Advanced Photovoltaic Inverter Functionality Verification using 500 kW Power Hardware-in-Loop Complete System Laboratory Testing
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation during perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and, in some cases, return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation during perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential.
The existing Hanford Tank Farms Waste Transfer System has several models of ball valves used for double valve isolation (DVI) that have been installed for 10 or more years. The safety function of the safety-significant valves is to limit leakage of waste past the valves in order to decrease the consequences of a fine spray release due to a transfer misroute. While previous leak testing of the valves has been conducted, the testing did not address concerns in the Documented Safety Analysis concerns about the impact on valve operation and service life of the potential abrasive/erosive properties of the tank waste on the valves when cycled. Pacific Northwest National Laboratory (PNNL) conducted DVI tests at their Multi-Phase Transport Evaluation Loop Facility. Testing evaluated the leak rate of safety-significant isolation valves for DVI as a function of simulated operating cycles. PNNL developed a performance-based simulant specifically for this test program. The test environment simulated the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during single-shell tank retrieval and waste feed delivery to the Hanford Tank Waste Treatment and Immobilization Plant. The testing consisted of periodically measuring leak rates and maximum operational torques on the DVI valves after prescribed numbers of valve operational cycles (open and close). The test results from the simulant cycle tests provide Washington River Protection Solutions with performance characteristics that can be used to verify compliance with the Documented Safety Analysis limits for valve seat leakage. (authors)
High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.
Phase 3 of this project uses the knowledge and techniques gained from Phase 1 and Phase 2. The first outcome of Phase 3 is a new test section which can be manufactured and tested in the Helium Flow Loop Experiment to verify the results of the optimization study. The second outcome of Phase 3 is analyzing the features of this design and determining its performance under simulated TBM conditions: heat flux, pressure, mass flow rate, one-sided and volumetric heating. This will be accomplished by first using the results from the Phase 1 analyses and then applying the optimization strategy from Phase This phase uses the STAR-CCM+ Design Manager tool to apply the optimization strategy to the Helium Flow Loop Experiment (HFLE). The optimization algorithm used by the Design Manager tool is Simultaneous Hybrid Exploration that is Robust, Progressive, and Adaptive (SHERPA search algorithm). In addition to demonstrating the optimization features, a simple parameter sweep is also included in this phase. This report details the applied single objective optimization.
This report describes power hardware-in-the-loop simulation testing of a 500 kW Satcon photovoltaic inverter, conducted at the Center for Advanced Power Systems at Florida State University from March 12th through March 16th, 2012. Testing was led by a team from the National Renewable Energy Laboratory. The report reviews the results of data captured during the course of testing. The tests were used to demonstrate operation of and gather data from the inverter in a simulated operational environment. Testing demonstrated the ability of the inverter to operate in either a Power Factor Control Mode or a Reactive Power Command Mode, and to respond to real power limits.
A variety of instruments are being developed and qualified to support the Accident Tolerant Fuels (ATF) program and future transient irradiations at the Transient Reactor Test (TREAT) facility at Idaho National Laboratory (INL). The University of New Mexico (UNM) is working with INL to develop capacitance-based void sensors for determining the timing of critical boiling phenomena in static capsule fuel testing and the volume-averaged void fraction in flow-boiling in-pile water loop fuel testing. The static capsule sensor developed at INL is a plate-type configuration, while UNM is utilizing a ring-type capacitance sensor. Each sensor design has been theoretically and experimentally investigated at INL and UNM. Experiments are being performed at INL in an autoclave to investigate the performance of these sensors under representative Pressurized Water Reactor (PWR) conditions in a static capsule. Experiments have been performed at UNM using air-water two-phase flow to determine the sensitivity and time response of the capacitance sensor under a flow boiling configuration. Initial measurements from the capacitance sensor have demonstrated the validity of the concept to enable real-time measurement of void fraction. The next steps include designing the cabling interface with the flow loop at UNM for Reactivity Initiated Accident (RIA) ATF testing at TREAT and further characterization of the measurement response for each sensor under varying conditions by experiments and modeling.
The objective of this work was to support the development of grinding models for titanium metal-matrix composites (MMCs) by investigating possible relationships between their indentation hardness, low-stress belt abrasion, high-stress belt abrasion, and the surface grinding characteristics. Three Ti-based particulate composites were tested and compared with the popular titanium alloy Ti-6Al-4V. The three composites were a Ti-6Al-4V-based MMC with 5% TiB{sub 2} particles, a Ti-6Al-4V MMC with 10% TiC particles, and a Ti-6Al-4V/Ti-7.5%W binary alloy matrix that contained 7.5% TiC particles. Two types of belt abrasion tests were used: (a) a modified ASTM G164 low-stress loop abrasion test, and (b) a higher-stress test developed to quantify the grindability of ceramics. Results were correlated with G-ratios (ratio of stock removed to abrasives consumed) obtained from an instrumented surface grinder. Brinell hardness correlated better with abrasion characteristics than microindentation or scratch hardness. Wear volumes from low-stress and high-stress abrasive belt tests were related by a second-degree polynomial. Grindability numbers correlated with hard particle content but were also matrix-dependent.
