Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedence analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Theoretical analyses on Apollo lunar surface electrical properties experiment transmitter antenna.

The purpose of this study is to investigate the characteristics of the transmitter antenna of lunar surface electrical properties experiment. It is desirable to evaluate the current distribution, far-field radiation pattern and input impedance of the transmitter antenna in order to determine the electromagnetic sounding effects from the lunar subsurface. The analysis is based on the treatise of the long wire antenna with passive loadings. Both cases of the antenna placed in free space and in a dissipative medium are taken into consideration.-

Yu, I.-P.↗

Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program

An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.

Beckemeyer, R. J.↗

The practical operational-amplifier gyrator circuit for inductorless filter synthesis

A literature is reported for gyrator circuits utilizing operational amplifiers as the active device. A gyrator is a two port nonreciprocal device with the property that the input impedance is proportional to the reciprocal of the load impedance. Following an experimental study, the gyrator circuit with optimum properties was selected for additional testing. A theoretical analysis was performed and compared to the experimental results for excellent agreement.

Sutherland, W. C.↗

Plane waves at or near grazing incidence in the parabolic approximation

The parabolic approximation for the acoustic equations of motion is applied to the study of the sound field generated by a plane wave at or near grazing incidence to a finite impedance boundary. It is shown how this approximation accounts for effects neglected in the usual plane wave reflection analysis which, at grazing incidence, erroneously predicts complete cancellation of the incident field by the reflected field. Examples are presented which illustrate that the solution obtained by the parabolic approximation contains several of the physical phenomena known to occur in wave propagation near an absorbing boundary.

Mcaninch, G. L.↗

A design procedure for the phase-controlled parallel-loaded resonant inverter

High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.

King, Roger J.↗

Analysis of radiometer calibration effects with TOUCHSTONE

The microwave circuit analysis program TOUCHSTONE is used to study two effects of importance in radiometer calibration. The two effects are impedance mismatches at the antenna-air and cold load-air interfaces and dissipatives losses, which radiate thermal noise into the system. The results predicted by TOUCHSTONE are shown to be in very close agreement with earlier results obtained by purely analytical methods. The techniques used in establishing the circuit models and in processing the resulting data are described in detail.

Stanley, William D.↗

Demand Response Analysis for Different Residential Personas in a Comfort-Driven Behavioral Context

Low demand response (DR) participation and high program drop-out rates continue to impede DR goals that could save up to $13 billion in annual grid expansion and electricity demand costs. Yet, the literature lacks a thorough understanding of how different residential customer segments enrolled in DR programs respond to utility signals in view of occupant comfort considerations. The objective of this study is to gain a clear understanding of the effects of four different customer personas on residential DR. Given current data limitations, this work developed an array of hypothetical personas with varied priorities, activity levels, and comfort thresholds based on demographic variables that have been found in previous studies to influence energy consumption. A BEopt DR model for a reference residential single-family building located in Colorado was built to isolate the effect of differences in buildings or climate. The results provide useful evidence on how persona-comfort differences lead to significant deviations in DR goals (especially peak demand reduction), ranging from 0.1% to 20%. This work presents a novel framework representing comfort preferences in DR models. The data generated, albeit synthetic, and the results could inform DR program design considerations of how different people respond to different comfort priorities.

BEopt↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

Humphreys, William M., Jr.↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Plasticizer-Free Gradient-Crosslinked Polyurethane Electrolyte for Room-Temperature Solid-State Lithium Batteries

