MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=about 15 orbits/day].

NEAR IR IMAGERY↗

MISR Level 1B1 Radiance Data (MI1B1_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 meters - < 500 meters; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly, about 15 orbits/day, Daily - < Weekly].

EOSDIS↗

MISR Level 1B1 Radiance Data (MI1B1_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km; Longitude_Resolution=1.1 km; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=about 15 orbits/day].

AM-1↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Temporal_Resolution=about 15 orbits/day].

AM-1↗

Evaluation of Portable Programming Models to Accelerate LArTPC Detector Simulations

The Liquid Argon Time Projection Chamber (LArTPC) technology is widely used in high energy physics experiments, including the upcoming Deep Underground Neutrino Experiment (DUNE). Accurately simulating LArTPC detector responses is essential for analysis algorithm development and physics model interpretations. Accurate LArTPC detector response simulations are computationally demanding, and can become a bottleneck in the analysis workflow. Compute devices such as General-Purpose Graphics Processing Units (GPGPUs) have the potential to substantially accelerate simulations compared to traditional CPU-only processing. The software development for these compute accelerators often carries the cost of specialized code refactorization and porting to match the target hardware architecture. With the rapid evolution and increased diversity of the computer architecture landscape, it is highly desirable to have a portable solution that also maintains reasonable performance. We report our ongoing effort in evaluating Kokkos as a basis for this portable programming model using LArTPC simulations in the context of the Wire-Cell Toolkit, a C++ library for LArTPC simulations, data analysis, reconstruction and visualization.

47 OTHER INSTRUMENTATION↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗

MISR Instrument Data Visualization

The MISR Interactive eXplorer (MINX) software functions both as a general-purpose tool to visualize Multiangle Imaging SpectroRadiometer (MISR) instrument data, and as a specialized tool to analyze properties of smoke, dust, and volcanic plumes. It includes high-level options to create map views of MISR orbit locations; scrollable, single-camera RGB (red-greenblue) images of MISR level 1B2 (L1B2) radiance data; and animations of the nine MISR camera images that provide a 3D perspective of the scenes that MISR has acquired. NASA Tech Briefs, September 2008 55 The plume height capability provides an accurate estimate of the injection height of plumes that is needed by air quality and climate modelers. MISR provides global high-quality stereo height information, and this program uses that information to perform detailed height retrievals of aerosol plumes. Users can interactively digitize smoke, dust, or volcanic plumes and automatically retrieve heights and winds, and can also archive MISR albedos and aerosol properties, as well as fire power and brightness temperatures associated with smoke plumes derived from Moderate Resolution Imaging Spectroradiometer (MODIS) data. Some of the specialized options in MINX enable the user to do other tasks. Users can display plots of top-of-atmosphere bidirectional reflectance factors (BRFs) versus camera-angle for selected pixels. Images and animations can be saved to disk in various formats. Also, users can apply a geometric registration correction to warp camera images when the standard processing correction is inadequate. It is possible to difference the images of two MISR orbits that share a path (identical ground track), as well as to construct pseudo-color images by assigning different combinations of MISR channels (angle or spectral band) to the RGB display channels. This software is an interactive application written in IDL and compiled into an IDL Virtual Machine (VM) ".sav" file.

Nelson, David↗

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Evaluation of an Anthropometric Human Body Model for Simulated EVA Task Assessment

