Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Evaluation of a Magneto-optical Filter and a Fabry-perot Interferometer for the Measurement of Solar Velocity Fields from Space

A program was developed to evaluate the performance of three different devices as possible space-borne solar velocity field imagers. Two of these three devices, a magneto-optical filter and a molecular adherence Fabry-Perot interferometer were installed in a newly-constructed observing system located at the 60-foot tower telescope at the Mt. Wilson Observatory. Time series of solar filtergrams and Dopplergrams lasting up to 10 hours per day were obtained with the filter while shorter runs were obtained with the Fabry-Perot. Two-dimensional k (sub h)-omega power spectra which show clearly the well-known p-mode ridges were computed from the time series obtained with the magneto-optical filter. These power spectra were compared with similar power spectra obtained recently with the 13.7-m McMath spectrograph at Kitt Peak.

Rhodes, E. J., Jr.↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Sagnac rotational phase shifts in a mesoscopic electron interferometer with spin-orbit interactions

The Sagnac effect is an important phase coherent effect in optical and atom interferometers where rotations of the interferometer with respect to an inertial reference frame result in a shift in the interference pattern proportional to the rotation rate. Here, we analyze the Sagnac effect in a mesoscopic semiconductor electron interferometer. We include in our analysis the Rashba spin-orbit interactions in the ring. Our results indicate that spin-orbit interactions increase the rotation-induced phase shift. We discuss the potential experimental observability of the Sagnac phase shift in such mesoscopic systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum Interferometry

Recently, several researchers, including yours truly, have been able to demonstrate theoretically that quantum photon entanglement has the potential to also revolutionize the entire field of optical interferometry, by providing many orders of magnitude improvement in interferometer sensitivity. The quantum entangled photon interferometer approach is very general and applies to many types of interferometers. In particular, without nonlocal entanglement, a generic classical interferometer has a statistical-sampling shot-noise limited sensitivity that scales like 1/Sqrt[N], where N is the number of particles (photons, electrons, atoms, neutrons) passing through the interferometer per unit time. However, if carefully prepared quantum correlations are engineered between the particles, then the interferometer sensitivity improves by a factor of Sqrt[N] (square root of N) to scale like 1/N, which is the limit imposed by the Heisenberg Uncertainty Principle. For optical (laser) interferometers operating at milliwatts of optical power, this quantum sensitivity boost corresponds to an eight-order-of-magnitude improvement of signal to noise. Applications are to tests of General Relativity such as ground and orbiting optical interferometers for gravity wave detection, Laser Interferometer Gravity Observatory (LIGO) and the European Laser Interferometer Space Antenna (LISA), respectively.

Dowling, Jonathan P.↗

LCLS X-ray mirror measurements using a large aperture visible light interferometer

Synchrotron or FEL X-ray mirrors are required to deliver an X-ray beam from its source to an experiment location, without contributing significantly to wave front distortion. Accurate mirror figure measurements are required prior to installation to meet this intent. This paper describes how a 300 mm aperture phasing interferometer was calibrated to <1 nm absolute accuracy and used to mount and measure 450 mm long flats for the Linear Coherent Light Source (LCLS) at Stanford Linear Accelerator Center. Measuring focus mirrors with an interferometer requires additional calibration, because high fringe density introduces systematic errors from the interferometer's imaging optics. This paper describes how these errors can be measured and corrected. The calibration approaches described here apply equally well to interferometers larger than 300 mm aperture, which are becoming more common in optics laboratories. The objective of this effort was to install LCLS flats with < 10 nm of spherical curvature, and < 2 nm rms a-sphere. The objective was met by measuring the mirrors after fabrication, coating and mounting, using a 300 mm aperture phasing interferometer calibrated to an accuracy < 1 nm. The key to calibrating the interferometer accurately was to sample the error using independent geometries that are available. The results of those measurements helped identify and reduce calibration error sources. The approach used to measure flats applies equally well to focus mirrors, provided an additional calibration is performed to measure the error introduced by fringe density. This calibration has been performed on the 300 mm aperture interferometer, and the measurement correction was evaluated for a typical focus mirror. The 300 mm aperture limitation requires stitching figure measurements together for many X-ray mirrors of interest, introducing another possible error source. Stitching is eliminated by applying the calibrations described above to larger aperture instruments. The authors are presently extending this work to a 600 mm instrument. Instruments with 900 mm aperture are now becoming available, which would accommodate the largest mirrors of interest.

43 PARTICLE ACCELERATORS↗

Interferometric adaptive optics for high-power laser beam correction in fast ignition experiments

We present the design for a high-speed adaptive optics system that will be used to achieve the necessary laser pointing and beam-quality performance for initial fast-ignition coupling experiments. This design makes use of a 32 x 32 pixellated MEMS device as the adaptive optic and a two-channel interferometer as the wave-front sensor. We present results from a system testbed that demonstrates improvement of the Strehl ratio from 0.09 to 0.61 and stabilization of beam pointing from {approx}75{micro}rad to <2{micro}rad.