Polymer-based solid-state electrolytes are promising for next-generation lithium metal batteries, yet their limited ionic conductivity and mechanical stability at ambient conditions remain key challenges. Herein, we report a novel gradient crosslinked polymer electrolyte (PU/PUA/PU) synthesized via a sequential in situ UV-curing process that integrates a mechanically robust polyurethane acrylate (PUA) core with soft linear polyurethane (PU) interfaces. This all-solid membrane operates without any liquid plasticizer and the interfacial PU layers ensure low interfacial resistance and intimate electrode contact, while the PUA core provides enhanced dimensional stability and dendrite suppression. As a result, the gradient electrolyte delivers an impressive ∼2.6 × 10 −4 S cm −1 ionic conductivity at 25 °C (two orders of magnitude higher than conventional PEO) and remains electrochemically stable >5 V (vs Li + /Li). Structural analysis confirms the formation of a well-defined crosslinked network with suppressed crystallinity and expanded interchain spacing. Electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) further validate these properties. When applied in a Li||NMC811 cell, the PU/PUA/PU electrolyte delivers stable cycling with high capacity at both 60 °C and 25 °C, demonstrating its potential for room-temperature solid-state battery applications without reliance on plasticizers or heating. In conclusion, this gradient design offers a practical path toward ambient-condition operation of solid-state lithium batteries, providing a paradigm for overcoming the traditional trade-off between ionic conductivity and mechanical robustness.

25 ENERGY STORAGE↗

Multipole-based Cable Braid Magnetic Penetration Model for Conducting Wires

In this report, we investigate the effects of conductor losses in a multipole-based cable braid magnetic penetration model. Our multipole model uses a mesh of the actual cable geometry, which enables us to model more complicated structures. After summarizing the first principles model formulation, we consider a one-dimensional array of wires, for which an analytical solution is known in the lossless case. We extend this solution to the lossy case by using a complex-valued radius. We also model this structure analytically using a conformal-mapping solution. We then compare both the self-impedance and the transfer impedance results from our first principles cable braid electromagnetic penetration model to those obtained using the analytical solutions. An analysis for various frequencies (and skin depths) usually encountered in cable modeling is reported. These results are found in good agreement up to a radius to half spacing ratio of about 0.7, demonstrating a robustness needed for many commercial and non-commercial cables.

36 MATERIALS SCIENCE↗

Radiation and scattering by thin-wire structures in the complex frequency domain

Piecewise-sinusoidal expansion functions and Galerkin's method are employed to formulate a solution for an arbitrary thin-wire configuration in a homogeneous conducting medium. The analysis is performed in the real or complex frequency domain. In antenna problems, the solution determines the current distribution, impedance, radiation efficiency, gain and far-field patterns. In scattering problems, the solution determines the absorption cross section, scattering cross section and the polarization scattering matrix. The electromagnetic theory is presented for thin wires and the forward-scattering theorem is developed for an arbitrary target in a homogeneous conducting medium.

Richmond, J. H.↗

Rotordynamic Analysis of the SSME Turbopumps Using Reduced Models

Alternative methods for the rotor-dynamic and sensitivity analysis of large rotor systems are examined. The methods are assessed for their ability to utilize accurate models of reduced size along with effective procedures for describing the dynamic behavior of the systems. Frequency response-based techniques are developed for determining the steady state response to imbalance of the space shuttle main engine (SSME) turbopumps and the related eigenvalue problem. The rotor and housing are represented by reduced receptances associated with their coupling points. The housing may be described by all of its normal modes within a frequency range of interest. The effects of truncated higher and lower modes are accounted for in an approximate manner. A procedure is described for determining the sensitivity of the coupling forces to changes in the coupling elements and rotor speed of the turbopump systems. In addition, an eigenvalue sensitivity analysis technique is adopted for application to the systems. Computer programs were developed for the numerical implementation of the impedance and eigenvalue sensitivity formulated in this study.

Noah, S. T.↗

Coupled rotor-body vibrations with inplane degrees of freedom

In an effort to understand the vibration mechanisms of helicopters, the following basic studies are considered. A coupled rotor-fuselage vibration analysis including inplane degrees of freedom of both rotor and airframe is performed by matching of rotor and fuselage impedances at the hub. A rigid blade model including hub motion is used to set up the rotor flaplag equations. For the airframe, 9 degrees of freedom and hub offsets are used. The equations are solved by harmonic balance. For a 4-bladed rotor, the coupled responses and hub loads are calculated for various parameters in forward flight. The results show that the addition of inplane degrees of freedom does not significantly affect the vertical vibrations for the cases considered, and that inplane vibrations have similar resonance trends as do flapping vibrations.

