Search NASA⌕ Search

SEARCH · Search NASA

Results for “power load profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Multiscale Electrothermal Design of a Modular Multilevel Converter for Medium-Voltage Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

computational fluid dynamics↗

Aerodynamic characterization of two tandem wind turbines under yaw misalignment control using actuator line model

Yaw control has proven to be promising in alleviating the wake effects that plague the efficiency of wind farms. In this work, the actuator line modeling (ALM) method is adopted to simulate the flows over two tandem turbines distanced by 3–7 rotor diameters, with the yaw angle of the upstream rotor varying from γ 1 = 0° to 50°. The aim is to provide a comprehensive aerodynamic characterization of this simple wind farm under yaw misalignment control. With increasing yaw angle, the power generated by the downstream rotor increases, compensating the power loss in the upstream rotor, and resulting in significantly higher total power of the two turbines than that without yaw control. The maximum power output is achieved as the upstream wake of the yawed rotor is redirected away from the downstream rotor plane. Behind the downstream rotor, the secondary steering phenomenon is observed, where the wake is also redirected from the centerline. The use of the actuator line model also reveal unsteady aerodynamic characteristics that cannot be captured by lower-fidelity models. For the upstream rotor, the yaw misalignment results in time-varying change in the local angle of attack on the blade, giving rise to unsteady loading. The downstream rotor is partially submerged in the deflected wake incurred by the yawed upstream rotor. As the blade revolves into and out of the wake deficit, the blade experiences cyclic loading, leading to even stronger fluctuations in the aerodynamic loads than the upstream rotor. These analysis provides a comprehensive understanding of the yaw control effects on the two tandem rotors from the perspectives of aerodynamic performance, wake profiles, and unsteady characteristics. In conclusion, the insights gained from the present study can aid the design of collective yaw control strategies of wind farms, and lay the foundation for assessing the fatigue damage associated with yaw misalignment.

17 WIND ENERGY↗

Power and Wind Shear Implications of Large Wind Turbine Scenarios in the US Central Plains

Continued growth of wind turbine physical dimensions is examined in terms of the implications for wind speed, power and shear across the rotor plane. High-resolution simulations with the Weather Research and Forecasting model are used to generate statistics of wind speed profiles for scenarios of current and future wind turbines. The nine-month simulations, focused on the eastern Central Plains, show that the power scales broadly as expected with the increase in rotor diameter (D) and wind speeds at hub-height (H). Increasing wind turbine dimensions from current values (approximately H = 100 m, D = 100 m) to those of the new International Energy Agency reference wind turbine (H = 150 m, D = 240 m), the power across the rotor plane increases 7.1 times. The mean domain-wide wind shear exponent (α) decreases from 0.21 (H = 100 m, D = 100 m) to 0.19 for the largest wind turbine scenario considered (H = 168 m, D = 248 m) and the frequency of extreme positive shear (α > 0.2) declines from 48% to 38% of 10-min periods. Thus, deployment of larger wind turbines potentially yields considerable net benefits for both the wind resource and reductions in fatigue loading related to vertical shear.

17 WIND ENERGY↗

Stratospheric Benzene and Hydrocarbon Aerosols Detected in Saturn's Auroral Regions

Context. Saturn's polar upper atmosphere exhibits significant auroral activity; however, its impact on stratospheric chemistry (i.e. the production of benzene and heavier hydrocarbons) and thermal structure remains poorly documented. Aims. We aim to bring new constraints on the benzene distribution in Saturn's stratosphere, to characterize polar aerosols (their vertical distribution, composition, thermal infrared optical properties), and to quantify the aerosols' radiative impact on the thermal structure. Methods. Infrared spectra acquired by the Composite Infrared Spectrometer (CIRS) on board Cassini in limb viewing geometry are analysed to derive benzene column abundances and aerosol opacity profiles over the 3 to 0.1 mbar pressure range. The spectral dependency of the haze opacity is assessed in the ranges 680-900 and 1360-1440 cm(exp −1). Then, a radiative climate model is used to compute equilibrium temperature profiles, with and without haze, given the haze properties derived from CIRS measurements. Results. On Saturn's auroral region (80 deg S), benzene is found to be slightly enhanced compared to its equatorial and mid-latitude values. This contrasts with the Moses & Greathouse (2005, J. Geophys. Res., 110, 9007) photochemical model, which predicts a benzene abundance 50 times lower at 80◦S than at the equator. This advocates for the inclusion of ion-related reactions in Saturn's chemical models. The polar stratosphere is also enriched in aerosols, with spectral signatures consistent with vibration modes assigned to aromatic and aliphatic hydrocarbons, and presenting similarities with the signatures observed in Titan's stratosphere. The aerosol mass loading at 80 deg S is estimated to be 1−4 × 10(exp −5) g cm(exp −2), an order of magnitude less than on Jupiter, which is consistent with the order of magnitude weaker auroral power at Saturn.We estimate that this polar haze warms the middle stratosphere by 6 K in summer and cools the upper stratosphere by 5 K in winter. Hence, aerosols linked with auroral activity can partly account for the warm polar hood observed in Saturn's summer stratosphere.

