Search NASA⌕ Search

SEARCH · Search NASA

Results for “mock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Ultra-sensitive isotope probing to quantify activity and substrate assimilation in microbiomes

Abstract Background Stable isotope probing (SIP) approaches are a critical tool in microbiome research to determine associations between species and substrates, as well as the activity of species. The application of these approaches ranges from studying microbial communities important for global biogeochemical cycling to host-microbiota interactions in the intestinal tract. Current SIP approaches, such as DNA-SIP or nanoSIMS allow to analyze incorporation of stable isotopes with high coverage of taxa in a community and at the single cell level, respectively, however they are limited in terms of sensitivity, resolution or throughput. Results Here, we present an ultra-sensitive, high-throughput protein-based stable isotope probing approach (Protein-SIP), which cuts cost for labeled substrates by 50–99% as compared to other SIP and Protein-SIP approaches and thus enables isotope labeling experiments on much larger scales and with higher replication. The approach allows for the determination of isotope incorporation into microbiome members with species level resolution using standard metaproteomics liquid chromatography-tandem mass spectrometry (LC–MS/MS) measurements. At the core of the approach are new algorithms to analyze the data, which have been implemented in an open-source software ( https://sourceforge.net/projects/calis-p/ ). We demonstrate sensitivity, precision and accuracy using bacterial cultures and mock communities with different labeling schemes. Furthermore, we benchmark our approach against two existing Protein-SIP approaches and show that in the low labeling range used our approach is the most sensitive and accurate. Finally, we measure translational activity using 18 O heavy water labeling in a 63-species community derived from human fecal samples grown on media simulating two different diets. Activity could be quantified on average for 27 species per sample, with 9 species showing significantly higher activity on a high protein diet, as compared to a high fiber diet. Surprisingly, among the species with increased activity on high protein were several Bacteroides species known as fiber consumers. Apparently, protein supply is a critical consideration when assessing growth of intestinal microbes on fiber, including fiber-based prebiotics. Conclusions We demonstrate that our Protein-SIP approach allows for the ultra-sensitive (0.01 to 10% label) detection of stable isotopes of elements found in proteins, using standard metaproteomics data.

59 BASIC BIOLOGICAL SCIENCES↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

Alkaline-SDS cell lysis of microbes with acetone protein precipitation for proteomic sample preparation in 96-well plate format

Plate-based proteomic sample preparation offers a solution to the large sample throughput demands in the biotechnology field where hundreds or thousands of engineered microbes are constructed for testing is routine. Meanwhile, sample preparation methods that work efficiently on broader microbial groups are desirable for new applications of proteomics in other fields, such as microbial communities. Here, we detail a step-by-step protocol that consists of cell lysis in an alkaline chemical buffer (NaOH/SDS) followed by protein precipitation with high-ionic strength acetone in 96-well format. The protocol works for a broad range of microbes ( e . g ., Gram-negative bacteria, Gram-positive bacteria, non-filamentous fungi) and the resulting proteins are ready for tryptic digestion for bottom-up quantitative proteomic analysis without the need for desalting column cleanup. The yield of protein using this protocol increases linearly with respect to the amount of starting biomass from 0.5–2.0 OD*mL of cells. By using a bench-top automated liquid dispenser, a cost-effective and environmentally-friendly option to eliminating pipette tips and reducing reagent waste, the protocol takes approximately 30 minutes to extract protein from 96 samples. Tests on mock mixtures showed expected results that the biomass composition structure is in close agreement with the experimental design. Lastly, we applied the protocol for the composition analysis of a synthetic community of environmental isolates grown on two different media. This protocol has been developed to facilitate rapid, low-variance sample preparation of hundreds of samples and allow flexibility for future protocol development.

59 BASIC BIOLOGICAL SCIENCES↗

Experiments and modelling of adhesive failure initiation of an epoxy underfill: a study of electronic packaging survivability

Epoxy underfills can be implemented in electronic packaging to enhance solder joint reliability of surface mounted components. However, it is important for an engineer to have a failure criterion that can be used for failure predictions and redesign of electronic assemblies. For this study, data from epoxy bond failure in mock electronic part assemblies were correlated to finite element analyses to predict adhesive failure initiation. Experiments were performed to determine failure loads for various loading locations and nonlinear viscoelastic analyses were performed for the same loading locations to determine a maximum principal strain failure parameter. Predictions showed that a maximum principal strain failure parameter defined from one test could be used as an indicator of adhesive failure of an epoxy bond undergoing other modes of loading. Failure initiation predictions matched experimental data using a maximum principal strain failure parameter for an epoxy bond undergoing mixed modes of loading for both unfilled and alumina oxide filled 828DEA epoxy. Such experimental setup is deemed appropriate for future epoxy testing.

