Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

JPL Fourier transform ultraviolet spectrometer

The Fourier Transform Ultraviolet Spectrometer (FTUVS) is a new high resolution interferometric spectrometer for multiple-species detection in the UV, visible and near-IR. As an OH sensor, measurements can be carried out by remote sensing (limb emission and column absorption), or in-situ sensing (long-path absorption or laser-induced fluorescence). As a high resolution detector in a high repetition rate (greater than 10 kHz) LIF system, OH fluorescence can be discriminated against non-resonant background emission and laser scatter, permitting (0, 0) excitation.

Cageao, R. P.↗

Local fluctuations of ozone from 16 km to 45 km deduced from in situ vertical ozone profile

A vertical ozone profile obtained by an in situ ozone sonde from 16 km to 45 km, has allowed to observe local ozone concentration variations. These variations can be observed, thanks to a fast measurement system based on a UV absorption KrF excimer laser beam in a multipass cell. Ozone standard deviation versus altitude calculated from the mean is derived. Ozone variations or fluctuations are correlated with the different dynamic zones of the stratosphere.

Moreau, G.↗

Soot Optical Property Study

Recent past studies of soot reaction processes in laminar premixed and nonpremixed flames generally have used the intrusive technique of thermophoretic sampling and analysis by transmission electron microscopy (TEM) to observe soot structure and obtain important fundamental information about soot particle properties, such as soot primary particle diameters, the rate of change of soot primary particle diameter as a function of time (or rate of soot surface growth or oxidation), the amount of soot particle reactive surface area per unit volume, the number of primary soot particles per unit volume, and the rate of formation of primary soot particles (or the rate of soot primary particle nucleation). Given the soot volume per unit volume of the flame (or the soot volume fraction), all these properties are readily found from a measurement of the soot primary particle diameter (which usually is nearly a constant for each location within a laminar flame). This approach is not possible within freely propagating flames, however, because soot properties at given positions in such flames vary relatively rapidly as a function of time in the soot formation and oxidation regions compared to the relatively lengthy sampling times needed to accumulate adequate soot samples and to minimize effects of soot collected on the sampling grid as it moves to and from the sampling position through other portions of the flame. Thus, nonintrusive optical methods must be used to find the soot primary particle diameters needed to define the soot surface reaction properties mentioned earlier. Unfortunately, approximate nonintrusive methods used during early studies of soot reaction properties in flames, found from laser scattering and absorption measurements analyzed assuming either Rayleigh scattering or Mie scattering from polydisperse effective soot particles having the same mass of soot as individual soot aggregates, have not been found to be an effective way to estimate the soot surface reaction area per unit volume. Thus, alternative nonintrusive optical methods of finding these properties must be sought, which was the objective of this phase of the investigation. The alternative method used here involves use of the Rayleigh-Debye-Gans-Polydisperse-Fractal-Aggregate (RDG-PFA) scattering approximation for soot aggregates in flames. Thus, the development of this method will be discussed next before describing its evaluation as a means of nonintrusively measuring soot primary particle diameters in soot-containing flames.

Aung, K. T.↗

Aircraft(ER-2) and Balloon In-Situ Measurements of HC1, NO(sub 2), HNO(sub 3), N(sub 2)o, and CH(sub 4) for Testing Heterogeneous Chemistry on PSC's and Sulfate Aerosols in the 1991/92 Arctic Winter

Concentrations of HC1 measured in the 1991/3 northern hemisphere lower stratosphere from the ER-2 aircraft are significantly lower than model predictions using both gas phase and heterogeneous chemistry, but are in much better agreement with model predictions for the 1994 southern hemisphere.

In-Situ Sensor (BLISS)↗

Application of STARFLEET Velocimetry in the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel

Selective two-photon absorptive resonance femtosecond laser electronic excitation tagging (STARFLEET) velocimetry is demonstrated for the first time in a NASA Langley wind tunnel with high repetition-rate and single-shot imaging. Experiments performed in the 0.3-meter Transonic Cryogenic Tunnel (TCT) allowed for testing at 300 K over a range of pressures (124 to 517 kPa) and Mach numbers (0.2-0.8) for freestream conditions and flow behind a cylindrical model. Measurement precision and accuracy are determined for the current set of experiments, as are signal intensity and lifetime. Precisions of 3-5 m/s (based on one standard deviation) were typical in the experiment; precisions better than 2% of the mean velocity were obtained for some of the highest velocity conditions. Agreement within a mean error of 3 m/s between STARFLEET freestream velocity measurements and facility DAS readings is demonstrated. STARFLEET is also shown to return spatially-resolved velocity profiles, though some binning of the signal is required.