42 ENGINEERING↗

Optics Alignment of a Balloon-Borne Far-Infrared Interferometer BETTII

The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-m baseline far-infrared (FIR: 30 90 micrometer) interferometer providing spatially resolved spectroscopy. The initial scientific focus of BETTII is on clustered star formation, but this capability likely has a much broader scientific application.One critical step in developing an interferometer, such as BETTII, is the optical alignment of the system. We discuss how we determine alignment sensitivities of different optical elements on the interferogram outputs. Accordingly, an alignment plan is executed that makes use of a laser tracker and theodolites for precise optical metrology of both the large external optics and the small optics inside the cryostat. We test our alignment on the ground by pointing BETTII to bright near-infrared sources and obtaining their images in the tracking detectors.

Dhabal, Arnab↗

Two improved coherent optical feedback systems for optical information processing

Coherent optical feedback systems are Fabry-Perot interferometers modified to perform optical information processing. Two new systems based on plane parallel and confocal Fabry-Perot interferometers are introduced. The plane parallel system can be used for contrast control, intensity level selection, and image thresholding. The confocal system can be used for image restoration and solving partial differential equations. These devices are simpler and less expensive than previous systems. Experimental results are presented to demonstrate their potential for optical information processing.

Lee, S. H.↗

Far infrared interferometer technology development: a progress report

We report on the progress of developing a cryogenic delay line and integrated optics components. These are some of the critical components needed to enable farm, direct detection, interferometers. To achieve background limited performance in the 40 to 400 pm region, the interferometer optics and delay line must be cooled to near liquid Helium temperatures. The cryogenic delay line design incorporates a number of novel features and has been tested and characterized at liquid nitrogen temperatures. The integrated optics effort has focused on producing single mode spatial filters and beam combiners.

Interferometer↗

Inspection of commercial optical devices for data storage using a three Gaussian beam microscope interferometer

Recently, an interferometric profilometer based on the heterodyning of three Gaussian beams has been reported. This microscope interferometer, called a three Gaussian beam interferometer, has been used to profile high quality optical surfaces that exhibit constant reflectivity with high vertical resolution and lateral resolution near {lambda}. We report the use of this interferometer to measure the profiles of two commercially available optical surfaces for data storage, namely, the compact disk (CD-R) and the digital versatile disk (DVD-R). We include experimental results from a one-dimensional radial scan of these devices without data marks. The measurements are taken by placing the devices with the polycarbonate surface facing the probe beam of the interferometer. This microscope interferometer is unique when compared with other optical measuring instruments because it uses narrowband detection, filters out undesirable noisy signals, and because the amplitude of the output voltage signal is basically proportional to the local vertical height of the surface under test, thus detecting with high sensitivity. We show that the resulting profiles, measured with this interferometer across the polycarbonate layer, provide valuable information about the track profiles, making this interferometer a suitable tool for quality control of surface storage devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical layout and mechanical structure of polarimeter-interferometer system for Experimental Advanced Superconducting Tokamak

A Far-InfaRed (FIR) three-wave POlarimeter-INTerferometer (POINT) system for measurement current density profile and electron density profile is under development for the EAST tokamak. The FIR beams are transmitted from the laser room to the optical tower adjacent to EAST via ∼20 m overmoded dielectric waveguide and then divided into 5 horizontal chords. The optical arrangement was designed using ZEMAX, which provides information on the beam spot size and energy distribution throughout the optical system. ZEMAX calculations used to optimize the optical layout design are combined with the mechanical design from CATIA, providing a 3D visualization of the entire POINT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Achromatic digital speckle pattern interferometer with constant radial in-plane sensitivity by using a diffractive optical element

We report on a digital speckle pattern interferometer that applies a binary diffractive optical element (DOE) to generate double illumination and radial in-plane sensitivity. The application of the DOE ensures independence on the wavelength of the laser used as an illumination source. Furthermore, in-plane sensitivity only depends on the grating period of the DOE. An experimental setup was built allowing the measurement of a set of radial in-plane displacement fields either using a red laser as a light source or a green one. When displacement fields computed from the measured optical phase maps obtained with a red or a green laser were compared, two main results were observed: (a) deviations between mean values ranged only up to 7 nm and (b) phase maps presented the same amount of fringes. In addition, phase maps measured with the red laser were processed as they were obtained with green light. For this case, deviations have ranged only up to 0.5 nm. On the other hand, a set of measurements performed changing the DOE by a conical mirror showed clearly that radial in-plane sensitivity increased when the red laser was changed by the green one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Excess noise reduction by optical technique in amplitude-sensitive heterodyne interferometer for small differential phase detection

