Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Identification of Noise Sources in a Rocket Engine Test Stand using Microphone Phased Array

A new, phased array of microphones, suitable for the harsh environment of a rocket launch, was built and tested during a static firing of a RS-25 engine. It uses 70 piezo-resistive, dynamic pressure sensors, optimally distributed on a 10.5ft diameter open frame dome structure, and has a 200-ft long cable bundle to carry the signals to a weather-protected cabinet containing the data systems. The test stand was imaged using an infra-red camera and a visible wavelength camera, and the beamformed noise maps were superimposed on the photographs. The first-time data from a full-scale engine test stand showed that the plume deflector at the bottom of the engine to be the primary noise source. The openings of the test stand around the nozzle exit were also found to be noise sources particularly at higher frequencies. The final goal is to use the array during NASA’s Artemis-II launch at Kennedy Space Center.

Identification of Noise Source↗

Space Launch System: SLS Real Time Rollout Monitoring for MPCV

The NASA Space Launch System (SLS) rocket, Orion spacecraft, and Mobile Launcher (ML) are transported to Pad 39B from the Vehicle Assembly Building on a large, tracked vehicle known as the Crawler Transporter (CT). The CT is a holdover from the Apollo and Space Shuttle programs but has been extensively upgraded to accommodate the SLS. The Dynamic Rollout Test (DRT) on March 17, 2022 marked the first full rollout of the SLS and ML. Analysis indicated that loads and vibrations would be well below design limits, but out of an abundance of caution it was decided to monitor the response in real time during the rollout to assure that loads remained within predicted limits. This first rollout was outfitted with extensive test instrumentation such as accelerometers, pressure sensors, and strain gauges. This instrumentation remained in place following the integrated vehicle modal test and was being used for additional Operational Modal Analysis (OMA) during the rollout in addition to the real-time monitoring. This presentation discusses the specific loads and accelerations monitored during the rollout, how and why those responses were chosen, and how the system was implemented. Finally, a post-rollout loads reconstruction is used to assess the process and the analysis tools used for the rollout analysis.

SLS↗

Space Launch System Artemis I Ascent Loads Reconstruction Summary

On November 16, 2022, NASA successfully launched the Space Launch System (SLS) rocket and Orion spacecraft for the first SLS mission, Artemis 1. This first flight was outfitted with Developmental Flight Instrumentation (DFI) such as accelerometers, pressure sensors, and strain gauges. The DFI supports many post-flight activities, one of which is the ascent loads reconstruction effort. The integrated vehicle ascent loads spans both boost phase and Core phase and often produces the largest loads experienced by the vehicle during flight. One of the primary goals of the ascent loads reconstruction is to evaluate applicable Coupled Loads Analysis (CLA) design math models, assumptions, and analysis methodologies. To achieve this goal, all significant ascent subevents have been reconstructed through the use of flight data, reconstructed inputs, and existing CLA simulations. Resulting responses have been compared to available flight measurements. Additionally, reconstructed subevent loads were combined and compared to appropriate flight data and pre-flight predictions.

SLS↗

Exploring Cryogenic Propellant Behavior in Low-Gravity Environments, Insights from the Saturn AS-203 Vent Experiments and CFD Analysis

In the 1960s, NASA embarked on a series of groundbreaking flight tests on the Saturn AS-203, aiming to understand the complex dynamics of propellants in the distinctive low-gravity lunar environment. These tests centered on venting experiments, subjecting cryogenic liquid hydrogen to conditions beneath its saturation pressure while accelerating the vehicle to manage the propellant's positioning. During these experiments, NASA meticulously scrutinized the propellant tank using a suite of instruments, including temperature and pressure sensors, as well as a camera placed internal to the liquid hydrogen tank. The outcomes provided anecdotal evidence revealing the phenomenon of boiling along the tank's walls and the intriguing formation of liquid globules and droplets in the ullage during the venting process. Notably, the substantial drop in liquid temperature during these tests suggests adiabatic cooling as liquid hydrogen evaporates. This evaporation leads to a cooling of the remaining hydrogen due to the heat it releases. This paper presents the outcomes of our initial analysis, wherein CFD models were used to simulate the observed boiling phenomena and the bulk movement of the liquid hydrogen propellant, both qualitatively and quantitatively. The implications of these findings may extend to mission and vehicle designers, providing invaluable insights for crafting more efficient and effective in-space propulsion systems utilizing cryogenic propellant including impacts to vehicle control systems. Understanding propellant behavior under these conditions may better inform GNC teams, ensuring more stable vehicle operations when utilizing cryogenic propellants. This includes essential considerations for cryogenic propellant transfer and storage systems, integral to NASA's forthcoming Artemis missions. While we recognize the challenges tied to CFD models, this study represents a step forward, highlighting current progress and signaling the potential for refining our predictive understanding in the future.

