Search NASA⌕ Search

SEARCH · Search NASA

Results for “exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Magnetization dynamics with time-dependent spin-density functional theory: Significance of exchange-correlation torques

In spin-density functional theory (SDFT) for noncollinear magnetic materials, the Kohn-Sham system features exchange-correlation (xc) scalar potentials and magnetic fields. The significance of the xc magnetic fields is not very well explored; in particular, they can give rise to local torques on the magnetization, which are absent in standard local and semilocal approximations. Here, exact benchmark solutions for a five-site extended Hubbard lattice at half filling and in the presence of spin-orbit coupling are compared with SDFT results obtained using orbital-dependent exchange-only approximations. The magnetization dynamics following short-pulse excitations is found to be reasonably well described in the exchange-only approximation for weak to moderate interactions. For stronger interactions and near transitions between magnetically ordered and frustrated phases, exchange and correlation torques tend to compensate each other and must both be accounted for.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of random antiferromagnetic exchange on the spin waves in a three-dimensional Heisenberg ferromagnet

Neutron scattering is used to study spin waves in the three-dimensional Heisenberg ferromagnet YTiO 3 , with spin-spin exchange disorder introduced via La substitution at the Y site. No significant changes are observed in the spin-wave dispersion up to a La concentration of 20%. However, a strong broadening of the spectrum is found, indicative of shortened spin-wave lifetimes. Density-functional theory calculations predict minimal changes in exchange constants as a result of average structural changes due to La substitution, in agreement with the data. The absence of significant changes in the spin-wave dispersion, the considerable lifetime effect, and the reduced ordered magnetic moment previously observed in the La-substituted system are qualitatively captured by an isotropic, nearest-neighbor, three-dimensional Furthermore, Heisenberg ferromagnet model with random antiferromagnetic exchange. We therefore establish Y 1-$x$ La $x$ TiO 3 as a model system for the study of antiferromagnetic spin-exchange disorder in a three-dimensional Heisenberg ferromagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Helium-4 gravitational form factors: Exchange currents

We evaluate the leading exchange corrections to the helium-4 gravitational form factors (GFFs) to momenta of the order of the nucleon mass. We use both the K-harmonic method with simple pair nucleon potential, and a Jastrow trial function using the Argonne 𝑣 14 potential, to evaluate the helium-4 GFFs. The exchange current contributions include the pair interaction, plus the seagull and the pion exchange interactions, modulo the recoil corrections. To estimate the off-shellness of the pion nucleon coupling in this momenta range, we discuss the results using either the pseudoscalar (PS) or pseudovector (PV) pion-nucleon couplings. When the PV coupling is used, the pair diagram contribution is higher order in the nonrelativistic expansion. The results for the helium-4 A-GFF are comparable to those given by the impulse approximation, especially for the PS coupling using both the K-harmonic method and variational method. The exchange current contributions with the PS coupling for the charge form factor of helium-4, yield better agreement with the existing data over a broad range of momenta, especially when the Argonne 𝑣 14 potential including the D-wave admixture is used.

A ≤ 5↗

Revisiting gauge invariance and Reggeization of pion exchange

The Reggeized pion is expected to provide the main contribution to the forward cross section in light meson photoproduction reactions with charge exchange at high energies. We discuss the Reggeization of pion exchange in charged pion photoproduction with an emphasis on consistency with current conservation. We show that the gauge-invariant amplitude for the exchange of a particle with a generic even spin J ≥ 2 in the t channel is analytic at J = 0 and that it can be interpreted in terms of the nucleon electric current. This enables us to reconcile the dynamics in the s and u channel, which involves also nucleon exchanges, with the amplitude expressed in terms of t -channel partial waves, as required by Regge theory. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗

Air-to-Liquid Heat Exchanger Fabricated Using Deposition-Based Additive Manufacturing Processes

