Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Measurement of Proton, Deuteron, Triton and Alpha Particle Emission after Nuclear Muon Capture on Al, Si and Ti with the AlCap Experiment

Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture of muons stopped in Al, Si, and Ti in the low energy range relevant for the muon-to-electron conversion experiments. Individual charged particle types were identified in layered silicon detector packages and their initial energy distributions were unfolded from the observed energy spectra. Detailed information on yields and energy spectra for all observed nuclei are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Melting temperature measurement of refractory oxide ceramics as a function of oxygen fugacity using containerless methods

An aerodynamic conical nozzle levitator (CNL) has been used to measure the melting temperatures of refractory ceramics. The well-established method of cooling traces has been adapted to allow measurements for air-sensitive samples using a controlled atmosphere, where the oxygen partial pressure can be adjusted and monitored in real time. In this study, we explain the details of a system that we developed for use at the Spallation Neutron Source (Oak Ridge National Laboratory). Measurements of the melting behavior of (Fe,Cr,Al) 3 O 4 spinels were made between log (PO 2 (atm)) of -0.7 and -5. The melting temperature of hercynite is found to be oxygen potential dependent, ranging between 1692 and 1767°C at log (PO 2 ) values from -4.42 to -0.70.

36 MATERIALS SCIENCE↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Capturing soil moisture and salinity changes in flooded coastal forests using electrical resistivity and induced polarization

Geophysical methods provide high-resolution spatial measurements of physical quantities sensitive to changes in soil moisture and salinity and can be used to monitor soil hydrological responses to flooding. However, extracting quantitative hydrological information from geophysical data remains challenging. In this study, we extended existing petrophysical models to estimate soil moisture and salinity from electrical measurements to address this challenge. We manipulated two hydrologically isolated 2000 m 2 experimental plots by simultaneously inundating them with 265 m 3 of either freshwater or estuarine water. Repeated electrical resistivity and induced polarization measurements were used to image the water and solute infiltration along two transects that are 100 and 42 m in length. Petrophysical models derived from laboratory multi-salinity electrical measurements were used to estimate changes in soil moisture and fluid salinity from field measurements of real and imaginary conductivity during the ecosystem-scale flooding experiment. The real conductivity increased by ∼100% in the freshwater plot and ∼570% in the saltwater plot. The change in imaginary conductivity in the freshwater plot was <1 mS/m, whereas that of the estuarine water plot was ∼5 mS/m. Real conductivity shows dependence on soil moisture content with a coefficient of determination (R 2 ) > 0.7, while the imaginary conductivity shows a dependence on soil salinity with R 2 > 0.6. The results validate the use of electrical resistivity for estimating changes in soil moisture content in response to flooding. Combining electrical resistivity imaging with induced polarization measurements provides the possibility to account for changes in pore fluid conductivity.

Adebayo, Moses B. [Univ. of Toledo, OH (United Sta↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Autoignition delay times measurements of linear unsaturated jet fuel compounds inside a shock tube

Autoignition delay times measurements and CO time histories were studied for 2-pentene, a hydrocarbon in aviation fuel and an important species in the development of aviation fuel surrogates. Three mechanisms from the literature were compared against the measured data, and a sensitivity analysis for CO was performed for all mechanisms. Shock tube experiments were performed between 1246 K – 1372 K and 8.8 atm – 9.3 atm at an equivalence ratio of 1, a fuel loading of 0.25% was used and was balanced in oxygen and argon. Discrepancies between the available literature mechanisms exist, the measured data herein is essential for validation of these mechanisms and the reduction of validated mechanisms for coupling into CFD.

09 BIOMASS FUELS↗

Attosecond control and measurement of chiral photoionization dynamics

Many chirality-sensitive light–matter interactions are governed by chiral electron dynamics. Therefore, the development of advanced technologies making use of chiral phenomena would critically benefit from measuring and controlling chiral electron dynamics on their natural attosecond timescales. Such endeavours have so far been hampered by the lack of characterized circularly polarized attosecond pulses, an obstacle that has recently been overcome. Here we introduce chiroptical spectroscopy with attosecond pulses and demonstrate attosecond coherent control over photoelectron circular dichroism (PECD), as well as the measurement of chiral asymmetries in the forward–backward and angle-resolved photoionization delays of chiral molecules. We show that co-rotating attosecond and near-infrared (IR) pulses can nearly double the PECD and even change its sign compared with single-photon ionization. We demonstrate that chiral photoionization delays depend on both polar and azimuthal angles of photoemission in the light-propagation frame, requiring 3D momentum resolution. We measure forward–backward chiral-sensitive delays of up to 60 as and polar-angle-resolved photoionization delays of up to 240 as, which include an asymmetry of about 60 as originating from chirality in the continuum–continuum transitions. Attosecond chiroptical spectroscopy opens the door to quantitatively understanding and controlling the dynamics of chiral molecules on the electronic timescale.

