Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Atomistic simulation of CdTe solid-liquid coexistence equilibria

Atomistic simulations of CdTe using a Stillinger-Weber (S-W) interatomic potential were undertaken to model the solid-liquid phase equilibria of this important compound semiconductor. Although this potential has been used by others to study liquid CdTe and vapor-liquid interface, it is based on fitting parameters optimized only for the zincblende solid. It has not been fully explored as a potential for solid-liquid phase equilibria until this work. This research reports an accurate determination of the melting temperature, TM=1305K near P=0, the heat of fusion at melting and as a function of temperature up to 1700K, and on the relative phase densities with a particular emphasis on the melting line. The S-W potential for CdTe predicts a liquid with a density slightly less than that of the solid and, hence, the pressure-temperature melting line has a positive slope. The pair correlation structure of the liquid is determined and favorably compared to neutron scattering data. The liquid-solid interface is discussed using density profiles and a short-range order parameter for models having principal orientations along <100>, <110>, and <111> crystallographic directions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

Optimisation of thulium fibre laser parameters with generation of pulses by pump modulation

The formation of relaxation pulses of a thulium fibre laser (λ = 1.9 μm) by modulating the power of a pump erbium fibre laser (λ = 1.55 μm) is studied. A theoretical model is developed to find the dependences of pulse duration and peak power on different cavity parameters. The optimal cavity parameters for achieving the minimal pulse duration are determined. The results are confirmed by experimental development of a laser emitting pulses with a duration shorter than 10 ns, a peak power of 1.8 kW and a repetition rate of 50 kHz. (control of radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure-preserving neural networks for the regularized entropy-based closure of a linear, kinetic, radiative transport equation

The main challenge of large-scale numerical simulation of radiation transport is the high memory and computation time requirements of discretization methods for kinetic equations. In this work, we derive and investigate a neural network-based approximation to the entropy-based closure method to accurately compute the solution of the multi-dimensional moment system with a low memory footprint and competitive computational time. We extend methods developed for the standard entropy-based closure to the regularized entropy-based closures. The main idea is to interpret structure-preserving neural network approximations of the regularized entropy-based closure as a two-stage approximation to the original entropy-based closure. We conduct a numerical analysis of this approximation and investigate optimal parameter choices. Our numerical experiments demonstrate that the method has a much lower memory footprint than traditional methods with competitive computation times and simulation accuracy. The code and all trained networks are provided on GitHub.

entropy closure↗

Nuclear-Reaction-Based Radiation Source For Explosives-And SNM-Detection In Massive Cargo

An automatic, nuclear-reaction-based, few-view transmission radiography method and system concept is presented, that will simultaneously detect small, operationally-relevant quantities of chemical explosives and special nuclear materials (SNM) in objects up to the size of LD-3 aviation containers. Detection of all threat materials is performed via the {sup 11}B(d,n+{gamma}) reaction on thick, isotopically-enriched targets; SNM are primarily detected via Dual Discrete-Energy Radiography (DDER), using 15.11 MeV and 4.43 MeV {sup 12}C{gamma}-rays, whereas explosives are primarily detected via Fast Neutron Resonance Radiography (FNRR), employing the broad-energy neutron spectra produced in a thick {sup 11}B-target. To achieve a reasonable throughput of {approx}20 containers per hour, ns-pulsed deuteron beam of the order of 0.5 mA intensity at energies of 5-7 MeV is required. As a first step towards optimizing parameters and sensitivities of an operational system, the 0 deg. spectra and yields of both {gamma}-rays and neutrons in this reaction have been measured up to E{sub d} = 6.65 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonlocal Kernel Network (NKN): a Stable and Resolution-Independent Deep Neural Network.

Neural operators have recently become popular tools for designing solution maps between function spaces in the form of neural networks. Differently from classical scientific machine learning approaches that learn parameters of a known partial differential equation (PDE) for a single instance of the input parameters at a fixed resolution, neural operators approximate the solution map of a family of PDEs [6, 7]. Despite their success, the uses of neural operators are so far restricted to relatively shallow neural networks and confined to learning hidden governing laws. In this work, we propose a novel nonlocal neural operator, which we refer to as nonlocal kernel network (NKN), that is resolution independent, characterized by deep neural networks, and capable of handling a variety of tasks such as learning governing equations and classifying images. Our NKN stems from the interpretation of the neural network as a discrete nonlocal diffusion reaction equation that, in the limit of infinite layers, is equivalent to a parabolic nonlocal equation, whose stability is analyzed via nonlocal vector calculus. The resemblance with integral forms of neural operators allows NKNs to capture long-range dependencies in the feature space, while the continuous treatment of node-to-node interactions makes NKNs resolution independent. The resemblance with neural ODEs, reinterpreted in a nonlocal sense, and the stable network dynamics between layers allow for generalization of NKN’s optimal parameters from shallow to deep networks. This fact enables the use of shallow-to-deep initialization techniques [8]. Our tests show that NKNs outperform baseline methods in both learning governing equations and image classification tasks and generalize well to different resolutions and depths.

