Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Methods, systems, and computer readable media for protecting and controlling a microgrid with a dynamic boundary

Methods, systems, and computer readable mediums for protecting and controlling a microgrid with a dynamic boundary are disclosed. One method includes detecting a fault in a microgrid that includes a dynamic point-of-common-coupling (PCC), in response to determining that the microgrid is operating in a grid-connected mode, isolating the fault by tripping a microgrid side smart switch and a grid side smart switch that are located immediately adjacent to the fault, initiating the reclosing of the grid side smart switch, and initiating the reclosing for the microgrid side smart switch via resynchronization if the grid side smart switch is successfully reclosed, and in response to determining that the microgrid is operating in an islanded mode, isolating the fault by tripping a microgrid side smart switch that is located immediately adjacent to the fault, and initiating the reclosing of the microgrid side smart switch.

Wang, Fei↗

Improved Control Strategy of Grid Interface for EV High-Power Dynamic Wireless Charging

This paper proposes a control strategy for the grid interface converter in high-power dynamic wireless charging system (DWCS) to address two issues on distribution network integration. Due to the unique pulsating load profile of DWCS, load transient response capability is critical for the grid interface to maintain the dc-bus voltage stable. Besides, the inherent unbalanced situation of distribution network would lead to 2nd-order oscillations on the dc-bus voltage, which would further affect the stable operation of the entire system. In this paper, the DWCS model is developed, and the relationship between the dc-bus voltage and the input/output power is analyzed. Based on the developed model, a control strategy based on direct power control is presented. Both simulation results and hardware-in-the-loop (HIL) results demonstrate that the proposed control strategy not only improves load transient response capability, but also eliminates the 2nd-order oscillations on the dc-bus voltage under imbalanced distribution network conditions.

Zeng, Rong↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Feedback-Based Projected-Gradient Method for Real-Time Optimization of Aggregations of Energy Resources

This paper develops an online optimization method to maximize operational objectives of distribution-level distributed energy resources (DERs), while adjusting the aggregate power generated (or consumed) in response to services requested by grid operators. The design of the online algorithm is based on a projected-gradient method, suitably modified to accommodate appropriate measurements from the distribution network and the DERs. By virtue of this approach, the resultant algorithm can cope with inaccuracies in the representation of the AC power flows, it avoids pervasive metering to gather the state of noncontrollable resources, and it naturally lends itself to a distributed implementation. Optimality claims are established in terms of tracking of the solution of a well-posed time-varying convex optimization problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

foresee™ (SWR-17-15)

foresee™ is a home energy management system (HEMS) that provides a user centric energy automation solution for residential building occupants. Built upon advanced control and machine learning algorithms, foresee™ intelligently manages the home appliances and distributed energy resources (DERs) such as photovoltaics and battery storage in a home. Unlike existing HEMS in the market, foresee™ provides a tailored home automation solution for individual occupants by learning and adapting to their preferences on cost, comfort, convenience and carbon. foresee™ improves not only the energy efficiency of the home but also its capability to provide grid services such as demand response. Highly reliable demand response services are likely to be incentivized by utility companies, making foresee™ economically viable for most homes.

Source record↗

Data from: 'Abiotic influences on continuous conifer forest structure across a subalpine watershed'