Abstract This work describes the use of deposition-based additive manufacturing (AM) techniques to fabricate air-cooled, two-fluid heat exchangers. The project focused on a Heating, Ventilation and Air Conditioning application and used an industry-standard copper/aluminum heat exchanger manufactured with conventional technology as the basis for assessing performance. The manufacturing constraints associated with using deposition-based AM technology for this application include the need for a continuous tool path within each build layer that allows uninterrupted extrusion and therefore defect-free water channel walls that correspond to a reliably leak-tight heat exchanger. A geometry that respects these constraints was developed, simulated, optimized and finally manufactured and tested. The material used was a composite of polymer filled with conductive flakes in order to provide high conductivity in the direction that heat must flow in this heat exchanger, across the wall separating the fluids. The measured performance for several test coupons matched the predicted performance and the test coupons exhibited performance that approach and in some cases exceeds conventional technology

Engineering↗

Influence of Supporting Electrolyte on Hydroxide Exchange Membrane Water Electrolysis Performance: Anolyte

Hydroxide-exchange-membrane water electrolysis (HEMWE) is an emerging hydrogen-production pathway that combines many advantages of incumbent alkaline water electrolysis (AWE) and proton-exchange-membrane water electrolysis (PEMWE). Advancement in HEMWE has been accelerated with the development of stable and conductive hydroxide exchange membranes (HEMs) and a more comprehensive understanding of alkaline gas-evolving kinetics. However, performance and durability without supporting electrolytes (SELs) remain inferior to PEMWE and AWE and little is known about the role and impact of the SELs. This study investigates the effects of SELs used as anolyte solutions in HEMWEs including cation-type, anion-type, SEL conductivity and pH, presence of carbonates and increased cation/OH- ratios on cell voltage and stability. We report our findings that (i) cell potential and high-frequency resistance did not correlate with anolyte SEL conductivity, (ii) cation-type influences cell voltage at low current densities (<50 mA cm -2 ) as predicted by half-cell measurements, (iii) increased cation/OH- ratio causes increased overpotentials, and (iv) carbonates are exchanged in the HEM but removed via self-purging at high current density. Overall, this study concludes that concentrated KOH is still the best SEL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyporheic hydraulic geometry: Conceptualizing relationships among hyporheic exchange, storage, and water age

Hyporheic exchange is now widely acknowledged as a key driver of ecosystem processes in many streams. Yet stream ecologists have been slow to adopt nuanced hydrologic frameworks developed and applied by engineers and hydrologists to describe the relationship between water storage, water age, and water balance in finite hydrosystems such as hyporheic zones. Here, in the context of hyporheic hydrology, we summarize a well-established mathematical framework useful for describing hyporheic hydrology, while also applying the framework heuristically to visualize the relationships between water age, rates of hyporheic exchange, and water volume within hyporheic zones. Building on this heuristic application, we discuss how improved accuracy in the conceptualization of hyporheic exchange can yield a deeper understanding of the role of the hyporheic zone in stream ecosystems. Although the equations presented here have been well-described for decades, our aim is to make the mathematical basis as accessible as possible and to encourage broader understanding among aquatic ecologists of the implications of tailed age distributions commonly observed in water discharged from and stored within hyporheic zones. Our quantitative description of “hyporheic hydraulic geometry,” associated visualizations, and discussion offer a nuanced and realistic understanding of hyporheic hydrology to aid in considering hyporheic exchange in the context of river and stream ecosystem science and management.

54 ENVIRONMENTAL SCIENCES↗

Crystal structure of an RNA/DNA strand exchange junction

Short segments of RNA displace one strand of a DNA duplex during diverse processes including transcription and CRISPR-mediated immunity and genome editing. These strand exchange events involve the intersection of two geometrically distinct helix types—an RNA:DNA hybrid (A-form) and a DNA:DNA homoduplex (B-form). Although previous evidence suggests that these two helices can stack on each other, it is unknown what local geometric adjustments could enable A-on-B stacking. Here we report the X-ray crystal structure of an RNA-5′/DNA-3′ strand exchange junction at an anisotropic resolution of 1.6 to 2.2 Å. The structure reveals that the A-to-B helical transition involves a combination of helical axis misalignment, helical axis tilting and compression of the DNA strand within the RNA:DNA helix, where nucleotides exhibit a mixture of A- and B-form geometry. These structural principles explain previous observations of conformational stability in RNA/DNA exchange junctions, enabling a nucleic acid architecture that is repeatedly populated during biological strand exchange events.