97 MATHEMATICS AND COMPUTING↗

Design and optimization of large area thin-film CdTe detector for radiation therapy imaging applications

Purpose: The authors investigate performance of thin-film cadmium telluride (CdTe) in detecting high-energy (6 MV) x rays. The utilization of this material has become technologically feasible only in recent years due to significant development in large area photovoltaic applications. Methods: The CdTe film is combined with a metal plate, facilitating conversion of incoming photons into secondary electrons. The system modeling is based on the Monte Carlo simulations performed to determine the optimized CdTe layer thickness in combination with various converter materials. Results: The authors establish a range of optimal parameters producing the highest DQE due to energy absorption, as well as signal and noise spatial spreading. The authors also analyze the influence of the patient scatter on image formation for a set of detector configurations. The results of absorbed energy simulation are used in device operation modeling to predict the detector output signal. Finally, the authors verify modeling results experimentally for the lowest considered device thickness. Conclusions: The proposed CdTe-based large area thin-film detector has a potential of becoming an efficient low-cost electronic portal imaging device for radiation therapy applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Reservoir Temperature Estimator (RTEst): A multicomponent geothermometry tool

The Reservoir Temperature Estimator (RTEst) is a multicomponent geothermometry tool for estimating reservoir geochemical parameters including reservoir temperature, CO 2 fugacity, mass of water lost or gained, and a reaction factor. It estimates these parameters and their associated uncertainties by minimizing an objective function that is the weighted sum of squares of the saturation indices of a user-selected set of minerals believed to be equilibrated with the reservoir fluid. RTEst accomplishes these estimates by combining the geochemical modeling capabilities of The Geochemist’s Workbench® with the optimization/parameter estimation resources of PEST®. An included interface aids the user in selecting plausible mineral phases to comprise the objective function and calculates their weighting factors. The working principles of RTEst are described and its efficacy is illustrated by presenting results of its application to various geothermal fields with known conditions. These examples show RTEst can account for the alteration of ascending reservoir fluid by mineral (calcite) re-equilibration with changes in temperature, reconstruct waters with CO 2 loss, correct for the deficit of water and other volatiles (CO 2,gas , H 2 S gas ) from boiling, and determine the amount of mixing of thermal and non-thermal waters. RTEst can use data with basis species below detection limit, missing, or unreliable either by assuming equilibrium with a controlling mineral (fixed-analyte method) or by treating the analyte concentration as an optimization parameter. The inverse of variance weighting method included in RTEst provides more representative results than either the normalization or unit weighting methods. Finally, the ability of RTEst to calculate reservoir temperatures, gas fugacity, and mixing fractions demonstrates its usefulness as a tool for evaluating geothermal systems.

15 GEOTHERMAL ENERGY↗

SU-F-BRB-07: A Plan Comparison Tool to Ensure Robustness and Deliverability in Online-Adaptive Radiotherapy

Purpose: To develop a plan comparison tool that will ensure robustness and deliverability through analysis of baseline and online-adaptive radiotherapy plans using similarity metrics. Methods: The ViewRay MRIdian treatment planning system allows export of a plan file that contains plan and delivery information. A software tool was developed to read and compare two plans, providing information and metrics to assess their similarity. In addition to performing direct comparisons (e.g. demographics, ROI volumes, number of segments, total beam-on time), the tool computes and presents histograms of derived metrics (e.g. step-and-shoot segment field sizes, segment average leaf gaps). Such metrics were investigated for their ability to predict that an online-adapted plan reasonably similar to a baseline plan where deliverability has already been established. Results: In the realm of online-adaptive planning, comparing ROI volumes offers a sanity check to verify observations found during contouring. Beyond ROI analysis, it has been found that simply editing contours and re-optimizing to adapt treatment can produce a delivery that is substantially different than the baseline plan (e.g. number of segments increased by 31%), with no changes in optimization parameters and only minor changes in anatomy. Currently the tool can quickly identify large omissions or deviations from baseline expectations. As our online-adaptive patient population increases, we will continue to develop and refine quantitative acceptance criteria for adapted plans and relate them historical delivery QA measurements. Conclusion: The plan comparison tool is in clinical use and reports a wide range of comparison metrics, illustrating key differences between two plans. This independent check is accomplished in seconds and can be performed in parallel to other tasks in the online-adaptive workflow. Current use prevents large planning or delivery errors from occurring, and ongoing refinements will lead to increased assurance of plan quality.