One of the more mission-critical tasks performed in space is extravehicular activity (EVA) which requires the astronaut to be external to the station or spacecraft, and subsequently at risk from the many threats posed by space. These threats include, but are not limited to: no significant atmosphere, harmful electromagnetic radiation, micrometeoroids, and space debris. To protect the astronaut from this environment, a special EVA suit is worn which is designed to maintain a sustainable atmosphere (at 1/3 atmosphere) and provide protection against the hazards of space. While the EVA suit serves these functions well, it does impose limitations on the astronaut as a consequence of the safety it provides. Since the astronaut is in a virtual vacuum, any atmospheric pressure inside the suit serves to pressurize the suit and restricts mobility of flexible joints (such as fabric). Although some of the EVA suit joints are fixed, rotary-style joints, most of the mobility is achieved by the simple flexibility of the fabric. There are multiple layers of fabric, each of which serves a special purpose in the safety of the astronaut. These multiple layers add to the restriction of motion the astronaut experiences in the space environment. Ground-based testing is implemented to evaluate the capability of EVA-suited astronauts to perform the various tasks in space. In addition to the restriction of motion imposed by the EVA suit, most EVA activity is performed in a micro-gravity (weight less) environment. To simulate weightlessness EVA-suited testing is performed in a neutral buoyancy simulator (NBS). The NBS is composed of a large container of water (pool) in which a weightless environment can be simulated. A subject is normally buoyant in the pressurized suit; however he/she can be made neutrally buoyant with the addition of weights. In addition, most objects the astronaut must interface with in the NBS sink in water and flotation must be added to render them "weightless". The implementation of NBS testing has proven to invaluable in the assessment of EVA activities performed with the Orbiter and is considered to be a key step in the construction of the International Space Station (ISS). While the NBS testing is extremely valuable, it does require considerable overhead to maintain and operate. It has been estimated that the cost of utilizing the facility is approximately $10,000 per day. Therefore it is important to maximize the utility of NBS testing for optimal results. One important aspect to consider in any human/worksite interface is the considerable wealth of anthropometric and ergonomic data available. A subset of this information specific to EVA activity is available in NASA standard 3000. The difficulty in implementing this data is that most of the anthropometric information is represented in a two-dimensional format. This poses some limitations in complete evaluation of the astronaut's capabilities in a three-dimensional environment. Advances in computer hardware and software have provided for three-dimensional design and implementation of hardware with the advance of computer aided design (CAD) software. There are a number of CAD products available and most companies and agencies have adopted CAD as a fundamental aspect of the design process. Another factor which supports the use of CAD is the implementation of computer aided manufacturing (CAM) software and hardware which provides for rapid prototyping and decreases the time to product in the design process. It is probable that most hardware to be accessed by astronauts in EVA or IVA (intravehicular activity) has been designed by a CAD system, and is therefore represented in three-dimensional space for evaluation. Because of the implementation of CAD systems and the movement towards early prototyping, a need has arisen in industry and government for tools which facilitate the evaluation of ergonomic consideration in a three-dimensional environment where the hardware has been designed by the CAD tools. One such product is Jack which was developed by the University of Pennsylvania with funding from several government agencies, including NASA. While the primary purpose of Jack is to model human figures in a ground-based (gravity) environment, it can be utilized to evaluate EVA-suited activities as well. The effects of simulated gravity must be turned off by turning off "behaviors". Although Jack provides human figures for manipulation, the primary instrument to be evaluated for EVA mobility is the work envelope provided by the EVA suit. An EVA Jack suit model has been developed by NASA-JSC and was utilized in this study. This suit model provided a more restrictive motion environment as expected for an EVA suited subject. As part of this study, the anthropometric dimensions for a 50th percentile male were compared with basic anthropometric data and were found to be representative for the population group expected in the NASA flight program. The joints for the suit were created in a manner which provided consistent performance with EVA reach envelopes published in NASA standard #3000.

Etter, Brad↗

Phytoplankton-Fluorescence-Lifetime Vertical Profiler

A battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency

Fernandez, Salvador M.↗

Modeling of Vertical Motor-driven Pump for Simulation of a Fault Signature \\ for Condition Monitoring

As part of the ongoing effort to transition from preventive maintenance strategies to condition-based maintenance strategies in nuclear power plants, there is significant reliance on using machine learning techniques. To develop a robust machine learning model that can diagnose all the fault modes of a vertical motor-driven pump, data capturing the unique signature of each fault mode is required. In practice, it is difficult to collect or capture data that captures all the fault modes from a single plant site. So to address this situation, a computational model of a vertical motor-driven pump is developed using the multipurpose finite element software COMSOL Multiphysics. The developed model is used to generate simulated data under normal operation and is compared with the vibration data collected using vibration sensors. Once the simulation model is verified under normal operating condition, simulated data for the fault mode for which minimal or no evidence is available in historical plant process data is developed. This simulated data is used to develop fault signatures to achieve robust predictive models. This paper presents modeling details and verification of the model that can used to generate data for fault modes that are not available at a plant site for condition monitoring purpose.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mission planning for space based satellite surveillance experiments with the MSX