Computational Fluid Dynamics↗

Exploring Cryogenic Propellant Behavior in Low-Gravity Environments, Insights from the Saturn AS-203 Vent Experiments and CFD Analysis

In the 1960s, NASA embarked on a series of groundbreaking flight tests on the Saturn AS-203, aiming to understand the complex dynamics of propellants in the distinctive low-gravity lunar environment. These tests centered on venting experiments, subjecting cryogenic liquid hydrogen to conditions beneath its saturation pressure while accelerating the vehicle to manage the propellant's positioning. During these experiments, NASA meticulously scrutinized the propellant tank using a suite of instruments, including temperature and pressure sensors, as well as a camera placed internal to the liquid hydrogen tank. The outcomes provided anecdotal evidence revealing the phenomenon of boiling along the tank's walls and the intriguing formation of liquid globules and droplets in the ullage during the venting process. Notably, the substantial drop in liquid temperature during these tests suggests adiabatic cooling as liquid hydrogen evaporates. This evaporation leads to a cooling of the remaining hydrogen due to the heat it releases. This paper presents the outcomes of our initial analysis, wherein CFD models were used to simulate the observed boiling phenomena and the bulk movement of the liquid hydrogen propellant, both qualitatively and quantitatively. The implications of these findings may extend to mission and vehicle designers, providing invaluable insights for crafting more efficient and effective in-space propulsion systems utilizing cryogenic propellant including impacts to vehicle control systems. Understanding propellant behavior under these conditions may better inform GNC teams, ensuring more stable vehicle operations when utilizing cryogenic propellants. This includes essential considerations for cryogenic propellant transfer and storage systems, integral to NASA's forthcoming Artemis missions. While we recognize the challenges tied to CFD models, this study represents a step forward, highlighting current progress and signaling the potential for refining our predictive understanding in the future.

Computational Fluid Dynamics↗

Towards Quantifying and Correlating RTV Intumescence to Entry-Relevant Conditions

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also adopted to bond instrumentation plugs of temperature and pressure sensors into heatshield’s tiles. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Experimental data has also shown heating rate-dependent swelling (or intumescence) and shrinking of RTV, these volume changes may cause roughness-induced boundary layer transition. Outgassing and surface oxide formation of RTV upon decomposition also occur, which can be sources of contamination of heat shield sensors. This combination of detrimental effects motivates a critical need to develop a high-fidelity model for RTV ablation. As a first critical step in RTV modeling, a comprehensive material properties database for RTV was collected that account for the lack of data in properties such as pyrolysis char yield, shape change, virgin and char porosity. The next step is to quantify the volume change of RTV as a function of temperature. While this was done in previous campaigns, limited data was collected which showed a possible heating rate dependent intumescent behavior. To further understand the intumescence phenomenon of RTV, numerous dedicated experiments were performed at Beamline 8.3.2 of the Advanced Light Source, where RTV samples were heated while X-ray scans were taken in situ. Micro-Computed Tomography scans were taken in situ for low heating rates (≤ 60 °C/min), whereas continuous radiography scans were taken for higher heating rates (≤ 1500 ºC/min). Unconstrained samples and samples constrained in different holders (quartz, graphite, FiberForm and PICA) were tested to determine the change in intumescence due to confinement. Using deep learning techniques, the tomographies and radiographies are segmented to obtain volume change, porosity, pore size distributions and connectivity. From the results obtained, modifications to the previous RTV intumescence model are proposed, along with preliminary comparisons to testing RTV at high-enthalpy facilities.

RTV↗

Ultrasonic level sensors for liquids under high pressure

An ultrasonic level sensor of novel design continuously measures the level of a liquid subjected to a high pressure (up to about 40 MPa), as is sometimes required for the effective transfer of the liquid. The sensor operates as a composite resonator fabricated from a standard high-pressure plug. A flat-bottom hole is machined into the plug along its center line. An ultrasonic transducer is bonded rigidly to the interior surface of the bottom wall, while the exterior surface is in contact with the liquid. Although the bottom wall is designed to satisfy the pressure code, it is still sufficiently thin to permit ready excitation of the axisymmetric plate modes of vibration. The liquid level is measured by a conventional pulse-echo technique. A prototype sensor was tested successfully in a 2300-l water vessel at pressures up to about 37 MPa. A spectral analysis of the transmitted pulse reveals that the flexural, extensional, thickness-shear, and radial plate modes are excited into vibration, but none of these appears to be significantly affected by the pressurization of the liquid.