Atomic and molecular interactions with photons↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Proposed Longitudinal Profile Diagnostics for Optical Stochastic Cooling of Stored Electrons in the IOTA Ring

One of the predicted signatures of successful optical stochastic cooling (OSC) in the Fermilab Integrable Optics Test Accelerator (IOTA) ring is reduction of the bunch length. The IOTA OSC experiment is designed for a low nominal beam current (~0.1 microAmps of 100-MeV electrons) to reduce intrabeam scattering (IBS), and during cooling, OSC is expected to reduce the bunch length from ~200 ps to ~130 ps*. These equilibrium bunch lengths can be measured using a streak camera and the optical synchrotron radiation (OSR) generated in a ring dipole by the circulating beam. A similar measurement was previously performed at the Advanced Photon Source with a Hamamatsu C5680 synchroscan streak camera operating at 117.3 MHz**. In this case, synchronous summing of OSR resulted in a bunch length measurement of 276 ± 30 ps using only 57 electrons circulating at 425 MeV. At IOTA, an existing streak camera has been modified to operate at the 11th harmonic of the ring’s revolution frequency of 7.50 MHz and has been installed on an OSR port in support of the OSC experiments. The integrated system will have sufficient sensitivity and resolution for measuring the evolution and equilibrium values of the bunch length during OSC experiments.

Lumpkin, Alex H.↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

A New Reflected Target Optical Assessment System - Stage 1 Development Results: Preprint

NREL has completed stage 1 development of an indoor optical measurement tool for fully assembled heliostats and single facets. This tool began as an indoor version of NREL's NIO technique. It uses similar techniques to other available tools (deflectometry, photogrammetry, etc.), but is designed require very little infrastructure, labor, and time to set up and collect surface slope and canting measurements on fully assembled heliostats and parabolic trough facets, making it a valuable tool for quality assurance and laboratory measurement of helio-stat optics. It accomplishes this by using computer vision, photogrammetry, and multiple images stitched together to minimize the printed target size and required setup precision. This adaptable setup is useful for taking measurements at a variety of heliostat pointing angles, and for measuring fully assembled heliostats on the assembly line. The measurement system's methodology and an analysis of its uncertainty, sensitivity and comparison with established optical measurement systems is described below.

canting↗

Electronic and magnetic phase diagrams of the Kitaev quantum spin liquid candidate Na 2 Co 2 TeO 6

The 3⁢d 7 Co 2+ -based insulating magnet Na 2 ⁢Co 2 ⁢TeO 6 has recently been reported to have strong Kitaev interactions on a honeycomb lattice and is thus being considered as a Kitaev quandum spin liquid candidate. However, due to the existence of other types of interactions, a spontaneous long-range magnetic order occurs. This order is suppressed by applied magnetic fields leading to a succession of phases and ultimately saturation of the magnetic moments. The precise phase diagram, the nature of the phases, and the possibility that one of the field-induced phases is a Kitaev quantum spin liquid phase are still a matter of debate. Here, in this study, we measured an extensive set of physical properties to build the complete temperature-field phase diagrams to magnetic saturation at 10 T for magnetic fields along the a and a* axes, and a partial phase diagram up to 60 T along c. We probe the phases using magnetization, specific heat, magnetocaloric effect, magnetostriction, dielectric constant, and electric polarization, which is a symmetry-sensitive probe. With these measurements, we identify all the previously incomplete phase boundaries and find additional high-field phase boundaries. We find strong magnetoelectric coupling in the dielectric constant and moderate magnetostrictive coupling at several phase boundaries. Furthermore, we detect the symmetry of the magnetic order using electrical polarization measurements under magnetic fields. Based on our analysis, the absence of electric polarization under zero or finite magnetic field in any of the phases or after any combination of magnetic/electric field cooling suggests that a zigzag spin structure is more likely than a triple-Q spin structure at zero field. Finally, we investigate the hysteresis and first- or second-order nature of each phase transition and its entropy changes. With this information, we establish a map of the magnetic phases of this compound and its magnetic, thermodynamic, and magnetoelectric properties, and discuss where spin liquid or other phases may be sought in future studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Four ppm measurement of the antihydrogen ground-state hyperfine splitting