satellites↗

Simulation of Shuttle launch G forces and acoustic loads using the NASA Ames Research Center 20G centrifuge

The high cost and long times required to develop research packages for space flight can often be offset by using ground test techniques. This paper describes a space shuttle launch and reentry simulating using the NASA Ames Research Center's 20G centrifuge facility. The combined G-forces and acoustic environment during shuttle launch and landing were simulated to evaluate the effect on a payload of laboratory rates. The launch G force and acoustic profiles are matched to actual shuttle launch data to produce the required G-forces and acoustic spectrum in the centrifuge test cab where the rats were caged on a free-swinging platform. For reentry, only G force is simulated as the aero-acoustic noise is insignificant compared to that during launch. The shuttle G-force profiles of launch and landing are achieved by programming the centrifuge drive computer to continuously adjust centrifuge rotational speed to obtain the correct launch and landing G forces. The shuttle launch acoustic environment is simulated using a high-power, low-frequency audio system. Accelerometer data from STS-56 and microphone data from STS-1 through STS-5 are used as baselines for the simulations. This paper provides a description of the test setup and the results of the simulation with recommendations for follow-on simulations.

Shaw, T. L.↗

Predicting Maximum Temperatures of a Li-ion Battery on a Simulated Flight Profile using a Model-based Prognostics

One of the challenges in using Li-ion packs in aeronautics is their safety, and thermal runaway (TR) is a major concern. The current engineering solutions to prevent a Li-ion pack from a catastrophic TR require additional mass and volume to isolate cells. The excess mass could be reduced by improving detection and, thus, preventing a TR event. One of the possible early warning indicators of a TR is crossing a threshold temperature. We have developed an approach, based on the Unscented Kalman Filter (UKF), to predict the likelihood of reaching the threshold temperature for simulated flight profiles. The current battery prognostics algorithms for aerospace predict state-of-charge (SOC) and end-of-life (EOL) [1]. We extended this two-level algorithm to predict the maximum temperature during discharge. The amount of heat generated in a cell depends on factors such as cell chemistry, cell packaging, total cycles, operating temperature, and abuse history [2]. Our semi-empirical thermal model depends on three phenomenological parameters which account for those factors. In addition, a two-parameter reduced-order model is developed to predict the temperature rise for short bursts of “random-walk” (RW) discharge current sequence, which simulates a flight's current-loading profile. The performance of these models on different datasets and types of current loading will be presented. To predict the maximal temperatures for future cycles we must estimate the evolution of thermal parameters as the batteries age. It is found that the parameters of the 3-parametric thermal model cannot be estimated only from the RW data. To address the issue, we will present two alternative approaches: i) expanding the datasets to include discharge profiles beyond RWs; ii) model reduction to a two-parametric model. The two approaches will be illustrated by an application to the cycling data from a commercial LG 18650 cell. References: 1. M. Daigle, C.S. Kulkarni, End-of-discharge and End-of-life Prediction in Lithium-ion Batteries with Electrochemistry-based Aging Models, in: AIAA Infotech @ Aerospace, American Institute of Aeronautics and Astronautics, San Diego, California, USA, 2016. 2. M. Börner, et. al, Correlation of aging and thermal stability of commercial 18650-type lithium ion batteries, Journal of Power Sources. 342 (2017) 382–392.

