Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Multiple fiberoptic probe for several sensing applications

A multiple fiber-optic particle sizing probe which uses a linear array of 11 optical fibers positioned in the focal plane of a graded index microlens is presented. The probe, a compact optical spectrum analyzer, provides simultaneous filtering of the angular spectrum of an extended quasi-monochromatic source. Active and passive configurations provide accurate measurements of the particle size distributions. The multiple fiber-optic probe together with processing electronics is a particle sizing sensor which yields the size distribution within 1-2 min.

Dhadwal, Harbans S.↗

Noble gas evidence of an aqueous reservoir near the surface of Mars more recently than 1.3 Ga

Considerable evidence points to a Martian origin of the SNC meteorites. One of these meteorites, Nakhla, contains a leachable component which has an elevated Xe-129/Xe-132 ratio relative to its Kr-84/Xe-132 ratio when compared to the approximately linear array defined by Chassigny, most shergottites, and lithology C of EETA 79001. This array is thought to be a mixing line between Martian mantle and Martian atmosphere. The leachable component probably consists in part of iddingsite, an alteration product produced by interaction of olivine with aqueous fluid at temperatures lower than 150 C. The radiogenic Xe component may represent a distinct reservoir in the Martian crust or mantle. More plausibly, it is Martian atmosphere, fractionated by solution in liquid water and by interaction with sediment. The crystallization age of Nakhla is 1.3 Ga. Its low shock state suggests that it was ejected from near the surface of Mars. Liquid water is required for the formation of iddingsite. These observations provide further evidence for the near surface existence of aqueous fluids more recently than 1.3 Ga.

Drake, Michael J.↗

Physical interpretation and development of ultrasonic nondestructive evaluation techniques applied to the quantitative characterization of textile composite materials

In this Progress Report, we describe our current research activities concerning the development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the characterization of stitched composite materials and bonded aluminum plate specimens. One purpose of this investigation is to identify and characterize specific features of polar backscatter interrogation which enhance the ability of ultrasound to detect flaws in a stitched composite laminate. Another focus is to explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize bonded aluminum lap joints. As an approach to implementing quantitative ultrasonic inspection methods to both of these materials, we focus on the physics that underlies the detection of flaws in such materials.

Miller, James G.↗

On possible Mn-53 heterogeneity in the early solar system

The effects of influence of shock wave propagation on the energy spectrum of accelerated particles that lead to different production rates of radionuclides, in particular, Mn-53, on small scales in the early solar system are shown. Search for evidence for extinct Mn-53 has stimulated investigations of Cr isotope anomalies in meteorites. The linear correlation between the magnitude of the Cr-53* excesses and the Mn/Cr ratio that unambiguously proves the in situ decay of Mn-53 was detected, really, in different mineral phases of some carbonaceous and enstatite chondrites, primitive achondrites, pallasites and iron meteorites. However, the data on the Cr-53* excess rarely defines a single linear array on a Mn-53-Cr-52 evolution diagram even for meteorites of the same chemical group. A clear isochron with Mn-53/Mn-55 = 4.4 plus or minus 1.0 x 10(exp -5) (in range of approximately 2.4 to approximately 9 x 10(exp -5)) is observed for CAI of the Allende C3-chondrite while the data for the Murchison C2- and Orgueil C1-chondrites fall much lower corresponding rather to Mn-53/Mn-55 less than 2 x 10(exp -5). In the case of iron meteorites it ranges from less than 5 x 10(exp -8) to less than 5 x 10(exp -5).

