Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

High-purity silicon crystal growth investigations

Information is given on evaporation and segregation contributions to impurity profiles of floating zone crystals (FZ); high-purity silicon float zoning (FZ); minority-carrier lifetime measurement of heavily doped silicon crystals; the effect of some crystal growth parameters on minority-carrier lifetime; and defect investigations by X-ray topography in graphical and tabular form. It was concluded that evaporation contributes substantially to impurity reduction when FZ or cold-crucible growth is conducted in a vacuum; boron and gallium may be more favorable dopants than indium or aluminum for obtaining high minority-carrier lifetimes; minority-carrier lifetimes greater than 100 microseconds are feasible at a 2 times 10 to the 17th power cm-3 doping level; minority-carrier lifetime decreases with increasing crystal cooling rate and also with the presence of dislocations; the method used to clean silicon feed rods affects lifetime; and microdefect densities in dislocation-free FZ crystals appear to be lower with Ga doping than with B doping.

Ciszek, T. F.↗

Passive Vaporizing Heat Sink

A passive vaporizing heat sink has been developed as a relatively lightweight, compact alternative to related prior heat sinks based, variously, on evaporation of sprayed liquids or on sublimation of solids. This heat sink is designed for short-term dissipation of a large amount of heat and was originally intended for use in regulating the temperature of spacecraft equipment during launch or re-entry. It could also be useful in a terrestrial setting in which there is a requirement for a lightweight, compact means of short-term cooling. This heat sink includes a hermetic package closed with a pressure-relief valve and containing an expendable and rechargeable coolant liquid (e.g., water) and a conductive carbon-fiber wick. The vapor of the liquid escapes when the temperature exceeds the boiling point corresponding to the vapor pressure determined by the setting of the pressure-relief valve. The great advantage of this heat sink over a melting-paraffin or similar phase-change heat sink of equal capacity is that by virtue of the =10x greater latent heat of vaporization, a coolant-liquid volume equal to =1/10 of the paraffin volume can suffice.

Knowles, TImothy R.↗

High-Capacity Spacesuit Evaporator Absorber Radiator (SEAR)

Future human space exploration missions will require advanced life support technology that can operate across a wide range of applications and environments. Thermal control systems for space suits and spacecraft will need to meet critical requirements for water conservation and multifunctional operation. This paper describes a Space Evaporator Absorber Radiator (SEAR) that has been designed to meet performance requirements for future life support systems. A SEAR system comprises a lithium chloride absorber radiator (LCAR) for heat rejection coupled with a space water membrane evaporator (SWME) for heat acquisition. SEAR systems provide heat pumping to minimize radiator size, thermal storage to accommodate variable environmental conditions, and water absorption to minimize use of expendables. We have built and tested a flight-like, high-capacity LCAR, demonstrated its performance in thermal vacuum tests, and explored the feasibility of an ISS demonstration test of a SEAR system. The new LCAR design provides the same cooling capability as prior LCAR prototypes while enabling over 30% more heat absorbing capacity. Studies show that it should be feasible to demonstrate SEAR operation in flight by coupling with an existing EMU on the space station.

Izenson, Michael G.↗

Shuttle/Spacelab - Platform for a cooled infrared astronomical telescope

The Shuttle IR telescope facility is planned to provide a major advance in sensitivity and observations across an IR spectrum from 1 micron to 1 mm. To accomplish this it will operate in a low earth orbit, above most of the atmosphere. The described analysis of revised designs and operations shows that the volume and weight capacity of the Shuttle is adequate for the telescope requirements. Contamination from Shuttle effluents will be significant only in the band between 20 and 30 microns, where it will degrade performance by a factor of 1.7. (The degradation will occur only with the evaporators operating.) With the addition of the telescope's fine stabilization system, the Spacelab instrument pointing and stabilization system will provide the pointing freedom and stability necessary for the telescope to reach its design goals.

