Search NASA⌕ Search

SEARCH · Search NASA

Results for “power networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Resilient Node Cluster Analysis Tool (ReNCAT) v. 2.1

SAND2021-6533 O The Resilient Node Cluster Analysis Tool (ReNCAT) identifies portions of a power distribution network that can be isolated into microgrids in order to supply services to a community during disruptive events. Candidate microgrid configurations are evaluated using a burden metric, a measure of the relative effort community members must expend to acquire services required for their well-being. Results present multiple candidate configurations, each with a different balance of cost and burden. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Melander, Darryl↗

Power System Event Classification and Localization Using a Convolutional Neural Network

Detection and timely identification of power system disturbances are essential for situation awareness and reliable electricity grid operation. Because records of actual events in the system are limited, ensemble simulation-based events are needed to provide adequate data for building event-detection models through deep learning; e.g., a convolutional neural network (CNN). An ensemble numerical simulation-based training data set have been generated through dynamic simulations performed on the Polish system with various types of faults in different locations. Such data augmentation is proven to be able to provide adequate data for deep learning. The synchronous generators’ frequency signals are used and encoded into images for developing and evaluating CNN models for classification of fault types and locations. With a time-domain stacked image set as the benchmark, two different time-series encoding approaches, i.e., wavelet decomposition-based frequency-domain stacking and polar coordinate system-based Gramian Angular Field (GAF) stacking, are also adopted to evaluate and compare the CNN model performance and applicability. The various encoding approaches are suitable for different fault types and spatial zonation. With optimized settings of the developed CNN models, the classification and localization accuracies can go beyond 84 and 91%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power generation forecasting for solar plants based on Dynamic Bayesian networks by fusing multi-source information

A Dynamic Bayesian network (DBN) model for solar power generation forecasting in solar plants is proposed in this paper. The key idea is to fuse sensor data, operational indicators, meteorological data, lagged output power information, and model errors for more accurate short-term (e.g., hours) and mid-term (e.g., days to weeks) power generation forecasting. The proposed DBN augments automated data-driven structure learning with expert knowledge encoding using continuous and categorical data given constraints to represent causal relationships within a solar inverter system. Additionally, an error compensation mechanism is proposed to capture temporal fluctuation. The effectiveness of the DBN on solar power generation forecasting was evaluated by rolling window analysis with one-year testing data collected from a local solar plant. The proposed DBN is compared with four state-of-art methods including support-vector regression (SVR), k-nearest neighbors (kNN), artificial neural network (ANN), and long short-term memory (LSTM) models. The result show that the proposed DBN achieves better accuracy in general, and it is not as data-hungry as some neural network-based models. The proposed DBN is also shown to have robust and consistent forecasting power with different forecasting horizons. The accuracy is 92% - 95% from one hour to one week ahead forecasting.

14 SOLAR ENERGY↗

PV-Diesel Hybrid SCADA Experiment Network Design

The essential features of an experimental network for renewable power system satellite based supervisory, control and data acquisition (SCADA) are communication links, controllers, diagnostic equipment and a hybrid power system. Required components for implementing the network consist of two satellite ground stations, to satellite modems, two 486 PCs, two telephone receivers, two telephone modems, two analog telephone lines, one digital telephone line, a hybrid-power system equipped with controller and a satellite spacecraft. In the technology verification experiment (TVE) conducted by Savannah State University and Florida Solar Energy Center, the renewable energy hybrid system is the Apex-1000 Mini-Hybrid which is equipped with NGC3188 for user interface and remote control and the NGC2010 for monitoring and basic control tasks. This power system is connected to a satellite modem via a smart interface, RS232. Commands are sent to the power system control unit through a control PC designed as PC1. PC1 is thus connected to a satellite model through RS232. A second PC, designated PC2, the diagnostic PC is connected to both satellite modems via separate analog telephone lines for checking modems'health. PC2 is also connected to PC1 via a telephone line. Due to the unavailability of a second ground station for the ACTS, one ground station is used to serve both the sending and receiving functions in this experiment. Signal is sent from the control PC to the Hybrid system at a frequency f(sub 1), different from f(sub 2), the signal from the hybrid system to the control PC. f(sub l) and f(sub 2) are sufficiently separated to avoid interference.

Kalu, Alex↗

Assessing DER Network Cybersecurity Defences in a Power-Communication Co-Simulation Environment

Increasing penetrations of interoperable distributed energy resources (DER) in the electric power system are expanding the power system attack surface. Maloperation or malicious control of DER equipment can now cause substantial disturbances to grid operations. Fortunately, many options exist to defend and limit adversary impact on these newly-created DER communication networks, which typically traverse the public internet. However, implementing these security features will increase communication latency, thereby adversely impacting real-time DER grid support service effectiveness. In this work, a collection of software tools called SCEPTRE were used to create a co-simulation environment where SunSpec-compliant PV inverters were deployed as virtual machines and interconnected to simulated communication network equipment. Network segmentation, encryption, and moving target defence security features were deployed on the control network to evaluate their influence on cybersecurity metrics and power system performance. The results indicated that adding these security features did not impact DER-based grid control systems but improved the cybersecurity posture of the network when implemented appropriately.

97 MATHEMATICS AND COMPUTING↗

Power quality disturbances diagnosis: A 2D densely connected convolutional network framework

The fast and accurate diagnosis of power quality disturbances (PQD) aids in avoiding shutdowns and unnecessary procedures, concerning electric energy distribution systems. As such, a number of techniques have been tested and applied in order to reach this objective. Majority of the techniques applied are two-step based. On the first step, power quality disturbances features are extracted. Second step, considering features extracted, disturbance classification is implemented. Recently, relevant literature has presented data-driven signal processing-based approaches, as deep convolutional neural networks (DCNN), which can implement both processing steps while providing automated recognition of patterns and outliers in data. However, not considered by state-of-art, power quality disturbances are evolving in nature, while all possible regularities might not be represented in the dataset. In this work a 2 Dimension Densely Connected Convolutional Network (2D-DenseNet) framework is presented. Further, a case study with synthetic disturbance events are analyzed. Easy-to-implement formulation, built on the 2D-DenseNet, without hard-to-design parameters, highlight potential aspects for real-life implementation.

