit PIC codes, but it completely eliminates grid heating and possesses good energy conserving properties with relaxed time step and grid resolution. This is demonstrated in a test case study, in which high-energy protons are generated from a thin carbon foil at solid density using linear and circular polarizations. The grid heating rate is estimated to be 1-10 eV/ps.

36 MATERIALS SCIENCE↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Performance Rating Method - Review of Existing Tools, Rulesets, and Programs. Literature and technical review

The Performance Rating Method (PRM) in ASHRAE Standard 90.1 (ASHRAE 2016) is a simulation ruleset for establishing minimum code compliance and for rating a building’s beyond-code applications. Building energy modeling (BEM) to comply with the PRM is often expensive and time consuming due to the complexity of code requirements. The goal of this project is to develop and codify a simplified PRM (S-PRM) approach for commercial buildings that will expand the use of BEM for small or simple buildings by defining a low-cost, simplified approach for creating robust and detailed models. This report summarizes a review of (i) the more commonly used existing codes, (ii) incentive programs, and (iii) the existing simplified energy modeling tools to identify which requirements are good candidates for simplification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings (Rev. 1)

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Perspective of Decarbonization Pathways in Future Buildings in the United States

The commitment of electrification and decarbonization goals in the United States (U.S.) will significantly change the performance of future buildings. To meet these goals, it is critical to summarize the existing research related to building electrification and decarbonization and discuss future research pathways. This paper provides a perspective on decarbonization pathways of future buildings in the U.S. A critical review of the existing research was conducted, which is divided into three closely linked categories: technologies, economic impacts, and code regulations. Technologies support investments and code regulations while marketing affects the design of building codes and standards. In the meantime, code regulations guide the development of technologies and marketing. Based on the review, future potential research directions for building decarbonization are then discussed. Due to the needs of building decarbonization, future research will be multidisciplinary, conducted at a large geographic scale, and involve a multitude of metrics, which will undoubtedly introduce new challenges. The perspective presented in this paper will provide policy-makers, researchers, building owners, and other stakeholders with a way to understand the impact of electrification and decarbonization of future buildings in the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of density fluctuations during the search for an I-mode regime on the DIII-D tokamak

The I-mode regime, routinely observed on the Alcator C-Mod tokamak, is characterized by an edge energy transport barrier without an accompanying particle barrier and with broadband instabilities, known as weakly coherent modes (WCM), believed to regulate particle transport at the edge. Recent experiments on the DIII-D tokamak exhibit I-mode characteristics in various physical quantities. These DIII-D plasmas evolve over long periods, lasting several energy confinement times, during which the edge electron temperature slowly evolves towards an H-mode-like profile, while maintaining a typical L-mode edge density profile. During these periods, referred to as I-mode phases, the radial electric field at the edge also gradually reaches values typically observed in H-mode. Density fluctuations measured with the phase contrast imaging diagnostic during I-mode phases exhibit three features typically observed in H-mode on DIII-D, although they develop progressively with time and without a sharp transition: the intensity of the fluctuations is reduced; the frequency spectrum is broadened and becomes non-monotonic; two dimensional space-time spectra appear to approach those in H-mode, showing phase velocities of density fluctuations at the edge increasing to about 10 km s -1 . However, in DIII-D there is no clear evidence of the WCM. Preliminary linear gyro-kinetic simulations are performed in the pedestal region with the GS2 code and its recently upgraded model collision operator that conserves particles, energy and momentum. The increased bootstrap current and flow shear generated by the temperature pedestal are shown to decrease growth rates, thus possibly generating a feedback mechanism that progressively stabilizes fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling Windows in Energy Plus with Simple Performance Indices

The building energy simulation program, Energy Plus (E+), cannot use standard window performance indices (U, SHGC, VT) to model window energy impacts. Rather, E+ uses more accurate methods which require a physical description of the window. E+ needs to be able to accept U and SHGC indices as window descriptors because, often, these are all that is known about a window and because building codes, standards, and voluntary programs are developed using these terms. This paper outlines a procedure, developed for E+, which will allow it to use standard window performance indices to model window energy impacts. In this 'Block' model, a given U, SHGC, VT are mapped to the properties of a fictitious 'layer' in E+. For thermal conductance calculations, the 'Block' functions as a single solid layer. For solar optical calculations, the model begins by defining a solar transmittance (Ts) at normal incidence based on the SHGC. For properties at non-normal incidence angles, the 'Block' takes on the angular properties of multiple glazing layers; the number and type of layers defined by the U and SHGC. While this procedure is specific to E+, parts of it may have applicability to other window/building simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Symmetry boundary conditions