Mccarthy, S. G.↗

On the Abundances of Moderately Volatile Elements in Meteorites

The abundances of the moderately volatile elements (those which condense or evaporate in the temperature range 650-1350 K) in chondritic meteorites deviate from solar (or 'cosmic', as defined by CI meteorite composition) in a manner that strongly suggests that they were determined primarily by volatility, independent of chemical affinity. Wasson and collaborators have long argued that the observed correlation of relative abundance with condensation temperature reflects a systematically selective process which favored the accretion of refractory material over volatile material from a nebula cooling from a hot initial state. This view is supported by the detailed examination of chondrules and matrix in carbonaceous meteorites and the contrast between meteorite trace element abundance patterns with those produced in heating experiments. However, the idea that the moderately volatile abundances reflect global condensation has not previously been quantitatively tested or used as a constraint on nebula evolution. We have therefore constructed models of the solar nebula designed specifically for addressing meteoritic data. Calculations so far indicate that the abundance patterns of the moderately volatile elements in chondritic meteorites can be produced naturally in an evolving nebula that cools with the reduction in opacity associated with the accumulation of meteoritic bodies. Additional information is contained in the original extended abstract.

Cassen, Pat↗

Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.

Roessler, K.↗

Film-Evaporation MEMS Tunable Array for Picosat Propulsion and Thermal Control

The Film-Evaporation MEMS Tunable Array (FEMTA) concept for propulsion and thermal control of picosats exploits microscale surface tension effect in conjunction with temperature- dependent vapor pressure to realize compact, tunable and low-power thermal valving system. The FEMTA is intended to be a self-contained propulsion unit requiring only a low-voltage DC power source to operate. The microfabricated thermal valving and very-high-integration level enables fast high-capacity cooling and high-resolution, low-power micropropulsion for picosats that is superior to existing smallsat micropropulsion and thermal management alternatives.

Propulsion↗

Prospects for Ultra-Stable Timekeeping with Sealed Vacuum Operation in Multi-Pole Linear Ion Trap Standards

A recent long-term comparison between the compensated multi-pole Linear Ion Trap Standard (LITS) and the laser-cooled primary standards via GPS carrier phase time transfer showed a deviation of less than 2.7x10(exp -17)/day. A subsequent evaluation of potential drift contributors in the LITS showed that the leading candidates are fluctuations in background gases and the neon buffer gas. The current vacuum system employs a "flow-through" turbomolecular pump and a diaphragm fore pump. Here we consider the viability of a "sealed" vacuum system pumped by a non-evaporable getter for long-term ultra-stable clock operation. Initial tests suggests that both further stability improvement and longer mean-time-between-maintenance can be achieved using this approach

timekeeping stability↗

Experimental investigation of two-phase heat transfer in a porous matrix.

One-dimensional two-phase flow transpiration cooling through porous metal is studied experimentally. The experimental data is compared with a previous one-dimensional analysis. Good agreement with calculated temperature distribution is obtained as long as the basic assumptions of the analytical model are satisfied. Deviations from the basic assumptions are caused by nonhomogeneous and oscillating flow conditions. Preliminary derivation of nondimensional parameters which characterize the stable and unstable flow conditions is given. Superheated liquid droplets observed sputtering from the heated surface indicated incomplete evaporation at heat fluxes well in access of the latent energy transport. A parameter is developed to account for the nonequilibrium thermodynamic effects. Measured and calculated pressure drops show contradicting trends which are attributed to capillary forces.