The Midcourse Space Experiment is a BMDO-sponsored scientific satellite set for launch within the year. The satellite will collect phenomenology data on missile targets, plumes, earth limb backgrounds and deep space backgrounds in the LWIR, visible and ultra-violet spectral bands. It will also conduct functional demonstrations for space-based space surveillance. The Space-Based Visible sensor, built by Lincoln Laboratory, Massachusetts Institute of Technology, is the primary sensor on board the MSX for demonstration of space surveillance. The SBV Processing, Operations and Control Center (SPOCC) is the mission planning and commanding center for all space surveillance experiments using the SBV and other MSX instruments. The guiding principle in the SPOCC Mission Planning System was that all routine functions be automated. Manual analyst input should be minimal. Major concepts are: (I) A high level language, called SLED, for user interface to the system; (2) A group of independent software processes which would generally be run in a pipe-line mode for experiment commanding but can be run independently for analyst assessment; (3) An integrated experiment cost computation function that permits assessment of the feasibility of the experiment. This paper will report on the design, implementation and testing of the Mission Planning System.

Sridharan, R.↗

Creating a Simulation Platform for Research and Development of Advanced Control Methods

Advanced nuclear reactors are essential to meet the changing energy requirements throughout both the United States and the rest of world. In addition to other features, they are designed to enable deployment in remote locations and operate in a fully (or near-fully) autonomous manner, which will require a new control paradigm. To realize autonomously operating reactors, the U.S. Department of Energy’s Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program conducts research and development into the enabling technologies and methods needed, including digital twins, machine learning, and risk modeling, in addition to various types of control methods. These technologies and methods are the key foundations needed to achieve fully autonomous systems. To develop and evaluate the technologies and methods necessary for achieving autonomous operations, it is critical to identify a software tool capable of integrating all the required elements. In surveying the available solutions, no software platforms were identified that could accomplish what was needed without introducing drawbacks. This challenge was the motivation for the current effort: to develop a software platform that can seamlessly integrate autonomouscontrol-enabling technologies and methods, allowing for accelerated research and development and transfer of ideas. The resulting platform, known as the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND), is Python-based, and leverages open-source tools to provide flexibility and facilitate building upon prior research. It is designed to enable advanced reactor developers to deploy and test advanced control technologies and methods coupled with their own models, solutions, and hardware. Given the substantial undertaking of developing such a platform, the current effort focused on laying down scalable, flexible software foundations and infrastructure, then demonstrating the platform via a use case. These foundations included developing generic modules, which contain the base variable and system blocks (the information and functional building blocks, respectively, that can be used to design a simulation) and the data handling and storage blocks needed to exchange information between the various blocks; as well as enablingtechnology-specific modules. This platform was evaluated via a use case, which was to simulate and control a process for the Microreactor Automated Control System (MACS) test bed. While MACS is not currently directly coupled to any specific microreactor physics, it was initially developed in concert with the Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor, and so the MARVEL physics are used here. As part of this use case, several enabling-technology-specific blocks within COMMAND were integrated, including a proportional integral derivative (PID) control block, a Reactor Excursion and Leak Analysis Program (RELAP5-3D) block, and an anomaly detection block. The COMMAND software platform was successfully demonstrated to achieve the scalability and flexibility objectives of this effort and will be leveraged by the program’s research efforts to advance state of the art control methodologies towards autonomous operations of advanced reactors. As new use cases are created and implemented, it is anticipated that COMMAND will continue to grow and evolve to meet new requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LipidOz enables automated elucidation of lipid carbon–carbon double bond positions from ozone-induced dissociation mass spectrometry data