Thermal runaway↗

The physics basis to integrate an MHD stable, high-power hybrid scenario to a cool divertor for steady-state reactor operation

Abstract Coupling a high-performance core to a low heat flux divertor is a crucial step for ITER and a Fusion Pilot Plant or DEMO. Experiments in DIII-D recently expanded the steady-state hybrid scenario to high density and divertor impurity injection to study the feasibility of a radiating mantle solution. This work presents the physics basis for trade-offs between density, current drive and stability to tearing modes (TMs) at high β. EC power is crucial to tailor the plasma profiles into a passively stable state, and to eject impurities from the core. Off-axis EC depositions decrease the heating efficiency, but calculated electron heat transport coefficients show that this effect is partially mitigated by improved confinement inside the EC deposition. Additionally, the reduction in pressure is recovered by increasing the density. This favourable scaling of confinement with density was observed in high power plasmas for years, and this work provides a comprehensive explanation. ELITE predictions indicate that a path in peeling-ballooning stability opens up for certain conditions of density, power, q 95 and shaping, allowing the edge pressure to continue increasing without encountering a limit. In the core, calculated anomalous fast-ion diffusion coefficients are consistent with density fluctuation measurements in the toroidicity-induced Alfvén eigenmode range, showing that smaller fast-ion losses contribute to the enhanced confinement at high density. The edge integration study shows that divertor heat loads can be reduced with Ne and Ar injection, but this eventually triggers a cascade of n = 1, 2, 3 core TMs. We can now show that impurity radiation in the core is small and it is not the cause for the drop in confinement at high Ar and Ne injection rates. The overlap between the core TMs is consistent with the loss of pressure as estimated by the Belt model for the coupled rational surfaces. Optimization of these trade-offs has achieved plasmas with sustained H 98y2 = 1.7, f GW = 0.7 and ∼85% mantle radiation. The scenario and its variations at higher density and on- vs off-axis EC heating has been studied as a candidate for an integrated solution for several reactor designs, such as ITER, ARC, and the ARIES-ACT1 case, showing promising results in terms of fusion power and gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A hybrid surrogate modeling framework for the Digital Twin of a Fluoride-salt-cooled High-temperature Reactor (FHR)

While nuclear energy is a non-greenhouse-gas emitting energy source, expensive operational costs due to the high-level of safety requirements decreases their competitiveness in the sustainable energy market. Advanced reactor concepts paired with Digital Twins aim to increase the commercialization gains of nuclear energy by reducing operational costs, increasing reactor reliability and enhancing power generation. To support Digital Twin tasks such as real-time autonomous control, proactive maintenance monitoring or optimizing power demand operations, a fast and accurate virtual representation of the Nuclear Power Plant (NPP) is required. The computational cost of high-fidelity, physics-based models are unsuitable for real-time analysis or scalability. Here, in this work, a hybrid surrogate modeling framework is developed fora Fluoride-salt-cooled High-temperature Reactor (FHR) that leverages physics-inspired models for key reactor components and uses data-driven methods for rapid system state space prediction. The Xenon reactivity feedback model is integrated to inform the surrogate model about the reactor core and the homologous pump theory model is the basis for representing pump degradation. Using a detailed, two dimensional thermal hydraulics model to generate data on the FHR, we train a network of Vectorized Autoregressive Moving-Average with eXogenous input (VARMAX) models to predict the remaining state values. The result is a surrogate model that provides a detailed reactor state representation of 41 system states and a pump degradation analysis. The framework is applied to Load Follows profiles, yielding high accuracy and a speedup that is more than 4000x faster compared to the higher- fidelity thermal hydraulics model, enabling real-time operational intelligence and applications in long horizon predictions. While the surrogate model framework is demonstrated for the particular case of FHR, the hybrid physical/data-driven modeling approach including the network of surrogates and the underlying modularity has the potential to be applied to other physical asset systems.

Digital Twins↗

Charts for estimating performance of high-performance helicopters

Theoretically derived charts showing the profile-drag-thrust ratio are presented for helicopter rotors operating in forward flight and having hinged rectangular blades with a linear twist of 0 degree, 8 degrees, and 16 degrees. The charts, showing the profile-drag characteristics of the rotor for various combinations of pitch angle, ratio of thrust coefficient to solidity, and a parameter representing shaft power input, are presented for tip-speed ratios ranging from 0.05 to 0.50. Also presented in chart form are the ratio of thrust coefficient to solidity as a function of angles of attack, as a function of inflow ratio and collective pitch, and as a function of power and thrust coefficients. The charts in this report are considered more accurate than previous ones for flight conditions involving high inflow velocities and large regions of reversed velocity that may be encountered by high-performance helicopters. The charts may be used to study the effects of design changes on rotor performance and to indicate optimum performance conditions, as well as to estimate quickly rotor performance in forward flight. They are also useful in obtaining inflow-ratio and pitch-angle values for use in calculating flapping coefficients and spanwise loadings. The method of applying the charts to performance estimation is illustrated through sample calculation of a typical rotor-performance problem.

