Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

Three-Dimensional Super-Resolution: Theory, Modeling, and Field Tests Results

Many flash lidar applications continue to demand higher three-dimensional image resolution beyond the current state-of-the-art technology of the detector arrays and their associated readout circuits. Even with the available number of focal plane pixels, the required number of photons for illuminating all the pixels may impose impractical requirements on the laser pulse energy or the receiver aperture size. Therefore, image resolution enhancement by means of a super-resolution algorithm in near real time presents a very attractive solution for a wide range of flash lidar applications. This paper describes a superresolution technique and illustrates its performance and merits for generating three-dimensional image frames at a video rate.

Bulyshev, Alexander↗

Sharp Infrared Eyes The Journey of QWIPs from Concept to Large Inexpensive Sensitive Arrays in Hand-held Infrared Cameras

One of the simplest device realizations of the classic particle-in-a-box problem of basic quantum mechanics is the Quantum Well Infrared Photodetector (QWIP). Optimization of the detector design and material growth and processing has culminated in the realization of a camera with a large (256x256 pixel) focal plane array of QWIPs which can see at 8.5 mu m, holding forth great promise for a variety of applications in the 6-25 mu m wavelength range.

Quantum Well Infrared Photodetector QWIP quantum m↗

BIG MAC: A bolometer array for mid-infrared astronomy, Center Director's Discretionary Fund

The infrared array referred to as Big Mac (for Marshall Array Camera), was designed for ground based astronomical observations in the wavelength range 5 to 35 microns. It contains 20 discrete gallium-doped germanium bolometer detectors at a temperature of 1.4K. Each bolometer is irradiated by a square field mirror constituting a single pixel of the array. The mirrors are arranged contiguously in four columns and five rows, thus defining the array configuration. Big Mac utilized cold reimaging optics and an up looking dewar. The total Big Mac system also contains a telescope interface tube for mounting the dewar and a computer for data acquisition and processing. Initial astronomical observations at a major infrared observatory indicate that Big Mac performance is excellent, having achieved the design specifications and making this instrument an outstanding tool for astrophysics.

Telesco, C. M.↗

MagMicro with Ultra-High Energy Resolution (Progress Report Q4 FY18)

We are performing extensive simulations of the MMC detector response to optimize their energy resolution, detection efficiency and count rate based on the data we took in FY17/18. The optimized layout separates the MMC detector chip from the SQUID preamplifier chips coupled to the MMCs through Al wire bonds to avoid heating the MMC with the power dissipation of the SQUID. The goal is to design MMC gamma detectors with a limiting energy resolution below ~25 eV FWHM up to >100 keV and ~1 ms decay times for maximum count rates of several tens of counts/s per pixel. The simulations, which were done at the Supercomputing Center of the University of New Mexico, are taking significantly longer than expected. The difficulty is that the device performance depends intricately on the design parameters, and each simulation is quite involved because it needs to cover the frequency range well into the GHz range to account for the ac Josephson effect. This is delaying the start of the detector array fabrication, and we have not been able to complete the fabrication and the testing of the 32-pixel MMC arrays by September 30. We have therefore requested a no-cost extension of the project to March 31, 2019.

42 ENGINEERING↗

Decoding techniques for fine-fine geometry multi-anode microchannel arrays

The Multi-Anode Microchannel Array (MAMA) is a photon-counting detector which decodes the position of an event through coincidence discrimination. The decoding algorithm which associates a given event with the appropriate pixel is determined by the geometry of the array. The decoding process can be divided into two tasks: anode encoding and pixel decoding. Techniques for performing both tasks are described and contrasted in light of application requirements. Decode times of 75 nanoseconds have been achieved, and considerably faster decoders are possible given new architectures and technologies.

Kasle, David B.↗

Ultra Low Power Imaging Systems Using CMOS Image Sensor Technology

The need for miniaturization in advanced science sensor systems has led to the development of a new image sensor technology, the active pixel image sensor (APS). The development of CMOS APS technology allows the integration of timing and control electronics, imaging detector arrays, signal chains and analog-to-digital conversion on a single integrated circuit. The impact on the imaging system is to reduce power by approximately 1000x over existing systems - from tens of watts to tens of milliwatts.

imaging↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for x-ray astrophysics

Future x-ray astrophysics experiments require multiplexed readout of high-fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo pixel array of Mo/Au TESs read out with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will used to laboratory astrophysics experiments. Our array and TDM readout has demonstrated a combined energy resolution, including > 200 pixels, of: 1.95 eV for Ti-K (4.5 keV), 1.97 eV for Mn-K (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma error is  0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU.

