Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A high-precision radial-velocity survey for other planetary systems

The precise measurement of variations in stellar radial velocities provides one of several promising methods of surveying a large sample of nearby solar type stars to detect planetary systems in orbit around them. The McDonald Observatory Planetary Search (MOPS) was started in 1987 September with the goal of detecting other nearby planetary systems. A stabilized I2 gas absorption cell placed in front of the entrance slit to the McDonald Observatory 2.7 m telescope coude spectrograph serves as the velocity metric. With this I2 cell we can achieve radial velocity measurement precision better than 10 m/s in an individual measurement. At this level we can detect a Jupiter-like planet around a solar-type star, and have some hope of detecting Saturn-like planets in a long-term survey. The detectability of planets is ultimately limited by stellar pulsation modes and photospheric motions. Monthly MOPS observing runs allow us to obtain at least 5 independent observations per year of the 33 solar-type (F5-K7) stars on our observing list. We present representative results from the first five years of the survey.

Cochran, William D.↗

Development and flight test of a deployable precision landing system

A joint NASA Dryden Flight Research Facility and Johnson Space Center program was conducted to determine the feasibility of the autonomous recovery of a spacecraft using a ram-air parafoil system for the final stages of entry from space that included a precision landing. The feasibility of this system was studied using a flight model of a spacecraft in the generic shape of a flattened biconic that weighed approximately 150 lb and was flown under a commercially available, ram-air parachute. Key elements of the vehicle included the Global Positioning System guidance for navigation, flight control computer, ultrasonic sensing for terminal altitude, electronic compass, and onboard data recording. A flight test program was used to develop and refine the vehicle. This vehicle completed an autonomous flight from an altitude of 10,000 ft and a lateral offset of 1.7 miles that resulted in a precision flare and landing into the wind at a predetermined location. At times, the autonomous flight was conducted in the presence of winds approximately equal to vehicle airspeed. Several novel techniques for computing the winds postflight were evaluated. Future program objectives are also presented.

TRT-EXPERIMENTAL↗

Precision orbit determination for TOPEX/POSEIDON

The TOPEX/POSEIDON mission objective requires that the radial position of the spacecraft be determined with an accuracy better than 13 cm RMS (root mean square). This stringent requirement is an order of magnitude below the accuracy achieved for any altimeter mission prior to the definition of the TOPEX/POSEIDON mission. To satislfy this objective, the TOPEX Precision Orbit determination (POD) Team was established as a joint effort between the NASA Goddard Space Flight Center and the University of Texas at Austin, with collaboration from the University of Colorado and the Jet Propulsion Laboratory. During the prelaunch development and the post launch verification phases, the POD team improved, calibrated, and validated the precision orbit determination computer software systems. The accomplishments include (1) increased accuracy of the gravity and surface force models and (2) improved peformance of both laser ranging and Doppler tracking systems. The result of these efforts led to orbit accuracies for TOPEX/POSEIDON which are significantly better than the original mission requirement. Tests based on data fits, covariance analysis, and orbit comparisons indicate that the radial component of the TOPEX/POSEIDON spacecraft is determined, relative to the Earth's mass center, with an root mean square (RMS) error in the range of 3 to 4 cm RMS. This orbit accuracy, together with the near continuous dual-frequency altimetry from this mission, provides the means to determine the ocean's dynamic topography with an unprecedented accuracy.

