Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Current Developments in Retail Rate Design: Implications for Solar and Other Distributed Energy Resources

Retail electricity pricing is evolving in the context of broader shifts in how electricity customers pay for grid services and how they are compensated for customer-sited generation. This evolution has been prompted by a broad set of factors, chief among them being: widespread adoption of advanced metering infrastructure (AMI), increased customer investment in solar and other distributed energy resources (DERs), concerns about utilities’ fixed cost recovery and revenue sufficiency in an era of flat or declining load growth, and significant changes to utilities’ hourly net load profiles and operational needs as greater amounts of variable renewable energy (VRE) resources connect to the grid. This report discusses five current retail rate design trends among residential and commercial customer classes that have emerged, at least in part, in response to those drivers, and uses case studies to illustrate key motivations, variations in rate design, and aspects of implementation experience.

14 SOLAR ENERGY↗

Flattop-HEU Benchmark Reevaluation Summary

The Flattop critical assembly was first constructed in the 1950’s at Los Alamos National Laboratory as a follow-on to the Topsy experiment. Flattop is composed of a sphere of special nuclear material (SNM) surrounded by a thick spherical reflector made of natural uranium (NU). Two SNM cores currently exist: a highly-enriched-uranium (HEU) core and a plutonium core. The reflector is composed of three parts: a stationary hemisphere and two movable quarter spheres. For fine reactivity control, there are three control rods of NU that are inserted into the stationary hemisphere from underneath the assembly. The final components that allow for reactivity adjustment are the glory hole pieces, mass adjustment buttons, and hemispherical caps. These pieces can be loaded in various configurations to change the available reactivity loaded in the system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Learning-Based Load Control to Support Resilient Networked Microgrid Operations

Microgrids have proven to be an effective option for increasing the resiliency of critical end-use loads during extreme events. Building on past operational experiences, some microgrid operators are examining the potential to network microgrids to further improve resiliency. However, the frequency deviations experienced on isolated microgrids during transient events, such as switching operations, step increases in load, and loss of generation, are significantly larger than those typically seen on bulk transmission systems. The larger frequency deviations can cause a loss of inverter-connected assets, resulting in a loss of power to critical end-use loads. This paper presents a method of mitigating the impact of transient events by engaging end-use loads using Grid-Friendly Appliance TM (GFA) controllers. An online, i.e., real-time, device-level algorithm is presented, which adjusts individual GFA controller frequency set-points based on the operational characteristics of each end-use load, and on the changing grid dynamic characteristics. The presented method improves the dynamic stability of the networked microgrid operations while minimizing the interruptions to end-use loads. The presented work is validated with dynamic simulations using a modified version of the IEEE 123-node test system with three microgrids, using the GridLAB-D TM simulation environment.

Radhakrishnan, Nikitha↗

Weather Sensitive High Spatio-Temporal Resolution Transportation Electric Load Profiles For Multiple Decarbonization Pathways

Electrification of transport compounded with climate change will transform hourly load profiles and their response to weather. We present a novel approach to generating hourly electric load profiles that considers charging strategies and evolving sensitivity to temperature. The approach consists of downscaling annual state-scale sectoral load projections from the multisectoral Global Change Analysis Model (GCAM) into hourly electric load profiles leveraging high resolution climate and population datasets. Profiles are developed and evaluated at the Balancing Authority scale, with a 5-year increment until 2050 over the Western U.S. Interconnect for multiple decarbonization pathways and climate scenarios. The datasets are readily available for production cost model analysis. Our open source approach is transferable to other regions.

Decarbonization, tranportation, Electric vehicle c↗

Damage-induced property changes in composites subjected to cyclic thermal loading

Damage in the form of transverse cracks resulting from thermal loading is studied as it relates to the dimensional stability of flat laminates and stiffness changes in cylindrical tubes. Graphite-epoxy specimens were subjected to cyclic thermal loading in the temperature range -250 to + 250 F. It is shown that transverse cracking is the dominant damage mechanism in both types of structural elements. Fiber splitting is also quite common at the low test temperatures. Experimental results indicate that damage significantly reduces the inplane coefficients of thermal expansion of flat laminates and the torsional stiffness of the tubes. Theoretical predictions for coefficients of thermal expansion as a function of crack spacing in flat laminates followed the same trend as experimental results.

Herakovich, Carl T.↗

The post-pinatubo evolution of stratospheric aerosol surface area density as inferred from SAGE 2

Following the eruption of Mount Pinatubo in June of 1991, the aerosol mass loading of the stratosphere increased from -1 Mt to approximately 30 Mt. This change in aerosol loading was responsible for numerous radiative and chemical changes observed within the stratosphere. As a result, the ability to quantify aerosol properties on a global basis during this period is important. Aerosol surface area density is a critical parameter in governing the rates of heterogeneous reactions, such as ClONO2 plus H2O yields HNO3 plus HOCl, which influence the stratospheric abundance of ozone. Following the eruption of Mt. Pinatubo, measurements by the Stratospheric Aerosol and Gas Experiment (SAGE 2) indicated that the stratospheric aerosol surface area density increased by as much as a factor of 100. Using SAGE 2 multi-wavelength aerosol extinction data, aerosol surface area density as well as mass are derived for the period following the eruption of Mt. Pinatubo through the present.