An amplitude-sensitive technique associated with a heterodyne interferometer for detecting small differential phase is reported. The excess noise with the amplitude-sensitive technique is reduced by optical subtraction instead of electronic subtraction. The differential phase introduced by the orthogonally polarized laser beams is converted to the amplitudes of two heterodyne interferometric signals, which presents amplitude and phase quadrature simultaneously. Thus the excess noise power and quantum noise power are both differential phase dependent. The advantages of differential and additive operations by optical technique and the real time differential phase determination without phase lock in are demonstrated experimentally. The theoretical signal-to-noise ratio (SNR) and minimum detectable differential phase are derived, which takes quantum noise and excess noise into consideration. The experimental results demonstrated the resolutions of differential phase detection closes to 10{sup -6} rad/{radical}Hz (10{sup -13} m/{radical}Hz) level over 100 kHz bandwidth and at 10{sup -8} rad/{radical}Hz (10{sup -15} m/{radical}Hz) level over 125 MHz bandwidth, respectively, under 2.5 mW incident power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electro-refractive photonic device

The various technologies presented herein relate to phase shifting light to facilitate any of light switching, modulation, amplification, etc. Structures are presented where a second layer is juxtaposed between a first layer and a third layer with respective doping facilitating formation of p-n junctions at the interface between the first layer and the second layer, and between the second layer and the third layer. Application of a bias causes a carrier concentration change to occur at the p-n junctions which causes a shift in the effective refractive index per incremental change in an applied bias voltage. The effective refractive index enhancement can occur in both reverse bias and forward bias. The structure can be incorporated into a waveguide, an optical resonator, a vertical junction device, a horizontal junction device, a Mach-Zehnder interferometer, a tuneable optical filter, etc.

36 MATERIALS SCIENCE↗

A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer

While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this study, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ~2.9 km/s. Finally, sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

47 OTHER INSTRUMENTATION↗

Radius of Curvature Measurement of Large Optics Using Interferometry and Laser Tracker

The determination of radius of curvature (ROC) of optics typically uses either a phase measuring interferometer on an adjustable stage to determine the position of the ROC and the optics surface under test. Alternatively, a spherometer or a profilometer are used for this measurement. The difficulty of this approach is that for large optics, translation of the interferometer or optic under test is problematic because of the distance of translation required and the mass of the optic. Profilometry and spherometry are alternative techniques that can work, but require a profilometer or a measurement of subapertures of the optic. The proposed approach allows a measurement of the optic figure simultaneous with the full aperture radius of curvature.

Hagopian, John↗

Steps Toward a Large Space-Based UV/Optical Fizeau Interferometer: The GSFC Fizeau Interferometer Testbed (FIT)

Goddard Space Flight Center is pursuing the development of space-based, long-baseline (0.5km) UV-optical Fizeau imaging interferometers to enable the next major stride toward very high angular resolution astronomical observations. This effort includes the development and operation of the Fizeau Interferometry Testbed (FIT), in collaboration with the Naval Research Lab/NPOI, Univ. of MD, and Sigma Space Corporation. The FIT will be used to explore the principles of and requirements for the Stellar Imager (SI) mission concept (http://hires.gsfc.nasa.gov/~si) and other such Fizeau Interferometers/Sparse Aperture Telescope missions, leading in the end to the Planet Imager (PI), which is the ultimate goal of the current Origins Program. The primary goal of the FIT program is to demonstrate closed-loop control of mirrors (tip, tilt, piston, translation of array elements) and the overall system to keep the optical beams in phase and enable high quality imaging by a many-element (7-30) Fizeau Interferometric System. The FIT will also be used to assess various wave-front reconstruction and sensing and image reconstruction algorithms for utility and accuracy by application to real data generated by the Testbed. In this paper, we describe the design and goals of the system, provide a status report on its construction, and note our future plans.

Carpenter, K. G.↗

Surface Profile and Stress Field Evaluation using Digital Gradient Sensing Method

Shape and surface topography evaluation from measured orthogonal slope/gradient data is of considerable engineering significance since many full-field optical sensors and interferometers readily output accurate data of that kind. This has applications ranging from metrology of optical and electronic elements (lenses, silicon wafers, thin film coatings), surface profile estimation, wave front and shape reconstruction, to name a few. In this context, a new methodology for surface profile and stress field determination based on a recently introduced non-contact, full-field optical method called digital gradient sensing (DGS) capable of measuring small angular deflections of light rays coupled with a robust finite-difference-based least-squares integration (HFLI) scheme in the Southwell configuration is advanced here. The method is demonstrated by evaluating (a) surface profiles of mechanically warped silicon wafers and (b) stress gradients near growing cracks in planar phase objects.

42 ENGINEERING↗