Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗

A Possible X-Ray and Radio Counterpart of the High-Energy Gamma-Ray Source 3EG J2227+6122

The identity of the persistent EGRET sources in the Galactic plane is largely a mystery. For one of these, 3EG J2227+6122, our complete census of X-ray and radio sources in its error circle reveals a remarkable superposition of an incomplete radio shell with a flat radio spectrum, and a compact, power-law X-ray source with photon index Gamma = 1.5 and with no obvious optical counterpart. The radio shell is polarized at a level of approx. = 25%. The anomalous properties of the radio source prevent us from deriving a completely satisfactory theory as to its nature. Nevertheless, using data from ROSAT, ASCA, the VLA, and optical imaging and spectroscopy, we argue that the X-ray source may be a young pulsar with an associated wind-blown bubble or bow shock nebula, and an example of the class of radio-quiet pulsars which are hypothesized to comprise the majority of EGRET sources in the Galaxy. The distance to this source can be estimated from its X-ray absorption as 3 kpc. At this distance, the X-ray and gamma-ray luminosities would be approx. = 1.7 x 10(exp 33) and approx. = 3.7 x 10(exp 35) erg/s, respectively, which would require an energetic pulsar to power them. If, on the contrary, this X-ray source is not the counterpart of 3EG J2227+6122, then by process of elimination the X-ray luminosity of the latter must be less than 10(exp -4) of its gamma-ray luminosity, a condition not satisfied by any established class of gamma-ray source counterpart. This would require the existence of at least a quantitatively new type of EGRET source, as has been suggested in studies of other EGRET fields.

Halpern, Jules P.↗

Near-Infrared Monitoring of Model Chronic Compartment Syndrome In Exercising Skeletal Muscle

Chronic compartment syndrome (CCS) is characterized by muscle ischemia, usually in the anterior oompartment of the leg, caused by high intramuscular pressure during exercise. Dual-wave near-infrared (NIR) spectroscopy is an optical technique that allows noninvasive tracking of variations in muscle tissue oxygenation (Chance et al., 1988). We hypothesized that with a model CCS, muscle tissue oxygenation will show a greater decline during exercise and a slower recovery post-exercise than under normal conditions.

Hargens, Alan R.↗

Broad-Band Continuum and Line Emission of the gamma-Ray Blazar PKS 0537-441

PKS 0537-441, a bright gamma ray emitting blazar was observed at radio, optical, UV and X-ray frequencies during various EGRET paintings, often quasi-simultaneously. In 1995 the object was found in an intense emission state at all wavelengths. BeppoSAX observations made in 1998, non-simultaneously with exposures at other frequencies, allow us to characterize precisely the spectral shape of the high energy blazer component, which we attribute to inverse Compton scatter in The optical-to-gamma-ray spectral energy distributions at the different epochs show that the gamma-ray luminosity dominates the barometric output. This, together with the presence of optical and UV line emission, suggests that, besides the synchrotron self-Compton mechanism, the Compton upscattering of photons external to the jet (e.g., in the broad line region) may have a significant role for high energy radiation. The multiwavelength variability can be reproduced by changes of the plasma bulk Lorentz factor. The spectrum secured by ICE in 1995 appears to be partially absorbed shortward of approximately 1700 Angstroms. However, this signature is not detected in the HST spectrum taker during a lower state of the source. The presence of intervening absorbers is not supported by optical imaging and spectroscopy of the field.

Pian, E.↗

B-MINE: The Balloon-Borne Microcalorimeter Nuclear Line Explorer

B-MINE is a concept for a balloon mission designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the extent and velocity distribution of the 44Ti emitting region. The payload introduces the concept of focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics. B-MINE has a thin, plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3 sigma sensitivity in 10 (exp 6) s of 3.3 x 10(exp -7) ph cm(exp -2) s(exp -1) at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroid and width in CAS A.

Silver, E.↗

Coronal Activity in the R CrA T Association

For this project we intend to extract net counts and variability information for the X-ray sources found in 9 archival ROSAT PSPC and 6 archival ROSAT HRI images in the region of the R CrA T association. These data will be merged with an extensive database of optical photometry and spectroscopy plus published near-infrared photometry to (1) identify new association members and (2) derive, for the first time, an accurate coronal luminosity function for the T Tauri members of this T association. These data will be used to make direct comparisons between the coronal luminosity functions for other T associations and those of large clusters to assess (a) the importance of the star-formation environment in initial coronal activity levels, (b) the effects of PMS evolution on dynamo activity as a function of mass and age, and (c) the level of contamination by field post-T Tauri stars on association membership surveys.