Tapley, B. D.↗

Early results from the TOPEX/POSEIDON GPS precise orbit determination demonstration

TOPEX/POSEIDON, a US/French oceanographic mission launched in August 1992, is the first earth satellite to carry a multi-channel, dual frequency Global Positioning System (GPS) receiver capable of making high precision P-code pseudorange and carrier phase measurements. The receiver was placed on TOPEX/POSEIDON as an experiment to demonstrate the potential of differential GPS tracking for subdecimeter orbit determination. In addition to the receiver, TOPEX/POSEIDON carries two flight-proven tracking systems to provide the operational precise orbit determination needed to meet the mission scientific requirements. These include a French-built one-way Doppler system known as DORIS (Doppler Orbitography and Radiopositioning Integrated by Satellite) and a circular ring of laser retroreflectors. Here we evaluate the quality of the GPS-determined orbits by examining post-fit residuals, orbit comparisons with DORIS, and orbit repeatability on overlapping data arcs. Overlapping data arcs with 6 hrs of common data out of a 30-hr arc have an average root-mean-square (RMS) altitude difference of 3.0 cm for 9 arcs. The average RMS altitude difference about the mean with a DORIS orbit was 5.7 cm.

Bertiger, Willy↗

Antisymmetric Layup Of Precise Composite Laminates

Warping of precise composite-material (graphite-fiber/epoxy-matrix) laminated panels reduced, according to proposal, by improved combination of design and method of fabrication. Essence of proposal to stack plies during fabrication in such pattern that effects of unavoidable ply-orientation errors in individual layers cancel each other out, on whole, in final product. Emerged from study of warping of composite-material laminated face sheets undergoing development for use as lightweight substrates for precise, curved mirrors in submillimeter-wave astronomical telescopes and optical communication systems.

Rapp, Donald↗

CCD/CID Processors Would Offer Greater Precision

Charge-coupled-device/charge-injection-device (CCD/CID) data processors of proposed type offer advantages of massively parallel computational architecture and high computational speed typical of older CCD/CID data processors, but with increased precision. Useful in performing matrix vector multiplications in variety of applications, including solving partial differential equations, processing signal and image data, control computations, and neural-network simulations. Greater precision of proposed devices help to ensure accuracy in CCD/CID implementations of pseudospectral neural networks - particular class of artificial neural networks especially suited to solving nonlinear differential equations.

Barhen, Jacob↗

Assembling Precise Truss Structures With Minimal Stresses

Improved method of assembling precise truss structures involves use of simple devices. Tapered pins that fit in tapered holes indicate deviations from prescribed lengths. Method both helps to ensure precision of finished structures and minimizes residual stresses within structures.

Sword, Lee F.↗

Testing of an End-Point Control Unit Designed to Enable Precision Control of Manipulator-Coupled Spacecraft

This paper presents an end-point control concept designed to enable precision telerobotic control of manipulator-coupled spacecraft. The concept employs a hardware unit (end-point control unit EPCU) that is positioned between the end-effector of the Space Shuttle Remote Manipulator System and the payload. Features of the unit are active compliance (control of the displacement between the end-effector and the payload), to allow precision control of payload motions, and inertial load relief, to prevent the transmission of loads between the end-effector and the payload. This paper presents the concept and studies the active compliance feature using a simulation and hardware. Results of the simulation show the effectiveness of the EPCU in smoothing the motion of the payload. Results are presented from initial, limited tests of a laboratory hardware unit on a robotic arm testbed at the l Space Flight Center. Tracking performance of the arm in a constant speed automated retraction and extension maneuver of a heavy payload with and without the unit active is compared for the design speed and higher speeds. Simultaneous load reduction and tracking performance are demonstrated using the EPCU.

Montgomery, Raymond C.↗

27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, held November 29 - December 1, 1995 at San Diego, CA. Papers are in the following categories: Recent developments in rubidium, cesium, and hydrogen-based frequency standards; and in cryogenic and trapped-ion technology; International and transnational applications of PTTI technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; Applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; Applications of PTTI technology to evolving military communications and navigation systems; and Dissemination of precise time and frequency by means of Global Positioning System (GPS), Global Satellite Navigation System (GLONASS), MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗

