Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter continuation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Designing the Protocols for Programmable Ammonia Catalysis

Programmable catalysis can provide a more energy-efficient and cost-effective route to enhancing commercial ammonia production, a key process in the advancement of renewable energy technologies and the manufacture of fertilizers and basic chemicals. This work explores the computational discovery of optimal forcing protocols to drive such dynamic catalysis models. By employing matrix-free time-stepper methods, coupled with an optimization approach, that integrates Bayesian optimization with a Bayesian continuation strategy to efficiently discover the periodic steady states of such periodically forced systems, we enable the discovery of complex optimal catalyst strain waveforms, while ensuring robust solver convergence. We demonstrate the flexibility of our approach to discover optimized forcing protocols under varying physical constraints on strain modulation or other catalyst operating parameters. We show that these can have a temporal structure more complex than simple step functions. In order to detect undesirable catalytic loops that may correlate with overall reduced performance, we perform a study using graph-theoretical analysis to investigate the dynamics of catalytic kinetic networks formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal pulse sequence modifications and no additional scan time, improving ASL’s clinical applicability.

60 APPLIED LIFE SCIENCES↗

Generation of polarization entanglement via the quantum Zeno effect

The quantum Zeno effect reveals that continuous observation of a quantum system can significantly alter its evolution. Here, we present a method for establishing polarization entanglement between two initially unentangled photons in coupled waveguides via the quantum Zeno effect. We support our analytical investigation with numerical simulations of the underlying Schrodinger equation describing the system. Further, we extend our technique to three coupled waveguides in a planar configuration and determine the parameters required to generate three-qubit W-states. In contrast to existing schemes based on a vacuum and single-photon encoding, the polarization encoding in our approach is compatible with quantum information protocols that remove photon loss through post-selection. Our findings offer a powerful quantum state engineering approach for photonic quantum information technologies.

Nodurft, Ian C.↗

The National Energy Technology Laboratory’s New Unit Process Template Design - LCAXIX

This work was presented at the American Center for Life Cycle Assessment 2019 Conference (LCAXIX) in Tucson, AZ on September 25, 2019. The National Energy Technology Laboratory (NETL) maintains a large unit process (UP) library which holds all documentation for each unit process created by the NETL Life Cycle Analysis (LCA) team. Each NETL unit process includes a Microsoft Excel spreadsheet containing calculations and an accompanying PDF, which thoroughly documents the calculations, parameters, and underlying reasoning and assumptions contained in the Excel file. However, as more and larger public data sources become available, the NETL LCA team has incorporated more data science techniques into their unit process development. NETL is demonstrating a new template which will allow for more flexible and advanced calculation and documentation methods. The new template will support NETL’s dedication to transparency by continuing to provide all information necessary to replicate the UPs.

Krynock, Michelle↗

TH-C-18A-09: Exam and Patient Parameters Affecting the DNA Damage Response Following CT Studies

Purpose: To identify exam and patient parameters affecting the biological response to CT studies using in vivo and ex vivo blood samples. Methods: Blood samples were collected under IRB approval from 16 patients undergoing clinically-indicated CT exams. Blood was procured prior to, immediately after and 30minutes following irradiation. A sample of preexam blood was placed on the patient within the exam region for ex vivo analysis. Whole blood samples were fixed immediately following collection and stained for γH2AX to assess DNA damage response (DDR). Median fluorescence of treated samples was compared to non-irradiated control samples for each patient. Patients were characterized by observed biological kinetic response: (a) fast — phosphorylation increased by 2minutes and fell by 30minutes, (b) slow — phosphorylation continued to increase to 30minutes and (c) none — little change was observed or irradiated samples fell below controls. Total dose values were normalized to exam time for an averaged dose-rate in dose/sec for each exam. Relationships between patient biological responses and patient and exam parameters were investigated. Results: A clearer dose response at 30minutes is observed for young patients (<61yoa; R2>0.5) compared to old patients (>61yoa; R{sup 2}<0.11). Fast responding patients were significantly younger than slow responding patients (p<0.05). Unlike in vivo samples, age did not significantly affect the patient response ex vivo. Additionally, fast responding patients received exams with significantly smaller dose-rate than slow responding patients (p<0.05). Conclusion: Age is a significant factor in the biological response suggesting that DDR may be more rapid in a younger population and slower as the population ages. Lack of an agerelated response ex vivo suggests a systemic response to radiation not present when irradiated outside the body. Dose-rate affects the biological response suggesting that patient response may be related to scan timing and dose delivery within an exam protocol. All authors receive(d) funding from a Master Research Agreement from Siemens Healthcare with UCLA Radiological Sciences.