The TREAT facility is a unique capability at the Idaho National Laboratory currently being prepared for resumption of nuclear transient testing. TREAT is an air-cooled reactor where the driver core is made up of urania dispersed in graphite blocks and encapsulated in zirconium alloy cans. In addition to the reactor itself, the foundation for TREAT's capabilities will also include a suite of irradiation vehicles and supporting infrastructure to provide the desired specimen boundary conditions while supporting a variety of instrumentation needs. Although TREAT historically supported all kinds of nuclear fuels, including LWR's, SFR's, space nuclear propulsion, research reactor plate-type fuels, and even fuels for use in the driver core of other transient test reactors, the majority of TREAT's more-recent experiment programs revolved around SFR's and sodium-environment test capsules and loops. MK-series loop experiment-specific test trains could be outfitted with a variety of instruments to monitor test and specimen conditions while the fast neutron hodoscope collected information about fuel movement before, during, and after transient excursions. The SERTTA (Static Environment Rodlet Transient Test Apparatuses) devices will be general purpose vehicles capable of providing inert gas, water (up to PWR conditions), steam, or perhaps even molten sodium environments within vessel-like capsules. The Multi-SERTTA vehicle design is particularly novel as it makes use of the full active core length in TREAT to test four small rodlets (∼12 cm length), each within its own hermetic boundary, it will be capable of housing pre-irradiated fuel specimens. Additional modules and adaptations of Multi-SERTTA will enable rapid loop pressure blowdown to simulate LOCA conditions. The Super-SERTTA, akin to the Multi-SERTTA will offer more possibilities for simulating transient phenomena.
A feasibility study was conducted to install a 10 MWe coal direct chemical looping large pilot plant at a host site. The coal direct chemical looping technology was based on The Ohio State University and Babcock & Wilcox iron-based metal oxide technology coupling a moving bed reduction reactor with a circulating fluidized-bed oxidation reactor. The host site was the Dover Light & power Plant in Dover, Ohio. The Electric Power Research Institute performed the host site evaluation. Trinity Consultants prepared the Environmental Information Volume. WorleyParsons Group performed the civil engineering. Clear Skies Consulting served as lead on the Industrial Advisory Committee.
A feasibility study was performed to install a 10 MWe coal direct chemical looping steam generation system at the City of Dover Municipal Power Plant in Dover, Ohio. The chemical looping plant utilized Ohio State University's iron-oxide-based metal oxide, and a moving bed reducer coupled with a transport reactor combustor. The Babcock & Wilcox Company developed the component designs and integrated the chemical looping process with the steam cycle. A four-module design was developed which would serve as a prototype arrangement for much larger systems. An environmental study was completed to support the installation of the large pilot plant at the site.
A feasibility study was conducted for installation of a 10 MWe coal direct chemical looping (CDCL) power plant at the City of Dover Municipal Power plant. The CDCL used Ohio State University's iron-oxide based metal oxide and consisted of a moving packed bed reducer coupled with a circulating fluidized bed oxidizer.
This report investigates the tested performance of lower - GWP candidate refrigerant, 94.07 wt% R - 32 + 5.93 wt % R - 134 a mixture (hereafter referred to as R - 32/134a), as an alternative to baseline refrigerant R - 410 A using a 36,000 Btu/hr compressor calorimeter located at the Heat Exchanger Advanced Testing Facility at Oak Ridge National Laboratory . These tests were conducted during May and August 2013. R - 410A is a near - azeotropic blend of R - 32 and R - 125 with 0.5/0.5 mass fraction and has a GWP 100 of 2100. R - 32 and R - 134a are pure refrigerants and have GWP 100 of 716 and 1370 1, respectively. Based on the GWP 100 values of pure refrigerants and their mass fraction in the blend, GWP 100 of R - 32/134a, which is under development by National Refrigerant, is 755. This report compares various performance parameters, such as cooling capacity, compressor power, refrigerant mass flow rate, EER, isentropic efficiency and discharge temperature of the alternative refrigerant to that of R - 410 A.
This presentation covers the interpretations of colloid-homologue tracer test 10-03 conducted at the Grimsel Test Site, Switzerland, in 2010. It also provides a comparison of the interpreted test results with those of tracer test 10-01, which was conducted in the same fracture flow system and using the same tracers than test 10-03, but at a higher extraction flow rate. A method of correcting for apparent uranine degradation in test 10-03 is presented. Conclusions are: (1) Uranine degradation occurred in test 10-03, but not in 10-01; (2) Uranine correction based on apparent degradation rate in injection loop in test 11-02 seems reasonable when applied to data from test 10-03; (3) Colloid breakthrough curves quite similar in the two tests with similar recoveries relative to uranine (after correction); and (4) Much slower apparent desorption of homologues in test 10-03 than in 10-01 (any effect of residual homologues from test 10-01 in test 10-03?).
