Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Performance Comparison at Mach Numbers 1.8 and 2.0 of Full Scale and Quarter Scale Translating-Spike Inlets

The performance of a full-scale translating-spike inlet was obtained at Mach numbers of 1.8 and 2.0 and at angles of attach from 0 deg to 6 deg. Comparisons were made between the full-scale production inlet configuration and a geometrically similar quarter-scale model. The inlet pressure-recovery, cowl pressure-distribution, and compressor-face distortion characteristics of the full-scale inlet agreed fairly well with the quarter-scale results. In addition, the results indicated that bleeding around the periphery ahead of the compressor-face station improved pressure recovery and compressor-face distortion, especially at angle of attack.

Anderson, B. H.↗

Evaluation of a low aspect ratio small axial compressor stage, volume 1

A program was conducted to evaluate the effects of scaling, tip clearance, and IGV reset on the performance of a low aspect ratio compressor stage. Stage design was obtained by scaling an existing single stage compressor by a linear factor of 0.304. The design objective was to maintain the meanline velocity field of the base machine in the smaller size. Adjustments were made to account for predicted blockage differences and to chord lengths and airfoil edge radii to obtain reasonable blade geometries. Meanline velocity diagrams of the base stage were not maintained at the scaled size. At design speed and flowrate the scaled stage achieved a pressure ratio of 1.423, adiabatic efficiency of 0.822, and surge margin of 18.5%. The corresponding performance parameters for the base stage were 1.480, 0.872, and 25.2%, respectively. The base stage demonstrated a peak efficiency at design speed of 0.872; the scaled stage achieved a level of 0.838. When the scaled stage rotor and stator tip clearances were doubled, the stage achieved a pressure ratio of 1.413, efficiency of 0.799, and surge margin of 16.0% at the design flowrate. The peak stage efficiency at design speed was 0.825 with the increased clearance. Increased prewhirl lowered the stage pressure ratio as expected. Stage efficiency was maintained with ten degrees of increased prewhirl and then decreased substantially with ten additional degrees of reset.

Sawyer, C. W., III↗

The 727 airplane side inlet low-speed performance confirmation model test for refanned JT8D engines

The results of a low-speed wind tunnel test of a 0.3 scale model 727 airplane side inlet for JT8D-100 engines are presented. The objectives of the test were to develop lines for a full-scale flightworthy inlet, to evaluate inlet total pressure recovery and steady-state total pressure distortion, and to obtain model-scale distortion data which can be used in the assessment of the compatibility of the inlet with the JT8D-100 series engines. A secondary objective was to obtain internal/external cowl static pressures for the determination of nacelle loads. Two basic inlet models were tested at static, forward speed, angle-of-attack (inflow angle), and cross-wind conditions. One model was with and one without an acoustic ring. Two modifications to the models were also tested, one with the ring closer to the inlet throat and one with a larger lip. Test measurements consisted of inlet surface static pressure, engine face total pressure, inlet airflow, tunnel total pressure, tunnel total temperature and tunnel velocity. Total pressure traverses were taken directly behind the ring and strut. No dynamic measurements were taken.