60 APPLIED LIFE SCIENCES↗

SU-E-T-295: Simultaneous Beam Sampling and Aperture Shape Optimization for Station Parameter Optimized Radiation Therapy (SPORT)

Purpose: Station Parameter Optimized Radiation Therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital LINACs, in which the station parameters of a delivery system, (such as aperture shape and weight, couch position/angle, gantry/collimator angle) are optimized altogether. SPORT promises to deliver unprecedented radiation dose distributions efficiently, yet there does not exist any optimization algorithm to implement it. The purpose of this work is to propose an optimization algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: We build a mathematical model whose variables are beam angles (including non-coplanar and/or even nonisocentric beams) and aperture shapes. To solve the resulting large scale optimization problem, we devise an exact, convergent and fast optimization algorithm by integrating three advanced optimization techniques named column generation, gradient method, and pattern search. Column generation is used to find a good set of aperture shapes as an initial solution by adding apertures sequentially. Then we apply the gradient method to iteratively improve the current solution by reshaping the aperture shapes and updating the beam angles toward the gradient. Algorithm continues by pattern search method to explore the part of the search space that cannot be reached by the gradient method. Results: The proposed technique is applied to a series of patient cases and significantly improves the plan quality. In a head-and-neck case, for example, the left parotid gland mean-dose, brainstem max-dose, spinal cord max-dose, and mandible mean-dose are reduced by 10%, 7%, 24% and 12% respectively, compared to the conventional VMAT plan while maintaining the same PTV coverage. Conclusion: Combined use of column generation, gradient search and pattern search algorithms provide an effective way to optimize simultaneously the large collection of station parameters and significantly improves quality of resultant treatment plans as compared with conventional VMAT or IMRT treatments.

07 ISOTOPE AND RADIATION SOURCES↗

Latent-space time evolution of non-intrusive reduced-order models using Gaussian process emulation

Non-intrusive reduced-order models (ROMs) have recently generated considerable interest for constructing computationally efficient counterparts of nonlinear dynamical systems emerging from various domain sciences. They provide a low-dimensional emulation framework for systems that may be intrinsically high-dimensional. This is accomplished by utilizing a construction algorithm that is purely data-driven. It is no surprise, therefore, that the algorithmic advances of machine learning have led to non-intrusive ROMs with greater accuracy and computational gains. However, in bypassing the utilization of an equation-based evolution, it is often seen that the interpretability of the ROM framework suffers. This becomes more problematic when black-box deep learning methods are used which are notorious for lacking robustness outside the physical regime of the observed data. In this article, we propose the use of a novel latent-space interpolation algorithm based on Gaussian process regression. Notably, this reduced-order evolution of the system is parameterized by control parameters to allow for interpolation in space. The use of this procedure also allows for a continuous interpretation of time which allows for temporal interpolation. The latter aspect provides information, with quantified uncertainty, about full-state evolution at a finer resolution than that utilized for training the ROMs. This research assesses the viability of this algorithm for an advection-dominated system given by the inviscid shallow water equations.

97 MATHEMATICS AND COMPUTING↗

Calibration of a distributed flood forecasting model with input uncertainty using a Bayesian framework

In the process of calibrating distributed hydrological models, accounting for input uncertainty is important, yet challenging. In this study, we develop a Bayesian model to estimate parameters associated with a geomorphology‐based hydrological model (GBHM). The GBHM model uses geomorphic characteristics to simplify model structure and physically based methods to represent hydrological processes. We divide the observed discharge into low‐ and high‐flow data, and use the first‐order autoregressive model to describe their temporal dependence. We consider relative errors in rainfall as spatially distributed variables and estimate them jointly with the GBHM parameters. The joint posterior probability distribution is explored using Markov chain Monte Carlo methods, which include Metropolis‐Hastings, delay rejection adaptive Metropolis, and Gibbs sampling methods. We evaluate the Bayesian model using both synthetic and field data sets. The synthetic case study demonstrates that the developed method generally is effective in calibrating GBHM parameters and in estimating their associated uncertainty. The calibration ignoring input errors has lower accuracy and lower reliability compared to the calibration that includes estimation of the input errors, especially under model structure uncertainty. The field case study shows that calibration of GBHM parameters under complex field conditions remains a challenge. Although jointly estimating input errors and GBHM parameters improves the continuous ranked probability score and the consistency of the predictive distribution with the observed data, the improvement is incremental. To better calibrate parameters in a distributed model, such as GBHM here, we need to develop a more complex model and incorporate much more information.