Gessow, Alfred↗

EV Hosting Capacity Analysis on Distribution Grids

The increasing trend in electric vehicle (EV) adoption can cause challenges to traditional electric grid operations if utilities are not equipped with tools and methods to effectively manage these fleets. Growing EV charging loads will alter the magnitude and duration of conventional peaks in demand profiles and even significantly shift them, potentially causing operational violations in the distribution grid. This paper presents the development and results of an EV hosting capacity tool to quantify the impacts of injecting large numbers of EV charging loads and to determine the available capacity of existing distribution feeders to continue providing reliable and affordable grid operations. Tools like the hosting capacity analysis would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies to manage these loads, such as peak pricing and smart charging. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging options.

distribution grid↗

Integration issues of a plasma contactor Power Electronics Unit

A hollow cathode-based plasma contactor is baselined on International Space Station Alpha (ISSA) for spacecraft charge control. The plasma contactor system consists of a hollow cathode assembly (HCA), a power electronics unit (PEU), and an expellant management unit (EMU). The plasma contactor has recently been required to operate in a cyclic mode to conserve xenon expellant and extend system life. Originally, a DC cathode heater converter was baselined for a continuous operation mode because only a few ignitions of the hollow cathode were expected. However, for cyclic operation, a DC heater supply can potentially result in hollow cathode heater component failure due to the DC electrostatic field. This can prevent the heater from attaining the proper cathode tip temperature for reliable ignition of the hollow cathode. To mitigate this problem, an AC cathode heater supply was therefore designed, fabricated, and installed into a modified PEU. The PEU was tested using resistive loads and then integrated with an engineering model hollow cathode to demonstrate stable steady-state operation. Integration issues such as the effect of line and load impedance on the output of the AC cathode heater supply and the characterization of the temperature profile of the heater under AC excitation were investigated.

Pinero, Luis R.↗

The advanced tokamak path to a compact net electric fusion pilot plant

Abstract Physics-based simulations project a compact net electric fusion pilot plant with a nuclear testing mission is possible at modest scale based on the advanced tokamak concept, and identify key parameters for its optimization. These utilize a new integrated 1.5D core-edge approach for whole device modeling to predict performance by self-consistently applying transport, pedestal and current drive models to converge fully non-inductive stationary solutions, predicting profiles and energy confinement for a given density. This physics-based approach leads to new insights and understanding of reactor optimization. In particular, the levering role of high plasma density is identified, which raises fusion performance and self-driven ‘bootstrap currents’, to reduce current drive demands and enable high pressure with net electricity at a compact scale. Solutions at 6–7 T, ∼4 m radius and 200 MW net electricity are identified with margins and trade-offs possible between parameters. Current drive comes from neutral beam and ultra-high harmonic (helicon) fast wave, though other advanced approaches are not ruled out. The resulting low recirculating power in a double null configuration leads to a divertor heat flux challenge that is comparable to ITER, though reactor solutions may require more dissipation. Strong H-mode access (x2 margin over L–H transition scalings) and ITER-like heat fluxes are maintained with ∼20%–60% core radiation, though effects on confinement need further analysis. Neutron wall loadings appear tolerable. The approach would benefit from high temperature superconductors, as higher fields would increase performance margins while potential for demountability may facilitate nuclear testing. However, solutions are possible with conventional superconductors. An advanced load sharing and reactive bucking approach in the device centerpost region provides improved mechanical stress handling. The prospect of an affordable test device which could close the loop on net-electric production and conduct essential nuclear materials and breeding research is compelling, motivating research to validate the techniques and models employed here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A vortex sheet based analytical model of the curled wake behind yawed wind turbines

Motivated by the need for compact descriptions of the evolution of non-classical wakes behind yawed wind turbines, we develop an analytical model to predict the shape of curled wakes. Interest in such modelling arises due to the potential of wake steering as a strategy for mitigating power reduction and unsteady loading of downstream turbines in wind farms. We first estimate the distribution of the shed vorticity at the wake edge due to both yaw offset and rotating blades. By considering the wake edge as an ideally thin vortex sheet, we describe its evolution in time moving with the flow. Vortex sheet equations are solved using a power series expansion method, and an approximate solution for the wake shape is obtained. The vortex sheet time evolution is then mapped into a spatial evolution by using a convection velocity. Apart from the wake shape, the lateral deflection of the wake including ground effects is modelled. Our results show that there exists a universal solution for the shape of curled wakes if suitable dimensionless variables are employed. For the case of turbulent boundary layer inflow, the decay of vortex sheet circulation due to turbulent diffusion is included. Finally, we modify the Gaussian wake model by incorporating the predicted shape and deflection of the curled wake, so that we can calculate the wake profiles behind yawed turbines. Model predictions are validated against large-eddy simulations and laboratory experiments for turbines with various operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Economic analysis of a nuclear hybrid energy system in a stochastic environment including wind turbines in an electricity grid

