Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The damping of ocean surface waves by a monomolecular film measured by wave staffs and microwave radars

Open ocean and wave tank experiments were carried out with the aim of studying the damping of capillary and gravity waves by a monomolecular film. These films of biogenic origin influence air-sea interaction processes and thereby affect the use of remote sensing techniques in oceanography. Measurement was carried out by wave staffs, by a coherent X band microwave scatterometer mounted on a sea-based platform, and by an incoherent K band microwave scatterometer carried by an aircraft under moderate wind conditions. A wave attenuation of about 40-60% is observed in the frequency range between 3.2 and 16 Hz. Tank experiments show that a direct influence of oleyl alcohol surface films on wave damping is confined to frequencies equal to or greater than 2 Hz; a further indirect effect of films on the damping of ocean waves in the frequency range between 0.12 and 0.7 Hz (by modifying the wind input and wave-wave interaction mechanisms) is also indicated

Huehnerfuss, H.↗

Transition from Townsend to radio-frequency homogeneous dielectric barrier discharge in a roll-to-roll configuration

The aim of this paper is to better understand the transition from Townsend to radio-frequency homogeneous dielectric barrier discharge (DBD) at atmospheric pressure. The study is done in an Ar/NH{sub 3} Penning mixture for an electrode configuration adapted to roll-to-roll plasma surface treatment. The study was led in a frequency range running from 50 kHz up to 8.3 MHz leading to different DBD modes with a 1 mm gas gap: Glow (GDBD), Townsend (TDBD), and Radio-frequency (RF-DBD). In the frequency range between TDBD and RF-DBD, from 250 kHz to 2.3 MHz, additional discharges are observed outside the inter-electrode gas gap. Because each high voltage electrode are inside a dielectric barrel, these additional discharges occur on the side of the barrel where the gap is larger. They disappear when the RF-DBD mode is attained in the 1 mm inter-electrode gas gap, i.e., for frequencies equal or higher than 3 MHz. Fast imaging and optical emission spectroscopy show that the additional discharges are radio-frequency DBDs while the inter-electrode discharge is a TDBD. The RF-DBD discharge mode is attained when electrons drift becomes low enough compared to the voltage oscillation frequency to limit electron loss at the anode. To check that the additional discharges are due to a larger gas gap and a lower voltage amplitude, the TDBD/RF-DBD transition is investigated as a function of the gas gap and the applied voltage frequency and amplitude. Results show that the increase in the frequency at constant gas gap or in the gas gap at constant frequency allows to obtain RF-DBD instead of TDBD. At low frequency and large gap, the increase in the applied voltage allows RF-DBD/TDBD transition. As a consequence, an electrode configuration allowing different gap values is a solution to successively have different discharge modes with the same applied voltage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical study of the spectrum of broadband electrostatic noise in the magnetotail

A numerical study of the spectrum of broadband electrostatic noise (BEN) generated by ion beams in the plasma sheet boundary layer (PSBL) is presented, in which two cases are analyzed. The first case is concerned with a single hot-electron species. In the second case, a second population of cold electrons (arising from diffusion from the lobe into the PSBL) is introduced. The presence of the second electron component in the dispersion relation for generating BEN was found to significantly increase the upper frequency range of the unstable spectrum, enhancing the associated growth rates. It is shown that ion beam instabilities can explain most major features of the observed BEN spectrum. The results explain the gradual rise in the upper frequency range of BEN as a spacecraft approaches the plasma sheet from the lobe, and the sudden jump in that frequency up to near the plasma frequency upon crossing the PSBL.

Grabbe, Crockett L.↗

The Polar Plasma Wave Instrument

The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

Gurnett, D. A.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Dielectric property of NiTiO{sub 3} doped substituted ortho-chloropolyaniline composites

Ortho-chloropolyaniline (OCP)-NiTiO{sub 3} composites have been synthesized via in-situ polymerization of ortho-chloroaniline with various weight percentages of NiTiO{sub 3.} Fourier Transform Infrared spectroscopic studies of Ortho-chloropolyaniline and its composites indicated the formation of composites as a result of Vander Waal's interaction between OCP and NiTiO{sub 3} particles. Surface morphology of OCP and OCP-NiTiO{sub 3} composites were studied using Scanning Electron Microscope (SEM). The SEM micrographs indicated a modified morphology after the composite formation. Dielectric properties and electric modulus of OCP and OCP-NiTiO{sub 3} composites have been investigated in the frequency range of 50 Hz – 5 MHz. It has been noticed that electrical resistance decreases with increase in weight percentage of NiTiO{sub 3} particles in polymer matrix as well as with applied frequency. The display of semicircular arcs in Cole-Cole plots indicates the formation of series resistor and capacitor in network causing a decrease in the relaxation time and as a result conductivity enhances in these composites. The facile and cost effective synthesis process and excellent dielectric and conductivity response of these materials makes them promising materials for practical applications.