Performance of a Smart Vibration Isolator for Precision Spacecraft Instruments

Under the ARPA SMS Partnership Program for Synthesis and Processing of Smart Materials, Lockheed Missiles and Space company, Inc. has developed a demonstration prototype vibration cancelling mount using electrostrictive ceramic and shape-memory alloy actuators. Shape-memory actuators provide an adaptive-passive, self-damping support for isolation, while the electrostrictive actuators are employed to provide force and position control. The demonstration device was designed to address generic requirements for vibration stabilization of precision spacecraft instruments. It is reconfigurable to operate in any of four modes; passive isolation, active-passive isolation using force cancellation, active precision positioning, and active disturbance rejection. The presentation summarizes design of the device design and results of experimental evaluations of the device in isolation (active and passive) and positioning modes. Rejection of payload-borne disturbances is also discussed with reference to predictions from experimentally calibrated simulations. Finally, avenues for further development and refinement of the device are discussed.

Regelbrugge, Marc E.↗

Test of CCD Precision Limits for Differential Photometry

Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 10(exp 5). Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.

Robinson, L. B.↗

Test of CCD Precision Limits for Differential Photometry

Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 105. Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.

Borucki, W. J.↗

Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

Yeh, Nai-Chang↗

Fabrication and Assembly of High-Precision Hinge and Latch Joints for Deployable Optical Instruments

Descriptions are presented of high-precision hinge and latch joints that have been co-developed, for application to deployable optical instruments, by NASA Langley Research Center and Nyma/ADF. Page-sized versions of engineering drawings are included in two appendices to describe all mechanical components of both joints. Procedures for assembling the mechanical components of both joints are also presented. The information herein is intended to facilitate the fabrication and assembly of the high-precision hinge and latch joints, and enable the incorporation of these joints into the design of deployable optical instrument systems.

Phelps, James E.↗

Precision Interval Estimation of the Response Surface by Means of an Integrated Algorithm of Neural Network and Linear Regression

The integration of Radial Basis Function Networks and Back Propagation Neural Networks with the Multiple Linear Regression has been accomplished to map nonlinear response surfaces over a wide range of independent variables in the process of the Modem Design of Experiments. The integrated method is capable to estimate the precision intervals including confidence and predicted intervals. The power of the innovative method has been demonstrated by applying to a set of wind tunnel test data in construction of response surface and estimation of precision interval.

Lo, Ching F.↗

Precise Image-Based Motion Estimation for Autonomous Small Body Exploration

Space science and solar system exploration are driving NASA to develop an array of small body missions ranging in scope from near body flybys to complete sample return. This paper presents an algorithm for onboard motion estimation that will enable the precision guidance necessary for autonomous small body landing. Our techniques are based on automatic feature tracking between a pair of descent camera images followed by two frame motion estimation and scale recovery using laser altimetry data. The output of our algorithm is an estimate of rigid motion (attitude and position) and motion covariance between frames. This motion estimate can be passed directly to the spacecraft guidance and control system to enable rapid execution of safe and precise trajectories.

Johnson, Andrew E.↗

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

Strayer, D. M.↗

Ultra-Light Precision Membrane Optics

SRS Technologies and NASA Marshall Space Flight Center have conducted a research effort to explore the possibility of developing ultra-lightweight membrane optics for future imaging applications. High precision optical flats and spherical mirrors were produced under this research effort. The thin film mirrors were manufactured using surface replication casting of CPI(Trademark), a polyimide material developed specifically for UV hardness and thermal stability. In the course of this program, numerous polyimide films were cast with surface finishes better than 1.5 nanometers rms and thickness variation of less than 63 nanometers. Precision membrane optical flats were manufactured demonstrating better than 1/13 wave figure error when measured at 633 nanometers. The aerial density of these films is 0.037 kilograms per square meter. Several 0.5-meter spherical mirrors were also manufactured. These mirrors had excellent surface finish (1.5 nanometers rms) and figure error on the order of tens of microns. This places their figure error within the demonstrated correctability of advanced wavefront correction technologies such as real time holography.

Moore, Jim↗