A simple approach to energy conserving boundary conditions using exact symmetries is described which is especially useful for numerical simulations using the finite difference method. Each field in the simulation is normally either symmetric (even) or antisymmetric (odd) with respect to the simulation boundary. Another possible boundary condition is an antisymmetric perturbation about a nonzero value. One of the most powerful aspects of this approach is that it can be easily implemented in curvilinear coordinates by making the scale factors of the coordinate transformation symmetric about the boundaries. The method is demonstrated for magnetohydrodynamics (MHD), reduced MHD, and a hybrid code with particle ions and fluid electrons. These boundary conditions yield exact energy conservation in the limit of infinite time and space resolution. Also discussed is the interpretation that the particle charge reverses sign at a conducting boundary with boundary normal perpendicular to the background magnetic field.

97 MATHEMATICS AND COMPUTING↗

High Performance Walls in Hot-Dry Climates

High performance walls represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. The primary goal in improving wall thermal performance revolves around increasing the wall framing from 2x4 to 2x6, adding more cavity and exterior rigid insulation, achieving insulation installation criteria meeting ENERGY STAR's thermal bypass checklist. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of high performance wall systems. Builders were given incentives and design support in exchange for providing site access for construction observation, cost information, and builder survey feedback. Information from the project was designed to feed into the 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project utilized information collected in the California project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodological Framework for Analysis of Buildings-Related Programs with BEAMS, 2008

The U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) develops official “benefits estimates” for each of its major programs using its Planning, Analysis, and Evaluation (PAE) Team. PAE conducts an annual integrated modeling and analysis effort to produce estimates of the energy, environmental, and financial benefits expected from EERE’s budget request. These estimates are part of EERE’s budget request and are also used in the formulation of EERE’s performance measures. Two of EERE’s major programs are the Building Technologies Program (BT) and the Weatherization and Intergovernmental Program (WIP). Pacific Northwest National Laboratory (PNNL) supports PAE by developing the program characterizations and other market information necessary to provide input to the EERE integrated modeling analysis as part of PAE’s Portfolio Decision Support (PDS) effort. Additionally, PNNL also supports BT by providing line-item estimates for the Program’s internal use. PNNL uses three modeling approaches to perform these analyses. This report documents the approach and methodology used to estimate future energy, environmental, and financial benefits using one of those methods: the Building Energy Analysis and Modeling System (BEAMS). BEAMS is a PC-based accounting model that was built in Visual Basic by PNNL specifically for estimating the benefits of buildings-related projects. It allows various types of projects to be characterized including whole-building, envelope, lighting, and equipment projects. This document contains an overview section that describes the estimation process and the models used to estimate energy savings. The body of the document describes the algorithms used within the BEAMS software. This document serves both as stand-alone documentation for BEAMS, and also as a supplemental update of a previous document, Methodological Framework for Analysis of Buildings-Related Programs: The GPRA Metrics Effort, (Elliott et al. 2004b). The areas most changed since the publication of that previous document are those discussing the calculation of lighting and HVAC interactive effects (for both lighting and envelope/whole-building projects). This report does not attempt to convey inputs to BEAMS or the methodology of their derivation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Support Document: Development of the Advanced Energy Design Guide for Medium Box Retail -- 50% Energy Savings

This report provides recommendations that architects, designers, contractors, developers, owners, and lessees of medium box retail buildings can use to achieve whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004. The recommendations are given by climate zone and address building envelope, fenestration, lighting systems, HVAC systems, building automation and controls, outside air treatment, service water heating, plug loads, and photovoltaic systems. The report presents several paths to 50% savings, which correspond to different levels of integrated design. These are recommendations only, and are not part of a code or standard. The recommendations are not exhaustive, but we do try to emphasize the benefits of integrated building design, that is, a design approach that analyzes a building as a whole system, rather than as a disconnected collection of individually engineered subsystems.