54 ENVIRONMENTAL SCIENCES↗

Illusion optics: Optically transforming the nature and the location of electromagnetic emissions

Complex electromagnetic structures can be designed by using the powerful concept of transformation electromagnetics. In this study, we define a spatial coordinate transformation that shows the possibility of designing a device capable of producing an illusion on an antenna radiation pattern. Indeed, by compressing the space containing a radiating element, we show that it is able to change the radiation pattern and to make the radiation location appear outside the latter space. Both continuous and discretized models with calculated electromagnetic parameter values are presented. A reduction of the electromagnetic material parameters is also proposed for a possible physical fabrication of the device with achievable values of permittivity and permeability that can be obtained from existing well-known metamaterials. Following that, the design of the proposed antenna using a layered metamaterial is presented. Full wave numerical simulations using Finite Element Method are performed to demonstrate the performances of such a device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-wavelength generation of picosecond pulses with 9.8 GHz repetition rate in Nd : YAG waveguide laser with graphene

We report a new solid-state waveguide laser generating picosecond pulses with a GHz repetition rate, based on the use of graphene as a saturable absorber. Lasing at the main transverse mode is provided by the geometry of a cylindrical waveguide formed in the active crystal volume by the method of direct writing with a femtosecond laser beam. Fine tuning of the intracavity interferometer formed between the active medium and output mirror makes it possible to control the spectral-temporal parameters of output radiation and to smoothly tune the repetition rate of pulses having a duration of less than 20 ps. In particular, the possibility of dual-wavelength generation in the regime of continuous passive mode locking using a single saturable absorber based on graphene is demonstrated. By amplifying laser output radiation in the ytterbium fibre amplifier, an average output power of 530 mW is obtained. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First-principles prediction of the Landau parameter for Fermi liquids near the unitarity limit

This paper explores the behavior of systems of cold fermions as they approach unitary above the critical temperature. Symmetry arguments indicate that at unitarity the Fermi-liquid picture breaks down. As we move away from unitarity, by decreasing the scattering length, the dilaton, the Goldstone boson resulting from the spontaneous breaking of Schrodinger symmetry by the Fermi sea, becomes gapped. At energies below this gap, the interaction between quasiparticles will be dominated by dilaton exchange. Here, the dilaton mass can, in turn, be related via anomaly matching to the scattering length and contact parameter within the confines of a systematic expansion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating Lyman- α constraints for general dark-matter velocity distributions: Multiple scales and cautionary tales

One of the most important observational constraints on possible models of dark-matter physics exploits the Lyman-α absorption spectrum associated with photons traversing the intergalactic medium. Because these data allow us to probe the linear matter power spectrum with great accuracy down to relatively small distance scales, finding ways of accurately evaluating such Lyman-α constraints across large classes of candidate models of dark-matter physics is of paramount importance. While such Lyman-α constraints have been evaluated for dark-matter models that give rise to relatively simple dark-matter velocity distributions, more complex models—particularly those whose dark-matter velocity distributions stretch across multiple scales—have recently been receiving increasing attention. In this paper, we undertake a study of the Lyman-α constraints associated with general dark-matter velocity distributions. Although such Lyman-α constraints are difficult to evaluate in principle, in practice there currently exist two classes of methods in the literature through which such constraints can be recast into forms which are easier to evaluate and which therefore allow a more rapid determination of whether a given dark-matter model is ruled in or out. Accordingly, we utilize both of these recasts in order to determine the Lyman-α bounds on different classes of dark-matter velocity distributions. Here we also develop a general method by which the results of these different recasts can be compared. For relatively simple dark-matter velocity distributions, we demonstrate that these two classes of recasts tend to align and give similar results. However, we find that the situation is far more complex for distributions involving multiple velocity scales: while these two classes of recasts continue to yield similar results within certain regions of parameter space, they nevertheless yield dramatically different results within precisely those regions of parameter space which are likely to be phenomenologically relevant. This, then, serves as a cautionary tale regarding the use of such recasts for complex dark-matter velocity distributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinetics of system of emitters and nonequilibrium electromagnetic field

