Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Strategic Planning for Energy-Resilient Communities

Distributed energy resources (DERs) offer flexibility and community benefits in both blue- and black-sky conditions. Outside of a power disruption, they can provide significant cost savings and reduce grid stress during times of high demand. During a disruption to the central grid, these technologies can meet critical energy needs through the use of battery storage. However, communities must consider many planning and design dimensions and tradeoffs to integrate energy systems that meet financial and resilience goals. This presentation, given at the 2026 State Energy Conference of North Carolina, defines resilience in an energy context, discusses strategies and best practices for planning resilient energy systems and sites, including resilience hubs and microgrids, highlights NLR tools and capabilities for helping communities in this space, and features successful case studies in North Carolina related to energy resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pumped Storage Hydropower (PSH) FAST Commissioning Prize Technical Analysis

The US energy landscape has undergone major changes over the past 10 years and will continue to see significant changes in future decades as the power grid increases its reliance on variable renewable energy resources. Because of the inherent variability of these resources, renewable energy growth may require additional energy storage capacity to provide flexible load-following capabilities and other grid services that can quickly adjust to changes in energy demand and generation. Pumped storage hydropower (PSH)—one such energy storage technology—uses pumps to convey water from a lower reservoir to an upper reservoir for energy storage and releases water back to the lower reservoir via a powerhouse for hydropower generation. PSH facility pump and generation cycling often follows economic and energy demand conditions. Across the United States, 43 PSH facilities are in operation and 55 projects are in various permitting or licensing stages. Altogether, the 43 operational projects provide the wide majority (95%) of utility-scale electricity storage in the United States. These facilities also provide significant power and nonpower grid benefits, including large-scale electrical system reserve capacity, grid reliability support, and electricity supply-demand balancing through quick-response capabilities and operational flexibility. PSH systems can accomplish these at a scale (e.g., size) and cost that makes these systems highly attractive from a technical standpoint. Although these research concepts are still in their infancy, they demonstrate promising potential as future PSH energy storage technologies. Although PSH has many advantages, development in the United States has effectively stalled since the 1990s, partially because of the magnitude of project costs and financing interest during development and construction, the length of time from project investment until project revenue begins, permitting challenges, construction risks, competition from other storage technologies (e.g., batteries, hydrogen storage), and electricity market evolution and uncertainty. In short, the time, cost, and risk associated with modern PSH development have resulted in limited growth in the United States recently, despite the growing energy storage demand stemming from increased wind and solar power deployment. Technology innovation is needed to help reduce PSH commissioning time, cost, and risk, particularly during the post-licensing phase of project development. To address challenges facing the PSH industry and to improve PSH commissioning timelines, the US Department of Energy (DOE) Water Power Technologies Office (WPTO) initiated the PSH Furthering Advancements to Shorten Time to (FAST) Commissioning Prize project.

13 HYDRO ENERGY↗

Performance analysis of integrated Nuclear-Solar Energy system sharing same molten salt thermal energy storage

Advanced nuclear reactors may be deployed with integrated thermal energy storage to improve flexibility and maximize revenue. This presents opportunities for thermal integration with concentrating solar power (CSP) to generate component synergies and/or improve performance. Here in this study, a computational model is developed for an integrated nuclear and CSP system that both share the same molten salt thermal energy storage (TES). Optimized dispatch schedules are developed subject to various market conditions, and the ratio of the nuclear to CSP thermal output is also varied. Performance of the combined system is compared to separate nuclear and solar plants, to determine if there is an overall benefit that can be derived from sharing the TES. Given sufficient volatility in electricity prices (e.g., under CAISO market conditions), synergies of up to 8% in net revenue are observed as a result of sharing the same TES, primarily due to improved revenue from enabling operation of the turbine closer to its design point, as well as being able to better take advantage of higher electricity prices. The synergy benefits are largest when the nuclear and solar plants have similar thermal output. However, when prices are less volatile the opposite behavior can be observed and it can be preferable to operate the nuclear plant as a baseload generator.

14 SOLAR ENERGY↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Perovskite (PVSK) Technology Related to Solar Cell Manufacturing Equipment (CRADA CRD-18-733 Final Report)

This CRADA between Energy Everywhere and NREL is to develop a process to fabricate flexible photovoltaic modules using a solution coated PVSK absorber with interlayers comprising materials deposited by economically feasible methods. Energy Everywhere™ will replicate and scale this process in Berkeley, California where it will ultimately commercialize the process, fabrication equipment, and PV modules.