Stephen J. Smith↗

Measurements of D–D fusion neutrons generated in nanowire array laser plasma using Timepix3 detector

Here, we present results of the neutron detection in laser plasma experiment with CD2 nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was using for the detection neutrons. D-D fusion neutrons were detected in a plastic converter through recoiled protons. Both the energy of recoiled protons and time-of-flight of neutrons (and thus their energy) were determined. We report (2.4±1.8) × 10 7 neutrons generated for 1 J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph

A 512-channel Faraday-strip array detector has been developed and fitted to a Mattauch-Herzog geometry mass spectrograph for the simultaneous acquisition of multiple mass-to-charge values. Several advantages are realized by using simultaneous detection methods, including higher duty cycles, removal of correlated noise, and multianalyte transient analyses independent of spectral skew. The new 512-channel version offers narrower, more closely spaced pixels, providing improved spectral peak sampling and resolution. In addition, the electronics in the amplification stage of the new detector array incorporate a sample-and-hold feature that enables truly simultaneous interrogation of all 512 channels. While sensitivity and linear dynamic range remain impressive for this Faraday-based detector system, limits of detection and isotope ratio data have suffered slightly from leaky p-n junctions produced during the manufacture of the semiconductor-based amplification and readout stages. This paper describes the new 512-channel detector array, the current dominant noise sources, and the figures of merit for the device as pertaining to inductively coupled plasma ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Precision Scanning Optical Pulser for Low-Temperature Particle Detectors

Gamma-ray spectroscopy using low-temperature microcalorimeter arrays has demonstrated breakthrough energy resolution, establishing an important new technique for the precise characterization of radioactive samples. However, the extraordinary dynamic range of these pixels, spanning tens of electronvolts to hundreds of kiloelectronvolts, places stringent requirements on the calibration accuracy of each pixel. In this paper, we describe the design, development, and initial reflectivity-map testing of a new optical pulser intended for the precise determination of energy calibrations of microcalorimeter pixels and pixel arrays. A high-resolution XYZ scanner combined with 3 K optics achieving a 3-μm focused spot permit in situ imaging and precise placement of the energy deposition on the detector. Lastly, absolute absorbed power can be calibrated via a precision measurement of detector thermal stand-off.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focal Plane Arrays of Voltage-Biased Superconducting Bolometers

The 200-micrometer to 3-mm wavelength range has great astronomical and cosmological significance. Science goals include characterization of the cosmic microwave background, measurement of the Sunyaev-Zel'dovich effect in galaxy clusters, and observations of forming galaxies. Cryogenic bolometers are the most sensitive broadband detectors in this frequency range. Because single bolometer pixels are reaching the photon noise limit for many observations, the development of large arrays will be critical for future science progress. Voltage-biased superconducting bolometers (VSBs) have several advantages compared to other cryogenic bolometers. Their strong negative electrothermal feedback enhances their linearity, speed, and stability. The large noise margin of the SQUID readout enables multiplexed readout schemes, which are necessary for developing large arrays. In this paper, we discuss the development of a large absorber-coupled array, a frequency-domain SQUID readout multiplexer, and an antenna-coupled VSB design.

Myers, Michael J.↗

TES-Based X-Ray Microcalorimeter Performances Under AC Bias and FDM for Athena

Athena is a European X-ray observatory, scheduled for launch in 2028. Athena will employ a high-resolution imaging spectrometer called X-ray integral field unit (X-IFU), consisting of an array of 4000 transition edge sensor (TES) microcalorimeter pixels. For the readout of X-IFU, we are developing frequency domain multiplexing, which is the baseline readout system. In this paper, we report on the performance of a TES X-ray calorimeter array fabricated at Goddard Space Flight Center (GSFC) at MHz frequencies for the baseline of X-IFU detector. During single-pixel AC bias characterization, we measured X-ray energy resolutions (at 6 keV) of about 2.9 eV at both 2.3 and 3.7 MHz. Furthermore, in the multiplexing mode, we measured X-ray energy resolutions of about 2.9 eV at 1.3 and 1.7 MHz.