Lipids play essential roles in many biological processes and disease pathology, but unambiguous identification of lipids is complicated by the presence of multiple isomeric species differing by fatty acyl chain length, stereospecifically numbered (sn) position, and position/stereochemistry of double bonds. Conventional liquid chromatography-mass spectrometry (LC-MS/MS) analyses enable the determination of fatty acyl chain lengths (and in some cases sn position) and number of double bonds, but not carbon-carbon double bond positions. Ozone-induced dissociation (OzID) is a gas-phase oxidation reaction that produces characteristic fragments from lipids containing double bonds. OzID can be incorporated into ion mobility spectrometry (IMS)-MS instruments for the structural characterization of lipids, including additional isomer separation and confident assignment of double bond positions. The complexity and repetitive nature of OzID data analysis and lack of software tool support have limited the application of OzID for routine lipidomics studies. Here, we present an open-source Python tool, LipidOz, for the automated determination of lipid double bond positions from OzID-IMS-MS data, which employs a combination of traditional automation and deep learning approaches. Our results demonstrate the ability of LipidOz to robustly assign double bond positions for lipid standard mixtures and complex lipid extracts, enabling practical application of OzID for future lipidomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An in-situ conductometric apparatus for physicochemical characterization of solutions and in-line monitoring of separation processes at elevated temperatures and pressures

Specific conductance and frequency-dependent resistance (impedance) data are widely utilized for understanding the physicochemical characteristics of aqueous and non-aqueous fluids and for evaluating the performance of chemical processes. However, the implementation of such an in-situ probe in high-temperature and high-pressure environments is not trivial. This work provides a description of both the hardware and software associated with implementing a parallel-type in-situ electrochemical sensor. The sensor can be used for in-line monitoring of thermal desalination processes and for impedance measurements in fluids at high temperature and pressure. Further, a comparison between the experimental measurements on the specific conductance in aqueous sodium chloride solutions and the conductance model demonstrate that the methodology yields reasonable agreement with both the model and literature data. A combination of hardware components, a software-based correction for experimental artifacts, and computational fluid dynamics (CFD) calculations used in this work provide a sound basis for implementing such in-situ electrochemical sensors to measure frequency-dependent resistance spectra.

47 OTHER INSTRUMENTATION↗

Processing TES Level-1B Data

TES L1B Subsystem is a computer program that performs several functions for the Tropospheric Emission Spectrometer (TES). The term "L1B" (an abbreviation of "level 1B"), refers to data, specific to the TES, on radiometric calibrated spectral radiances and their corresponding noise equivalent spectral radiances (NESRs), plus ancillary geolocation, quality, and engineering data. The functions performed by TES L1B Subsystem include shear analysis, monitoring of signal levels, detection of ice build-up, and phase correction and radiometric and spectral calibration of TES target data. Also, the program computes NESRs for target spectra, writes scientific TES level-1B data to hierarchical- data-format (HDF) files for public distribution, computes brightness temperatures, and quantifies interpixel signal variability for the purpose of first-order cloud and heterogeneous land screening by the level-2 software summarized in the immediately following article. This program uses an in-house-developed algorithm, called "NUSRT," to correct instrument line-shape factors.

DeBaca, Richard C.↗

Measurement and Analysis of Atmospheric Spectral Optical Depths with NASA Ames Airborne Sunphotometers During TARFOX and ACE-2

In accordance with the scope of work of this contract, the following tasks were undertaken and completed during the course of the contract: (1) Participation in the design and development of the 14-channel Ames Airborne Tracking Sunphotometer (AATS-14), including the development and implementation of Visual Basic software for real-time data processing and display and post-acquisition data reduction and analysis. (2) Operation of the six-channel Ames Airborne Tracking Sunphotometer (AATS-6) aboard the University of Washington C-131A during TARFOX and in-field analysis and presentation of data acquired with the AATS-6. (3) Post-mission analysis of data acquired during TARFOX with the AATS-6 and the AATS-14. (4) Pre-TARFOX calibration of the AATS-6 at Mauna Loa Observatory in May 1996, and post-TARFOX calibration of the AATS-6 and AATS- 14 at Zugspitze, Germany in October 1996, including analyses of all data sets. (5) Analysis of AATS-14 airborne calibration data acquired on 17 November 1996 during a late afternoon Pelican flight over the central California coast. (6) Operational training, instrument preparation, field coordination, and analysis of shipboard measurements of aerosol optical depth with the AATS-6 during ACE-2. (7) Coordination of data acquisition with the AATS-14 aboard the Pelican during ACE-2 and in-field preliminary data analysis and presentation. (8) Calibration of the AATS-6 and AATS-14 in April/May 1997 at Mauna Loa prior to ACE-2, and post-mission calibration of the AATS-6 at Mauna Loa in August 1997.

Livingston, John M.↗