14 SOLAR ENERGY↗

A Multi-Dimensional Benefit Assessment of Automated Mobility Platforms (AMP) for Large Facilities: Mobility, Energy, Equity, and Facility Management & Design

The goal of the automated mobility platforms (AMPs) initiative is to raise the bar of service regarding equity and sustainability for public mobility systems that are crucial to large facilities, and doing so using electrified, energy efficient technology. Using airports as an example, the rapid growth in air travel demand has led to facility expansions and congested terminals, which directly impacts equity (e.g., increased challenges for Passengers with Reduced Mobility [PRMs]) and sustainability - both of which are important metrics often overlooked during the engineering design process. Therefore, to evaluate systems and inform critical near- and long-term decisions more effectively, a holistic evaluation framework is proposed focused on four key areas: (1) mobility, with emphasis on travel time and accessibility within an airport, (2) environment, focused on energy consumption and greenhouse gas (GHG) emissions associated with intra-airport mobility, (3) equity, specifically to the PRM community, but with an eye to the whole of society, and (4) built environment, or the fundamental changes in building design enabled by different mobility systems for larger and more flexible, functional, and energy-efficient structures. Below, AMPs are defined, and each metric is discussed further, all with a focus on airport mobility.

ADVANCED PROPULSION SYSTEMS↗

Considerations for Distributed Edge Data Centers and Use of Building Loads to Support Large Interconnections

The rapid expansion of artificial intelligence (AI) and machine learning is driving unprecedented electricity demand from data centers. It is predicted that by 2030, 90% of AI workloads will be inference-based, requiring interconnection of multiple low-latency edge data centers (<20 MW) sited closer to end users - often on already constrained distribution feeders. Although individually small, these loads can aggregate to large loads per feeder, straining infrastructure, creating multi-year interconnection delays, and driving up customer costs. This paper proposes a data center-focused grid-integration framework that combines feeder hosting capacity analysis with building energy efficiency, building load flexibility, and waste heat reuse to expand effective feeder and substation headroom. Such approaches can reduce interconnection delays, lower costs for ratepayers, and accelerate AI-ready infrastructure deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating cascaded and tunable phase change materials for enhanced thermal energy storage utilization and effectiveness in building envelopes

The incorporation of phase change materials (PCMs) in envelope is considered an effective thermal energy storage (TES) method for energy savings and load flexibility in buildings. However, an important limitation of PCMs is their fixed and narrow transition temperature range. Because the interior temperature setpoints are typically different in summer versus winter, and the exterior temperature varies substantially above and below the setpoints during the year, PCMs with a fixed transition temperature are utilized only during part of the year. In this paper, we provide an extensive numerical analysis of the performance of a lightweight building envelope containing three different types of PCMs: traditional single-layer PCM with a fixed transition temperature, novel cascaded two-layer PCM with different transition temperatures, and a "futuristic" tunable PCM whose transition temperature can be varied in-situ using external excitation. We compare their performances by evaluating the relationship between the PCM utilization and parameters such as latent heat, transition temperature range, PCM thickness, and PCM location. While traditional PCMs are mostly active during one season, properly designed cascaded and tunable PCMs can be active much longer, thereby allowing load shift and energy savings in both heating and cooling seasons. Under the operating conditions considered in this study, tunable PCMs performed best, providing the highest utilization (about 2 times the traditional PCMs) and enhanced effectiveness (up to 99% peak load reduction in cooling season and 34% peak load reduction in heating season) with the same amount of material as the traditional PCMs; however, cascaded PCMs can be a good alternative while tunable PCMs are unavailable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Factor-Coupled, Ahead-of-Time Aggregation of Power Flexibility Under Forecast Uncertainty

The increasing penetration of distributed energy resources (DERs) is significantly reshaping the role of distribution systems under active energy management. To aggregate the active-reactive power flexibility of DERs dispersed at the feeder and provide capacity support to the transmission system, it is essential to efficiently identify feasible substation power injection trajectories. This paper introduces a novel ahead-of-time flexibility characterization method to address it. First, a polyhedral non-feeder-level power flexibility region (PFR) is constructed, accounting for various time-dependent, power-coupled, and forecast error uncertainties. Then, a polyhedral feeder-level PFR is analytically derived through a coordinate transformation, which can reveal the uncertainty propagation path, i.e., how uncertainty applies to the feeder-level PFR. To facilitate the high-level application, a tractable chance-constrained Chebyshev centering optimization model is further developed to find a ball-shaped inner approximation of the feeder-level PFR. Finally, the proposed method is validated on a modified IEEE 123-bus test system. Here, both theoretical and experimental results show that, with appropriate robustness parameter settings, the proposed method can make the approximated PFR less conservative with abundant robustness against forecast error uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗

A Robust Hierarchical Dispatch Scheme for Active Distribution Networks Considering Home Thermal Flexibility

Distribution networks are changing from passive absorbers of electric energy to active distribution networks (ADNs) capable of operating and participating in electricity markets. In the context of residential microgrids, which is a type of ADNs, aggregated home heating, ventilation and air-conditioning (HVAC) loads present a key opportunity to drive operational and economic objectives, facilitate high renewable energy penetration, and enhance both system resiliency and flexibility. A robust, hierarchical dispatch scheme is developed and presented in this paper, which connects an upper level multi-phase distribution optimal power flow (DOPF) to a lower level model predictive control (MPC)-based HVAC fleet controller. The approach is tested and verified on a modified IEEE 13 bus system in an intraday market application. The results demonstrate that the proposed hierarchical dispatch scheme is able to drive both economic and operational objectives for the ADN operator.