The hydrogen atom is a touchstone for the foundations, evolution and frontiers of quantum theory. Key spectral lines of this atom have been determined to remarkable precision. Our research focuses on the study of antihydrogen, the antimatter counterpart of hydrogen. We test fundamental symmetries of nature (such as simultaneous charge conjugation, parity inversion, and time reversal or CPT symmetry) through precision comparisons of these atomic systems. Recent 1S–2S spectroscopic measurements on trapped antihydrogen have achieved relative precisions of parts per trillion. However, the ground-state hyperfine splitting, which is sensitive to the internal structure of the antiproton, has only been measured to 400 parts per million (ppm). Here we report a 4 ppm measurement of the antihydrogen ground-state hyperfine splitting energy a 1S , advancing the state-of-the-art precision by two orders of magnitude. From microwave spectroscopy experiments with roughly 24,000 anti-atoms, we determine ${a}_{1{\rm{S}}}/h=\mathrm{1,420,404.8}\pm 1.1(\mathrm{stat.})\pm 5.6\,(\mathrm{sys.})\,\text{kHz}$ in a 1-T magnetic field, consistent with expectations for hydrogen. At this level, our measurement is sensitive to the internal structure of the antiproton, which contributes at about 40 ppm and is approaching the limit of existing theoretical analyses. The gains we report are the product of marked advances in magnetic trap field control, stabilization and characterization; anti-atom spin-state manipulation; and improved antihydrogen accumulation rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Residual loss due to magnetic flux trapping in niobium superconducting microwave cavities

One of the significant source of radio frequency loss in superconducting microwave cavities is the trapped residual magnetic field during the cooldown due to the incomplete Messier effect. The sensitivity of flux trapping depends on the distribution of impurities, network of dislocations and defects which pin vortices. Recent advancement in cavity processing techniques resulted in very high quality factors with impurity doping, however the rf loss related to the flux trapping increases. High quality factor in SRF cavities is not only limited to particle accelerators but also emerging as an application to quantum computing and quantum information science. In this presentation, we present the results of measurements of flux trapping sensitivity on several 1.3 GHz elliptical accelerating cavities with different grain size, impurity content and surface preparations.

Dhakal, P.↗

Diagnosing the DARHT Electron Beam-Target Interaction and Hydrodynamic Expansion [Dissertation]

Quantitative electron beam-target interaction studies on the Dual-Axis Radiographic Hydrodynamic Test (DARHT) electron linear induction accelerators have only been performed recently. This includes characterization of the temperature, density, pressure, extent, and expansion velocity of the plasma plume. The results presented in this dissertation present a detailed and unified overview of the accelerator systems, target heating physics, beam transport, and diagnostic tools. Additional information includes calibration sources, radiation hydrodynamics, spectroscopic-quality radiation transport modeling, experimental measurements, and analyses of electron beam driven aluminum experiments. The first set of spatially and temporally resolved spectroscopic measurements of electron beam driven aluminum are presented. Contamination quantification analyses are used to understand the origin of the strong Na-I 3p-3s lines that are observed in absorption within the aluminum plasma continuum. These results inform the creation of the first spectroscopic-quality radiation transport model that links several atomic physics codes to interpret the conditions from which the Na-I lines originate. A good agreement is found between the surface analysis results and the model which confirms the concentration of the sodium present within the aluminum alloy foil material. It also demonstrates, for the first time on electron beam-driven target experiments, the ability to interpret plasma conditions from measured absorption lines. In a second experimental campaign which focuses on pure aluminum, the Al-I 3p-4s and 3p3d doublets are both measured in emission. A detailed analysis of the Al-I 3p-4s doublet reveals that the lines undergo moderate self-absorption. A simple model of the self-absorption effect is successfully used to match measured spectra at various temperature/density/plasma scale length combinations. These measurements led to the realization of the minimum density that can be resolved by the spectrometers for the Al-I 3p-4s lines due to the large slit width required to observe a signal on aluminum. These measurements also demonstrate the sensitivity of visible and long wave UV spectroscopy to minor changes in both temperature and density. The simple self-absorption model will be useful for analysis of other beam-target interaction experiments with spectra exhibiting either self-absorption or full self-reversal. Substantial headway has been made on the modeling front by linking together several codes needed to model both the energy deposition, hydrodynamic motion, and atomic kinetics to produce synthetic spectral calculations that are compared with experimental measurements. There exists ample space for improvement, especially with benchmarking the hydrodynamics codes and equation-of-state tables with experimental measurements. The X-ray diagnostics required to make these new measurements along with the simulation capabilities required to interpret the results are under development and will be the subject of future studies.

43 PARTICLE ACCELERATORS↗