Zuckerwar, A. J.↗

Continuous-Reading Cryogen Level Sensor

Two pressure transducers used in system for measuring amount of cryogenic liquid in tank. System provides continuous measurements accurate within 0.03 percent. Sensors determine pressure in liquid and vapor in tank. Microprocessor uses pressure difference to compute mass of cryogenic liquid in tank. New system allows continuous sensing; unaffected by localized variations in composition and density as are capacitance-sensing schemes.

Barone, F. E.↗

Post-flight Analysis of Mars Science Laboratory Entry Aerothermal Environment and Thermal Protection System Response

The Mars Science Laboratory successfully landed on the Martian surface on August 5th, 2012. The rover was protected from the extreme heating environments of atmospheric entry by an ablative heatshield. This Phenolic Impregnated Carbon Ablator heatshield was instrumented with a suite of embedded thermocouples, isotherm sensors, and pressure transducers. The sensors monitored the in-depth ablator response, as well as the surface pressure at discrete locations throughout the hypersonic deceleration. This paper presents a comparison of the flight data with post-entry estimates. An assessment of the aerothermal environments, as well as the in-depth response of the heatshield material is made, and conclusions regarding the overall performance of the ablator at the suite locations are presented.

mars science laboratory↗

Fiber-optic interferometric sensors for measurements of pressure fluctuations - Experimental evaluation

A fiber optic interferometric sensor that is being developed at NASA Ames Research Center for pressure fluctuation measurements in wind tunnels is considered. Preliminary evaluation indicates that the fiber optic interferometric sensor can be successfully used as an aeroacoustic sensor and is capable of providing a powerful instrument to solve complex acoustic measurement problems in wind tunnels.

Cho, Y. C.↗

NASA Tech Briefs, July 2008

Topics covered include: Torque Sensor Based on Tunnel-Diode Oscillator; Shaft-Angle Sensor Based on Tunnel-Diode Oscillator; Ground Facility for Vicarious Calibration of Skyborne Sensors; Optical Pressure-Temperature Sensor for a Combustion Chamber; Impact-Locator Sensor Panels; Low-Loss Waveguides for Terahertz Frequencies; MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices; Low-Temperature Supercapacitors; Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers; Compact, Single-Stage MMIC InP HEMT Amplifier; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Improved Sand-Compaction Method for Lost-Foam Metal Casting; Improved Probe for Evaluating Compaction of Mold Sand; Polymer-Based Composite Catholytes for Li Thin-Film Cells; Using ALD To Bond CNTs to Substrates and Matrices; Alternating-Composition Layered Ceramic Barrier Coatings; Variable-Structure Control of a Model Glider Airplane; Axial Halbach Magnetic Bearings; Compact, Non-Pneumatic Rock-Powder Samplers; Biochips Containing Arrays of Carbon-Nanotube Electrodes; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Neon as a Buffer Gas for a Mercury-Ion Clock; Miniature Incandescent Lamps as Fiber-Optic Light Sources; Bidirectional Pressure-Regulator System; and Prism Window for Optical Alignment. Single-Grid-Pair Fourier Telescope for Imaging in Hard-X Rays and gamma Rays Range-Gated Metrology with Compact Optical Head Lossless, Multi-Spectral Data Compressor for Improved Compression for Pushbroom-Typetruments.

Source record↗

Engineering a laser remote sensor for atmospheric pressure and temperature

A system for the remote sensing of atmospheric pressure and temperature is described. Resonant lines in the 7600 Angstrom oxygen A band region are used and an organic dye laser beam is tuned to measure line absorption changes with temperature or pressure. A reference beam outside this band is also transmitted for calibration. Using lidar techniques, profiling of these parameters with altitude can be accomplished.

Kalshoven, J. E., Jr.↗

Improved Fiber-Optic-Coupled Pressure And Vibration Sensors

Improved fiber-optic coupler enables use of single optical fiber to carry light to and from sensor head. Eliminates problem of alignment of multiple fibers in sensor head and simplifies calibration by making performance both more predictable and more stable. Sensitivities increased, sizes reduced. Provides increased margin for design of compact sensor heads not required to contain amplifier circuits and withstand high operating temperatures.