Lavrukhina, A. K.↗

Remote sounding of tropospheric minor constituents

The etalon interferometer, or Fabry-Perot interferometer (FPI), with its high throughput and high spectral resolution was widely used in the remote-sensing measurements of the earth's atmospheric composition, winds, and temperatures. The most recent satellite instruments include the Fabry-Perot interferometer flown on the Dynamics Explorer-2 (DE-2) and the High Resolution Doppler Imager (HRDI) to be flown on the Upper Atmosphere Research Satellite (UARS). These instruments measure the Doppler line profiles of the emission and absorption of certain atmospheric species (such as atomic oxygen) in the visible spectral region. The successful space flight of DE-FPI and the test and delivery of UARS-HRDI demonstrated the extremely high spectral resolution and ruggedness of the etalon system for the remote sensing of earth and planetary atmospheres. Recently, an innovative FPI focal plane detection technique called the Circle-to-Line Interferometer Optical (CLIO) system was invented at the Space Physics Research Laboratory (SPRL). The CLIO simplifies the FPI focal plane detection process by converting the circular rings or fringes into a linear pattern similar to that produced by a conventional spectrometer, while retaining the throughput advantage of the etalon interferometer. CLIO makes the use of linear array detectors more practical and efficient with FPI, the combination of FPI and CLIO represents a very promising new technique for the remote sensing of the lower atmospheres of Earth, Mars, Venus, Neptune, and other planets. The Multiorder Etalon Spectrometer (MOES), as a combination of the rugged etalon and the CLIO, compares very favorably to other spaceborne optical instruments in terms of performance versus complexity. The feasibility of an advanced etalon spectrometer for the remote sensing of tropospheric trace species, particularly carbon monoxide (CO), nitrous oxide (N2O), and methane (CH4) was discussed. The etalon atmospheric spectroscopy techniques are described, instrument design and related technical issues are discussed. The primary objective is to establish the concept of atmospheric spectroscopy with the CLIO and etalon system and its applications for the measurements of tropospheric trace species analyze system requirements and performance, determine the feasibility of components and subsystem implementation with available technology, and develop inversion algorithm for retrieval simulation and data analysis.

Drayson, S. Roland↗

Enhanced mixing of multiple supersonic rectangular jets by synchronized screech

The objective of the present work is to study the mixing characteristics of a linear array of supersonic rectangular jets under conditions of screech synchronization. The screech synchronization at a fully expanded jet Mach number of 1.61 is achieved by a precise adjustment of the internozzle spacing. To our knowledge, such an experiment on the resonant mixing of screech synchronized multiple rectangular jets has not been reported before. The results are compared with the case where the screech was suppressed in the multijet configuration.

Taghavi, R.↗

Cheap, Easy-To-Read Frequency Monitor For Pulsed Laser

Electronic circuit provides bar-graph display of difference between carrier frequency of pulsed laser transmitter and frequency of another laser serving as local oscillator in receiver. Display device linear array of light-emitting diodes (LED's), each representing 1-MHz portion of beat-frequency range from 20 to 40 MHz. Middle LED and neighbors green; LED's representing edges of passband yellow; LED's of frequencies outside passband red. Operator determines approximate relative frequency of transmitter at a glance by observing color and position of illuminated LED.

Esporoles, Carlos↗

Optoelectronic Inclinometer

Proposed optoelectronic instrument measures tilt of object about single horizontal axis by measuring change of position and orientation of laser beam reflected from hanging mirror. Mirror remains vertical while rest of instrument rotated with object. Optoelectronic inclinometer measures tilt about gimbal axis by measuring change in position and orientation of beam of light reflected from mirror hanging in gimbal. Maximum amount of tilt about pivot axis of pendulum that instrument tolerates depends on size of mirror and physical size of linear array and spacing of components. Compensating lens included to correct for nonlinearity and to ensure that beam continued to fall on array throughout desired angular range of instrument.

Schott, Timothy D.↗

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.↗

Comparison of Angle of Attack Measurements for Wind Tunnel Testing

Two optical systems capable of measuring model attitude and deformation were compared to inertial devices employed to acquire wind tunnel model angle of attack measurements during the sting mounted full span 30% geometric scale flexible configuration of the Northrop Grumman Unmanned Combat Air Vehicle (UCAV) installed in the NASA Langley Transonic Dynamics Tunnel (TDT). The overall purpose of the test at TDT was to evaluate smart materials and structures adaptive wing technology. The optical techniques that were compared to inertial devices employed to measure angle of attack for this test were: (1) an Optotrak (registered) system, an optical system consisting of two sensors, each containing a pair of orthogonally oriented linear arrays to compute spatial positions of a set of active markers; and (2) Video Model Deformation (VMD) system, providing a single view of passive targets using a constrained photogrammetric solution whose primary function was to measure wing and control surface deformations. The Optotrak system was installed for this test for the first time at TDT in order to assess the usefulness of the system for future static and dynamic deformation measurements.