This package archives the core data used for analysis and inference in 'Abiotic influences on continuous conifer forest structure across a subalpine watershed' (Worsham et al., 2025). All data were collected in the East River, Washington Gulch, Slate River, and Coal Creek watersheds of Colorado. In the paper, we quantified the relative influence of climate, topographic, edaphic, and geologic factors on conifer stand structure and composition, and their functional relationships, at the watershed scale. We used waveform LiDAR data to derive spatially continuous stand structure metrics. We fused these with a species-level classification map to estimate tree species abundance. We applied generalized additive and generalized boosted models to evaluate the covariability of structural and compositional metrics with abiotic variables. The package contains the essential products required for reproducing our analysis and the tables and figures reported in the publication. The products comprise four classes: (1) geospatial data, (2) tabular data used for inferential analysis, (3) tabular data describing analytical results and performance statistics, and (4) a data user guide. (1) includes discretized waveform LiDAR data, locations and attributes of individual tree crowns, sampling locations and domain boundaries, a canopy height model, and raster files of estimated forest structural and compositional metrics at 100 m grid scale. (2) includes all response and explanatory variable values applied in inferential models. Response variables include conifer forest stand density, basal area, 95th percentile height, quadratic mean diameter, and others. Explanatory variables include climatic water deficit, actual evapotranspiration, elevation, heat load, soil available water content, and others. (3) includes results of training and testing several individual tree detection (ITD) algorithms, as well as inferential modeling results. (4) is a PDF user guide for this data package, including detailed descriptions and data dictionaries for all files. The data package root contains 17 assets: 8 compressed tape archive (.tar.gz) files, 5 comma-separated values (.csv) files, 3 Geographic Tagged Image File Format (GeoTIFF) (.tif) files, and 1 Portable Document Format (.pdf) file. The compressed .tar.gz archives contain ESRI shapefiles (.shp) .tif, compressed LASer (.laz), and .csv files. The archives must first be decompressed using the widely distributed command-line software utility TAR. All other files, including constituent files within the .tar.gz archives, can be opened in the open-source R statistical computing environment. Alternatively, .csv files may also be read in any simple text editor software or Microsoft Excel. Geospatial files including .shp and .tif files can also be opened in GIS software, such as QGIS (open-source) or ESRI ArcGIS (proprietary). The .pdf Data User Guide can be read with Adobe Acrobat Reader or other compatible readers.

2018 NEON and 2025 CHESS Campaigns↗

Next-Generation Performance-Based Regulation: Emphasizing Utility Performance to Unleash Power Sector Innovation

Performance-based regulation (PBR) enables regulators to reform hundred-year-old regulatory structures to unleash innovations within 21st century power systems. An old regulatory paradigm built to ensure safe and reliable electricity at reasonable prices from capital-intensive electricity monopolies is now adjusting to a new century of disruptive technological advances that change the way utilities make money and what value customers expect from their own electricity company. Advanced technologies are driving change in power sectors around the globe. Innovative technologies are transforming the way electricity is generated, delivered, and consumed. These emerging technology drivers include renewable generation, distributed energy resources such as distributed generation and energy storage, demand-side management measures such as demand-response, electric vehicles, and smart grid technologies and energy efficiency (EE). PBR enables regulators to recognize the value that electric utilities bring to customers by enabling these advanced technologies and integrating smart solutions into the utility grid and utility operations. These changes in the electric energy system and customer capacities means that there is an increasing interest in motivating regulated entities in other areas beyond traditional cost-of-service performance regulation. This report addresses best practices gleaned from more than two decades of PBR in practice, and analyzes how those best practices and lessons can be used to design innovative PBR programs. Readers looking for an introduction to PBR may want to focus on Chapters 1-5. Chapters 6 and 7 contain more detail for those interested in the intricate workings of PBR or particularly innovative PBR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Requirements for Application of Operator Support Technology across Multiple Plant Systems

Argonne National Laboratory (ANL) and Idaho National Laboratory (INL) are jointly developing and evaluating operator aids to: (i) facilitate more timely response to plant faults and grid disturbances; (ii) achieve better management of plant upsets and improved operator performance; and (iii) ultimately improve nuclear plant safety, production, and cost management. The overall objective of the collaborative effort in this third and final year of the project was to conduct human performance tests using nuclear plant operators in the Human Systems Simulation Laboratory (HSSL) control room at INL to assess the value of a computerized operator support system (COSS) as an aid to the operator. This report describes the work performed by ANL. A companion report describes the work performed by INL and the results of the human performance tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Expanding PV Value: Lessons Learned from Utility-led Distributed Energy Resource Aggregation in the United States

