Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

X-band noise temperature near the Sun at a 34-meter high efficiency antenna

The X-band system noise temperature near the Sun was measured at the DSS 15, a 34 meter high efficiency (HEF) antenna, in November 1987. Data was taken at angles off the center of the Sun from 0 to 4 degrees. At angles greater than 0.5 degree, the measured results agree with Voyager tracking data taken at solar conjunction in late December 1987. Within the solar disk, at angles lower than 0.27 degree, the temperature measured was lower than the prediction of a model by 30 percent, after adjusting for known receiver nonlinearities. The discrepancy in this extreme case is probably caused by unknown nonlinearities in the receiver, uncertainties in the model, or both. The measurement is nevertheless credible for practically all Sun-Earth-probe angles of interest to deep space missions.

Rebold, T. A.↗

Calibration of a 1 meter diameter normal incidence extreme ultraviolet telescope/spectrometer

A 1-meter normal incidence telescope, with a normal incidence concave diffraction grating spectrometer at its focus, has been developed. The instrument's spectral coverage is 350 to 1150A with a spectral resolution of 5A and a peak effective area of 6 sq cm at 500A. The instrument was launched on an Aries sounding rocket on November 27, 1983 in an effort to determine the hydrogen and helium abundance in the local interstellar medium. A description of this instrument, with the primary emphasis on the methods used to calibrate it, is presented.

Jelinsky, Patrick↗

Undercooling of bulk high temperature metals in the 100 meter drop tube

The 100-meter drop tube at NASA Marshall Space Flight Center provides an excellent opportunity to study the effects of containerless, microgravity processing in metals and alloys. In a series of experiments high melting temperature pure metals were melted in an electron beam furnace and dropped in vacuum. Sample sizes ranged from 0.175 to 1.2 grams. Large undercoolings on the order of 18 percent of the melting temperature were observed in Ti, Zr, Nb, Mo, Rh, Ta, and Pt. Undercoolings of 5 to 18 percent T(m) were observed in Ru and Ir. These undercooling results are consistent, repeatable, and occur in a high percentage of experiments. The experimental technique will be presented as well as the resultant microstructures of undercooled drops. The data will be discussed with respect to nucleation theory.

Hofmeister, William↗

Voyager-Neptune telemetry - The DSN 70 meter antenna upgrade

The Deep Space Network (DSN) is responsible for the acquisition of in-situ science and engineering measurements and navigation data from spacecraft exploring the Solar System. Key characteristics of the DSN design approach, the costs to upgrade performance over the past several decades, and some fundamental constraints on performance are discussed. The specific 70-meter upgrade task and the resulting overall benefits to Voyager-Neptune and the mission set are addressed.

Hall, Justin R.↗

Space ten-meter telescope (STMT) - Structural and thermal feasibility study of the primary mirror

The structural and thermal behavior of a ten-meter primary mirror for a space optical/near-IR telescope in geosynchronous orbit is studied. The glass-type lightweighted mirror is monolithic, of the double arch type, and is supported at only three points. The computer programs SSPTA (thermal), NASTRAN (finite element), and ACCOS V (optical) are used in sequence to determine the temperature, deformation, and optical performance of the mirror. A mirror temperature of 130 K or less appears to be obtainable by purely passive means. With a fused silica or standard Zerodur blank, thermally-induced deformation is unacceptable and cannot be fully corrected by an active secondary mirror over the desired field. Either active thermal control or a blank of lower thermal expansion coefficient would be required.

Bely, Pierre Y.↗

A simplified oil-film skin-friction meter

The oil-film method of skin friction measurement, which does not require calibration, nevertheless entails that interferometric measurements of the oil film be obtained. The oil-film method is presently simplified by eliminating interferometry and its requisite polished surface, by taking direct and dynamic measurements of the oil-film slope with a small position-sensing photodiode. This technique has undergone verification in incompressible turbulent and laminar flows in flat-plate boundary layers and pipe flows; the meter is judged to be inexpensive, simple, and robust.

Bandyopadhyay, P. R.↗

DSN 64-meter antenna L-band (1668-MHz) microwave system performance overview

In 1985, L-band (1668 MHz) receive-only feed systems were installed on the three Deep Space Network 64 meter antennas to provide tracking support for two non-NASA spacecraft. The specifications, design approach, and operational test results are presented. The L-band microwave system met all of its tracking goals and is currently being upgraded to include a C-band (5000 MHz) uplink.