Transition edge sensors X-ray microcalorimeter Fre↗

Development of Tiled Imaging CZT Detectors for Sensitive Wide-Field Hard X-Ray Surveys to EXIST

Motivated by the proposed EXIST mission, a "medium-class" space observatory to survey black holes and the Early Universe proposed to the 2010 NAS/NRC Astronomy and Astrophysics Decadal Survey, we have developed the first "large" area 256 sq cm close-tiled (0.6 mm gaps) hard X-ray (20-600 keV) imaging detector employing pixelated (2.5 mm) CdZnTe (CZT) detectors, each 2 x 2 x 0.5 cubic cm. We summarize the design, development and operation of this detector array (8 x 8 CZTs) and its performance as the imager for a coded aperture telescope on a high altitude (40 km) balloon flight in October. 2009, as the ProtoEX1STl payload. We then outline our current development of a second-generation imager, ProtcEXIST2. with 0.6 mm pixels on a 32 x 32 array on each CZT, and how it will lead to the ultimate imaging system needed for EXIST. Other applications of this technology will also be mentioned.

Grindlay, J.↗

A constrained, total-variation minimization algorithm for low-intensity x-ray CT

Purpose: The authors developed an iterative image-reconstruction algorithm for application to low-intensity computed tomography projection data, which is based on constrained, total-variation (TV) minimization. The algorithm design focuses on recovering structure on length scales comparable to a detector bin width. Methods: Recovering the resolution on the scale of a detector bin requires that pixel size be much smaller than the bin width. The resulting image array contains many more pixels than data, and this undersampling is overcome with a combination of Fourier upsampling of each projection and the use of constrained, TV minimization, as suggested by compressive sensing. The presented pseudocode for solving constrained, TV minimization is designed to yield an accurate solution to this optimization problem within 100 iterations. Results: The proposed image-reconstruction algorithm is applied to a low-intensity scan of a rabbit with a thin wire to test the resolution. The proposed algorithm is compared to filtered backprojection (FBP). Conclusions: The algorithm may have some advantage over FBP in that the resulting noise level is lowered at equivalent contrast levels of the wire.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Predicted Diurnal Variability - 1

Laboratory calibration and observed background radiance data are used to determine the effective sensitivities of the Optical Transient Detector and Lightning Imaging Sensor, as functions of local hour and pixel location within the instrument arrays. The effective LIS thresholds, expressed as radiances emitted normal to cloud top, are 4.0 plus or minus 0.7 and 7.6 plus or minus 3.3 micro J/ster/m (sup 2) for night and local noon; the OTD thresholds am 11.7 plus or minus 2.2 and 16.8 plus or minus 4.6 microJ/ster/m (sup 2). LIS and OTD minimum signal to noise ratios occur from 0800 to 1600 local time, and attain values of 10 plus or minus 2 and 20 plus or minus 3, respectively. False alarm rate due to instrument noise yields approximately 5 false triggers per month for LIS, and is negligible for OTD. Flash detection efficiency, based on prior optical pulse sensor measurements, is predicted to be 93 plus or minus 4% and 73 plus or minus 11% for LIS night and noon; 56 plus or minus 7% and 44 plus or minus 9% for OTD night and noon, corresponding to a 12 - 20% diurnal variability and LIS:OTD ratio of 1.7. Use of the weighted daily mean detection efficiency (i.e., not controlling for local hour) corresponds to a sigma = 8 - 9% uncertainty. These are likely overestimates of actual flash detection efficiency due to differences in pixel ground field-of-view across the instrument arrays, which are not accounted for in the validation optical pulse sensor data.

Boccippio, Dennis J.↗

Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

Smith, S. J.↗

Efficient Mirrorlet Array Based Integral Field Spectrometer (IFS) for HWO

Habitable World Observatory (HWO) is a NASA strategic mission recommended by 2020 astronomical decadal survey. Integral field spectrometers play an important role to verify if the observed exoplanet is habitable. The traditional lenslet array based IFS has the advantage of simplicity and compactness. However, it does not use detector pixels efficiently in order to prevent wavelength crosstalk among adjacent spectra. The efficient lenslet/mirrorlet IFS combines the advantages from both lenslet based and imager slicer based IFSes—keeping lenslet IFS’s simplicity and compactness, and adding slicer IFS’s detector efficiency. This paper discusses the principle of efficient lenslet/mirrorlet IFS, design philosophy, and efficient spectral trace layout ideals. It uses HWO NIR IFS requirement as an example to provide an efficiency mirrorlet IFS optical design. The high detector efficiency not only reduces needed detector pixel numbers, but also reduces the high communication rate demanding for such a large multiple instrument mission.

Qian Gong↗