Schuehle, A. L.↗

Validation of Cryogenic Propellant Tank Self-Pressurization

NASA’s near-future long-term space missions necessitate advancements in cryogenic fluid management (CFM), which includes safe and reliable long-term propellant storage. Consequently, NASA STMD (Space Technology Mission Directorate) has established the CFM Portfolio Project to improve CFM technologies for upcoming missions. As a part of CFM Modeling Portfolio, NASA Marshall Space Flight Center’s (MSFC) Fluid Dynamics branch within the Propulsion Systems Department is tasked with assessing and improving computational tools used to support flight projects such as Human Lander System and Commercial Lunar Payload Services. One of the challenging modeling problems is that of self-pressurization of propellant tank due to heat leakage over long time periods. Reduced order and nodal tools find it extremely difficult to accurately predict self-pressurization under transient conditions or where complex flow patterns or thermal gradients exist, and application of 3-D CFD (computational fluid dynamics) simulations is necessary to characterize these problems. Until recently, CFD simulations for these long-term processes (order of hours or days) have been too impractical to conduct due to prohibitive wall time and computational resource requirements. The requisite CFD tool need to be efficient, computationally scalable, modular with ability to incorporate various physics models, and robust enough to not accumulate conservation errors over several hours of simulated time. NASA MSFC’s Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. In this paper, we validate Loci-Stream for predicting self-pressurization of a flight scale propellant tank so it can serve as a reliable design and analysis tool for NASA’s CFM application needs. Liquid hydrogen tank pressurization tests carried out at the K-site testing facility provide a reliable data set for this purpose. These tests were simulated using Loci-Stream solver with VOF module as well as a hybrid approach which uses a lumped model for the ullage gas domain and CFD simulation of the liquid propellant. Both are shown to have very good predictive capabilities over multiple K-site experiments.

Hong Q. Yang↗

Validation of Cryogenic Propellant Tank Self-Pressurization

NASA's near-future long-term space missions necessitate advancements in cryogenic fluid management (CFM), which includes safe and reliable long-term propellant storage. Consequently, NASA STMD (Space Technology Mission Directorate) has established the CFM Portfolio Project to improve CFM technologies for upcoming missions. As a part of CFM Modeling Portfolio, NASA Marshall Space Flight Center's (MSFC) Fluid Dynamics branch within the Propulsion Systems Department is tasked with assessing and improving computational tools used to support flight projects such as Human Lander System and Commercial Lunar Payload Services. One of the challenging modeling problems is that of self-pressurization of propellant tank due to heat leakage over long time periods. Reduced order and nodal tools find it extremely difficult to accurately predict self-pressurization under transient conditions or where complex flow patterns or thermal gradients exist, and application of 3-D CFD (computational fluid dynamics) simulations is necessary to characterize these problems. Until recently, CFD simulations for these long-term processes (order of hours or days) have been too impractical to conduct due to prohibitive wall time and computational resource requirements. The requisite CFD tool need to be efficient, computationally scalable, modular with ability to incorporate various physics models, and robust enough to not accumulate conservation errors over several hours of simulated time. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. In this paper, we validate Loci-Stream for predicting self-pressurization of a flight scale propellant tank so it can serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the K-site testing facility provide a reliable data set for this purpose. These tests were simulated using Loci-Stream solver with VOF module as well as a hybrid approach which uses a lumped model for the ullage gas domain and CFD simulation of the liquid propellant. Both are shown to have very good predictive capabilities over multiple K-site experiments.

cryogenic fluid management↗

Residual Strength Analysis Methodology: Laboratory Coupons to Structural Components

The NASA Aircraft Structural Integrity (NASIP) and Airframe Airworthiness Assurance/Aging Aircraft (AAA/AA) Programs have developed a residual strength prediction methodology for aircraft fuselage structures. This methodology has been experimentally verified for structures ranging from laboratory coupons up to full-scale structural components. The methodology uses the critical crack tip opening angle (CTOA) fracture criterion to characterize the fracture behavior and a material and a geometric nonlinear finite element shell analysis code to perform the structural analyses. The present paper presents the results of a study to evaluate the fracture behavior of 2024-T3 aluminum alloys with thickness of 0.04 inches to 0.09 inches. The critical CTOA and the corresponding plane strain core height necessary to simulate through-the-thickness effects at the crack tip in an otherwise plane stress analysis, were determined from small laboratory specimens. Using these parameters, the CTOA fracture criterion was used to predict the behavior of middle crack tension specimens that were up to 40 inches wide, flat panels with riveted stiffeners and multiple-site damage cracks, 18-inch diameter pressurized cylinders, and full scale curved stiffened panels subjected to internal pressure and mechanical loads.