36 MATERIALS SCIENCE↗

Ferroelectric and dielectric study of strontium tantalum based perovskite oxynitride films deposited by reactive rf magnetron sputtering

Highlights: • Oxynitride perovskite thin films were deposited by reactive sputtering. • Films are textured or epitaxially grown on MgO and Nb-SrTiO{sub 3} substrates. • Local piezoelectric and ferroelectric behavior was highlighted by PFM. • A 1600 nm-thick film presents a permittivity of 175 at 10 kHz and RT. • Permittivity is around 65 in high frequency range. - Abstract: Strontium and tantalum based oxynitride perovskite thin films were deposited by reactive magnetron sputtering. Epitaxial films deposited on Nb-SrTiO{sub 3} substrates show smooth surfaces with roughness values from 1.5 to 3.6 nm for a thickness of films in the range 20–1600 nm. The samples are yellow with band gap values around 2.35 eV. Piezo-force microscopy characterization pointed out the local piezoelectric and ferroelectric behavior of the oxynitride perovskite films. In the low frequency range, the 1600 nm-thick film exhibits a permittivity of 175 at 10 kHz, with dielectric losses of 0.055. Permittivity is lowered in high frequencies with a value around 65 obtained on a 1520 nm-thick film deposited on MgO substrate, which is textured with a preferential c-axis orientation. No accordability of the permittivity was highlighted at a macroscopic scale. The moderate crystallographic strain evidenced in the 20 nm thin film does not induce a high permittivity.

36 MATERIALS SCIENCE↗

Automated design of an additive manufactured compact broadband antenna for plasma reflectometry

Broadband antennas operating in the gigahertz frequency range are regularly used for plasma reflectometry diagnostics. Due to a lack of space and unique diagnostic constraints, these antennas are often custom in design and frequency range. Recent advances in additive manufacturing of high temperature copper alloys allow for expanded freedom in design of these diagnostic antennas. In this work, a heuristic simulated annealing algorithm is used alongside 3-D finite element simulation to automate the design of a double ridged rectangular horn antenna for a reflectometry diagnostic on the DIII-D tokamak. Optimization of antenna performance given the design constraints results in a compact broadband (6-20+ GHz) antenna design. Measured transmission from the additively manufactured antenna matches simulation within reasonable error, and experimental plasma electron density profiles from the DIII-D high-field side scrape-off layer are shown.

Additive manufacturing↗

Optimizing biased semiconductor superlattices for terahertz amplification

Over the past 15 yr or more, researchers have been trying to achieve gain for electromagnetic fields in the terahertz frequency region using biased semiconductor superlattices, but with little success. In this work, we employ our model of the excitonic states in biased GaAs/Al{sub 0.3}Ga{sub 0.7}As semiconductor superlattices to find the optimal structures for amplification of terahertz radiation. In particular, we determine the optimum well width, barrier width, and bias field for terahertz fields with frequencies ranging from 1 to 4 terahertz. We find that gain coefficients on the order of 40 cm{sup −1} should be achievable over most of this frequency range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical properties of MHD fluctuations associated with high speed streams from HELIOS 2 observations

Helios 2 magnetic data were used to obtain several statistical properties of MHD fluctuations associated with the trailing edge of a given stream served in different solar rotations. Eigenvalues and eigenvectors of the variance matrix, total power and degree of compressibility of the fluctuations were derived and discussed both as a function of distance from the Sun and as a function of the frequency range included in the sample. The results obtained add new information to the picture of MHD turbulence in the solar wind. In particular, a dependence from frequency range of the radial gradients of various statistical quantities is obtained.

Bavassano, B.↗

Sound Transmission through Two Concentric Cylindrical Sandwich Shells

This paper solves the problem of sound transmission through a system of two infinite concentric cylindrical sandwich shells. The shells are surrounded by external and internal fluid media and there is fluid (air) in the annular space between them. An oblique plane sound wave is incident upon the surface of the outer shell. A uniform flow is moving with a constant velocity in the external fluid medium. Classical thin shell theory is applied to the inner shell and first-order shear deformation theory is applied to the outer shell. A closed form for transmission loss is derived based on modal analysis. Investigations have been made for the impedance of both shells and the transmission loss through the shells from the exterior into the interior. Results are compared for double sandwich shells and single sandwich shells. This study shows that: (1) the impedance of the inner shell is much smaller than that of the outer shell so that the transmission loss is almost the same in both the annular space and the interior cavity of the shells; (2) the two concentric sandwich shells can produce an appreciable increase of transmission loss over single sandwich shells especially in the high frequency range; and (3) design guidelines may be derived with respect to the noise reduction requirement and the pressure in the annular space at a mid-frequency range.

