Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple light scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Search for critical point indications in long-range correlations by energy and system size scanning in string fusion approach

The ultrarelativistic collisions of heavy and light ions in the center-of-mass energy range from a few up to a hundred GeV per nucleon have been considered in string fusion approach. A Monte Carlo model of proton-proton, proton-nucleus, and nucleus-nucleus collisions has been developed, which takes into account both the string fusion and the finite rapidity length of strings, implementing the hadronic scattering through the interaction of color dipoles. It well describes the proton-nucleus and nucleus-nucleus collisions at the partonic level without using Glauber model of nuclear collisions. All parameters are fixed using experimental data on inelastic cross section and multiplicity. In the framework of the model, we performed a beam energy and system size scan and studied the behaviour of n-n, pt-n and pt-pt long-range correlation coefficients. The detailed modeling of the event by event charged particles production allowed to provide predictions in the conditions close to the experimental ones allowing a direct comparison to the data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An interlaboratory comparison of mid-infrared spectra acquisition: Instruments and procedures matter

Diffuse reflectance spectroscopy has been extensively employed to deliver timely and cost-effective predictions of a number of soil properties. However, although several soil spectral laboratories have been established worldwide, the distinct characteristics of instruments and operations still hamper further integration and interoperability across mid-infrared (MIR) soil spectral libraries. In this study, we conducted a large-scale ring trial experiment to understand the lab-to-lab variability of multiple MIR instruments. By developing a systematic evaluation of different mathematical treatments with modeling algorithms, including regular preprocessing and spectral standardization, we quantified and evaluated instruments' dissimilarity and how this impacts internal and shared model performance. We found that all instruments delivered good predictions when calibrated internally using the same instruments' characteristics and standard operating procedures by solely relying on regular spectral preprocessing that accounts for light scattering and multiplicative/additive effects, e.g., using standard normal variate (SNV). When performing model transfer from a large public library (the USDA NSSCKSSL MIR library) to secondary instruments, good performance was also achieved by regular preprocessing (e. g., SNV) if both instruments shared the same manufacturer. However, significant differences between the KSSL MIR library and contrasting ring trial instruments responses were evident and confirmed by a semi-unsupervised spectral clustering. For heavily contrasting setups, spectral standardization was necessary before transferring prediction models. Non-linear model types like Cubist and memory-based learning delivered more precise estimates because they seemed to be less sensitive to spectral variations than global partial least square regression. In summary, the results from this study can assist new laboratories in building spectroscopy capacity utilizing existing MIR spectral libraries and support the recent global efforts to make soil spectroscopy universally accessible with centralized or shared operating procedures.

58 GEOSCIENCES↗

SU-E-J-125: Classification of CBCT Noises in Terms of Their Contribution to Proton Range Uncertainty

Purpose: This study assesses the potential use of CBCT images in adaptive protontherapy by estimating the contribution of the main sources of noise and calibration errors to the proton range uncertainty. Methods: Measurements intended to highlight each particular source have been achieved by adapting either the testbench configuration, e.g. use of filtration, fan-beam collimation, beam stop arrays, phantoms and detector reset light, or the sequence of correction algorithms including water precorrection. Additional Monte-Carlo simulations have been performed to complement these measurements, especially for the beam hardening and the scatter cases. Simulations of proton beams penetration through the resulting images have then been carried out to quantify the range change due to these effects. The particular case of a brain irradiation is considered mainly because of the multiple effects that the skull bones have on the internal soft tissues. Results: On top of the range error sources is the undercorrection of scatter. Its influence has been analyzed from a comparison of fan-beam and full axial FOV acquisitions. In this case, large range errors of about 12 mm can be reached if the assumption is made that the scatter has only a constant contribution over the projection images. Even the detector lag, which a priori induces a much smaller effect, has been shown to contribute for up to 2 mm to the overall error if its correction only aims at reducing the skin artefact. This last result can partially be understood by the larger interface between tissues and bones inside the skull. Conclusion: This study has set the basis of a more systematical analysis of the effect CBCT noise on range uncertainties based on a combination of measurements, simulations and theoretical results. With our method, even more subtle effects such as the cone-beam artifact or the detector lag can be assessed. SBR and JOR are financed by iMagX, a public-private partnership between the region Wallone of Belgium and IBA under convention #1217662.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the recombination process at crystallite boundaries in CuIn{sub 1-x}Ga{sub x}Se{sub 2} (CIGS) films by microwave photoconductivity

The loss kinetics of photogenerated charge carriers in thin polycrystalline chalcopyrite CuIn{sub 1-x}Ga{sub x}Se{sub 2} (CIGS) films has been studied by microwave photoconductivity (at 36 GHz). The films were synthesized using the ampoule method and three variants of physical vapor deposition with subsequent selenization: magnetron sputtering, thermal deposition, and modified thermal deposition with intermetallic precursors. The photoconductivity was excited by 8-ns nitrogen laser pulses with maximum intensity of 4 Multiplication-Sign 10{sup 14} photons/cm per pulse. Measurements were performed in the temperature range 148-293 K. The photoresponse amplitude is found to depend linearly on the sizes of coherent-scattering regions in the film grains, which were calculated from X-ray diffraction data. The photoresponse decay obeys hyperbolic law. The photoresponse half-decay time increases with a decrease in both temperature and light intensity. It is shown that the recombination of free holes with trapped electrons is very efficient near the crystallite boundaries.