42 ENGINEERING↗

HE Production Update at JLab - Introducing an Enhanced Nitrogen Purge for Clean String Assembly

A major limitation to cryomodule performance is field emission caused by particulates within the superconducting cavities. To reduce contamination of the inner surfaces during assembly in a cleanroom, the whole string can be connected to a purge system, which maintains a constant overpressure of dry, clean nitrogen gas. Following successes of similar systems at XFEL and Fermilab, Jefferson Lab followed this example for the production of LCLS-II HE cryomodules. Implementing this system required new procedures, infrastructure, and hardware, as well as significant testing of the system before production began. This paper will summarize the implemented controls and procedures, including lessons learned from Fermilab, as well as the results of mock-up tests. Based on the latter, the system was used to assemble the first article string in April 2022, and was also used during a rework required due to issues with cold FPC ceramics two months later. The benefits of using a purge system with regards to procedure, time savings, and added flexibility for potential rework have already proven to provide a significant improvement for the production of LCLS-II-HE cryomodules at Jefferson Lab.

Owen, P. D.↗

FIRST RESULTS FROM Nb3Sn COATINGS OF 2.6 GHz Nb SRF CAVITIES USING DC CYLINDRICAL MAGNETRON SPUTTERING SYSTEM

A DC cylindrical magnetron sputtering system has been commissioned and operated to deposit Nb3Sn onto 2.6 GHz Nb SRF cavities. After optimizing the deposition conditions in a mock-up cavity, Nb-Sn films are deposited first on flat samples by multilayer sequential sputtering of Nb and Sn, and later annealed at 950 °C for 3 hours. X-ray diffraction of the films showed multiple peaks for the Nb3Sn phase and Nb (substrate). No peaks from any Nb-Sn compound other than Nb3Sn were detected. Later three 2.6 GHz Nb SRF cavities are coated with ~1 µm thick Nb3Sn. The first Nb3Sn coated cavity reached close to Eacc = 8 MV/m, demonstrating a quality factor Q0 of 3.2 × 108 at Tbath = 4.4 K and Eacc = 5 MV/m, about a factor of three higher than that of Nb at this temperature. Q0 was close to 1.1 × 109, dominated by the residual resistance, at 2 K and Eacc = 5 MV/m. The Nb3Sn coated cavities demonstrated Tc in the range of 17.9 ? 18 K. Here, we present the commissioning experience, system optimization, and the first results from the Nb3Sn fabrication on flat samples and SRF cavities.

Shakel, M.S.↗

The catalog-to-cosmology framework for weak lensing and galaxy clustering for LSST

We present TXPipe, a modular, automated and reproducible pipeline for ingesting catalog data and performing all the calculations required to obtain quality-assured two-point measurements of lensing and clustering, and their covariances, with the metadata necessary for parameter estimation. The pipeline is developed within the Rubin Observatory Legacy Survey of Space and Time (LSST) Dark Energy Science Collaboration (DESC), and designed for cosmology analyses using LSST data. In this paper, we present the pipeline for the so-called 3x2pt analysis -- a combination of three two-point functions that measure the auto- and cross-correlation between galaxy density and shapes. We perform the analysis both in real and harmonic space using TXPipe and other LSST-DESC tools. We validate the pipeline using Gaussian simulations and show that it accurately measures data vectors and recovers the input cosmology to the accuracy level required for the first year of LSST data under this simplified scenario. We also apply the pipeline to a realistic mock galaxy sample extracted from the CosmoDC2 simulation suite (Korytov et al. 2019). TXPipe establishes a baseline framework that can be built upon as the LSST survey proceeds. Furthermore, the pipeline is designed to be easily extended to science probes beyond the 3x2pt analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