Poole, L. R.↗

Elimination of Gibbs' phenomena from error analysis of finite element results

This paper is one of a series on error analysis and correction of finite element solutions for plates and shells. The error analysis in the earlier papers used half-range double Fourier sine series for numerical harmonic analysis. The half-range formulas are simple to apply, but they can be inaccurate near the ends of the ranges of the independent variables. The Gibbs' phenomenon exhibited by half-range sine series in one independent variable has a two-dimensional analog; a classic example is the Navier solution in a double half-range sine series for the simply supported plate under a uniform load. A simple change of variables is introduced in the paper to improve the accuracy of the double Fourier sine series without adding complexity to the numerical analysis. The change of variables is applied to the problem of approximating a transverse load that is tabulated on a rectangular grid. A solution based on the change of variables is compared with results from the Navier solution for the simply supported plate problem and finite element results for the same problem.

Thurston, Gaylen A.↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

The Effects of Orbital Spaceflight on Human Osteoblastic Cell Physiology and Gene Expression

The purpose of the proposed study is to establish whether changes in gravitational loading have a direct effect on osteoblasts to regulate TGF-6 expression. The effects of spaceflight and reloading on TGF-B MRNA and peptide levels will be studied in a newly developed line of immortalized human fetal osteoblasts (HFOB) transfected with an SV-40 temperature dependent mutant to generate proliferating, undifferentiated hFOB cells at 33-34 C and a non-proliferating, differentiated HFOB cells at 37-39'C. Unlike previous cell culture models, HFOB cells have unlimited proliferative capacity yet can be precisely regulated to differentiate into mature cells which express mature osteoblast function. If isolated osteoblasts respond to changes in mechanical loading in a manner similar to their response in animals, the cell system could provide a powerful model to investigate the signal transduction pathway for gravitational loading.

Turner, R. T.↗

Temperature Oscillations in Loop Heat Pipe Operation

Loop heat pipes (LHPs) are versatile two-phase heat transfer devices that have gained increasing acceptance for space and terrestrial applications. The operating temperature of an LHP is a function of its operating conditions. The LHP usually reaches a steady operating temperature for a given heat load and sink temperature. The operating temperature will change when the heat load and/or the sink temperature changes, but eventually reaches another steady state in most cases. Under certain conditions, however, the loop operating temperature never really reaches a true steady state, but instead becomes oscillatory. This paper discusses the temperature oscillation phenomenon using test data from a miniature LHP.

Ku, Jentung↗

Aerodynamic Drag Reduction Technologies Testing of Heavy-Duty Vocational Vehicles and a Dry Van Trailer

This study focused on two accepted methods for quantifying the benefit of aerodynamic improvement technologies on vocational vehicles: the coastdown technique, and on-road constant speed fuel economy measurements. Both techniques have their advantages. Coastdown tests are conducted over a wide range in speed and allow the rolling resistance and aerodynamic components of road load force to be separated. This in turn allows for the change in road load and fuel economy to be estimated at any speed, as well as over transient cycles. The on-road fuel economy measurements only supply one lumped result, applicable at the specific test speed, but are a direct measurement of fuel usage and are therefore used in this study as a check on the observed coastdown results. Resulting coefficients were then used to populate a vehicle model and simulate expected annual fuel savings over real-world vocational drive cycles.

30 DIRECT ENERGY CONVERSION↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Loads environment for payload/cargo integration

Space Shuttle users are required to design their payload to the Shuttle loads environment. This loads environment covers mission phases from prelaunch to landing. Transient response loads analyses are required for lift-off and landing events. Other mission events are analyzed statically because they result in payload loads that either change slowly or are lower than lift-off and landing loads. Response data from flight instrumentation located on the orbiter and payloads have been compared to preflight design conditions and to nominal predictions. The results have verified that the design loads envelop flight responses.

Frederick, D. H.↗

Evaluation of Load Analysis Methods for NASAs GIII Adaptive Compliant Trailing Edge Project

The Air Force Research Laboratory (AFRL), NASA Armstrong Flight Research Center (AFRC), and FlexSys Inc. (Ann Arbor, Michigan) have collaborated to flight test the Adaptive Compliant Trailing Edge (ACTE) flaps. These flaps were installed on a Gulfstream Aerospace Corporation (GAC) GIII aircraft and tested at AFRC at various deflection angles over a range of flight conditions. External aerodynamic and inertial load analyses were conducted with the intention to ensure that the change in wing loads due to the deployed ACTE flap did not overload the existing baseline GIII wing box structure. The objective of this paper was to substantiate the analysis tools used for predicting wing loads at AFRC. Computational fluid dynamics (CFD) models and distributed mass inertial models were developed for predicting the loads on the wing. The analysis tools included TRANAIR (full potential) and CMARC (panel) models. Aerodynamic pressure data from the analysis codes were validated against static pressure port data collected in-flight. Combined results from the CFD predictions and the inertial load analysis were used to predict the normal force, bending moment, and torque loads on the wing. Wing loads obtained from calibrated strain gages installed on the wing were used for substantiation of the load prediction tools. The load predictions exhibited good agreement compared to the flight load results obtained from calibrated strain gage measurements.