Distributed PV capacity in the United States has increased from about 0.4 Gigawatts (GW) in 2010 to 10.5 GW in 2017 (GTM Research and SEIA 2018). When distributed PV is coupled with other emerging distributed energy resources (DERs) like battery storage and electric vehicles (EVs) they can provide demand response, voltage regulation, and other grid services. When many DERs are aggregated and called upon to provide these services simultaneously they may offer the same or more value than large, centralized power producers. In the United States, utility efforts to aggregate DERs are in the nascent stage. If initial DER aggregation programs prove successful, it could open new value streams for PV and other emerging DERs, thereby expanding deployment and transforming the energy market. The literature on the scope, performance, and lessons learned from utility-led DER aggregation programs is limited. This report fills this research gap, first by surveying utility-led DER aggregation programs nationwide, and then providing a deeper analysis of five utility pilots. We compare lessons learned across the five cases to develop a list of common challenges and related solutions that other utilities might consider when developing next generation programs.

14 SOLAR ENERGY↗

Robust and resilient coordination of feeders with uncertain distributed energy resources: from real-time control to long-term planning

To enable flexible demand and ensure reliable and economical operation of distribution systems, we present a novel hierarchical scheme that actively coordinates responsive behind-the-meter grid resources, including distributed energy resources (DERs), to reliably manage each unbalanced distribution feeder and exploits the available flexibility to economically optimize the entire network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

14 SOLAR ENERGY↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters - CRADA 625 (Abstract)

Commercial heat pump water heater (CHPWH) systems significantly decarbonize the commercial and multifamily sectors by eliminating the reliance on gas-fired water heating. CHPWH systems are also well suited to include load shift controls that enable load-up and shed commands for supporting grid reliability and time-of-use pricing structure. However, they have not had wide adoption due to factors including price, complexity, and perceived risk. Although CHPWHs have been available in the US for decades, they have not made significant market gains in part because the systems have required significant and costly engineering design expertise and proved lackluster performance. Successful widespread market adoption requires a different approach; a shift from the current custom specialized expertise project design and installation to a repeatable approach that requires little specialized knowledge or expertise and can deliver persistent performance. Using this type of holistic systems approach requires effectively integrating four CHPWH system key components: primary air-to-water heat pumps; primary thermal storage tanks, a temperature maintenance system, and a control system which has capabilities to manage the primary heat pump cycles, any back-up, supplemental, or temperature maintenance heating, alarms, and grid connectivity allowing for demand response (DR), and/or load shifting. The project team has developed and will implement a suite of tools to support faster, less expensive, and more reliable field installations of CHPWH technology and with the resulting data used to further improve the tool set. These tools include: (1) A tool for optimizing system size and costs. (2) A tool that predicts annual energy use and overall system efficiency. (3) The Advanced Water Heater Specification (AWHS 8.0) defining the components of a full CHPWH system addressing performance requirements by climate zone. (4) The Qualified Products List: (QPL) of approved products that meet the specifications requirements. (5) Training materials including online on-demand modules, instructor-led training, and virtual interactive video tours of CHPWH installations in multifamily buildings. Demonstration site identification in low-income buildings in underserved communities is currently underway. Preliminarily, the team anticipates having three demonstrations in the Pacific Northwest and three in the Northeast for a total of six sites. After the demonstration sites are finalized, and M&V instrumentation installations are complete, the team will gather performance data and confirm whether the CHPWH systems perform as predicted and use the data to improve the existing tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Precision Time Protocol Performance Testing Over Optical Transport Network

The US Department of Energy Office of Electricity has partnered with Oak Ridge National Laboratory (ORNL) to find alternative precision timing solutions for the nation’s power grid. This effort is in response to the vulnerabilities identified in the Global Navigation Satellite System (GNSS), of which the US Global Positioning System (GPS) platform is a part. Additionally, Executive Order 139055 has highlighted the need for alternative or backup timing solutions. ORNL has established a Timing Lab and has been testing various technologies and timing devices as part of this effort. Precision Time Protocol (PTP), and the off-the-shelf timing devices and network connections that support it, are among the alternatives being tested. This work reports the accuracy of PTP over an Optical Transport Network (OTN) and is part of a series published by the Center for Alternative Synchronization and Timing (CAST).

