Search NASA⌕ Search

SEARCH · Search NASA

Results for “high voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Light weight, high power, high voltage dc/dc converter technologies

Power-conditioning weight reductions by orders of magnitude will be required to enable the megawatt-power-level space systems envisioned by the Strategic Defense Initiative, the Air Force, and NASA. An interagency program has been initiated to develop an 0.1-kg/kW dc/dc converter technology base for these future space applications. Three contractors are in the first phase of a competitive program to develop a megawatt dc/dc converter. Researchers at NASA Lewis Research Center are investigating innovative converter topology control. Three different converter subsystems based on square wave, resonant, and super-resonant topologies are being designed. The components required for the converter designs cover a wide array of technologies. Two different switches, one semiconductor and the other gas, are under development. Issues related to thermal management and material reliability for inductors, transformers, and capacitors are being investigated in order to maximize power density. A brief description of each of the concepts proposed to meet the goals of this program is presented.

Kraus, Robert↗

High voltage plasma sheath analysis related to TSS-1

On the first mission of the Tethered Satellite System (TSS-1), a 1.8 m diameter spherical satellite will be deployed a distance of 20 km above the space shuttle Orbiter on an insulated conducting tether. The satellite will be held at electric potentials up to 5000 volts positive with respect to the ambient plasma. Due to the passage of the conducting tether through the Earth's magnetic field, an emf will be created, driving electrons down the tether to the orbiter, out through an electron gun into the ionosphere and back into the positive biased satellite. Instrumentation on the satellite will measure electron flow to the surface at several locations, but these detectors have a limited range of acceptance angle. The problem addressed herein is the determination of the electron current distribution over the satellite surface and the angle of incidence of the incoming electrons relative to the surface normal.

Sheldon, John W.↗

LEO spacecraft leakage current and discharging phenomena - TRW LDEF SP-HVDE (space plasma-high voltage drainage experiment)

Two identical SP-HVDE trays were flown in the NASA 5.75-year LDEF (Long Duration Exposure Facility), one near the leading edge and the other near the trailing edge, in the LEO (low earth orbit) environment. Each experiment tray consisted of six assemblies with each made of Kapton dielectric samples of varying thicknesses (i.e., 2 mils, 3 mils, and 5 mils) biased under +/- 300 V, +/- 500 V, and +/- 1000 V. The objectives have been successfully achieved by measuring the first post-flight long-term (i.e. roughly 8-month experiment) average leakage current through 95 percent measurable coulombmeters and surface materials.

Yaung, J. Y.↗

Temporal study of the current collected by a Langmuir probe biased to high voltages in the wake behind a conducting body

The temporal evolution of the voltage-current characteristic of a spherical Langmuir probe in the near-wake region of a conducting body is investigated in a pulsed plasma device. Measurements of the current collected by a sphere placed on axis behind a conducting disk are presented as a function of the bias voltage and time. The bias voltage on the collecting sphere is large enough, ranging from +500 to -3000 V, to attract ions or electrons across the wake region. In addition, plasma potential profiles as a function of sphere bias voltage and time throughout the nearwake and midwake region are presented. It is found that for a negative sphere bias a threshold voltage exists for current collection. This threshold voltage decreases during the formation of the wake behind the conducting disk. Potential measurements indicate that the sheath region around the negatively biased sphere contracts as the wake region establishes itself. This contraction of the sheath region increases the electric field attracting ions to the sphere and decreases the threshold voltage for current collection. For positive sphere bias voltage the current collected by the sphere does not exhibit a threshold voltage but is monotonically increasing.

Meassick, S.↗

Overview of the effects of neutral gas releases on high-voltage sounding rocket platforms

Four recent sounding rocket experiments demonstrate that the release of neutral gas from both positively and negatively charged vechicles returns the vehicle potential to near the plasma potential. Early active experiment payloads, CHARGE-2 and Space Power Experiments Aboard Rockets 1 (SPEAR-1) observed enhanced currents from/to the vehicles during unplanned attitude thruster firings. The follow-on CHARGE-2B ad SPEAR-3 payloads directly measured the changes to the vehicle potential caused by both planned argon and unplanned nitrogen releases. The gas releases from positively charged CHARGE-2B consistently reduced the potential to 20-50 V, wheras the gas releases from negatively charged SPEAR-3 brought the potential to between -200 and -500 V. The difference in grounding levels for positively and negatively charged payloads suggests that the gas responsible for grounding is near the vehicle, within a small fraction of the sheath size.

Berg, G. A.↗

High-Voltage MOSFET Switching Circuit

Circuit reliably switches power at supply potential of minus 1,500 V, with controlled frequency and duty cycle. Used in argon-plasma ion-bombardment equipment for texturing copper electrodes, as described in "Texturing Copper To Reduce Secondary Emission of Electrons" (LEW-15898), also adapted to use in powering gaseous flash lamps and stroboscopes.