Ming-Sheng, H.↗

Field-Coupled Water Splitting with Metal-Free Donor–Acceptor Covalent Organic-Framework Junctions

Advancing metal-free electrocatalysts for hydrogen and oxygen evolution reactions (HER/OER) across acidic and alkaline media requires coordinated control of intermediate binding thermodynamics, interfacial charge delivery, and near-electrode transport dynamics. Here, we design amide-linked benzene–triazine covalent organic frameworks (BTA/TzTA-Hz COFs) and integrate them with carbon nanotubes (CNTs) to form COF–CNT junctions that establish a built-in interfacial electric field. Density functional theory (DFT) and electrostatic potential maps indicate complementary active motifs, with benzene-proximal fragments associated with HER and triazine-proximal motifs associated with OER. CNT integration shifts the contact-potential difference by ≈0.20 V, while operando electrochemical impedance spectroscopy suggests partially separable high-frequency junction-charging and lower-frequency Faradaic/transport responses. A 300 mT static magnetic field lowers the HER and OER overpotentials by tens of millivolts. Under anodic bias, the effective interfacial charging capacitance increases, and Mott–Schottky analysis shows an apparent ∼0.15 V flat-band shift with an essentially unchanged slope. Together, these observations are consistent with field-perturbed interfacial charging and altered bias partitioning. Field-dependent impedance and bubble imaging are consistent with magnetohydrodynamic convection that promotes bubble detachment and near-electrode mass transport for both half-reactions, and they reveal an OER-specific high-frequency perturbation under anodic bias. Under field, the heterostructure reaches an OER onset overpotential of ∼261 mV and requires an overpotential of 366 mV at 10 mA cm –2 in alkaline electrolyte. These results illustrate how reticular-framework chemistry, junction engineering, and both built-in and applied fields can program reactivity through interfacial electrostatics and near-electrode transport in organic-framework electrocatalysts.

Garcia-Enriquez, Lissette [Univ. of Texas at El Pa↗

Measured and calculated transmission losses of sound waves through a helium layer

An experiment was performed to measure the transmission losses of sound waves traversing an impedance layer. The sound emanated from a point source and the impedance layer was created by a low-speed helium jet. The transmission losses measured were of the order of 12 db for frequencies of the source between 4 and 12 kHz. These losses are greater than those predicted from analysis when the observer angle is less than about 35 deg, but less than those predicted for larger observer angles. The experimental results indicate that appreciable noise reductions can be realized for an observer shielded by an impedance layer, irrespective of his position relative to the source of sound.

Norum, T. D.↗

Norton-Thevenin Receptance Coupling (NTRC) as a Payload Design Tool

The NASA Engineering and Safety Center (NESC) is funding a study to develop an alternate method for performing coupled loads analysis called Norton-Thevenin Receptance Coupling (NTRC). NTRC combines Receptance Coupling (RC), a frequency-domain synthesis method and Norton-Thevenin (NT) theory, an impedance based approach for simulating the interaction between dynamic systems. The goal of developing the NTRC method is to provide a tool that payload developers can use to reduce the conservatism in defining preliminary design loads, assess the impact of design changes between formal load cycles, and to perform trade studies for design optimization with a minimum amount of data required from the launch vehicle (LV) provider. NTRC also has the ability to perform parametric loads analysis where many different design configurations can be evaluated. This will result in cost and schedule benefits to the payload developer that are currently not possible under the standard coupled loads analysis (CLA) flow where typically only 2-3 official load cycles are performed by the LV provider over the life of a payload program. NTRC is not envisioned as a replacement for the official load cycles performed by the LV provider but rather as a means to address the types of design issues faced by the payload developer before and between official load cycles.The presentation provides an overview of the NTRC methodology and discusses how NTRC can be used to replicate the results from a standard LV CLA. The presentation covers the benchmarking that has been performed as part of the NESC study to demonstrate the accuracy of the technique for both frequency and time domain dynamic analyses. Future plans for benchmarking the NTRC approach against CLA results for NASAs Space Launch System (SLS) and commercial launch vehicles are discussed and the role that NTRC is envisioned to play in the payload development cycle.

Structural Dynamics↗