STARFLEET↗

Method of and apparatus for measuring temperature and pressure

Laser beams are transmitted through gas to a reflecting target, which may be either a solid surface or particulate matter in gas or the gas molecules. The return beams are measured to determine the amount of energy absorbed by the gas. For temperature measurements, the laser beam has a wavelength at which the gas exhibits a relatively temperature sensitive and pressure insensitive absorption characteristic for pressure measurements, the laser beam has a wavelength at which the gas has a relatively pressure sensitive and temperature insensitive absorption characteristic. To reduce the effects of scattering on the absorption measurements a reference laser beam with a weak absorption characteristic is transmitted colinearly with the data beam having a strong absorption characteristic. The two signals are processed as a ratio to eliminate back scattering. Embodiments of transmitters and receivers described include a sequential laser pulse transmitter and receiver, a simultaneous laser pulse transmitter and receiver.

Korb, C. L.↗

Compact Laser-Based Sensors for Monitoring and Control of Gas Turbine Combustors

Research is reported on the development of sensors for gas turbine combustor applications that measure real-time gas temperature using near-infrared water vapor absorption and concentration in the combustor exhaust of trace quantities of pollutant NO and CO using mid-infrared absorption. Gas temperature is extracted from the relative absorption strength of two near-infrared transitions of water vapor. From a survey of the water vapor absorption spectrum, two overtone transitions near 1800 nm were selected that can be rapidly scanned in wavelength by injection current tuning a single DFB diode laser. From the ratio of the absorbances on these selected transitions, a path-integrated gas temperature can be extracted in near-real time. Demonstration measurements with this new temperature sensor showed that combustor instabilities could be identified in the power spectrum of the temperature versus time record. These results suggest that this strategy is extremely promising for gas turbine combustor control applications. Measurements of the concentration of NO and CO in the combustor exhaust are demonstrated with mid-infrared transitions using thermo-electrically cooled, quantum cascade lasers operating near 5.26 and 4.62 microns respectively. Measurements of NO are performed in an insulated exhaust duct of a C2H4-air flame at temperatures of approximately 600 K. CO measurements are performed above a rich H2-air flame seeded with CO2 and cooled with excess N2 to 1150 K. Using a balanced ratiometric detection technique a sensitivity of 0.36 ppm-m was achieved for NO and 0.21 ppm-m for CO. Comparisons between measured and predicted water-vapor and CO2 interference are discussed. The mid-infrared laser quantum cascade laser technology is in its infancy; however, these measurements demonstrate the potential for pollutant monitoring in exhaust gases with mid-IR laser absorption.

Hanson, Ronald K.↗

Development in tunable solid state lasers with high spectral purity, high efficiency and long lifetime for differential absorption lidar

The paper presents a review of tunable vibronic solid state lasers for DIAL measurements and provides new experimental results for tunable Ti:sapphire lasers, materials development, and spectral bandwidth narrowing through injection control. Pulsed injection control of a Ti:sapphire laser with a 2.5-pm narrow band pulsed dye laser and with another Ti:sapphire laser is demonstrated with nearly complete energy extraction, indicating homogeneous line broadening. The status of tunable solid state lasers in the 1.6-2.3 micron range for DIAL measurements of trace gases, and development trends for lasers with reduced cryogenic cooling needs, are included. The effects of laser gain on optical damage, energy extraction, and amplified spontaneous emission are indicated for several tunable lasers.

Hess, R. V.↗

A Comparison of NO Laser-Induced Fluorescence Models at Conditions Relevant to Supersonic and Hypersonic Flows

Planar laser-induced fluorescence (PLIF) of the nitric oxide (NO) molecule has been widely used in wind tunnel facilities for flow visualization, velocity, and temperature measurements. The experimental PLIF measurements are often compared with synthetic PLIF images using computationally derived temperatures, pressures, velocities, and species mole fractions. This approach is commonly referred to as computational flow imaging (CFI). In the present work, we compare signal intensity from PLIF models with experimental PLIF measurements obtained within a low pressure gas cell system at pressures and NO mole fractions relevant to supersonic and hypersonic flowfields. Experimental measurements were compared to several different laser induced-fluorescence models reported in the literature including LIFBASE, LINUS, and a NASA two-level model. The experimental measurements agreed well with all of the models at lower pressures and lower NO mole fractions; the fluorescence there is linear with both of these parameters. However, at higher pressures and mole fractions, the signal becomes nonlinear with respect to these parameters as self-quenching limits the signal and absorption further limits the signal. In fact, for the experimental path length of the experiment, the combination of high pressure and high NO mole fraction causes the experimental results to deviate significantly from the predicted results that neglect absorption of the incident laser sheet. The LINUS model, which allows absorption to be calculated, provided results that agreed better with the experimental measurements. Since supersonic and hypersonic flowfields may contain a region of the flow with high pressures and measurements in large-scale facilities often include a long path length, neglecting absorption may have a significantly negative effect on the CFI comparison to experimental PLIF images. As a result, PLIF models that account for absorption should be included in computational flow imaging approaches for laser induced fluorescence.

laser-induced fluorescence↗

Laser flash photolysis studies of atmospheric free radical chemistry using optical diagnostic techniques