36 MATERIALS SCIENCE↗

Characterization of fluid flow by digital correlation of scattered light

The objective is to produce a physical system suitable for a space environment that can measure fluid velocities in a three-dimensional volume by the development of a particle correlation velocimetry technique. Experimental studies were conducted on a field test cell to demonstrate the suitability and accuracy of digital correlation techniques for measuring two-dimensional fluid flows. This objective was satisfied by: (1) the design of an appropriate illumination and detection system for making velocity measurements within a test cell; (2) the design and construction of a test cell; (3) the preliminary evaluations on fluid and seeding requirements; and (4) the performance of controlled tests using a multiple exposure correlation technique. This presentation is represented by viewgraphs with very little text.

Gilbert, John A.↗

Analysis of light propagation for a crossing of thin silicon wires using vertical tunnelling coupling with a thick optical channel waveguide

Using silicon photonic wires in a silicon-on-insulator structure as an example, we examine the problem of crossings of thin, high-index-contrast channel waveguides. To ensure high optical wave transmission efficiency at as low a level of parasitic scattering as possible, we propose using a structure with vertical coupling between a thin tapered silicon waveguide and a thick polymer waveguide, separated by a thin buffer oxide layer. Numerical simulation is used to find conditions under which such a structure (3 × 90 μm in dimensions) ensures 98 % and 99 % transmission efficiency at ∼1.55 μm in 35- and 26-nm spectral ranges, respectively, for direct propagation and 99.99 % transmission in the transverse direction. The optical element in question is proposed for use in optical microchips with multiple channel waveguide crossings. (integrated optical waveguides)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of multiple optical transitions in 87Rb using laser diodes

Recent work with laser diodes has indicated their potential usefulness in optically pumping atomic frequency standards. Various optical pumping schemes for (87)Rb incorporating such light sources at two D1 frequencies for experimental situations of either evacuated wall-coated cells or atomic beams are considered. Numerical integration of rate equations governing the level populations with arbitrary pumping light choices of intensity, D1 hyperfine transition(s), and polarization and subsequent calculation of scattered light provide a simplified 0-0 hyperfine signal analysis. By frequency modulating one laser diode, two optical transitions were excited in an evacuated wall-coated cell and a large delta m(F) = 1 hf signal was observed.

Newton, C. L. J.↗

Nephelometer PSAP, BBOP

This field campaign will address multiple uncertainties in aerosol intensive properties, which are poorly represented in climate models, by means of aircraft measurements in biomass burning plumes. Key topics to be investigated are: Aerosol mixing state and morphology Mass absorption coefficients (MACs) Chemical composition of non-refractory material associated with light-absorbing carbon (LAC) Production rate of secondary organic aerosol (SOA) Microphysical processes relevant to determining aerosol size distributions and single scattering albedo (SSA) CCN activity.

54 ENVIRONMENTAL SCIENCES↗

Multi-Parameter Aerosol Scattering Sensor

This work relates to the development of sensors that measure specific aerosol properties. These properties are in the form of integrated moment distributions, i.e., total surface area, total mass, etc., or mathematical combinations of these moment distributions. Specifically, the innovation involves two fundamental features: a computational tool to design and optimize such sensors and the embodiment of these sensors in actual practice. The measurement of aerosol properties is a problem of general interest. Applications include, but are not limited to, environmental monitoring, assessment of human respiratory health, fire detection, emission characterization and control, and pollutant monitoring. The objectives for sensor development include increased accuracy and/or dynamic range, the inclusion in a single sensor of the ability to measure multiple aerosol properties, and developing an overall physical package that is rugged, compact, and low in power consumption, so as to enable deployment in harsh or confined field applications, and as distributed sensor networks. Existing instruments for this purpose include scattering photometers, direct-reading mass instruments, Beta absorption devices, differential mobility analyzers, and gravitational samplers. The family of sensors reported here is predicated on the interaction of light and matter; specifically, the scattering of light from distributions of aerosol particles. The particular arrangement of the sensor, e.g. the wavelength(s) of incident radiation, the number and location of optical detectors, etc., can be derived so as to optimize the sensor response to aerosol properties of practical interest. A key feature of the design is the potential embodiment as an extremely compact, integrated microsensor package. This is of fundamental importance, as it enables numerous previously inaccessible applications. The embodiment of these sensors is inherently low maintenance and high reliability by design. The novel and unique features include the underlying computational underpinning that allows the optimization for specific applications, and the physical embodiment that affords the construction of a compact, durable, and reliable integrated package. The advantage appears in the form of increased accuracy relative to existing instruments, and the applications enabled by the physical attributes of the resulting configuration

Greenberg, Paul S.↗

Study of the interaction between $Ξ$ baryons and light mesons via femtoscopy at the LHC