Dawicke, D. S.↗

Acoustic testing of a 1.5 pressure ratio low tip speed fan with casing tip bleed (QEP Fan B scale model)

A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a rotor tip casing bleed slot to determine its effects on noise generation. The bleed slot was located 1/2 inch (1.3 cm) upstream of the rotor leading edge and was configured to be a continuous opening around the circumference. The bleed manifold system was operated over a range of bleed rates corresponding to as much as 6% of the fan flow at approach thrust and 4.25% of the fan flow at takeoff thrust. Acoustic results indicate that a bleed rate of 4% of the fan flow reduces the fan maximum approach 200 foot (61.0 m) sideline PNL 0.5 PNdB and the corresponding takeoff thrust noise 1.1 PNdB below the level with zero bleed. However, comparison of the standard casing (no bleed slot) and the slotted bleed casing with zero bleed shows that the bleed slot itself caused a noise increase.

Kazin, S. B.↗

Experimental investigation and analysis of two sources of nozzle-thrust misalignment

Asymmetry of nozzle's throat produces oscillatory type net side-force axial profile. Using mean values of localized static pressure and Mach number, scaling laws for flat-plate supersonic flow over protrusion are applied to nozzle expansion cone irregularities to give approximate indication of perturbed-pressure profiles and induced side forces.

Dowdy, M. W.↗

Simulation of the atmospheric boundary layer in the wind tunnel for modeling of wind loads on low-rise structures

The lower part of the atmospheric boundary layer (strong wind conditions) was simulated in low speed wind tunnel for the modeling of wind loads on low-rise structures. The turbulence characteristics of the turbulent boundary layer in the wind tunnel are compared with full scale measurements and with measurements made at NASA Wallops Flight Center. Wind pressures measured on roofs of a 1:70 scale model of a small single family dwelling were compared with results obtained from full scale measurements. The results indicate a favorable comparison between full scale and model pressure data as far as mean, r.m.s. and peak pressures are concerned. In addition, results also indicate that proper modeling of the turbulence is essential for proper simulation of the wind pressures.

Tieleman, H. W.↗

Isolator Shock Train Response to Dual-Mode Scramjet Throttling-Like Forcing

Typical dual-mode scramjet designs employ an isolator component situated between the inlet and combustor. The isolator fluidically buffers the inlet from the combustor via the formation of a shock train, an interconnected series of shock-boundary layer interactions. The isolator is required during ramjet-engine operation and at the lower edges of the scramjet operational envelope. In an operational engine, transient behavior imposes fluidic dynamics due to attitude adjustments, combustor throttling, aberrant resonances within the combustor, etc. To accommodate these transients, the shock train adjusts on both temporal and spatial scales. Sufficiently large downstream pressure increases in the combustor play a critical role during unstart, whereby strong compression waves propagate upstream in the isolator to ultimately force the shock train out the inlet, if it cannot stabilize to the pressure increase. This critically reduces the engine mass flow rate, potentially causing a catastrophic reduction in thrust and loss of the vehicle. A nearly instantaneous unstart can, in principle, be predicted by a ratio of the normal shock pressure jump in an inviscid isolator. However, lower-magnitude perturbations, below this bound, also induce unstarts. Understanding the transient behavior inherent in unsteady isolator operation is critical to reducing safety margin in isolator length and refining engine control algorithms to improve engine performance. The Isolator Dynamics Research Lab (IDRL) is a cold-flow, direct-connect isolator facility ideal for assessing the fundamental fluid dynamics of shock trains. The internal flow of a scramjet isolator is modeled using a 2D, symmetric Mach 2.5 nozzle followed by a 695 mm long, 25.4x50.8 mm rectangular isolator test section. A blockage cone on a high-speed ball screw actuator downstream of the isolator is pulsed to simulate the throttling behavior in an operational combustor. Wall flush high-speed static pressure transducers detect the streamwise shock train within the isolator. Time delays between the onset of the throttling and the response motion of the shock train are analyzed to assess the controlling scales and parameters. From this analysis, the response time of the isolator shock train system is found to depend primarily on the isolator back pressure time-rate-of-change but quickly saturates to a maximum propagation speed along the isolator. These results inform dual-mode scramjet engine designers of the critical parameters and limits of an unstart resistant engine.

scramjet↗

Post-operative cranial pressure monitoring system

System for monitoring of fluidic pressures in cranial cavity uses a miniaturized pressure sensing transducer, combined with suitable amplification means, a meter with scale calibrated in terms of pressures between minus 100 and plus 900 millimeters of water, and a miniaturized chart recorder covering similar range of pressures.