Some recent studies carried out in our laboratory are described where laser flash photolytic production of reactant free radicals has been combined with reactant and/or product detection using time-resolved optical techniques to investigate the kinetics and mechanisms of important atmospheric chemical reactions. Discussed are (1) a study of the radical-radical reaction O + BrO yields Br + O2 where two photolysis lasers are employed to prepare the reaction mixture and where the reactants O and BrO are monitored simultaneously using atomic resonance fluorescence to detect O and multipass UV absorption to detect BrO; (2) a study of the reaction of atomic chlorine with dimethylsulfide (CH3SCH3) where atomic resonance fluorescence detection of Cl is employed to elucidate the kinetics and tunable diode laser absorption spectroscopy is employed to investigate the HCl product yield; and (3) a study of the aqueous phase chemistry of Cl2(-) radicals where longpath UV absorption spectroscopy is employed to investigate the kinetics of the Cl2(-) + H2O reaction.

Wine, Paul H.↗

Saturated absorption in NH3 demonstrated using a tuneable diode laser

Saturation of molecular transitions using a tunable diode laser has been demonstrated for the first time using a standing-wave-cavity configuration with the laser beam focused at the sample. Observed saturation effects in NH3 transitions near 888 kaysers include sub-Doppler (Lamb-dip) resonances at the line center.

Jennings, D. E.↗

A High Spectral Resolution Lidar Based on Absorption Filter

A High Spectral Resolution Lidar (HSRL) that uses an iodine absorption filter and a tunable, narrow bandwidth Nd:YAG laser is demonstrated. The iodine absorption filter provides better performance than the Fabry-Perot etalon that it replaces. This study presents an instrument design that can be used a the basis for a design of a simple and robust lidar for the measurement of the optical properties of the atmosphere. The HSRL provides calibrated measurements of the optical properties of the atmospheric aerosols. These observations include measurements of aerosol backscatter cross sections, optical depth, backscatter phase function depolarization, and multiple scattering. The errors in the HSRL data are discussed and the effects of different errors on the measured optical parameters are shown.

Piironen, Paivi↗

Recent Development of Component Technologies for 2 micrometer LIDAR at JPL

Objective::Global-scale atmospheric measurements of Carbon Dioxide (CO2) and other Green House Gases with full diurnal, full latitude, all season coverage capability. Implementation: Use of the laser- based Integrated Path Differential Absorption (IPDA) method at 1.57 and 2.05 microns. Airborne lasers are needed to demonstrate instrument capabilities, risk reduction and satellite measurement validation.

detector↗

Atmospheric solar absorption measurements in the 9-11 micron region using a diode laser heterodyne spectrometer

A tunable diode laser heterodyne radiometer was developed for ground based measurements of atmospheric solar absorption spectra in the 9 to 12 micron spectral range. The performance and operating characteristics of this tunable infrared heterodyne radiometer (TIHR) is discussed along with recently measured heterodyne solar absorption spectra in the 10 to 11 micron spectral region.

Harward, C. N.↗

Water vapor absorption coefficients in the 8-13-micron spectral region - A critical review

Measurements of water vapor absorption coefficients in the thermal IR atmospheric window (8-13 microns) during the past 20 years obtained by a variety of techniques are reviewed for consistency and compared with computed values based on the AFGL spectral data tapes. The methods of data collection considered were atmospheric long path absorption with a CO2 laser or a broadband source and filters, a White cell and a CO2 laser or a broadband source and a spectrometer, and a spectrophone with a CO2 laser. Advantages and disadvantages of each measurement approach are given as a guide to further research. Continuum absorption has apparently been measured accurately to about the 5-10 percent level in five of the measurements reported.

Grant, William B.↗

Detection of nitric oxide pollution

Studies of absorption spectra enhancement of certain atomic and molecular species inserter in dye-laser cavities have indicated that nitric oxide can be determined at low concentrations. Absorption coefficient of small amounts of nitric oxide in intra-laser-cavity absorption cell containing helium is enhanced by more than two orders of magnitude.

Chackerian, C., Jr.↗

Instantaneous flow measurements in a supersonic wind tunnel using spectrally resolved Rayleigh scattering

Results of a feasibility study to apply laser Rayleigh scattering to non-intrusively measure flow properties in a small supersonic wind tunnel are presented. The technique uses an injection seeded, frequency doubled Nd:YAG laser tuned to an absorption band of iodine. The molecular Rayleigh scattered light is filtered with an iodine cell to block light at the laser frequency. The Doppler-shifted Rayleigh scattered light that passes through the iodine cell is analyzed with a planar mirror Fabry-Perot interferometer used in a static imaging mode. An intensified CCD camera is used to record the images. The images are analyzed at several subregions, where the flow velocity is determined. Each image is obtained with a single laser pulse, giving instantaneous measurements.

Seasholtz, Richard G.↗