60 APPLIED LIFE SCIENCES↗

An analytical coarse-graining method which preserves the free energy, structural correlations, and thermodynamic state of polymer melts from the atomistic to the mesoscale

Structural and thermodynamic consistency of coarse-graining models across multiple length scales is essential for the predictive role of multi-scale modeling and molecular dynamic simulations that use mesoscale descriptions. Our approach is a coarse-grained model based on integral equation theory, which can represent polymer chains at variable levels of chemical details. The model is analytical and depends on molecular and thermodynamic parameters of the system under study, as well as on the direct correlation function in the k → 0 limit, c{sub 0}. A numerical solution to the PRISM integral equations is used to determine c{sub 0}, by adjusting the value of the effective hard sphere diameter, d{sub HS}, to agree with the predicted equation of state. This single quantity parameterizes the coarse-grained potential, which is used to perform mesoscale simulations that are directly compared with atomistic-level simulations of the same system. We test our coarse-graining formalism by comparing structural correlations, isothermal compressibility, equation of state, Helmholtz and Gibbs free energies, and potential energy and entropy using both united atom and coarse-grained descriptions. We find quantitative agreement between the analytical formalism for the thermodynamic properties, and the results of Molecular Dynamics simulations, independent of the chosen level of representation. In the mesoscale description, the potential energy of the soft-particle interaction becomes a free energy in the coarse-grained coordinates which preserves the excess free energy from an ideal gas across all levels of description. The structural consistency between the united-atom and mesoscale descriptions means the relative entropy between descriptions has been minimized without any variational optimization parameters. The approach is general and applicable to any polymeric system in different thermodynamic conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Start of Combustion Sensor Phases I and II-A: Feasibility Demonstration, Design and Optimization

Homogeneous Compressed Charge Ignition (HCCI) has elevated the need for Start of Combustion (SOC) sensors. HCCI engines have been the exciting focus of engine research recently, primarily because HCCI offers higher thermal efficiency than the conventional Spark Ignition (SI) engines and significantly lower NOx and soot emissions than conventional Compression Ignition (CI) engines, and could be fuel neutral. HCCI has the potential to unify all the internal combustion engine technology to achieve the high-efficiency, low-emission goal. However, these advantages do not come easy. It is well known that the problems encountered with HCCI combustion center on the difficulty of controlling the Start of Combustion. TIAX has an SOC sensor under development which has shown promise. In previous work, including a DOE-sponsored SBIR project, TIAX has developed an accelerometer-based method which was able to determine SOC within a few degrees crank angle for a range of operating conditions. A signal processing protocol allows reconstruction of the combustion pressure event signal imbedded in the background engine vibration recorded by the accelerometer. From this reconstructed pressure trace, an algorithm locates the SOC. This SOC sensor approach is nonintrusive, rugged, and is particularly robust when the pressure event is strong relative to background engine vibration (at medium to high engine load). Phase I of this project refined the previously developed technology with an engine-generic and robust algorithm. The objective of the Phase I research was to answer two fundamental questions: Can the accelerometer-based SOC sensor provide adequate SOC event capture to control an HCCI engine in a feedback loop? And, will the sensor system meet cost, durability, and software efficiency (speed) targets? Based upon the results, the answer to both questions was 'YES'. The objective of Phase II-A was to complete the parameter optimization of the SOC sensor prototype in order to reach a juncture where plans can be and are discussed with an industry partner for how best to perform a more detailed implementation of the TIAX SOC technology on an HCCI engine system. This occurred, as evidenced the number of potential commercialization partners shown in Table 4. Potential Commercialization Partners Contacted (up to date as of January 31, 2010). During the two phases, a robust, engine-generic algorithm was developed that met the desired targets and was shown to work extremely well for HCCI engine operation.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing direct intense-field laser acceleration of ions

The dynamics of ion acceleration in tightly focused laser beams is investigated in relativistic simulations. Studies are performed to find the optimal parameters which maximize the energy gain, beam quality, and flux. The exit ionic kinetic energy and its uncertainty are improved and the number of accelerated particles is increased by orders of magnitude over our earlier results, especially when working with a longer laser wavelength. Laser beams of powers of 0.1-10 petawatts and focused to subwavelength spot radii are shown to directly accelerate protons and bare nuclei of helium, carbon, and oxygen from a few to several hundred MeV/nucleon. Variation of the volume of the initial ionic ensemble, as well as the introduction of a pulse shape on the laser fields, have been investigated and are shown to influence the exit particle kinetic energies only slightly.