DES Y3 + KiDS-1000: Consistent cosmology combining cosmic shear surveys

We present a joint cosmic shear analysis of the Dark Energy Survey (DES Y3) and the Kilo-Degree Survey (KiDS-1000) in a collaborative effort between the two survey teams. We find consistent cosmological parameter constraints between DES Y3 and KiDS-1000 which, when combined in a joint-survey analysis, constrain the parameter $S_8 = \sigma_8 \sqrt{\Omega_{\rm m}/0.3}$ with a mean value of $0.790^{+0.018}_{-0.014}$. The mean marginal is lower than the maximum a posteriori estimate, $S_8=0.801$, owing to skewness in the marginal distribution and projection effects in the multi-dimensional parameter space. Our results are consistent with $S_8$ constraints from observations of the cosmic microwave background by Planck, with agreement at the $1.7\sigma$ level. We use a Hybrid analysis pipeline, defined from a mock survey study quantifying the impact of the different analysis choices originally adopted by each survey team. We review intrinsic alignment models, baryon feedback mitigation strategies, priors, samplers and models of the non-linear matter power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Formulation via Resonant Acoustic Mixing at LANL

Discussions in the middle of 2014 led researchers at LANL to seek an alternate formulation method for making PBX based explosives. We began looking into the use of Resonant Acoustic Mixers (RAM) to formulate explosives and mocks. Acoustic mixing had been used in pharmaceutical plants for mixing medicines and coating materials, so we envisioned transitioning that same technology to the energetics world. Up until this time only the wet slurry formulation method that had been used was from the 1940’s. This wet slurry method had been and still was the standard for all explosive formulations. The possibility of an alternate method needed to be looked at to advance the process by expanding solvent choices, substrates, and reducing costs. Acoustic mixing had been shown to mix powders, slurries, pastes or even liquids. A Resodyn LabRAM was purchased in late 2014 to explore these possible applications to energetics. This LabRAM was in a remote configuration that met our need for explosive operations.

36 MATERIALS SCIENCE↗

Development of a Nitrogen and Magnesium Oxide based Class A, B & D Suffocating Fire System (SFSS) for Gloveboxes

Testing related to the development and performance of a “Proof of Concept” Nitrogen/Magnesium Oxide Suffocating Fire System (SFSS) was conducted at Fire and Pump Service Group (FPSG) located in Rancho Dominguez, California. The SFSS Engineering Team (SFSSET), consisting of FPSG and Los Alamos National Laboratory (LANL) personnel researched, developed a prototype, and conducted testing to determine effective means to deliver magnesium oxide (MgO) sand into a glovebox (GB) in a class D fire event. The prototypes development also established the effective coverage area of a magnesium oxide suppression system as well as demonstrated that the GB inert atmosphere could be maintained during and after the release of the MgO sand to control Class A, B and D fires. Previous testing conducted on nitrogen based SFSS provided evidence that the nitrogen based SFSS controlled Class A and B fires (Ralph Clayton, Los Alamos National Laboratory, Brandon Troc and Frank Broidy, Fire and Pump Service Group 2020).Final testing was conducted within a mock GB capable of simulating an inert glovebox atmosphere. Testing demonstrated that the inert atmosphere can be maintained during and after discharge of the MgO sand over a coverage area.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Sealed Vessel Leak Test [Slides]

A test plan has been developed to verify the results obtained from sealed vessels used in support of the JT5-Alt370-IN-1 compatibility testing. The test plan needs to be verified by doing a mock test on testing vessels, it will be adjusted and redone as necessary then conducted on the remaining vessels from the compatibility tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Versatile Remediation Module Final Operational Testing Results

Oak Ridge National Laboratory (ORNL) successfully demonstrated the Versatile Remediation Module (VRM), a prototype module designed and built by ORNL for performing the on-site remote repair of welded stainless-steel storage containers for spent nuclear fuel and high-level radioactive waste. This report describes the VRM prototype and its design features, components, qualification tests, operational procedures, and demonstration results to support continued long-term storage or off-site transportation of spent nuclear fuel and high-level radioactive waste currently stored in storage containers. A remote (i.e., 100 ft away from the simulated radiative environment) demonstration of the VRM was successfully performed on a full-scale mock-up welded stainless-steel canister. The VRM is designed with features to accommodate remediation techniques beyond those currently selected and described in this report. Therefore, many of the VRM’s features could benefit other remote nuclear or nonnuclear applications. The VRM is envisioned to serve as a development center to facilitate and enhance the further development of new remediation technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IER-539 CED-1: Preliminary Design of a New Horizontal Split Table