Jones, Thomas, W.↗

Chondrules in the LEW85332 Ungrouped Carbonaceous Chondrite: Fractionation Processes in the Solar Nebula

We studied 14 chondrules separated from LEW85332, an ungrouped type-3 carbonaceous chondrite related to CR chondrites; 23 elements were determined by neutron activation and the chondrules were characterized petrographically. Oxygen isotopic compositions were determined by R. N. Clayton and T. K. Mayeda for seven chondrules. Chondrule abundance ratios tend to form one of two distinct patterns. In low FeO chondrules, refractory lithophile patterns are flat (i.e., unfractionated); siderophile abundances are high and show a small decrease with increasing volatility. Although high FeO chondrules also have flat refractory lithophile abundance patterns, siderophile abundances are highly fractionated; refractory Ir is very low and Fe is very high relative to other siderophiles. We suggest that the low FeO chondrules in LEW85332 formed early in nebular history when metal was intimately mixed with silicates in the chondrule precursors, and that the viscosity of the liquid-solid mix was too high to permit expulsion of the metal by centrifugal action; their porphyritic structures are consistent with incomplete melting, which would result in relatively high viscosities. When the high FeO chondrules formed somewhat later, much of the Fe was oxidized and the melting of precursors was more extensive, FeO and other oxidized siderophiles were retained in the silicate liquid, and metal was lost, possibly expelled from low viscosity chondrule melts. The O isotopic compositions of the chondrules form a linear array of slope 0.93 +/- 0.05 on a three-isotope diagram, parallel to the carbonaceous chondrite anhydrous minerals (CCAM) line and a CR chondrule array, but offset from the latter by -1% in (delta)O-18. Some or all of this offset may reflect incorporation of O from Antarctic water during weathering. Chondrule (Delta)O-17 values correlate positively with FeO, possibly indicating that the (Delta)O-17 of the nebular gas composition increased with time. The chemical and O isotopic data suggest a temporal sequence extending from early, low FeO to late high FeO chondrules.

Wasson, John T.↗

Estimating the Single-Trial Characteristics of Event-Related Responses: Evaluation of the MCERP Algorithm

Single-trial event-related responses collected during the course of an experiment are typically averaged before analysis resulting in a rather crude picture of event-related brain dynamics. It has been quite clear for some time that these responses exhibit trial-to-trial variability: however, the computational techniques necessary to deal with such responses in noisy conditions have not been available. To this end we have developed the multiple-component, event-related potential model (mcERP), which assumes that the each event-related response consists of a sum of multiple evoked components each described by a stereotypical waveshape. These waveshapes are allowed to vary in amplitude and onset latency from trial to trial, which allows us to capture, to first-order, the trial-dependent variations in event-related brain dynamics. We have constructed many sets of synthetic data designed to simulate intracortical recordings from a 15 channel, linear-array multielectrode implanted acutely in V1 of an awake-behaving macaque undergoing visual stimulation with a red light flash. This synthetic data was used to characterize the performance of the mcERP algorithm. First we quantified the degree to which such trial-to-trial variability aids in the identification of multiple components, and we demonstrate that amplitude variability is a more important factor in component separation than latency variability. Second, we quantified the behavior of the algorithm under two distinct signal-to-noise ratio (SNR) conditions: Gaussian noise independently present in each channel, and highly correlated (1/f distributed), far-field noise presented identically in each channel of the array. The mcERP algorithm was found to be robust to noise accurately identifying all component waveshapes and their associated single-trial characteristics down to SNR levels of -20dB for Gaussian noise and -7dB for 1/f far-field noise. Comparisons of the performance of this algorithm with factor analysis (FA) and independent component analysis (ICA) will be described by Knuth et al. (SFN abstracts, 2002). In addition, the advantages of application of mcERP to real data will be described by Shah et al, (these abstracts, 2002: SFN abstracts, 2002).

Knuth, K. H.↗

Dry Process for Manufacturing Hybridized Boron Fiber/Carbon Fiber Thermoplastic Composite Materials from a Solution Coated Precursor

An apparatus for producing a hybrid boron reinforced polymer matrix composite from precursor tape and a linear array of boron fibers. The boron fibers are applied onto the precursor tapes and the precursor tape processed within a processing component having an impregnation bar assembly. After passing through variable-dimension forming nip-rollers, the precursor tape with the boron fibers becomes a hybrid boron reinforced polymer matrix composite. A driving mechanism is used to pulled the precursor tape through the method and a take-up spool is used to collect the formed hybrid boron reinforced polymer matrix composite.

Harry L Belvin↗

Process of Making Boron-Fiber Reinforced Composite Tape

The invention is an apparatus and method for producing a hybrid boron reinforced polymer matrix composition from powder pre-impregnated fiber tow bundles and a linear array of boron fibers. The boron fibers are applied onto the powder pre-impregnated fiber tow bundles and then are processed within a processing component having an impregnation bar assembly. After passing through variable-dimension forming nip-rollers, the powder pre-impregnated fiber tow bundles with the boron fibers become a hybrid boron reinforced polymer matrix composite tape. A driving mechanism pulls the powder pre-impregnated fiber tow bundles with boron fibers through the processing line of the apparatus and a take-up spool collects the formed hybrid boron-fiber reinforced polymer matrix composite tape.