Withington, J.↗

Sidewall boundary-layer measurements with upstream suction in the Langley 0.3-meter transonic cryogenic tunnel

The Langley 0.3 Meter Transonic Cryogenic Tunnel has provision for boundary removal from the sidewalls to reduce sidewall interference effects on the test data. The tests carried out to determine the change in the empty test section sidewall boundary layer thickness at the model station with upstream boundary layer mass removal are described. The boundary layer measurements showed that the upstream removal region is effective in reducing the boundary layer thickness at the model station. The boundary layer displacement thickness reduced from about 1.2 percent to about .4 percent of the test section width. The boundary layer velocity profiles followed a power law variation in the outer region and showed good correlation when plotted in terms of boundary layer momentum thickness.

Murthy, A. V.↗

Automatic inspection of analog and digital meters in a robot vision system

A critical limitation of most of the robots utilized in industrial environments arises due to their inability to utilize sensory feedback. This forces robot operation into totally preprogrammed or teleoperation modes. In order to endow the new generation of robots with higher levels of autonomy techniques for sensing of their work environments and for accurate and efficient analysis of the sensory data must be developed. In this paper detailed development of vision system modules for inspecting various types of meters, both analog and digital, encountered in a robotic inspection and manipulation tasks are described. These modules are tested using industrial robots having multisensory input capability.

Trivedi, Mohan M.↗

NASA SC(2)-0714 airfoil data corrected for sidewall boundary-layer effects in the Langley 0.3-meter transonic cryogenic tunnel

This report presents the corrected aerodynamic data for A NASA SC(2)-0714 airfoil tested in the Langley 0.3-Meter Transonic Cryogenic Tunnel. This test was another in the series of tests involved in the joint NASA/U.S. industry Advanced Technology Airfoil Tests program. This 14 percent thick critical airfoil was tested at Mach numbers from 0.6 to 0.76 and angles of attack from -2.0 to 6.0 deg. The test Reynolds numbers were 4 million, 6 million, 10 million, 15 million, 30 million, 40 million, and 45 million. Corrections for the effects of the sidewall boundary layer have been made. The uncorrected data were previously published in NASA Technical Memorandum 4044.

Jenkins, Renaldo V.↗

RF performance measurement of the DSS-14 70-meter antenna at C-band/L-band

The calibration of the 70-meter antenna at C-band (5.01 GHz) and L-band (1.668 GHz) is described. This calibration comes after a modification to an existing L-band feed to include the C-band frequencies. The test technique employs noise-adding radiometers and associated equipment running simultaneously at both frequencies. The test procedure is described including block diagrams, and results are presented for efficiency, system temperature, and pointing.

Gatti, M. S.↗

Hardware and operating features of the adaptive wall test section for the 0.3-meter transonic cryogenic tunnel

A 13- by 13-inch adaptive wall test section was installed in the Langley 0.3-Meter Transonic Cryogenic Tunnel circuit. This test section has four solid walls and is configured for two-dimensional airfoil testing. The top and bottom walls are flexible and movable, whereas the sidwalls are rigid and fixed. The test section has a turntable to support airfoil models, a survey mechanism to probe the model wake, and provisions for a sidewall boundary-layer-control system. Details of the adaptive wall test section, the tunnel circuit modifications, the supporting instrumentation, the monitoring and control hardware, and the wall adaptation strategy are discussed. Sample results of shakedown tests with the test section empty and with an airfoil installed are also included.

Mineck, Raymond E.↗

Microcomputer based controller for the Langley 0.3-meter Transonic Cryogenic Tunnel

Flow control of the Langley 0.3-meter Transonic Cryogenic Tunnel (TCT) is a multivariable nonlinear control problem. Globally stable control laws were generated to hold tunnel conditions in the presence of geometrical disturbances in the test section and precisely control the tunnel states for small and large set point changes. The control laws are mechanized as four inner control loops for tunnel pressure, temperature, fan speed, and liquid nitrogen supply pressure, and two outer loops for Mach number and Reynolds number. These integrated control laws have been mechanized on a 16-bit microcomputer working on DOS. This document details the model of the 0.3-m TCT, control laws, microcomputer realization, and its performance. The tunnel closed loop responses to small and large set point changes were presented. The controller incorporates safe thermal management of the tunnel cooldown based on thermal restrictions. The controller was shown to provide control of temperature to + or - 0.2K, pressure to + or - 0.07 psia, and Mach number to + or - 0.002 of a given set point during aerodynamic data acquisition in the presence of intrusive geometrical changes like flexwall movement, angle-of-attack changes, and drag rake traverse. The controller also provides a new feature of Reynolds number control. The controller provides a safe, reliable, and economical control of the 0.3-m TCT.