43 PARTICLE ACCELERATORS↗

CEBAF Injector for K Long Beam Conditions

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab concurrently operates four experimental Halls with distinct bunch charge specifications and repetition rates. Numerous critical beam parameters within CEBAF are configured in the injector, some remaining unchanged throughout the accelerator. Consequently, the injector plays a crucial role in determining final beam characteristics, including bunch structure, beam sizes, bunch lengths, energy spread, and beam transmission. The Jefferson Lab KL experiment is scheduled to take place at CEBAF in Hall D, featuring a much lower bunch repetition rate of 7.80 MHz or 15.59 MHz, below the nominal values of 249.5 MHz or 499 MHz. Although the proposed average current of 5 ?A or 10 ?A is low compared to the maximum CEBAF cur- rent of approximately 180 ?A, the corresponding bunch charge is unusually high for CEBAF injector operation. This study focuses on the behavior of low-repetition-rate, high-bunch- charge (0.32 to 0.64 pC) beams in the CEBAF injector. We investigated the evolution and transmission of low-charge beams to space-charge dominated high-charge beams in the front end of the CEBAF injector for two configurations: the pre-existing CEBAF Phase 1 injector upgrade, operated at 130 kV, and the existing CEBAF Phase 2 injector upgrade, operated at 140 kV, 180 kV, and to be operated at 200 kV. The electron beam through the CEBAF injector is characterized using beam dynamics simulations and comparisons with the available measurements performed at 130 kV. Multi-objective genetic optimizations of the CEBAF injector were performed to determine the operating magnetic elements and RF settings for the evolution and transmission of low, moderate, and high charge beams in the CEBAF injector at 180 kV and 200 kV DC gun voltages. Subsequently, simulations at the same voltages were conducted to obtain the beam characteristics at the front end of the CEBAF injector. The laser spot size and laser pulse length at the cathode were varied to observe their effects on beam transmission in the injector at different voltages (130 kV, 180 kV, and 200 kV). Experimental studies at 130 kV, 140 kV, and 180 kV validate the simulations. Beam study measurements are carried out using EPICS tools, while optimizations and simulations are facilitated by General Particle Tracer. Based on the findings, optimal parameters for the upcoming Jefferson Lab KL experiment are proposed, utilizing a lower repetition rate and higher bunch charge

Pokharel, Sunil↗

SU-E-J-42: Customized Deformable Image Registration Using Open-Source Software SlicerRT

Purpose: SlicerRT is a flexible platform that allows the user to incorporate the necessary images registration and processing tools to improve clinical workflow. This work validates the accuracy and the versatility of the deformable image registration algorithm of the free open-source software SlicerRT using a deformable physical pelvic phantom versus available commercial image fusion algorithms. Methods: Optical camera images of nonradiopaque markers implanted in an anatomical pelvic phantom were used to measure the ground-truth deformation and evaluate the theoretical deformations for several DIR algorithms. To perform the registration, full and empty bladder computed tomography (CT) images of the phantom were obtained and used as fixed and moving images, respectively. The DIR module, found in SlicerRT, used a B-spline deformable image registration with multiple optimization parameters that allowed customization of the registration including a regularization term that controlled the amount of local voxel displacement. The virtual deformation field at the center of the phantom was obtained and compared to the experimental ground-truth values. The parameters of SlicerRT were then varied to improve spatial accuracy. To quantify image similarity, the mean absolute difference (MAD) parameter using Hounsfield units was calculated. In addition, the Dice coefficient of the contoured rectum was evaluated to validate the strength of the algorithm to transfer anatomical contours. Results: Overall, SlicerRT achieved one of the lowest MAD values across the algorithm spectrum, but slightly smaller mean spatial errors in comparison to MIM software (MIM). On the other hand, SlicerRT created higher mean spatial errors than Velocity Medical Solutions (VEL), although obtaining an improvement on the DICE to 0.91. The large spatial errors were attributed to the poor contrast in the prostate bladder interface of the phantom. Conclusion: Based phantom validation, SlicerRT is capable of achieving comparable DIR accuracy to commercial programs such as MIM and VEL.