42 ENGINEERING↗

Oscillatory Power Control and Consensus in Unbalanced Networks Using Grid Forming Inverters

In this paper, a state-space nonlinear control previously designed for balanced operation of grid-forming (GFM) inverters is extended to unbalanced operations. Unbalanced voltages and currents are analyzed, and their time-varying direct, quadrature, and zero components are parameterized in terms of six constant parameters. These parameters provide primary control design choices for not only an inverter’s terminal voltage but also its injections of both real and oscillatory power. It is shown that the proposed GFM control can precisely achieve a desired balanced terminal voltage under unbalanced loads. It is also shown that, by allowing the terminal voltage to be slightly unbalanced, oscillatory power can be adaptively minimized. Lastly, it is illustrated that oscillatory power can also be shared among multiple GFM inverters. Case studies and their simulations demonstrate that the proposed GFM control is effective in meeting the aforementioned objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Engineered Geothermal Systems Using Discrete Fracture Network Simulations

Electrical power production from geothermal energy has a solid record of success for permeable reservoirs such as The Geysers in northern California and geothermal systems in Iceland and New Zealand, among other places. Such permeable reservoirs, however, represent only a small fraction of the available heat energy in the earth’s shallow crust. Most of the available energy resides in rocks with insufficient permeability and storage to produce commercial volumes of heated fluids.

15 GEOTHERMAL ENERGY↗

Secure NTP Implementation for Power System Synchronization

Network Time Protocol (NTP), originally developed in the 1980s, remains one of the most widely adopted protocols for synchronizing clocks over Internet Protocol (IP)-based networks. It distributes time with millisecond-level accuracy across Ethernet-based systems and continues to be a standard in both enterprise and operational technology environments.

97 MATHEMATICS AND COMPUTING↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Smart-PGSim: Using Neural Network to Accelerate AC-OPF Power Grid Simulation

In this work we address the problem of accelerating complex power-grid simulation through machine learning ( ML). Specifically, we develop a framework, Smart-PGSim,which generates multitask-learning (MTL) neural network (NN)models to predict the initial values of variables critical to the problem convergence. MTL models allow information sharing when predicting multiple dependent variables while including customized layers to predict individual variables. We show that,to achieve the required accuracy, it is paramount to embed domain-specific constraints derived from the specific power-grid components in the MTL model. Smart-PGSim then employs the predicted initial values as a high-quality initial condition for the power-grid numerical solver (warm start), resulting in both higher performance compared to state-of-the-art solutions while maintaining the required accuracy. Smart-PGSim brings 2.60×speedup on average (up to 3.28×) computed over 10,000 problems, without losing solution optimality.

machine learning, neural networks↗

Communication enabled fast-acting imbalance reserve

A system and method for control of dispatchable resources on an electrical power distribution grid is disclosed. The disclosed method provides improved response to power imbalance based on a communications signal independent of system frequency. The communication signal provides a feed-forward control of dispatchable power resources. A communications network is employed to generate a signal to dispatchable resources that a power imbalance has occurred. Due to fast response power transmission network interfaces associated with the dispatchable resources, the respective resources respond in significantly less time than feedback controlled conventional generators which depend on line frequency sensing. The rapid response mitigates the impact of power imbalances and enables greater penetrations of converter-interfaced power generation units such as renewable energy sources to be connected to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Framework for Supporting Adaptive Droop Based Power Electronic Systems

The electric grid is evolving into an electrical network composed of power electronic converters interconnected with renewable and energy storage technologies. This requires the adoption of more advanced control such as volt/var regulation, fast frequency control, and active power frequency response. This work presents a communication and control framework to support dynamically changing droop control segments that can be used for different optimization schemes. Results are presented to work in a controller hardware in the loop testbed.

Starke, Michael↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Single Cobalt Sites Dispersed in Hierarchically Porous Nanofiber Networks for Durable and High-Power PGM-Free Cathodes in Fuel Cells

Increasing catalytic activity and durability of atomically dispersed metal–nitrogen–carbon (M–N–C) catalysts for the oxygen reduction reaction (ORR) cathode in proton-exchange-membrane fuel cells remains a grand challenge. In this study, a high-power and durable Co–N–C nanofiber catalyst synthesized through electrospinning cobalt-doped zeolitic imidazolate frameworks into selected polyacrylonitrile and poly(vinylpyrrolidone) polymers is reported. The distinct porous fibrous morphology and hierarchical structures play a vital role in boosting electrode performance by exposing more accessible active sites, providing facile electron conductivity, and facilitating the mass transport of reactant. The enhanced intrinsic activity is attributed to the extra graphitic N dopants surrounding the CoN 4 moieties. The highly graphitized carbon matrix in the catalyst is beneficial for enhancing the carbon corrosion resistance, thereby promoting catalyst stability. The unique nanoscale X-ray computed tomography verifies the well-distributed ionomer coverage throughout the fibrous carbon network in the catalyst. The membrane electrode assembly achieves a power density of 0.40 W cm –2 in a practical H 2 /air cell (1.0 bar) and demonstrates significantly enhanced durability under accelerated stability tests. The combination of the intrinsic activity and stability of single Co sites, along with unique catalyst architecture, provide new insight into designing efficient PGM-free electrodes with improved performance and durability.

25 ENERGY STORAGE↗