Zuckerwar, Allan J.↗

Ground Test Stand Development for One-step Electrochemical Production of High-Pressure Oxygen

NASA designed a test rig, High-Pressure Oxygen Generation Assembly (HPOGA) to test a novel method of electrolysis as an alternative technology to the state-of-the-art Oxygen Generation Assembly (OGA) currently on the International Space Station (ISS). This approach involves utilizing a specialized electrolysis cell stack designed to both generate and compress high-pressure oxygen up to 3600 PSIG. The design eliminates the need for an external compressor and hydrogen separator, streamlining the oxygen generation process. HPOGA tests the viability of an electrolysis cell stack for extended life usage. Within the system, there are several key subsystems: nitrogen, high/low pressure oxygen, hydrogen, water recirculation, and water injection. The water injection subsystem supplies deionized (DI) water to a centralized reservoir for consumption. Subsequently, a water recirculation loop transfers the DI water across the cathode side of the electrolysis cell stack with constant flow rate. The result is a supply of hydrogen in the water loop and oxygen accumulation on the anode side of the cell stack. Hydrogen is evaporated out as part of the hydrogen sub-system which also measures hydrogen/oxygen concentration for safety. The oxygen subsystem is responsible for managing high pressure oxygen, O2 exhaust, and conducting hydrogen/oxygen concentration measurements. The nitrogen subsystem serves dual functions, purging the hydrogen/oxygen subsystems, and regulating pressure in both high/low-pressure O2 sections via pneumatic back pressure regulators. Various sensors monitor pressure, temperature, humidity, gas concentration and flow rate in each subsystem. This paper presents the design and testing of a comprehensive test stand, which serves to operate and functionally verify the performance of the electrolysis cell while offering valuable lessons learned.

electrolysis↗

Prediction of Composite Pressure Vessel Failure Location using Fiber Bragg Grating Sensors

Ten composite pressure vessels were instrumented with fiber Bragg grating sensors in order to assess the strain levels of the vessel under various loading conditions. This paper and presentation will discuss the testing methodology, the test results, compare the testing results to the analytical model, and present a possible methodology for predicting the failure location and strain level of composite pressure vessels.

Kreger, Steven T.↗

Methods and Systems for Configuring Sensor Acquisition Based on Pressure Steps

Technologies are provided for underwater measurements. A system includes an underwater vessels including: a plurality of sensors disposed thereon for measuring underwater properties; and a programmable controller configured to selectively activate the plurality of sensors based at least in part on underwater pressure. A user may program at what pressure ranges certain sensors are activated to measure selected properties, and may also program the ascent/descent rate of the underwater vessel, which is correlated with the underwater pressure.

DeDonato, Mathew↗

Development of a Portable Oxygen Monitoring System for Operations in the International Space Station Airlock

NASA is currently engaged in an activity to facilitate effective operations on the International Space Station (ISS) after the Space Shuttle retires. Currently, the Space Shuttle delivers crew and cargo to and from ISS. The Space Shuttle provides the only large scale method of hardware return from ISS to the ground. Hardware that needs to be periodically repaired, refurbished, or recalibrated must come back from ISS on the Shuttle. One example of NASA flight hardware that is used on ISS and refurbished on the ground is the Compound Specific Analyzer for Oxygen (CSA-O2). The CSA-O2 is an electrochemical sensor that is used on orbit for about 12 months (depending on Shuttle launch schedules), then returned to the ground for sensor replacement. The shuttle is scheduled to retire in 2010, and the ISS is scheduled to operate until 2016. NASA needs a hand held sensor that measures oxygen in the ISS environment and has a 5-10 year service life. After conducting a survey of oxygen sensor systems, NASA selected a Tunable Diode Laser Absorption Spectrometer (TDLAS) as the method of measurement that best addresses the needs for ISS. These systems are compact, meet ISS accuracy requirements, and because they use spectroscopic techniques, the sensors are not consumed or altered after making a measurement. TDLAS systems have service life ratings of 5-10 years, based on the lifetime of the laser. NASA is engaged in modifying a commercially available sensor, the Vaisala OMT 355, for the ISS application. The Vaisala OMT 355 requires three significant modifications to meet ISS needs. The commercial sensor uses a wall mount power supply, and the ISS sensor needs to use a rechargeable battery as its source of power. The commercial sensor has a pressure correction setpoint: the sensor can be adjusted to operate at reduced pressure conditions, but the sensor does not self correct dynamically and automatically. The ISS sensor needs to operate in the airlock, and make accurate measurements in an environment that can change from 14.7 psia to 10.2 psia in 15 minutes. The commercial sensor needs to be repackaged into a configuration that is more compact, and better suited for ISS airlock operations. NASA has recently completed a prototype of the reconfigured system. The unit has been repackaged in a way that the optical path of the spectrometer is unchanged, but the electronics has been integrated into a case measuring 10.7 X 7.2 X 3.0 inches. Two flight qualified rechargeable batteries have been integrated into system. The batteries can power the sensor for 10 hours on a single charge. A pressure sensor has been added to the system. The modified unit automatically compensates for changes in pressure, and meets 0.2% accuracy requirements for oxygen measurements in an environment with 18 to 32% oxygen across a pressure range of 10.0 to 15.0 psia.

Graf, John↗