Von Reth, R.↗

Final Report

This grant was made to fund two accepted proposals to observe with the ASCA satellite: (1) Debunking the myth of two-temperature coronae of active stars, and (2) Dynamic coronae of dMe stars. We obtained the requested observations and have now completed two papers that will be published in the Astrophysical Journal. The RS CVn binary star UX Ari was observed for 14 hours with all four detectors onboard the ASCA satellite. The X-ray emission was at a constant, quiescent level during the first 12 hours, after which time a powerful flare with a peak luminosity of 1.4 x 10(exp 32) ergs/s started. The flare was observed until shortly after its peak. We present a spectral and temporal analysis of the UX Ari observations and analyze the data with a two-ribbon flare model including estimates for cooling losses. A time-dependent reconstruction of the emission measure (EM) distribution shows that two separate plasma components evolve during the flare (one being identified with the quiescent EM). Most of the flare EM reaches temperatures between 50 MK and 100 MK or more. Magnetic confinement requires the loop arcade to be geometrically large, with length scales on the order of one stellar radius. The electron densities inferred from the model decrease from initial values around 10(exp 12)/cc early in the flare to about 10(exp 11)/cc at the flare peak. The best-fit models require surface magnetic field strengths of a few hundred G, compatible with the maximum photospheric fields expected from equipartition. The flare parameters imply a (conductive and radiative) cooling loss time of less than one hour at flare peak. The elemental abundances increase significantly during the flare rise, with the abundances of the low-FIP elements Fe, Mg, Si, and Ni typically increasing to higher levels than the high-FIP elements such as S or Ne. The Fe abundance increases from (17 +/- 4)% of the solar photospheric value during quiescence up to (89 +/- 18)% at flare peak. A fractionation process that occurs during the chromospheric evaporation phase may selectively enrich low-FIP elements as in the solar corona; alternatively, the chromospheric evaporation may itself bring metal-rich plasma into the metal-poor corona.

Linsky, Jeffrey L.↗

Space-borne He-3 refrigerator

A space-compatible He-3 refrigerator is being developed for cooling the bolometric detectors of the Far Infrared Photometer (FIRP) in the Infrared Telescope in Space (IRTS). The refrigerator is self-contained and compact, and can be recycled in zero gravity with low power dissipation (20 mW or less). A laboratory prototype that contains 2 STP cu dm of He-3 has been successfully cycled upside-down, i.e., against gravity, thus proving the feasibility of the cycle in zero gravity. Sintered copper confines the He-3 to the evaporator during the low temperature phase. Temperatures as low as 280 mK have been achieved with this configuration. Other types of porous material which have lower mass density are currently under investigation.

Duband, L.↗

Interhemispheric differences in polar stratospheric HNO3, H2O, ClO, and O3

Simultaneous global measurements of nitric acid (HNO3), water (H2O), chlorine monoxide (ClO), and ozone (O3) in the stratosphere have been obtained over complete annual cycles in both hemispheres by the Microwave Limb Sounder on the Upper Atmosphere Research Satellite. A sizeable decrease in gas-phase HNO3 was evident in the lower stratospheric vortex over Antarctica by early June 1992, followed by a significant reduction in gas-phase H2O after mid-July. By mid-August, near the time of peak ClO, abundances of gas-phase HNO3 and H2O were extremely low. The concentrations of HNO3 and H2O over Antarctica remained depressed into November, well after temperatures in the lower stratosphere had risen above the evaporation threshold for polar stratospheric clouds, implying that denitrification and dehydration had occurred. No large decreases in either gas-phase HNO3 or H2O were observed in the 1992-1993 Arctic winter vortex. Although ClO was enhanced over the Arctic as it was over the Antarctic, Arctic O3 depletion was substantially smaller than that over Antarctica. A major factor currently limiting the formation of an Arctic ozone 'hole' is the lack of denitrification in the northern polar vortex, but future cooling of the lower stratosphere could lead to more intense denitrification and consequently larger losses of Arctic ozone.