Jensen, Kenneth A.↗

Insulation Requirements of High-Voltage Power Systems in Future Spacecraft

The scope, size, and capability of the nation's space-based activities are limited by the level of electrical power available. Long-term projections show that there will be an increasing demand for electrical power in future spacecraft programs. The level of power that can be generated, conditioned, transmitted, and used will have to be considerably increased to satisfy these needs, and increased power levels will require that transmission voltages also be increased to minimize weight and resistive losses. At these projected voltages, power systems will not operate satisfactorily without the proper electrical insulation. Open or encapsulated power supplies are currently used to keep the volume and weight of space power systems low and to protect them from natural and induced environmental hazards. Circuits with open packaging are free to attain the pressure of the outer environment, whereas encapsulated circuits are imbedded in insulating materials, which are usually solids, but could be liquids or gases. Up to now, solid insulation has usually been chosen for space power systems. If the use of solid insulation is continued, when voltages increase, the amount of insulation for encapsulation also will have to increase. This increased insulation will increase weight and reduce system reliability. Therefore, non-solid insulation media must be examined to satisfy future spacecraft power and voltage demands. In this report, we assess the suitability of liquid, space vacuum, and gas insulation for space power systems.

Qureshi, A. Haq↗

High Voltage TAL Performance

The performance of a two-stage, anode layer Hall thruster was evaluated. Experiments were conducted in single and two-stage configurations. In single-stage configuration, the thruster was operated with discharge voltages ranging from 300 to 1700 V. Discharge specific impulses ranged from 1630 to 4140 sec. Thruster investigations were conducted with input power ranging from 1 to 8.7 kW, corresponding to power throttling of nearly 9: 1. An extensive two-stage performance map was generated. Data taken with total voltage (sum of discharge and accelerating voltage) constant revealed a decrease in thruster efficiency as the discharge voltage was increased. Anode specific impulse values were comparable in the single and two-stage configurations showing no strong advantage for two-stage operation.

Jacobson, David T.↗

Charging of the International Space Station Due to Its High Voltage Solar Arrays

The International Space Station (ISS) has the highest voltage solar arrays ever flown in Low Earth Orbit (LEO). The ISS power system (and structure) ground is at the negative end of the 160 V solar arrays. Due to plasma current collection balance that must be maintained in LEO, it is possible for a spacecraft to charge negative of the ambient plasma by up to its entire solar array voltage (-160 V for ISS).

Ferguson, Dale C.↗

Ground Tests of High-Voltage Solar Arrays Immersed in a Low Density Plasma

Five different types of solar arrays have been tested in large vacuum chamber. Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness does not improve measured array parameters. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 pm coverglass thickness and 60 V for the sample with 150 urn coverglass thickness.

Vayner, Boris↗

Safety Performance of Small Lithium-Ion Cells in High Voltage Batteries

Topics covered include: Small-cell EAPU work done by NASA-JSC & COM DEV; Looking at safety features (short circuit protection - PTCs); Early tests showed that long strings do not withstand short circuit; a) Some PTCs experience large negative voltages; b) Destructive results. Solution: group cells into shorter substrings, with bypass diodes Work included: a) Tests with single cells shorted; b) Tests with single cells with imposed-negative voltages; c) 6s, 7s and 8s string shorts; and d) Tests with protection scheme in place, on 12s and 41s x 5p.

Cowles, Philip R.↗

Performance of High Voltage Modules Under Abuse Operations

The Electric Auxiliary Power Unit (EAPU) or the Advanced Hydraulic Power System (AHPS) is a Shuttle Upgrade program. Of the two battery design approaches that were considered in support of this program, the current paper concentrates on the testing performed on the small-cell approach. Testing performed at both ComDev Space, Canada and at NASA-JSC is described in this paper. Testing included those under mission profile conditions and off-nominal abusive conditions.

Jeevarajan, Judith A.↗

Rectenna for high-voltage applications

An energy transfer system is disclosed. The system includes patch elements, shielding layers, and energy rectifying circuits. The patch elements receive and couple radio frequency energy. The shielding layer includes at least one opening that allows radio frequency energy to pass through. The openings are formed and positioned to receive the radio frequency energy and to minimize any re-radiating back toward the source of energy. The energy rectifying circuit includes a circuit for rectifying the radio frequency energy into dc energy. A plurality of energy rectifying circuits is arranged in an array to provide a sum of dc energy generated by the energy rectifying circuit.

Epp, Larry W.↗

Space Plasma Testing of High-Voltage Thin-Film Solar Arrays with Protective Coatings

This paper gives an overview of the space plasma test program for thin-film photovoltaics (TFPV) technologies developed at the Air Force Research Laboratory (AFRL). The main objective of this program is to simulate the effects of space plasma characteristic of LEO and MEO environments on TFPV. Two types of TFPV, amorphous silicon (a-Si) and copper-indium-gallium-diselenide (CIGS), coated with two types of thin-film, multifunctional coatings were used for these studies. This paper reports the results of the first phase of this program, namely the results of preliminary electrostatic charging, arcing, dielectric breakdown, and collection current measurements carried out with a series of TFPV exposed to simulated space plasma at the NASA Glenn Plasma Interaction Facility. The experimental data demonstrate that multifunctional coatings developed for this program provide effective protection against the plasma environment while minimizing impact on power generation performance. This effort is part of an ongoing program led by the Space Vehicles Directorate at the AFRL devoted to the development and space qualification of TFPV and their protective coatings.

Tlomak, Pawel↗