Tang, Yvette Y.↗

Determining diffusion coefficients of ionic liquids by means of field cycling nuclear magnetic resonance relaxometry

Field Cycling Nuclear Magnetic Resonance (FC NMR) relaxation studies are reported for three ionic liquids: 1-ethyl-3- methylimidazolium thiocyanate (EMIM-SCN, 220–258 K), 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM-BF{sub 4}, 243–318 K), and 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF{sub 6}, 258–323 K). The dispersion of {sup 1}H spin-lattice relaxation rate R{sub 1}(ω) is measured in the frequency range of 10 kHz–20 MHz, and the studies are complemented by {sup 19}F spin-lattice relaxation measurements on BMIM-PF{sub 6} in the corresponding frequency range. From the {sup 1}H relaxation results self-diffusion coefficients for the cation in EMIM-SCN, BMIM-BF{sub 4}, and BMIM-PF{sub 6} are determined. This is done by performing an analysis considering all relevant intra- and intermolecular relaxation contributions to the {sup 1}H spin-lattice relaxation as well as by benefiting from the universal low-frequency dispersion law characteristic of Fickian diffusion which yields, at low frequencies, a linear dependence of R{sub 1} on square root of frequency. From the {sup 19}F relaxation both anion and cation diffusion coefficients are determined for BMIM-PF{sub 6}. The diffusion coefficients obtained from FC NMR relaxometry are in good agreement with results reported from pulsed- field-gradient NMR. This shows that NMR relaxometry can be considered as an alternative route of determining diffusion coefficients of both cations and anions in ionic liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anti-Phase Vortex Reduction Control for Rotor Noise Suppression

An investigation is conducted in 2019 under the NASA Ames Center Innovation Funds (CIF) project entitled “Anti-Phase Vortex Reduction Control for Rotor Noise Suppression“ to experimentally validate an anti-phase rotor noise suppression concept. The first objective of the investigation is to conduct computational fluid dynamics (CFD) simulations to investigate the noise characteristics of several anti-phase rotor designs. The second objective is to conduct a series of acoustic tests of anti-phase rotors in an anechoic chamber at Pennsylvania State University (PSU) to evaluate the merit of the anti-phase rotor concept. The CFD investigation seeks to optimize the anti-phase alternating trailing edge patterns for rotor noise suppression. The design objective is to maximize the noise reduction while maintaining the aerodynamic thrust. The investigation is performed using a three-dimensional (3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) commercial solver STAR-CCM+ together with the Ffowcs-Williams and Hawkings (FW-H) formula to obtain the aerodynamic thrust and far-field noise level. An acoustic study is conducted for 13 anti-phase design candidates based on a proprietary rotor design. The CAD geometry of the rotor is furnished by PSU. These design candidates include different alternating trailing edge (TE) waveforms, TE segment lengths, TE deflection amplitudes, and transition characteristics. The best design candidate among those explored is an anti-phase rotor that has a four-period TE waveform which results in a reduction in far-field noise level of 2.1 dB in the hover condition and a reduction of 1.1 dB in the forward flight condition at 9.7 m/s. A further acoustic study is conducted for a different rotor manufactured by APC. Five APC rotor design candidates are simulated. The best anti-phase design candidate for the APC rotor results in a reduction in far-field noise level of 4.0 dB in the hover condition. An in-phase design candidate is also studied. This in-phase design provides a noise reduction of 2.5 dB. A series of acoustic experiments in the PSU anechoic chamber have been conducted in July 2019 and October 2019. Both anti-phase and in-phase rotors fabricated for the left-hand and right-hand rotations are tested. In the hover condition, all the rotors do not provide sufficient evidence of improved acoustic performance. However, the experimental data in the hover condition are deemed to be inconclusive due to the flow recirculation in the anechoic chamber caused by the rotor downwash. In the forward flight condition at 9.7 m/s, the anti-phase right-hand rotor produces a noise reduction by as much as 6.5 dB in the frequency range of 2000-4000 Hz, while the in-phase right-hand rotor produces a noise reduction by as much as 5 dB in the same frequency range. Both the anti-phase and in-phase left hand rotors offer no evidence of noise reduction. The difference in the acoustic performance of the left-hand and right-hand rotors could be explained by the location of the microphone array which is placed to the left side of the rotors. This microphone array location could create a bias in the sound pressure level in favor of the right-hand rotor. Using the average noise reduction values, the anti-phase 4H rotor could offer a noise reduction by as much as 3.25 dB while the in-phase 4I rotor could produce up to a 2.5 dB noise reduction. Both the computational and experimental results have provided sufficient evidence to support the noise suppression capability of the proposed anti-phase rotor concepts.