Santee, M. L.↗

Multi-wavelength Observations and Modelling of a Solar Flare

Aims: The aim of this work is to investigate the dynamic behavior of a C-class solar flare through the evolution of temperature, emission measure, energy loss and velocity. In particular, the variation of these properties with time are studied using multi-wavelength observations in combination with a recently developed 0-D hydrodynamic model. Methods: The temperature and emission measure evolution were studied using several instruments covering a wide range of temperatures - the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI, >5 MK), GOES-12 (5- 30 MK), the Transition Region and Coronal Explorer (TRACE 171 A, 1 MK) and the Coronal Diagnostic Spectrometer (CDS, 0.03-8 MK). The temperature and emission measure were analysed through the systematic cooling of flare plasma through the response functions of these instruments. These parameters were then investigated using the Enthalpy Based Thermal Evolution of Loops model (EBTEL). The Doppler shifts at both flare footpoints were analysed using five emission lines seen by CDS. Results: The flare began with clear evidence for pre-flare heating. Upflows of approx.90 km/s and low level emission, both observed in Fe XIX before the main impulsive phase were explained by pre-flare gentle chromospheric evaporation. During the main impulsive phase, the flare plasma was heated to a temperature of >13 MK in approximately 10 minutes. Explosive chromospheric evaporation was observed, driving upflows of approx.80 km/s in Fe XIX and simultaneous downflows of approx.20 km/s in He I and O v. At the peak of the Rare, conduction modelled by EBTEL was found to be the dominant loss mechanism, working efficiently to both lower the temperatures and drive gentle chromospheric evaporation. As the temperature fell below approx.8 MK, radiation became the dominant loss mechanism. During the final stages of the decay phase, downflowing plasma was observed at the footpoints in He I, O v and Mg x at velocities of up to approx.40 km/s, suggesting loop draining occurred. Conclusions. This is the first extensive study of the evolution of flare plasma using both spectroscopic and broad-band instruments in conjunction with a comprehensive hydrodynamic model. The flare began with pre-flare heating and then evolved following the predictions of the standard flare model. Detailed analysis of the plasma heating mechanisms was carried out and the heating function most consistent with observations was found to be Gaussian in shape. The simulations suggested that both direct heating and heating by a non-thermal beam played significant roles in this event.

Raftery, Claire L.↗

Zero-g experiments with a He II active phase separator for space application

An active phase separator (APS) for temperature control of He II space cooling systems was tested in a zero-g environment during a series of parabolic flights on a NASA KC 135 aircraft. The APS provides for liquid-gas separation and features an annular gap, a downstream heat exchanger and an upstream ball closure. The apparatus was operated during acceleration and floating and in two different heat load situations. The tests confirmed that adequate mass flow rates could be maintained using a vacuum pump to simulate space vacuum and that residual liquid could be evaporated from the heat exchanger after closing a ball valve to seal off flows.

Denner, H. D.↗

Characterization of Flat-Plate Heat Pipe Functionality for Fuel Cell Application

For many exothermic systems such as proton exchange membrane (PEM) fuel cells, cooling is necessary to maintain consistent and uniform operating temperatures which are generally in the range of 60 to 80°C. A potential solution is a heat pipe employing the principle of conduction in combination with a phase change. The purpose of this study was to fully characterize the operation of a heat pipe with unique geometry designed for fuel cell heat removal at operating temperatures up to 100°C and to assess the suitability of the resulting performance for cooling system integration. Test variables consist of cold sink thermal contact conductance coefficient improving material usage, heat rejection temperature, contact pressure and area, heat pipe orientation, operational hours, and variability between units. The test results showed that heat pipe performance improves through increased condenser and heat sink contact pressure, thermal contact coating usage, greater condenser area utilization, and colder heat sink temperature. Higher initial heat pipe temperature and greater age or operation time reduce the heat pipe capabilities. Placing the condenser lower than the evaporator is the only heat pipe orientation that affects evaporator plate temperature. Condensing fluid in the lower section reduces heat transfer capacity as that orientation requires liquid water to transport by wicking against gravity.

Smith, Phillip J.↗

The effect of temperature cycling typical of low earth orbit satellites on thin films of YBa2Cu3O(7-x)

The refrigeration of superconductors in space poses a challenging problem. The problem could be less severe if superconducting materials would not have to be cooled when not in use. Thin films of the YBa2Cu3O(7-x) (YBCO) superconductor were subjected to thermal cycling, which was carried out to simulate a large number of eclipses of a low earth orbit satellite. Electrical measurements were performed to find the effect of the temperature cycling. Thin films of YBCO were formed by coevaporation of Y, BaF2, and Cu and postannealing in wet oxygen at 850 C for 3.5 h. The substrates used were (100) SrTiO3, polycrystalline alumina, and oxidized silicon; the last two have an evaporated zirconia layer. Processing and microstructure studies of these types of films have been published. THe zero resistance transition temperatures of the samples used in this study were 91, 82, and 86 K, respectively. The samples were characterized by four point probe electrical measurements as a function of temperature. The parameters measured were: the zero resistance transition temperature, the 10 to 90 percent transition width, and the room temperature resistance, normalized to that measured before temperature cycling. The results for two samples are presented. Each sample had a cumulative exposure. Cycling in atmospheric pressure nitrogen was performed at a rate of about 60 cycles per day, whereas in vacuum the rate was only about 10 cycles per day. The results indicate only little or no changes in the parameters measured. Degradation of superconducting thin films of YBCO has been reported due to storage in nitrogen. It is believed that the relatively good performance of films after temperature cycling is related to the fact that BaF2 was used as an evaporation source. The latest result on extended temperature cycling indicates significant degradation. Further tests of extended cycling will be carried out to provide additional data and to clarify this preliminary finding.