Patten, Brian M.↗

Using the Chandra Project to Communicate with Underdeveloped Constituencies

We have instituted a program whose goal is to better communicate astronomy among students selected from an economically underprivileged area of Huntsville, Alabama. To achieve this goal, six local teachers were trained as astronomy teacher resource agents. These teachers were teamed with six scientists; the teams presented materials for 29 teachers, mostly from the Southeastern United States Topics included the electromagnetic spectrum, X-ray optics, gratings and spectroscopy, supernovae (and remnants), black holes, and the tools and techniques to analyze Chandra X-ray data. Beginning in September our teacher-scientist teams, in collaboration with the Huntsville Housting Authority, will present programs to specially selected students at the rate of one or two per month, until April 2004. These young people will be mentored and encouraged to develop a research project. Students, which complete a project by April 2, will be paid for their work.

Adams, M. L.↗

Huygens Probe Relay Data Subsystem Anomaly and Recovery

European Space Agency Mission is designed to study the atmosphere and surface of Saturn's largest satellite, Titan carried by the Cassini spacecraft which provides: a) Power for support equipment; b) S-band antenna system; and c) Data storage and playback. Instruments/investigations include: 1) Aerosol Collector Pyrolyzer (ACP). Study of clouds and aerosols in the Titan atmosphere. 2) Descent Imager and Spectral Radiometer (DISR). Aerosol and cloud optical properties and spectroscopy measurements of Titan's atmosphere and surface. 3) Doppler Wind Experiment (DWE). Study of winds from their effect on the Probe during Titan descent. 4) Gas Chromatograph and Mass Spectrometer (GCMS). Chemical composition of gases and aerosols in Titan's atmosphere. 5) Huygens Atmospheric Structure Instrument (HASI). In-situ study of Titan atmospheric physical and electrical properties. 6) Surface Science Package (SSP). Physical properties of Titan's surface and related atmospheric properties.

Huygens↗

Synthesis, Characterization, Topographical Modification, and Surface Properties of Copoly(Imide Siloxane)s

Novel copoly(imide siloxane)s were synthesized from commercially available aminopropyl terminated siloxane oligomers, aromatic dianhydrides, and diamines. This synthetic approach produced copolymers with well-defined siloxane blocks linked with imide units in a random fashion. The copoly(amide acid)s were characterized by solution viscosity and subsequently used to cast thin films followed by thermal imidization in an inert atmosphere. Thin films were characterized using contact angle goniometry, attenuated total reflection Fourier transform infrared spectroscopy, confocal and optical microscopy, and tensile testing. Adhesion of micronsized particles was determined quantitatively using a sonication device. The polydimethylsiloxane (PDMS) moieties lowered the copolymer surface energy due to migration of siloxane moieties to the film s surface, resulting in a notable reduction in particle adhesion. A further reduction in particle adhesion was achieved by introducing topographical features on a scale of several to tens of microns by a laser ablation technique.

Wohl, Christopher J.↗

Surface Monitoring of CFRP Structures for Adhesive Bonding

Adhesive bonding of composite materials requires reliable monitoring and detection of surface contaminants to assure robust and durable bonded structures. Surface treatment and effective monitoring prior to bonding is essential in order to obtain a surface free from contaminants that may degrade structural performance. Two techniques which monitor the effectiveness of the laser surface treatment of carbon fiber reinforced polymer (CFRP) materials are being investigated: laser induced breakdown spectroscopy (LIBS) and optically stimulated electron emission (OSEE). The applicability of LIBS to detect silicone contaminants on CFRP composites is studied using ~35 ns Nd:YAG laser pulses at 355 nm with a pulse energy of 45 mJ. The LIBS regime in which pulse energies are < 100 mJ is referred to as mLIBS. CFRP surfaces were contaminated with polydimethylsiloxane (PDMS), a major component of silicone based mold release agents. The presence of PDMS is found by inspecting the Si I emission line at 288.2 nm. Untreated CFRP samples and CFRP contaminated with PDMS were tested. The PDMS areal density ranged from 0.36 Â+/- 0.04 to 0.51 Â+/- 0.16 mg/cm2. The results demonstrate the successful detection of PDMS on CFRP using mLIBS. In addition, OSEE was used to measure CFRP surface cleanliness pre- and post-treatment by laser ablation on specimens contaminated with PDMS coatings from 8 nm to 1311 nm in thickness. The results showed a significant increase in the OSEE photocurrent after laser surface treatment.

Ledesma, Rodolfo↗

Analysis of Hypervelocity-Impacted Thin Films for Space Applications

Exposure to the harsh space environment and hypervelocity impacts from micrometeoroids and small orbital debris can affect space operations through long-term degradation of spacecraft materials, surfaces, or systems. Multi-layer insulation (MLI) and coated, polyimide films are spacecraft materials commonly found on the external surfaces of spacecraft for thermal control and protection. Characterizing the damage to these exposed materials with in situ and laboratory measurements can better inform spacecraft designers and operators in understanding and mitigating surface or system degradation. In this paper, we examine flown Hubble Space Telescope (HST) Equipment Bay 5 MLI and coated, polyimide ground test articles to characterize hypervelocity impact damage. Impact feature cavities are inspected to identify damage, which can validate long-term degradation models, improve thermal management systems, or improve accuracy of damage predictions. An overview of the impact characterization using optical microscopy, narrowband spectroscopy, and Scanning Election Microscopy/Energy Dispersive X- ray (SEM/EDX) of the two materials is presented. Observations of robustness in the space environment, as well as a detailed assessment of cratering and penetration statistics for the space-exposed sample, also are discussed.