Fager, C. A., Jr.↗

High-capacity compact vortex valve for increasing stability of supersonic mixed-compression inlets

A special vortex valve was developed for increasing the stability margin of supersonic jet-engine inlets without the use of moving mechanical parts. A compact valve with high flow capacity and with high gain was obtained by using a unique outer wall in the vortex chamber instead of the usual cylindrical shape. The physical features of the valve are described, and the steady pressure-flow characteristics measured on scale models are given. Procedures are provided for adjusting the operating pressure, flow capacity, and gain through systematic changes in geometry.

Gebben, V. D.↗

Dependence of Venus ionopause altitude and ionospheric magnetic field on solar wind dynamic pressure

The shape of the dayside Venus ionopause, and its dependence on solar wind parameters, is examined using Pioneer Venus Orbiter field and particle data. The ionopause is defined here as the altitude of pressure equality between magnetosheath pressure and ionospheric thermal pressure; its typical altitudes range from about 300 km near the subsolar point to about 900 km near the terminator. A strong correlation between ionopause altitude and magnetosheath magnetic pressure is demonstrated; correlation between magnetic pressure and the normally incident component of solar wind dynamic pressure is also evident. The data support the hypothesis of control of the ionopause altitude by solar wind dynamic pressure, manifested in the sheath as magnetic pressure. The presence of large scale magnetic fields in the ionosphere is observed primarily when dynamic pressure is high and the ionopause is low.

Phillips, J. L.↗

Validation of Loci-Stream for Autogenous Pressurization of Cryogenic Propellant Tank

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

cryogenic fluid management↗

Validation of Loci-Stream for Autogenous Pressurization of Cryogenic Propellant Tank

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

CFM↗

Validation of Two Phase Flow Modeling Techniques in Loci-Stream using Axial Jet Pressure Control and Autogenous Pressurization Experiment

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

cryogenic fluid management↗

A three-parameter approximation for radiative transfer in nonhomogeneous atmospheres - Application to the O3 9.6-micron band

A three-parameter scaling approximation is developed in conjunction with random models for the computation of transmittance along nonhomogeneous atmospheres. In addition to the scaled path length and pressure, a third parameter is introduced to account for intermediate absorption. With reference to the results derived from line-by-line calculations, the accuracy of this scaling approximation is assessed in different atmospheric conditions. For the O3 9.6-micron band where the Curtis-Godson and other conventional scaling methods usually produce large errors, the present model can achieve relative accuracies within about 1 percent in transmittance and the downward surface flux. Accuracy of about 0.15 K/d can be obtained in cooling rate calculations. The present three-parameter approximation is well suited for radiative transfer parameterizations in which the demand for high accuracy is required in the transmittance and flux calculations.

Fu, Qiang↗

CFD Modeling of Phase Change and Pressure Drop during Violent Sloshing of Cryogenic Fluid in a Small-Scale Tank

This paper presents the development of a two-phase CFD model that is used to study sloshing of a cryogenic fluid (LN2) undergoing phase change generated by lateral acceleration and its effects on the ensuing heat and mass transfer and pressure drop in a small-scale tank. In this model the interface is captured using the volume-of-fluid (VOF) method [1]. Kinetic-theory based Schrage relation [2] is used for calculating phase change mass transfer at the liquid-vapor interface. Computational results are compared to the data provided by a non-isothermal sloshing experiment with phase change conducted by the University of Tokyo and JAXA in 2018 using liquid Nitrogen in a transparent tank. The effect of different thicknesses of a liquid temperature stratification layer created at the interface on the pressure drop during sloshing was studied experimentally. CFD results for interface movement and tank pressure are presented and compared in this paper to experimental data for the cases with the smallest and largest liquid temperature stratification thickness.

phase change↗