59 BASIC BIOLOGICAL SCIENCES↗

Leaf gas exchange raw data, 2015 - 2017, at Manaus, Brazil

This data package contains raw leaf gas exchange data from the NGEE Tropics K34 tower site on a plateau near Manaus, Brazil. Data was collected using sensor and leaf sample measurements. Leaves on a target tree were chosen by accessing a branch near the tower. In some cases, the branch was naturally positioned near the tower and in other cases, a small rope was used to pull the branch closer to the tower for better access to leaves. Mature leaves were targeted in nearly all cases. The gas exchange system was hauled with a climbing rope to the level of the branch on the tower and the sensor head/leaf enclosure was installed near the branch of interest using a magic arm. We measured leaf gas exchange from 5:00 AM to 5:00 PM, randomly cycling through the approximately 20 leaves in the targeted branch(es). Data were collected over two time periods, detailed within the files. The attached data files contain raw data, sensor manuals, and PDFs with detailed methods and procedures separated into multiple folders. Data is in Excel file format. See data references for data package containing related metadata. This dataset replaces the leaf gas exchange data of two retired packages, NGT0019 and NGT0040.

54 ENVIRONMENTAL SCIENCES↗

STRESS AND FATIGUE ANALYSIS OF AIR-TO-REFRIGERANT HEAT EXCHANGERS WITH NON-ROUND TUBE SHAPES

Air-to-refrigerant heat exchangers are fundamental components in Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems. Recent research has shown that heat exchangers utilizing small hydraulic diameter, non-round, shape-optimized tubes to be promising next design update. Such tubes can improve performance, reduce material and lower refrigerant charge. However, such tube designs may be more susceptible to fatigue issues. Therefore, stress and fatigue analyses of such heat exchangers are critical to ensure structural integrity, reliability, and manufacturability. In the present work, a mechanical model is developed to obtain the stress distributions in heat exchangers with round, ellipse, and airfoil-shaped tubes. The results indicate that under 3.45 MPa internal pressure, the maximum stresses don't surpass 190 MPa.

Zhang, Mingkan↗

Compact Diffusion Bonded Heat Exchanger Fatigue Life Simulations (Final Report)

Compact diffusion bonded heat exchangers are essential for high pressure heat exchange, but they are subject to thermal fatigue and ramp rate limitations. Simulation of these geometries is challenging with a large range of length and time scales from thousands of mm-sized microchannels inside a m-sized heat exchanger. Multi-physics simulations including thermal, fluid, and solid mechanics components are being used to predict stress within the heat exchangers under these conditions. These predictions can then be used to understand thermal ramp rate limitations while keeping maximum stresses low as well as fatigue life predictions from well-known empirical models.

42 ENGINEERING↗

Optimal Header Design for Diffusion Bonded Heat Exchangers

Microchannel heat exchangers have seen increasing adoption in many high-pressure applications in recent decades but are subject to particulate fouling from the relatively small channel size compared to traditional designs. Typical cleaning methods require process shutdown, heat exchanger removal, cleaning, then reassembly. The objective of this project was to refine and transfer technology to enable header design improvements for Cleaning-in-Place (CIP), allowing for reduced/negligible process interruption for the cleaning process. The technology transfer was from Sandia National Laboratories (Sandia) to Vacuum Process Engineering, Inc. (VPE). This primary purpose of CIP was developed while considering channel flow uniformity and heat exchanger cost. The project phases were to 1) capture and define potential improvement options, 2) evaluate options with both simulation and experiments, and 3) transfer design knowledge to the industry partner. These efforts resulted in improved header designs from the first known focused effort in this area. The improved designs will help the entire microchannel heat exchanger field that has applications in supercritical CO 2 power cycles, hydrogen (fuel cell) vehicle fueling, liquified natural gas processing, and more.