Aerodynamic Loads↗

Modeling the Radiative Characteristics of Airborne Mineral Aerosols at Infrared Wavelengths

We explore the importance of the composition of airborne mineral aerosols for assessments of their direct radiative forcing at infrared wavelengths. Our calculations employing theory and data on spectral refractive indices show that the existing variations in refractive places can cause large changes in the major aerosol optical characteristics. Calculations of IR radiative forcings at the top of the atmosphere and IR downward and upward fluxes, based on an one-dimensional radiation transfer code, give a wide range of results for varying optical models of the mineral aerosols. We estimate that for a "low dust loading" scenario the changes in IR downward flux at the surface relative to dust free conditions are in the range from 7 to 14 W/sq m depending upon the mineral aerosol selected. Under "dry tropics" atmospheric conditions the IR forcing at the top of the atmosphere is in the range from 2 to 7 W/sq m. In turn, for a "high dust loading" scenario the calculated changes, relative to dust free conditions, in IR downward flux at the surface vary from 50 to 80 W/sq m , and the IR forcing at the top of the atmosphere varies from 125 W/sq m. Therefore, we conclude that incorporation of regionally and temporally varying dust mineralogical composition into general circulation models could be beneficial for decreasing the currently large uncertainties in the assessment of radiative forcing by the natural and anthropogenic components of the airborne mineral aerosols. Also the use of appropriate mineralogical data is required for remote sensing of the atmospheric aerosols using satellite infrared observations.

Sokolik, Irina N.↗

Reviewing Flexibility in Industrial Electrification: U.S. Green Ammonia and Steel Industries [Slides]

The renewable energy transition in the power sector involves a paradigm shift for flexibility. Supply flexibility faces new constraints due to the increased share of variable renewable resources. Increased demand flexibility can allow less use of peaking power plants and delay need for additional capacity and transmission. Industrial customers are larger on average than residential and commercial consumers and have typically provided the largest share of demand response in the United States. We consider industrial demand, studying characteristics of flexible industrial loads. We examine the dynamics of change occurring around industrial load flexibility by focusing on two case studies: green ammonia and steel production via electric arc furnaces. Electric arc furnace steel production is an important component of current demand response programs, whereas green ammonia and green fuels offer new paradigms for flexibility. We analyze the structure and functions of the technological innovation systems of load flexibility in those two industries via interviews with twenty-two stakeholders. We conclude that the technological innovation systems are not well-functioning for flexibility in EAF based steelmaking, but are in the green ammonia space. Explicit connections between scope two greenhouse gas emissions reporting and flexibility are lacking, and industry stakeholders do not appear to make a connection between decarbonization and load flexibility.

25 ENERGY STORAGE↗

Limits on the Range and Rate of Change in Power Take-Off Load in Ocean Wave Energy Conversion: A Study Using Model Predictive Control

Previous work comparing power take-off (PTO) architectures for ocean wave-powered reverse osmosis suggests that variable displacement in the wave energy converter (WEC)-driven pump does not offer a significant performance advantage. A limitation of that study is that the WEC was subject to a constant load within a given sea state (“Coulomb damping”) and did not account for controlled, moment-to-moment variation of the PTO load enabled by a variable displacement pump. This study explores the potential performance advantage of a variable PTO load over Coulomb damping. Model predictive control is used to provide optimal load control with constraints on the PTO load. The constraints include minimum and maximum loads and a limit on the rate of load adjustment. Parameter studies on these constraints enable conclusions about PTO design requirements in addition to providing an estimated performance advantage over Coulomb damping. Numerical simulation of the Oyster 1 WEC is carried out with performance weighted by historical sea state data from Humboldt Bay, CA. The results show a performance advantage of up to 20% higher yearly-average power absorption over Coulomb damping. Additionally, the parameter studies suggest that the PTO load should be adjustable down to at least 25% of the maximum load and should be adjustable between the minimum and maximum loads within a few seconds.

16 TIDAL AND WAVE POWER↗

Flight investigation of the response of a helicopter to the trailing vortex of a fixed-wing aircraft

A flight investigation was conducted to quantitatively determine the response of a medium-weight helicopter to the trailing-vortex system of a fixed-wing aircraft. Flight tests and analytical tools were both utilized in the investigation. The flight tests involved an extensively instrumented UH-1H helicopter and a C-54 aircraft. Penetrations of the vortex system by the UH-1H were made at the following nominal conditions: the C-54 flew at 5500 feet altitude at a nominal gross weight of 58,000 pounds and an indicated airspeed of 115 knots in a cruise configuration. The UH-1H, nominally 7200 pounds gross weight, flew at 60 knots indicated airspeed during the penetrations at separation distances of 6.64 nautical miles to 0.42 nautical mile between aircraft. In general, the data analyzed for the above tests indicated that no unsafe penetration occurred. Further, penetrating vehicle attitude changes and structural loads were nominal. In addition, the response of the helicopter did not change appreciably with decreased separation distance.

Mantay, W. R.↗