Rotor noise↗

Radar Attenuation by Sand: Laboratory Measurement of Radar Transmission

Under certain conditions, radar is able to penetrate loose sand to reveal subsurface geology in arid areas. However, backscatter from the subsurface is modified by signal attenuation by the sand, To quantify the amount of radar transmission as a function of radar frequency and sand moisture. The frequency range covers P-through X-bands (0.5 - 12.6 GHz), and the moisture contents of the sand were 0.3, 4.7, and 10.7% by volume. Results show that addition of the sand causes a small decrease in transmission at low frequencies for all three moisture levels, but the sand causes a large decrease in transmission at higher frequencies. The transmission measurements were also used to calculate values for attenuation, The dry sand resulted in attenuations of less than 6 dB/m over the entire frequency range. Sand with moisture contents of 4.7 and 10.7% volume caused by attenuations greater than 150 dB/m at the highest frequencies, but the attenuation values calculated for P-and L-band frequencies were less than 10 dB/m even at these relatively high moisture levels. THese results challenge previous restrictions that sand must be extremely dry for radar penetration to occur.

Williams, Kevin K.↗

Magnetic and Electrical Characteristics of Cobalt-Based Amorphous Materials and Comparison to a Permalloy Type Polycrystalline Material

Magnetic component designers are always looking for improved soft magnetic core materials to increase the efficiency, temperature rating and power density of transformers, motors, generators and alternators, and energy density of inductors. In this paper, we report on the experimental investigation of commercially available cobalt-based amorphous alloys which, in their processing, were subjected to two different types of magnetic field anneals: A longitudinal magnetic field anneal or a transverse magnetic field anneal. The longitudinal field annealed material investigated was Metglas 2714A. The electrical and magnetic characteristics of this material were investigated over the frequency range of 1 to 200 kHz and temperature range of 23 to 150 C for both sine and square wave voltage excitation. The specific core loss was lower for the square than the sine wave voltage excitation for the same maximum flux density, frequency and temperature. The transverse magnetic field annealed core materials include Metglas 2714AF and Vacuumschmelze 6025F. These two materials were experimentally characterized over the frequency range of 10 to 200 kHz for sine wave voltage excitation and 23 C only. A comparison of the 2174A to 2714AF found that 2714AF always had lower specific core loss than 2714A for any given magnetic flux density and frequency and the ratio of specific core loss of 2714A to 2714AF was dependent on both magnetic flux density and frequency. A comparison was also made of the 2714A, 2714AF, and 6025F materials to two different tape thicknesses of the polycrystalline Supermalloy material and the results show that 2714AF and 6025F have the lowest specific core loss at 100 kHz over the magnetic flux density range of 0.1 to 0.4 Tesla.

Wieserman, William R.↗

Tracking Seismic Velocity Perturbations at Ridgecrest Using Ballistic Correlation Functions

Abstract We present results based on data of a dense nodal array composed of 147 stations, deployed in 2022 near the epicenter of the 2019 Mw 7.1 Ridgecrest earthquake to investigate characteristics of the seismic wavefields. Through array analyses, we identified two primary components. First, we observed far-field P waves dominating the 0.5–1.2 Hz frequency range, which are likely primarily generated by wind-driven oceanic swell activity. Second, we detected near-field body waves resulting from anthropogenic activities in the frequency range 2–8 Hz. We examined noise correlation functions derived from data of the dense deployment and regional stations to explore fault-zone seismic velocity changes using ballistic arrivals, with a focus on velocity perturbation shortly before and after the Ridgecrest earthquake sequence. Our findings exhibit distinct behavior compared to results obtained through standard coda-wave interferometry. Particularly, we observed a decrease in P-wave travel time on certain station pairs prior to the 2019 earthquake sequence. Supported by detailed investigation of the local seismic wavefields, we interpret the decreasing P-wave travel time as likely caused by a velocity increase away from the fault, possibly related to fluid migration. However, additional information is necessary to verify this hypothesis.

Geochemistry & Geophysics↗

A new ion and electron detector for ion cyclotron resonance spectroscopy.

A new detector using an extremelly driven tuned circuit has been developed for use in ion cyclotron resonance spectroscopy experiments. Based on the Q-meter circuit, this detector will operate at frequencies greater than 1 MHz at rf levels less than 1 mV. Operation in the frequency range 1-15 MHz allows the use of higher magnetic fields for more efficient storage of low mass ions in the trapping mode of operation. In the frequency range 2-6 MHz electrons can be detected in the ion cyclotron resonance cell by their resonant motion in the trapping plane.

Huntress, W. T., Jr.↗