Mogro-Campero, A.↗

MEMS Reaction Control and Maneuvering for Picosat Beyond LEO

The MEMS Reaction Control and Maneuvering for Picosat Beyond LEO project will further develop a multi-functional small satellite technology for low-power attitude control, or orientation, of picosatellites beyond low Earth orbit (LEO). The Film-Evaporation MEMS Tunable Array (FEMTA) concept initially developed in 2013, is a thermal valving system which utilizes capillary forces in a microchannel to offset internal pressures in a bulk fluid. The local vapor pressure is increased by resistive film heating until it exceeds meniscus strength in a nozzle which induces vacuum boiling and provides a stagnation pressure equal to vapor pressure at that point which is used for propulsion. Interplanetary CubeSats can utilize FEMTA for high slew rate attitude corrections in addition to desaturating reaction wheels. The FEMTA in cooling mode can be used for thermal control during high-power communication events, which are likely to accompany the attitude correction. Current small satellite propulsion options are limited to orbit correction whereas picosatellites are lacking attitude control thrusters. The available attitude control systems are either quickly saturated reaction wheels or movable high drag surfaces with long response times.

Low-power attitude control↗

Radiative Importance of Aerosol-Cloud Interaction

Aerosol particles are input into the troposphere by biomass burning, among other sources. These aerosol palls cover large expanses of the earth's surface. Aerosols may directly scatter solar radiation back to space, thus increasing the earth's albedo and act to cool the earth's surface and atmosphere. Aerosols also contribute to the earth's energy balance indirectly. Hygroscopic aerosol act as cloud condensation nuclei (CCN) and thus affects cloud properties. In 1977, Twomey theorized that additional available CCN would create smaller but more numerous cloud droplets in a cloud with a given amount of liquid water. This in turn would increase the cloud albedo which would scatter additional radiation back to space and create a similar cooling pattern as the direct aerosol effect. Estimates of the magnitude of the aerosol indirect effect on a global scale range from 0.0 to -4.8 W/sq m. Thus the indirect effect can be of comparable magnitude and opposite in sign to the estimates of global greenhouse gas forcing Aerosol-cloud interaction is not a one-way process. Just as aerosols have an influence on clouds through the cloud microphysics, clouds have an influence on aerosols. Cloud droplets are solutions of liquid water and CCN, now dissolved. When the cloud droplet evaporates it leaves behind an aerosol particle. This new particle does not have to have the same properties as the original CCN. In fact, studies show that aerosol particles that result from cloud processing are larger in size than the original CCN. Optical properties of aerosol particles are dependent on the size of the particles. Larger particles have a smaller backscattering fraction, and thus less incoming solar radiation will be backscattered to space if the aerosol particles are larger. Therefore, we see that aerosols and clouds modify each other to influence the radiative balance of the earth. Understanding and quantifying the spatial and seasonal patterns of the aerosol indirect forcing may have even greater consequences. Presently we know that through the use of fossil fuel and land-use changes we have increased the concentration of greenhouse gases in the atmosphere. In parallel, we have seen a modest increase of global temperature in the last century. These two observations have been linked as cause and effect by climate models, but this connection is still experimentally not verified. The spatial and seasonal distribution of aerosol forcing is different from that of greenhouse gases, thus generating a different spatial fingerprint of climate change. This fingerprint was suggested as a method to identify the response of the climate system to anthropogenic forcing of greenhouse gases and aerosol. The aerosol fingerprint may be the only way to firmly establish the presence (or absence) of human impact on climate. Aerosol-cloud interaction through the indirect effect will be an important component of establishing this fingerprint.

Tsay, Si-Chee↗