60 APPLIED LIFE SCIENCES↗

Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system

The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. We selected for this study a total of 17 previously treated patients with a range of pelvic disease sites including prostate (9), bladder (1), uterus (3), rectum (3), and cervix (1). For each patient, 2 plans were generated, one using an arc-per-beam setting of “1” and another with an arc-per-beam setting of “2” using the volumes and constraints established from the initial clinical treatments. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the planning target volume (PTV) received 95% of the prescription dose. Plans were evaluated for PTV conformity, homogeneity, number of monitor units, number of control points, and overall plan acceptability. Treatment delivery time, patient-specific quality assurance procedures, and the impact on clinical workflow were also assessed. We found that for complex-shaped target volumes (small central volumes with extending arms to cover nodal regions), the use of 2 arc-per-beam (2APB) parameter setting achieved significantly lower average dose-volume histogram values for the rectum V{sub 20} (p = 0.0012) and bladder V{sub 30} (p = 0.0036) while meeting the high dose target constraints. For simple PTV shapes, we found reduced monitor units (13.47%, p = 0.0009) and control points (8.77%, p = 0.0004) using 2APB planning. In addition, we found a beam delivery time reduction of approximately 25%. In summary, the dosimetric benefit, although moderate, was improved over a 1APB setting for complex PTV, and equivalent in other cases. The overall reduced delivery time suggests that the use of mulitple arcs per beam could lead to reduced patient-on-table time, increased clinical throughput, and reduced medical physics quality assurance effort.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Comparison Between 3DCRT and IMRT Using Different Multileaf Collimators in the Treatment of Brain Tumors

We investigated the differences between 3-dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT), and the impact of collimator leaf-width on IMRT plans for the treatment of nonspherical brain tumors. Eight patients treated by 3DCRT with Novalis were selected. We developed 3 IMRT plans with different multileaf collimators (Novalis m3, Varian MLC-120, and Varian MLC-80) with the same treatment margins, number of beams, and gantry positions as in the 3DCRT treatment plans. Treatment planning utilized the BrainLAB treatment planning system. For each patient, the dose constraints and optimization parameters remained identical for all plans. The heterogeneity index, the percentage target coverage, critical structures, and normal tissue volumes receiving 50% of the prescription dose were calculated to compare the dosimetric difference. Equivalent uniform dose (EUD) and tumor control probability (TCP) were also introduced to evaluate the radiobiological effect for different plans. We found that IMRT significantly improved the target dose homogeneity compared to the 3DCRT. However, IMRT showed the same radiobiological effect as 3DCRT. For the brain tumors adjacent to (or partially overlapping with) critical structures, IMRT dramatically spared the volume of the critical structures to be irradiated. In IMRT plans, the smaller collimator leaf width could reduce the volume of critical structures irradiated to the 50% level for those partially overlapping with the brain tumors. For relatively large and spherical brain tumors, the smaller collimator leaf widths give no significant benefit.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-814: Whole Breast Irradiation with Two Different Intensity Modulation Radiotherapy Techniques

Purpose: Breast cancer now mainly received forward intensity modulation radiotherapy (f-IMRT) and inverse IMRT (i-IMRT). The purpose of this study was to observe the differences of two treatment methods. Methods: 10 patients after left breast-conserving surgery were selected to receive radiotherapy. For each patient, two treatment plans (f-IMRT and i-IMRT) were designed. For f-IMRT plans, two tangent beams were designed to the target, and in each tangent orientation two or three segment beams were designed to reduced high dose region in the target and the dose of lung received. For i-IMRT plans, two tangent beams were designed to the target and the treatment planning system optimize the dose according to the optimization parameters. For each plan 50Gy was prescribed. Results: In f-IMRT and i-IMRT plans, the average target conformal index (CI) were (0.67±0.06) and (0.66±0.06), (P>0.05); average homogeneity index (HI) were (28.2±6.0)% and (26.1±6.8)%, (P>0.05); volume of left lung received 20Gy (V20) were (18.7±3.3)% and (17.0±2.8)%, (P<0.05), V30 were (15.5±3.0)% and (14.0±2.6)%, (P<0.05); V30 of heart were (4.1±3.1)% and (3.5±2.5)%, (P>0.05); Monitor Unit (MU) were (262±5)MU and (308±14)MU. Conclusion: Compared with i-IMRT plan, for breast cancer, the differences of CI and HI were not significant. Because of fewer MU, f-IMRT plan could reduce the machine abrasion and treatment time, but dose of normal tissue received were higher significantly than i-IMRT plan.

60 APPLIED LIFE SCIENCES↗