Rooks, Cody D.↗

Network-Cognizant Time-Coupled Aggregate Flexibility of Distribution Systems Under Uncertainties

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. To exploit this flexibility and to use the capacity potential of aggregate DERs, feasible substation power injection trajectories need to be efficiently characterized. This paper provides an ellipsoidal inner approximation of the set of feasible power injection trajectories at the substation such that for any point in the set, there exists a feasible disaggregation strategy of DERs for any load uncertainty realization. The problem is formulated as one of finding the robust maximum volume ellipsoid inside the flexibility region under uncertainty. Though the problem is NP-hard even in the deterministic case, this paper derives novel approximations of the resulting adaptive robust optimization problem based on optimal second-stage policies. The proposed approach yields less conservative flexibility characterization than existing flexibility region approximation formulations. The efficacy of the proposed method is demonstrated on a realistic distribution feeder.

aggregates↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Utility-Scale Storage: BESS Valuation, Tariffs, and Remuneration [Slides]

Utility-scale Battery Energy Storage Systems (BESS) are key to enhancing grid reliability, integrating renewable energy, and providing operational flexibility. Designing effective valuation, remuneration, and tariff frameworks is essential to ensure both system benefits and financial viability for developers. This presentation outlines a structured methodology for evaluating BESS projects, covering policy and legal considerations, cost and revenue analysis, benchmarking, financial sensitivity, and risk assessment, while ensuring alignment with public interest. It also explores valuation of multiple storage services - bulk energy, ancillary services, and infrastructure support - and monetization strategies through capacity payments, energy tariffs, tolling, arbitrage, and non-wires alternative payments. Technical factors, including round-trip efficiency, degradation, and storage duration, are integrated into financial and operational modeling to quantify both system-wide and project-level benefits. Through case studies and simulation-based approaches, this framework provides regulators, utilities, and developers with practical guidance for tariff design, payment structures, and investment decisions, maximizing the economic and societal value of BESS deployment.

25 ENERGY STORAGE↗

Flexible all-organic nanocomposite films interlayered with in situ synthesized covalent organic frameworks for electrostatic energy storage

Poly(vinylidene fluoride)-based terpolymers, known for having the largest dielectric constant among the existing dielectric polymers, are attractive materials for electrostatic film capacitors used in lightweight electrification systems. However, the potential of these terpolymers in film capacitor applications remains constrained by their low electrical insulating and mechanical strengths. To address these limitations, we introduced rigid covalent organic framework (COF) nanospheres into the thin films of soft terpolymers via in situ synthesis and a facile layer-by-layer solution casting method, whereby multilayer films consisting of two polymer outer layers and a COF-containing middle layer were readily obtained. The resultant all-organic thin films exhibit simultaneously high dielectric constant, enhanced breakdown strength, superior energy density (~25 J cm –3 ) at efficiencies over 80%, along with greatly improved mechanical self-supporting capability and excellent mechanical flexibility. Here, this work demonstrates the unprecedented use of COF for electrostatic energy storage, uncovering its potential for flexible electronic applications operating under high electric fields.

25 ENERGY STORAGE↗

Investigation of Stochastic Unit Commitment to Enable Advanced Flexibility Measures for High Shares of Solar PV

As the share of solar photovoltaics (PV) in the power system increases, there is a growing need for flexibility from multiple, possibly interdependent sources to adjust to PV's variability, uncertainty, and diurnal dependence. This paper investigates how stochastic unit commitment leveraging probabilistic solar forecasts can support other flexibility measures under high solar shares. We consider two flexibility measures relevant to day-ahead scheduling: battery energy time-shifting and solar ancillary service provision. Unit commitment and economic dispatch simulations are conducted on a realistic test system based on Texas using day-ahead solar trajectories. The benefits of the two flexibility measures are pronounced when the instantaneous solar share is high, offering cost savings of 10%-20% in the spring. For a Texas-sized system, this translates to hundreds of millions of dollars in cost savings once the installed PV capacity enables instantaneous solar shares regularly exceeding 40%. Using probabilistic forecasts also greatly increases the reliability of upward reserve provision from solar PV, reducing unserved reserves by 50%-100%. Both day-ahead forecast resolution and errors can impact system reliability at high solar shares, but the stochastic formulation has significant value, mitigating reliability impacts on over-forecast days.

ancillary services↗