42 ENGINEERING↗

Universal Utility Data Exchange (UUDEX) Functional Design Requirements - Rev 1

This document provides a set of high-level functional design requirements for Universal Utility Data Exchange (UUDEX). These requirements include a set of use cases, data exchanges supported by UUDEX, both for grid operations and for cyber security data, functional requirements for data exchange, data models used by UUDEX, data exchange architectures, and security considerations. These functional design requirements are intended to be used in more detailed design documents.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of a Prototype Moving Packed-Bed Particle/sCO 2 Heat Exchanger

Particle heat exchangers are a critical enabling technology for next generation concentrating solar power (CSP) plants that use supercritical carbon dioxide (sCO 2 ) as a working fluid. This report covers the design, manufacturing and testing of a prototype particle-to-sCO 2 heat exchanger targeting thermal performance levels required to meet commercial scale cost targets. In addition, the the design and assembly of integrated particle and sCO 2 flow loops for heat exchanger performance testing are detailed. The prototype heat exchanger was tested to particle inlet temperatures of 500 °C at 17 MPa which resulted in overall heat transfer coefficients of approximately 300 W/m 2 -K at the design point and cases using high approach temperature with peak values as high as 400 W/m 2 -K

14 SOLAR ENERGY↗

Computational Fluid Dynamics and Heat Transfer Modeling of a Dimpled Heat Exchanger

Multiphysics and analytical calculations were conducted for a heat exchanger with passive, natural circulation flow. A glycol/water working fluid convects the heat to a dimpled heat exchanger shell, which subsequently transfers the heat to the soil, which acts as the ultimate heat sink. Because the system is fully-passive, it is not subject to the expenses, maintenance, and mechanical breakdowns associated with moving parts. Density, heat capacity, and thermal conductivity material properties were measured for various soil samples, and subsequently included as input for the soil heat conduction model. The soil model was coupled to a computational fluid dynamics (CFD) heat exchanger model that included the dynamic Smagorinsky large eddy simulation and k- omega turbulence models. The analysis showed that the fluid dynamics and heat transfer models worked properly, albeit at a slow pace. Nevertheless, the coupled CFD/heat conduction simulation ran long enough to determine a key parameter—the amount of heat conducted from the heat exchanger to the ground. This unique performance value, along with experimental data, was used as input for stand-alone, fast-running CFD models, as well as boundaries to obtain solutions to partial differential equations for soil heat conduction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

A framework of stress analysis and fatigue analysis was developed. Utilizing the framework, stress analysis and fatigue analysis of high-performance heat exchangers with non-round shaped tubes were studied. The tubes, headers and welding layers were studied separately before analyzing the assembled heat exchangers. Results reveal different stress strength on the different shapes of tubes and headers. Unevenly welding distribution is also discussed in the report. Moreover, the fatigue analysis results of the heat exchanger are helping to estimate the lifetime of the heat exchanger from fatigue point of view.

42 ENGINEERING↗

Adaptive Determination of the Optimal Exchange Location in Wall-Modeled Large-Eddy Simulation

Wall-modeled large-eddy simulation introduces a modeling interface (or exchange location) separating the wall-modeled layer from the rest of the domain. The current state-of-the-art is to rely on user expertise when choosing where to place this modeling interface, whether this choice is tied to the grid or not. This paper presents a postprocessing algorithm that determines the exchange location systematically. The algorithm is based on a model for the error in the predicted wall shear stress and a model for the computational cost, and then finds the exchange location that minimizes a combination of the two. Here, the algorithm is tested both a priori and a posteriori using an equilibrium wall model for the flow over a wall-mounted hump, a boundary layer in an adverse pressure gradient, and a shock/boundary-layer interaction. The algorithm produces exchange locations that mostly agree with what an experienced user would suggest, with thinner wall-modeled layers in nonequilibrium flow regions and thicker wall-modeled layers where the boundary layer is closer to equilibrium. This suggests that the algorithm should be useful in simulations of realistic and highly complex geometries.

42 ENGINEERING↗