A new step in research into the Dicke model kinetics is proposed on the basis of the Bogolyubov reduced description method. A more precise description of the emitter subsystem and electromagnetic field is considered. New reduced description parameters — emitter energy density and binary correlation functions of electric and magnetic field amplitudes — open the way to investigating non-uniform systems of two-level emitters and nonequilibrium electromagnetic field with its correlation properties. Kinetic equations for such systems have been obtained in terms of electrodynamics of continuous media consisting of two-level emitters. Material equations for corresponding media are analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization performance, fidelity, and cost: SIAM VQE

This dataset contains files storing results from classically-simulated quantum subroutines within a dynamical mean-field theory workflow, and jupyter notebooks processing the data in these files to generate plots. The files store: (1) Results from variational quantum eigensolver (VQE) simulations searching for optimal parameters allowing parametrized quantum circuits to prepare approximations to ground states of different Anderson impurity models (AIMs) (2) Results from simulations of a quantum Lanczos algorithm (QLA) estimating the Lanczos coefficients defining the continued-fraction representation of an (AIM) Green’s function Description: Any file named vqe_gs_results* stores approximations to the ground state and energy of a given AIM estimated using three different methods: (1) Numerical diagonalization (2) Ideal VQE simulation (3) VQE simulation with sampling noise For each VQE simulations metadata about the optimization (optimization results plus number of quantum circuits that would have been executed on real hardware) is also stored. Any file named qla_dos_results* estimations for the Lanczos coefficients defining the Green’s function of an AIM. The stored estimations are achieved using different methods: (1) Numerical Lanczos algorithm from initial states obtained from numerical diagonalization (2) Simulated quantum Lanczos algorithm from initial states prepared from parametrized quantum circuits yielded by corresponding ideal and noisy VQE subroutines. The dataset is used and described in M. Karabin et al., "Quantum solver for single-impurity Anderson models with particle-hole symmetry", Phys. Rev. Research 8, 033066 (2026). DOI: https://doi.org/10.1103/7ys3-tl4l

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Finite element analyses of a linear-accelerator electron gun

Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

43 PARTICLE ACCELERATORS↗

Pulsed-N{sub 2} assisted growth of 5-20 nm thick β-W films

A technique to deposit 5-20 nm thick β-phase W using a 2-second periodic pulse of 1 sccm-N{sub 2} gas on Si(001) and SiN(5 nm)/Si(001) substrates is reported. Resistivity, X-ray photoelectron spectroscopy and X-ray reflectivity were utilized to determine phase, bonding and thickness, respectively. X-ray diffraction patterns were utilized to determine the crystal structure, lattice constant and crystal size using the LeBail method. The flow rate of Nitrogen gas (continuous vs. pulsing) had significant impact upon the crystallinity and formation of β-phase W.

36 MATERIALS SCIENCE↗

QUANTIFYING QUASAR VARIABILITY AS PART OF A GENERAL APPROACH TO CLASSIFYING CONTINUOUSLY VARYING SOURCES

Robust fast methods to classify variable light curves in large sky surveys are becoming increasingly important. While it is relatively straightforward to identify common periodic stars and particular transient events (supernovae, novae, microlensing events), there is no equivalent for non-periodic continuously varying sources (quasars, aperiodic stellar variability). In this paper, we present a fast method for modeling and classifying such sources. We demonstrate the method using approx86, 000 variable sources from the OGLE-II survey of the LMC and approx2700 mid-IR-selected quasar candidates from the OGLE-III survey of the LMC and SMC. We discuss the location of common variability classes in the parameter space of the model. In particular, we show that quasars occupy a distinct region of variability space, providing a simple quantitative approach to the variability selection of quasars.

79 ASTRONOMY AND ASTROPHYSICS↗