24 POWER TRANSMISSION AND DISTRIBUTION↗

H2@Scale Concept Hydrogen Demand and Resources

The H2@Scale concept involves hydrogen as an energy intermediate. Hydrogen can be produced from various conventional and renewable energy sources including as a responsive load on the electric grid. Hydrogen has many current applications and many more potential applications, such as energy for transportation, as a feedstock for synthetic fuels, and to upgrade oil and biomass, heat for industry and buildings, and electricity storage. Owing to its flexibility and fungibility, a hydrogen intermediate could link energy sources that have surplus availability to markets that require energy or chemical feedstocks, benefiting both. This data release provides estimates on hydrogens serviceable consumption potential for possible hydrogen applications and the technical potential for producing hydrogen from various resources. We define the technical potential as the resource potential constrained by real-world geography and system performance, but not by economics.

Array↗

Validation of a High-Order Compact Code for Nonlinear Flows About Complex Geometric

The slides review computational requirements for nozzle exhaust flow and noise calculations and the current numerical method, validation of prefactored compact scheme on CAA benchmark problems, a curvilinear grid performance test of gust response of a Joukowski airfoil, airfoil surface RMS pressure distribution and far field noise radiation results for Joukowski airfoil in a vortical gust, boundary distance study for Joukowski airfoil problem, and performance of ICOMP parallel Macintosh cluster.

Hixon, Ray↗

High-Fidelity Multidisciplinary Sensitivity Analysis Framework for Multipoint Rotorcraft Optimization

A multidisciplinary, gradient-based sensitivity-analysis methodology is evaluated for optimization of rotorcraft configurations. The tightly coupled discipline models include physics-based fluid dynamics and rotorcraft comprehensive analysis. A discretely-consistent adjoint method accounts for sensitivities of the unsteady flow and unstructured, dynamic, over set grids, while sensitivities of structural responses to aerodynamic loads are computed using a complex-variable method. The methodology is applied to optimize the shape of UH-60A Blackhawk helicopter blades for hover and forward flight conditions. The objective of the multipoint design is to simultaneously increase the rotorcraft figure of merit in a hover flight and reduce the rotor power in a forward flight. Trimmed loose-coupling solutions for the baseline configuration are used to initiate the tight-coupling multidisciplinary analysis. Target thrust and rolling and pitching moments are enforced as optimization constraints. The optimized configuration improves the optimization metrics at both design points. The improved performance and all constraints are maintained over many revolutions beyond the optimization interval, satisfying the required flight conditions. Computational cost of the optimization cycle is assessed in a high-performance computing environment and found affordable for design of rotorcraft in general level-flight conditions.

Wang, Li↗

Feedback-Based Projected-Gradient Method For Real-Time Optimization of Aggregations of Energy Resources: Preprint

This paper develops an online optimization method to maximize the operational objectives of distribution-level distributed energy resources (DERs) while adjusting the aggregate power generated (or consumed) in response to services requested by grid operators. The design of the online algorithm is based on a projected-gradient method, suitably modified to accommodate appropriate measurements from the distribution network and the DERs. By virtue of this approach, the resultant algorithm can cope with inaccuracies in the representation of the AC power, it avoids pervasive metering to gather the state of noncontrollable resources, and it naturally lends itself to a distributed implementation. Optimality claims are established in terms of tracking of the solution of a well-posed time-varying optimization problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗

Transfer-Learnt Energy Models for Predicting Electricity Consumption in Buildings with Limited and Sparse Field Data

Modeling energy consumption is critical for energy-efficient utilization of the electric appliances in a building, smart grid programs (like demand-response), and many other smart home applications. State-of-the-art energy modeling techniques either rely on theoretical models, or extensive instrumentation of the building envelope to gather ``big" data to train a deep neural network. While theoretical models are often limited by their estimation accuracy, it is not always feasible to gather a significant amount of field data. In this paper, we explore transfer learning-based strategies to train much more accurate model for energy estimation when using a sparse field data. We transferred knowledge, in the form of data and parameters, from the simulation framework to the field data. We evaluated the efficacy of our approach on field data collected from six commercial buildings and our results indicate that transfer learning-based models trained over one month data can perform comparative (and in some cases better) than the state-of-the-art machine learning and deep learning solutions.

Jain, Milan↗