14 SOLAR ENERGY↗

A NUMERICAL METHOD FOR STUDYING SUPER-EDDINGTON MASS TRANSFER IN DOUBLE WHITE DWARF BINARIES

We present a numerical method for the study of double white dwarf (DWD) binary systems at the onset of super-Eddington mass transfer. We incorporate the physics of ideal inviscid hydrodynamical flow, Newtonian self-gravity, and radiation transport on a three-dimensional uniformly rotating cylindrical Eulerian grid. Care has been taken to conserve the key physical quantities such as angular momentum and energy. Our new method conserves total energy to a higher degree of accuracy than other codes that are presently being used to model mass transfer in DWD systems. We present the results of verification tests and simulate the first 20 + orbits of a binary system of mass ratio q 0.7 at the onset of dynamically unstable direct impact mass transfer. The mass transfer rate quickly exceeds the critical Eddington limit by many orders of magnitude, and thus we are unable to model a trans-Eddington phase. It appears that radiation pressure does not significantly affect the accretion flow in the highly super-Eddington regime. An optically thick common envelope forms around the binary within a few orbits. Although this envelope quickly exceeds the spatial domain of the computational grid, the fraction of the common envelope that exceeds zero gravitational binding energy is extremely small, suggesting that radiation-driven mass loss is insignificant in this regime. It remains to be seen whether simulations that capture the trans-Eddington phase of such flows will lead to the same conclusion or show that substantial material gets expelled.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep Energy Retrofit Guidance for the Building America Solutions Center

The U.S. DOE Building America program has established a research agenda targeting market-relevant strategies to achieve 40% reductions in existing home energy use by 2030. Deep Energy Retrofits (DERs) are part of the strategy to meet and exceed this goal. DERs are projects that create new, valuable assets from existing residences, by bringing homes into alignment with the expectations of the 21st century. Ideally, high energy using, dated homes that are failing to provide adequate modern services to their owners and occupants (e.g., comfortable temperatures, acceptable humidity, clean, healthy), are transformed through comprehensive upgrades to the building envelope, services and miscellaneous loads into next generation high performance homes. These guidance documents provide information to aid in the broader market adoption of DERs. They are intended for inclusion in the online resource the Building America Solutions Center (BASC). This document is an assemblage of multiple entries in the BASC, each of which addresses a specific aspect of Deep Energy Retrofit best practices for projects targeting at least 50% energy reductions. The contents are based upon a review of actual DERs in the U.S., as well as a mixture of engineering judgment, published guidance from DOE research in technologies and DERs, simulations of cost-optimal DERs, Energy Star and Consortium for Energy Efficiency (CEE) product criteria, and energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Annual Energy Savings and Peak Power Reduction Simulated for CCHP Design and Baseline HP in Cold Climate Cities

This report assesses energy savings and peak power reduction of three heat pumps in multiple US cold climate cities and building types. The three heat pumps comprise a baseline heat pump and two high efficiency cold climate heat pumps (CCHP). The DOE/ORNL Heat Pump Design Model was used to simulate the heat pumps and generate performance curves for EnergyPlus building energy simulations. The annual energy simulations were performed over seven cold climates: 1) Minneapolis, MN; 2) Duluth, MN; 3) Fairbanks, AK; 4) Helena, MT; 5) Indianapolis, IN; 6) Peoria, IL and 7) Eagle County, CO. In order to assess impact of residential building types matching different energy codes, we simulated six single-family houses in Indianapolis, IN, including : 1) single-family house having a crawlspace; 2) having a slab foundation; 3) having a heated basement; 4) having an unheated basement; 5) one single-family house having a heated basement matching IECC code of 2009, 6) and one single-family house having a heated basement matching IECC code of 2012. The former 4 houses match the IECC 2006 code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Datacenter Automation Software and Hardware (DASH) at the California Franchise Tax Board

Control software and wireless sensors designed for closed-loop, monitoring and control of IT equipment's inlet air temperatures in datacenters were evaluated and tested while other datacenter cooling best practices were implemented. The controls software and hardware along with each best practice were installed sequentially and evaluated using a measurement and verification procedure between each measure. The results show that the overall project eliminates 475,239 kWh per year, which is 21.3percent of the baseline energy consumption of the data center. The total project, including the best practices will save $42,772 per year and cost $134,057 yielding a simple payback of 3.1 years. However, the control system alone eliminates 59.6percent of the baseline energy used to move air in the datacenter and 13.6percent of the baseline cooling energy, which is 15.2percent of the baseline energy consumption (see Project Approach, Task 1, below, for additional information) while keeping temperatures substantially within the limits recommended by ASHRAE. Savings attributed to the control system are $30,564 per year with a cost $56,824 for a simple payback of 1.9 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