Patent↗

Coastal Research Imaging Spectrometer

The Coastal Research Imaging Spectrometer (CRIS) is an airborne remote-sensing system designed specifically for research on the physical, chemical, and biological characteristics of coastal waters. The CRIS includes a visible-light hyperspectral imaging subsystem for measuring the color of water, which contains information on the biota, sediment, and nutrient contents of the water. The CRIS also includes an infrared imaging subsystem, which provides information on the temperature of the water. The combination of measurements enables investigation of biological effects of both natural and artificial flows of water from land into the ocean, including diffuse and point-source flows that may contain biological and/or chemical pollutants. Temperature is an important element of such measurements because temperature contrasts can often be used to distinguish among flows from different sources: for example, a sewage outflow could manifest itself in spectral images as a local high-temperature anomaly.anomaly. Both the visible and infrared subsystems scan in "pushbroom" mode: that is, an aircraft carrying the system moves along a ground track, the system is aimed downward, and image data are acquired in acrosstrack linear arrays of pixels. Both subsystems operate at a frame rate of 30 Hz. The infrared and visible-light optics are adjusted so that both subsystems are aimed at the same moving swath, which has across-track angular width of 15. Data from the infrared and visible imaging subsystems are stored in the same file along with aircraft-position data acquired by a Global Positioning System receiver. The combination of the three sets of data is used to construct infrared and hyperspectral maps of scanned areas shown.

Source record↗

Implied alignment: a synapomorphy-based multiple-sequence alignment method and its use in cladogram search

A method to align sequence data based on parsimonious synapomorphy schemes generated by direct optimization (DO; earlier termed optimization alignment) is proposed. DO directly diagnoses sequence data on cladograms without an intervening multiple-alignment step, thereby creating topology-specific, dynamic homology statements. Hence, no multiple-alignment is required to generate cladograms. Unlike general and globally optimal multiple-alignment procedures, the method described here, implied alignment (IA), takes these dynamic homologies and traces them back through a single cladogram, linking the unaligned sequence positions in the terminal taxa via DO transformation series. These "lines of correspondence" link ancestor-descendent states and, when displayed as linearly arrayed columns without hypothetical ancestors, are largely indistinguishable from standard multiple alignment. Since this method is based on synapomorphy, the treatment of certain classes of insertion-deletion (indel) events may be different from that of other alignment procedures. As with all alignment methods, results are dependent on parameter assumptions such as indel cost and transversion:transition ratios. Such an IA could be used as a basis for phylogenetic search, but this would be questionable since the homologies derived from the implied alignment depend on its natal cladogram and any variance, between DO and IA + Search, due to heuristic approach. The utility of this procedure in heuristic cladogram searches using DO and the improvement of heuristic cladogram cost calculations are discussed. c2003 The Willi Hennig Society. Published by Elsevier Science (USA). All rights reserved.

Non-NASA Center↗

Sm-Nd dating of Fig Tree clay minerals of the Barberton greenstone belt, South Africa

Sm-Nd isotopic data from carbonate-derived clay minerals of the 3.22-3.25 Ga Fig Tree Group, Barberton greenstone belt, South Africa, form a linear array corresponding to an age of 3102 +/- 64 Ma, making these minerals the oldest dated clays on Earth. The obtained age is 120-160 m.y. younger than the depositional age determined by zircon geochronology. Nd model ages for the clays range from approximately 3.39 to 3.44 Ga and almost cover the age variation of the Barberton greenstone belt rocks, consistent with independent evidence that the clay minerals are derived from material of the belt. The combined isotopic and mineralogical data provide evidence for a cryptic thermal overprint in the sediments of the belt. However, the highest temperature reached by the samples since the time of clay-mineral formation was <300 degrees C, lower than virtually any known early Archean supracrustal sequence.

Non-NASA Center↗

The Stratospheric Aerosol and Gas Experiment (SAGE III)

Three SAGE III instruments are being built by Ball Aerospace & Technologies Corporation in Boulder, Colorado (USA). SAGE III is a fourth generation instrument that incorporates robust elements of its predecessors [SAM II, SAGE, SAGE II] while incorporating new design elements. The first of these will be launched aboard a Russian Meteor/3M platform in May 1999. SAGE III will add measurements of O2-A band from which density and temperature profiles are retrieved. This feature should improve refraction and Rayleigh computations over earlier. Additionally, the linear array of detectors will permit on-orbit wavelength calibration from observations of the exo-atmospheric solar Fraunhofer spectrum.

Thomason, Larry W.↗