This report presents the preliminary design (CED-1) of IER-539, focused on a new Horizontal Split Table (HST) critical assembly machine. The Department of Energy (DOE) National Nuclear Criticality Safety Program (NCSP) funds critical experiment R&D and its Mission and Vision document identifies a long-standing technical gap of a general purpose HST. HSTs have historically been used for experiments that are impractical to assemble on a vertical lift machine (VLM), usually due to their large physical size or weight. While many HSTs were historically employed in the US (including at LLNL), there are currently no surviving HSTs in the US. While there are two critical experiments facilities remaining in the US, the National Critical Experiments Research Center (NCERC) operated by LANL and the Critical Experiments Facility (CX) operated by SNL, these facilities are not equipped with a general purpose HST. There are a number of experiment designs that require an HST, including needs for Defense Programs and Nuclear Energy. Lack of an HST constraints the national ability to perform large and heavy experiments. Large footprints are needed to successfully create mockup experiments for advanced reactors (mock-up cold critical reactor cores, which is a urgent need for new reactor designs using novel materials and longer cycle lengths), to create solution experiments in lattices, or to test nuclear data of heavy metals. A new HST is a vital piece of criticality experiment infrastructure that would allow for the conduct of integral critical experiments to address needs in the nuclear criticality safety, nuclear data, and other DOE stakeholder communities.

42 ENGINEERING↗

Multidisciplinary Research and Development at the Dual-Axis Radiograph Hydrodynamic Test Facility (DARHT) [Slides]

DARHT is the nation’s premiere flash radiography facility. Flash radiography allows interior views of complex structures that are rapidly moving. DARHT is used to image the implosion of mock weapon assemblies containing surrogate materials. DARHT is the only dual-axis facility in the nation enabling 3D reconstructions, with multi-pulse capability for multiple time points. DARHT is an essential facility for Science-based Stockpile Stewardship at LANL and within the NNSA complex.

43 PARTICLE ACCELERATORS↗

Preconceptual Design of Irradiated Fuel Salt Management System

The National Reactor Innovation Center was established by the U.S. Department of Energy to accelerate the demonstration and deployment of advanced nuclear reactors. To meet this mission, the National Reactor Innovation Center has developed the Laboratory for Operations and Testing in the U.S. (LOTUS) to support the first fast-spectrum molten salt reactor demonstration. The goal of this research is to understand the system requirements that may be applied to a molten salt reactor experiment in the LOTUS test bed and to perform systems analyses and preconceptual development of a storage container for the management of the irradiated molten salt fuel. This study proposes a set of irradiated fuel salt management processes for the molten salt reactor, from defueling to storage or disposal. For that, the historic Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has served as a crucial source of data for a mock application. This paper proposes a potential geometry for storing irradiated fuel salt based on MSRE data and the Monte Carlo N-Particle radiation transport code. The geometry was analyzed for criticality safety under abnormal situations, such as water ingress and interaction between containers. Based on the determined configuration of the storage system, the decay heat produced from the irradiated fuel salts was calculated to provide a reasonable time scale of the dormancy period. Using the same geometry assumed above, the neutron and gamma dose rates from the irradiated fuel salt at the end of the dormancy period were estimated, which will be useful for understanding the handling and radiation protection requirements for handling the irradiated fuel salt. Lastly, a reactor in the LOTUS test bed could use chloride-based fuel as opposed to the fluoride-based fuel used in MSRE. Thus, a literature study provided data to understand the similarities and differences between the characteristics of fluoride- and chloride-based salts in terms of salt chemistry, material characteristics, postirradiation behavior, neutronics, thermal hydraulics, and heat removal. This study, together with the proposed irradiated fuel salt management processes, preliminary criticality calculations, decay heat, and dose rate estimates, provides a strong basis for future investigation into the management of irradiated fuel salts generated during molten salt reactor technology demonstrations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty Quantification in High-Low Dynamic System Coupling Using RAVEN and TRANSFORM

This report demonstrates new functionality and applications stemming from the development of high fidelity to low fidelity (high-low) coupling for system simulations and to further explore the capabilities of RAVEN in the performance of uncertainty quantification in this kind of high-low coupled system models. The work builds from previous work on high-low coupling that utilized CTF, the high fidelity subchannel analysis code, with a low fidelity model built in TRANSFORM, the system analysis code, utilizing the Functional Mock-Up Interface (FMI)

97 MATHEMATICS AND COMPUTING↗