The NNSA (National Nuclear Security Administration) RERTR (Reduced Enrichment for Research and Test Reactors) program assigned INL (Idaho National Laboratory) the responsibility of developing and demonstrating high uranium density research reactor fuel forms to enable the use of low enriched uranium (LEU) in the research reactors around the world. A series of full-size fuel plate irradiation tests are proposed for the ATR (Advanced Test Reactor). Labeled the AFIP (ATR Full-size-plates In center flux trap Position) experiments, these tests will be conducted in the ATR center flux trap. The AFIP-2 experiment will contain two full size fuel plates fabricated at the Oak Ridge National Laboratory-Y-12 (ORNL). The nominal fuel zone is rectangular in shape having a designed length of 21.5-in (54.6l-cm), width of 1.6-in (4.064-cm), and uniform thickness of 0.014-in (0.03556-cm). This gives a nominal fuel zone volume of 0.482 in3 (7.89 cm3) in each fuel plate. The test holder accommodates two independent test trains. Each test train is designed to hold 2 plates, for a total of 4 plates per test holder. AFIP-2 test plates will be irradiated at a peak surface heat flux of about 350 W/cm2 and discharged at a peak U-235 burn-up of about 70 at.%. Based on limited irradiation testing of the monolithic (U10Mo) fuel form, it is desirable to keep the peak fuel temperature below 250°C; to achieve this, it will be necessary to keep plate heat fluxes below 500 W/cm2. Due to the heavy U-235 loading and width of 1.6-in (4.064 cm), the neutron self-shielding will increase the local-to-average-ratio fission power near the sides of the fuel plates. To assure the AFIP-2 experiment will comply with the ATR safety requirements, a very detailed 2 dimensional (2D) Y-Z fission power profile was evaluated to best predict the fuel plate temperature distribution. The ability to accurately predict fuel plate power and burnup are essential in the AFIP-2 fuel test train design and the irradiated fuel performance evaluation. We obtained the required power and heat generation rates within test train for the thermal analyses. A detailed MCNP Y-Z mini-plate fuel model was developed. The Y-Z model divides each fuel mini-plate into 30 equal intervals in Y and Z directions. The MCNP-calculated results and the detailed Y-Z fission power mapping were used to help design the AFIP-2 fuel test assembly to ensure that the capsule thermal-hydraulic limits will not exceed the ATR safety limit.
Pipelines which carry radioactive waste within the DOE complex should be properly flushed, particularly in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to limit the amount of water used for flushing operations, thus minimizing the consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental pipe loop designed for study of non-Newtonian slurry flushing is currently being developed at the Florida International University (FIU). The testbed is designed to investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. The developed methodologies will be streamlined according to the demands from both Hanford and Savannah River sites. A test matrix containing parameters such as pipeline length, flow rate, and simulant composition (solid concentration, rheology, particle size and density) has been developed. In the initial phase of testing, material composition and loop length will be fixed to a mixture of 17 wt% kaolin in water (to attain density, viscosity, and yield stress in the applicable range to operations at Savannah River and Hanford sites) and 165 feet, respectively. This matrix provides a parametric study on the flush velocity. Prescribed velocities in this test matrix comply with the maximum and minimum recommended flush velocity values by the flushing guidelines for Hanford waste (RPP-RPT-59600, Rev. 0, SRNL-STI-2015-00014, TFC-ENG-STD-26, REV C-1). Efforts will focus on creating repeatable sediment beds inside the pipeline in both fully-flooded and gravity-drained systems. Bed characterization (i.e., measurement of sediment height, solids concentration, and rheology) will be conducted to ensure consistency of initial conditions between tests. A combination of Pulse-Echo technique, Coriolis meter, and optical inspections will be used to accomplish initial bed characterization (ensuring consistency between tests), control/monitor density variations (initial bed creation, flush velocity control, and post-flush evaluations), and serve as reference (validation of PulseEcho and pipe surface cleanness evaluation), respectively. This paper will present the details of the development of the test loop and the test matrix. (authors)
The following report documents the conceptual design for the ATF-2 Ramp experiment. The experiment aims to fill the in-pile irradiation testing gap to conduct integral ramp testing, which was created by the closure of R2, Osiris, and Halden test reactors. The concept involves the simultaneous ramping of three fuel pins using a power axial locator mechanism in the Loop-2A testing facility in the center flux trap of the advanced test reactor (ATR). The three fuel pins are ramped in individual coolant channels containing a prototypic PWR environment. Rod failure will be detected using a fuel rod elongation sensor attached to the fuel pin upper end cap. An axial stack of concentric hafnium and zirconium shrouds will be used to shape the flux around the test pins to create different power levels in each pin and to ensure the peak power location of each pin remains in the center of the test rod. Monte Carlo simulations are used to demonstrate the viability of this design concept.