The electricity market in the U.S. is moving toward an energy mix including more variable renewable energy (VRE) sources like wind and solar. This increasing VRE penetration is altering the profile of the net electricity demand. Normally, flexible generators (e.g. gas turbines) are used to absorb fluctuations in the electricity demand. Therefore, an increase in VRE also leads to an increase in installed capacity for such flexible generators which, in turn, may increase the price of electricity. Nuclear-Renewable Hybrid Energy Systems (N-R HES) are seen as a solution to this problem. The N-R HES contains a nuclear power plant electrically and/or thermally linked to an industrial process (IP). This paper demonstrates a new methodology and presents the corresponding RAVEN/Modelica-based software framework to evaluate the financial performance of N-R HES. The novelty of the method is that it explicitly incorporates the stochastic nature of N-R HES inputs such as electricity demand and wind speeds. The method is applied to a generic (rather than region-specific) N-R HES. The analysis shows that under the right market conditions, economic benefits can be achieved by adding a suitable IP to the base-load generator. In particular, there exists an optimal relationship between the IP capacity and the demand. Furthermore, global trends indicate VRE penetration raises the cost of electricity due to the added volatility, an issue only mitigated when operating with high profit margins for the IP.

97 MATHEMATICS AND COMPUTING↗

From Cell to System: Accelerated hpc Simulations of BESS Aging under Frequency Regulation and Arbitrage use cases

Lithium-ion battery energy storage systems (BESS) packs have emerged as a leading solution for grid-scale energy storage, enhancing resiliency and balancing load fluctuations. Yet, experimental characterization of large-format LIB packs-particularly to assess performance and degradation over hundreds of cycles - demands substantial hardware investment and multi-year testing campaigns. In this work, we couple a hierarchical, physics-based modeling framework agnostic to electrode chemistries with high-performance computing to accelerate systems level evaluation by upto two orders of magnitude. Building on the open-source liionpack platform, we implement cell, module, and pack-scale electrochemical models enriched with mechanistic aging mechanisms and deploy them on an HPC cluster to simulate 150−200kWh systems over 500 - 1,000 cycles with in days. We subject these virtual B ESS to both constant-current cycling and realistic grid service profiles spanning frequency regulation, ramp-rate support, and energy arbitrage-and quantify the resulting degradation patterns. Our results reveal that localized cell aging can induce substantial nonuniformity at module and pack levels, with service-specific cycling protocols driving distinct aging modes. This rapid, multiscale modeling approach provides a powerful design-space exploration tool for optimizing electrical architecture, control strategies, and operational schedules to prolong pack lifetime and lower total cost of ownership.

Ayalasomayajula, Surya [ORNL] (ORCID:0009000860788↗

Real-World Distribution System Modeling Framework for Transmission-and-Distribution Cosimulation: Preprint

This paper presents a modeling methodology for realistic distribution system simulation and analysis. The methodology involves three major approaches: utility model conversion, feeder load modeling, and feeder model validation. The feeder models obtained from the utility are converted to the format that is more flexible for analysis and algorithm development. The load profiles down to each node are modeled in detail using advanced metering infrastructure data and supervisory control and data acquisition (SCADA) system measured load data. Then the distribution system models are validated by comparing the simulated feeder-head voltage results and SCADA measured voltage data. To better understand the bulk system operations and the interactions between transmission and distribution systems, the modeled realistic distribution systems are integrated into a transmission-and-distribution cosimulation framework to perform the system simulation from the bulk system down to each node in the distribution system.

load modeling↗

Residential Demand Side Aggregation of Privacy-Conscious Consumers

The increasing adoption of smart meters has led to growing concerns regarding privacy risks stemming from the high resolution measurements. This has given rise to privacy protection techniques that physically alter the consumer's energy load profile, masking private information by using localised devices, e.g. batteries or flexible loads. Meanwhile, there has also been increasing interest in aggregating the distributed energy resources (DERs) of residential consumers to provide services to the grid. In this paper, we propose an online distributed algorithm to aggregate the DERs of privacy-conscious consumers to provide services to the grid, whilst preserving their privacy. Results show that the optimisation solution from the distributed method converges to one close to the optimum computed using an ideal centralised solution method, balancing between grid service provision, consumer preferences and privacy protection. More importantly, the distributed method preserves consumer privacy, and does not require high-bandwidth two-way communications infrastructure.

ancillary services↗