Balakrishna, S.↗

Analysis of the nonvented fill of a 4.96-cubic-meter lightweight liquid hydrogen tank

As part of its development of cryogenic fluid management techniques for spacecraft, the NASA Lewis Research Center Cryogenic Fluid Technology Office (CFTO) is planning to perform ground tests of nonvented fill techniques on a 4.96-cubic-meter lightweight liquid hydrogen tank. This tank is similar in size and shape to the tankage planned for CFTO's COLD-SAT liquid hydrogen flight experiment. The analyses used to select two injection systems are presented for nonvented fills of this tank at design flow rates between 220 and 450 kg/hr. The first system uses multiple nozzles spraying from the top of the tank through the ullage space. This system should be capable of liquid fill levels in excess of 95 percent. The second system injects the liquid through a submerged nozzle and should produce fill levels on the order of 80 percent liquid.

Chato, David J.↗

Undercooling studies on Nb-Pt and Nb-Si alloys using the 105 meter drop tube

Niobium-platinum samples of compositions ranging from 16 to 32 at. pct have been undercooled to as much as 540 K in the low gravity, containerless environment of a 105 meter drop tube. Undercooling was terminated in the Nb-Pt samples by the nucleation and growth of the Nb3Pt phase. In the 16-18 at. pct Pt samples, this resulted in samples which are completely Nb3Pt, in contrast to both the equilibrium phase diagram and the nonundercooled samples which formed with Nb dendrites and interdendritic Nb3Pt. Undercoolings for the Nb-Si samples were up to 670 K, which corresponds to 27 percent of the liquidus temperature or 80 percent of the estimated hypercooling limit. In the Nb-Si system, a coupled zone was identified as well as a metastable extension of the solubility limit of Si in Nb due to deep undercooling.

Robinson, M. B.↗

The 32-GHz performance of the DSS-14 70-meter antenna: 1989 configuration

The results of preliminary 32 GHz calibrations of the 70 meter antenna at Goldstone are presented. Measurements were done between March and July 1989 using Virgo A and Venus as the primary efficiency calibrators. The flux densites of theses radio sources at 32 GHz are not known with high accuracy, but were extrapolated from calibrated data at lower frequencies. The measured value of efficiency (0.35) agreed closely with the predicted value (0.32), and the results are very repeatable. Flux densities of secondary sources used in the observations were subsequently derived. These measurements were performed using a beamswitching radiometer that employed an uncooled high-electron mobility transistor (HEMT) low-noise amplifier. This system was installed primarily to determine the performance of the antenna in its 1989 configuration, but the experience will also aid in successful future calibration of the Deep Space Network (DSN) at this frequency.

Gatti, M. S.↗

Calibration of the 13- by 13-inch adaptive wall test section for the Langley 0.3-meter transonic cryogenic tunnel

A 13 by 13 inch adaptive wall test section was installed in the 0.3 Meter Transonic Cryogenic Tunnel circuit. This new test section is configured for 2-D airfoil testing. It has four solid walls. The top and bottom walls are flexible and movable whereas the sidewalls are rigid and fixed. The wall adaptation strategy employed requires the test section wall shapes associated with uniform test section Mach number distributions. Calibration tests with the test section empty were conducted with the top and bottom walls linearly diverged to approach a uniform Mach number distribution. Pressure distributions were measured in the contraction cone, the test section, and the high speed diffuser at Mach numbers from 0.20 to 0.95 and Reynolds numbers from 10 to 100 x 10 (exp 6)/per foot.

Mineck, Raymond E.↗

Precision metering of microliter volumes of biological fluids in micro-gravity

Concepts were demonstrated and investigated for transferring accurately known and reproducible microliter volumes of biological fluids from sample container onto dry chemistry slides in microgravity environment. Specific liquid transfer tip designs were compared. Information was obtained for design of a liquid sample handling system to enable clinical chemical analysis in microgravity. Disposable pipet tips and pipet devices that were designed to transfer microliter volumes of biological fluid from a (test tube) sample container in 1-G environment were used during microgravity periods of parabolic trajectories of the KC-135 aircraft. The transfer process was recorded using charge coupled device camera and video cassette equipment. Metering behavior of water, a synthetic aqueous protein solution, and anticoagulated human blood was compared. Transfer of these liquids to 2 substrate materials representative of rapidly wettable and slowly wettable dry chemistry slide surface was compared.

Columbus, Richard L.↗