Meson-baryon systems with strangeness content provide a unique laboratory for investigating the strong interaction and testing theoretical models of hadron structure and dynamics. In this work, the measured correlation functions for oppositely charged $Ξ$-K and $Ξ$ − 𝜋 pairs obtained in high-multiplicity pp collisions at $\sqrt{𝑠}$ = 13 TeV at the LHC are presented. For the first time, high-precision data on the $Ξ$-K interaction are delivered at small relative momenta. The scattering lengths, extracted via the Lednický–Lyuboshits expression of the pair wavefunction, indicate a repulsive and a shallow attractive strong interaction for the $Ξ$-K and $Ξ$ − 𝜋 systems, respectively. The $Ξ$(1620) and $Ξ$(1690) states are observed in the $Ξ$ − 𝜋 correlation function and their properties, mass and width, are determined. These measurements are in agreement with other available results. Such high-precision data can help refine the understanding of these resonant states, provide stronger constraints for chirally motivated potentials, and address the key challenge of describing the coupled-channel dynamics that may give rise to molecular configurations .

Femtoscopy↗

Enhanced polarization of (11–22) semi-polar InGaN nanorod array structure

By means of a cost effective nanosphere lithography technique, an InGaN/GaN multiple quantum well structure grown on (11–22) semipolar GaN has been fabricated into two dimensional nanorod arrays which form a photonic crystal (PhC) structure. Such a PhC structure demonstrates not only significantly increased emission intensity, but also an enhanced polarization ratio of the emission. This is due to an effective inhibition of the emission in slab modes and then redistribution to the vertical direction, thus minimizing the light scattering processes that lead to randomizing of the optical polarization. The PhC structure is designed based on a standard finite-difference-time-domain simulation, and then optically confirmed by detailed time-resolved photoluminescence measurements. The results presented pave the way for the fabrication of semipolar InGaN/GaN based emitters with both high efficiency and highly polarized emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

What is the iε for the S-matrix?

Can the S-matrix be complexified in a way consistent with causality? Since the 1960's, the affirmative answer to this question has been well-understood for 2→2 scattering of the lightest particle in theories with a mass gap at low momentum transfer, where the S-matrix is analytic everywhere except at normal-threshold branch cuts. We ask whether an analogous picture extends to realistic theories, such as the Standard Model, that include massless fields, UV/IR divergences, and unstable particles. Especially in the presence of light states running in the loops, the traditional iε prescription for approaching physical regions might break down, because causality requirements for the individual Feynman diagrams can be mutually incompatible. We demonstrate that such analyticity problems are not in contradiction with unitarity. Instead, they should be thought of as finite-width effects that disappear in the idealized 2→2 scattering amplitudes with no unstable particles, but might persist at higher multiplicity. To fix these issues, we propose an iε -like prescription for deforming branch cuts in the space of Mandelstam invariants without modifying the analytic properties. This procedure results in a complex strip around the real part of the kinematic space, where the S-matrix remains causal. In addition to giving a pedagogical introduction to the analytic properties of the perturbative S-matrix from a modern point of view, we illustrate all the points on explicit examples, both symbolically and numerically. Furthermore, to help with the investigation of related questions, we introduce a number of tools, including holomorphic cutting rules, new approaches to dispersion relations, as well as formulae for local behavior of Feynman integrals near branch points.

Anomalous thresholds↗

Multiple Fano interferences in a plasmonic metamolecule consisting of asymmetric metallic nanodimers

We theoretically explore signatures of plasmonic Fano interferences in a subwavelength plasmonic metamolecule consisting of closely packed asymmetric gold nanodimers, which lead to the possibility of generating multiple Fano resonances in the scattering spectrum. This spectral feature is attributed to the interference between bright and dark plasmonic modes sustained by the constituent nanodimers. The excited Fano dips are highly sensitive in both wavelength and amplitude to geometry and background dielectric medium. The tunability of induced Fano resonances associated with enhanced electric fields from the visible to infrared region provides promising applications, particularly in refractive index sensing, light-trapping, and photon up-converting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing lattice dynamics and electron-phonon coupling in the topological nodal-line semimetal ZrSiS

Topological materials provide an exclusive platform to study the dynamics of relativistic particles in table-top experiments and offer the possibility of wide-scale technological applications. ZrSiS is a newly discovered topological nodal-line semimetal and has drawn enormous interests. In this paper, we have investigated the lattice dynamics and electron-phonon interaction in single-crystalline ZrSiS using Raman spectroscopy. Polarization and angle-resolved Raman data have been analyzed using crystal symmetries and theoretically calculated atomic vibrational patterns along with phonon dispersion spectra. Wavelength- and temperature-dependent measurements show the complex interplay of electron and phonon degrees of freedom, resulting in resonant phonon and quasielastic electron scattering through interband transition. Our high-pressure Raman studies reveal vibrational anomalies, which are the signature of structural phase transitions. Further investigations through high-pressure synchrotron x-ray diffraction clearly show pressure-induced structural transitions and coexistence of multiple phases, which also indicate possible electronic topological transitions in ZrSiS. Lastly, this study not only provides the fundamental information on the phonon subsystem, but also sheds some light in understanding the topological nodal-line phase in ZrSiS and other isostructural systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