Melissa A. Ward↗

The NEID Port Adapter at WIYN: On-Sky Fast Guiding Performance

NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy) is an optical, fiber-fed spectrometer installed on the WIYN 3.5m Telescope. The radial velocity precision that NEID is expected to reach requires the stellar jitter (i.e., the slight irregular movement of the stellar image induced by atmospheric turbulence, wind-shake, etc.) to be controlled within 0.05 arc-seconds 90% of the time in nominal observing conditions (i.e., 0.8-arcsecond seeing and mild winds). To achieve that, the NEID Port Adapter incorporates a fast, first-order wavefront correction system, which implements an Electron-Multiplying CCD camera and a tip/tilt piezo stage to capture and stabilize the stellar image. Here, we use on-sky data to demonstrate the performance of this system under various observing conditions.

Dan Li↗

Spatial heterodyne spectroscopy - A novel interferometric technique for the FUV

The optical principles associated with spatial heterodyne spectroscopy (SHS) are described and the results of proof-of-concept tests performed in both the visible and the UV spectral regions are presented. A specific all-reflecting SHS configuration now being developed for high-resolution planetary Lyman-alpha studies is discussed. The expected performance of SHS systems is compared to that of conventional instrumentation in two cases: Venusian Ly-alpha measurements at high resolution from a sounding rocket and the velocity-resolved survey of the diffuse FUV interstellar medium emission from a Small Explorer class satellite.

Harlander, J.↗

Miniature instrumentation for laser light scattering experiments

Traditional optical systems for photon correlation spectroscopy and laser anemometry have relied upon physically large and fairly expensive lasers, bulk-optics such as lenses of a few inches diameter, large mechanical mounts and carefully selected, fragile and bulky photon counting photomultiplier detectors. In some cases, experimental fluid dynamics at a desired position in a flow, perhaps deep inside complex machinery, is physically impossible or very difficult. Similar problems exist with photon correlation spectroscopy, e.g., remote and heterodyne experiments. Various optical and electro optical components were investigated and characterized with the aim of replacing existing photon correlation laser spectroscopy and anemometry techniques in miniaturized form, and with significant cost reduction. Very recently, a range of miniature, modular light scattering systems were constructed from little solid state optical and electro optical components, and experimentally verified measurement performance comparable to standard lab photon correlation spectroscopy and laser anemometry equipment.

Brown, Robert G. W.↗

High-Efficiency Flexible Multilevel Photon Sieves by Single-Step Laser-Based Fabrication and Optical Analysis

Over the past several decades, the need for high-resolution, high-efficiency, lightweight, high contrast focusing optics has continued to increase due to their applications in fields such as astronomy, spectroscopy, free-space optical communications, defense, and remote sensing. In recent years, photon sieve planar diffractive optics have been developed on flexible, lightweight polyimide substrates. However, transmission efficiencies have continuously been very low (~1-4%), thus impeding the widespread use of photon sieves in practical applications. Here, we present a flexible, lightweight, N = 4 level phase photon sieve with over 25% transmission efficiency; nearly triple that of any other photon sieve reported thus far. In this study, the photon sieve was fabricated via a novel pulsed laser ablation method using an ultraviolet source, and the total time to fabricate a ~3 sq cm sample was tens of seconds. Theoretical analysis of the photon sieve was carried out via the FDTD method, and was in very good agreement with experimental results. We also calculated via FDTD modeling the behavior of higher step (N = 8, 16, 32) photon sieves for further enhanced efficiencies, and show a fundamental limit on photon sieve efficiency of 70% in the limit of increasing step number. This multilevel photon sieve represents a new step in high-resolution diffractive optics, moving towards efficiencies suitable for widespread applications.

Julian, Matthew N.↗

Coronagraphic Methods for the Detection of Terrestrial Planets

I will contribute (i.e. join in writing the TPF-C Report) for the following workshop topics: 1) Science Topics (target list): I describe a new target list for the TPF-C based on General TPF target list maintained at the US Naval Observatory; 2) Science Topics (spectroscopy): I describe the need for optical, imaging, pulse-counting detectors for spectroscopy of terrestrial planets; 3) Simulation and Modeling Techniques: I describe work at Goddard Space Flight Center to simulate wide-band imagery and spectroscopic imagery that will be obtained by TPF-C.

Heap, Sally↗