Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototype specifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Advanced QPSK Optical Modulators Using Lithium Niobate Thin Films (Final Scientific Report)

Lithium niobate thin film based optical modulator devices have been produced using this SBIR award. A bonding apparatus was developed that was used to bond lithium niobate to silicon at room temperature. The bonding apparatus was designed, assembled and qualified for production of thin film substrates. The optical properties of ion sliced thin films produced using this bonding apparatus was optimized to achieve low loss optical waveguides. Optical grating coupler and other component of the proposed optical modulator were designed. Preliminary results show the proposed method for making optical modulator meets the required customer specifications. All the required process steps for manufacturing of the devices were developed and optimized. Further funding is required to make a final prototype device that can be provided to customers.

36 MATERIALS SCIENCE↗

Automated Mini-Tubular Ceramic Production (Final Design Review)

Researchers at Lawrence Livermore National Laboratory need a way to increase the rate of manufacturing of mini-tubular ceramics to be used in testing particulate air filters. This document outlines our process from researching and writing an initial scope of work all the way to fabricating and testing a final prototype. This journey takes us through the background research, ideation process and selection of a final design. We also detail the desired engineering specifications and our concept selection process. We dedicate a significant portion of this report to discussion of our final design. We delve into how it was manufactured as well as the tests we performed and its successes and failures. We also propose potential areas for further development and next steps for sponsors. Overall, this document provides the reader with a comprehensive understanding of our design process and results.

36 MATERIALS SCIENCE↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

Multi-element Neutron Energy Spectrometer

In the area of nuclear radiological emergency response and preparedness applications, interest in neutron detection stems from several factors. Unlike gamma rays, which are abundant in nature and present serious difficulties in differentiating a signal from a changing background, whose values are location specific, neutrons are rare and nearly homogenous in spatial distribution. Additionally, many special nuclear materials (SNM) emit neutrons either directly by spontaneous fission or produce neutrons indirectly through (α, n) reactions in nearby light elements. Also of importance in detection scenarios is the fact that neutrons are not easily attenuated. Typically neutron detection is done by simply counting the low energy thermal neutrons by employing pressurized helium tubes operated at high voltages. Not much emphasis is put on determining the energy of the incident neutrons. However, critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the detection of an SNM, neutron energy information from an unknown source can be of paramount importance. We have modeled, designed, and prototyped multi-element neutron energy spectrometers that contain three to five pressurized helium tubes of dimensions 2" diam. x 10" in length. Each individual helium tube has a specific amount of high density plastic neutron moderators to slow down the incident energetic neutrons to an accurately estimated energy. A typical spectrometer is a set of moderator cylinders surrounding detectors that have high efficiency for detecting thermal neutrons. The larger the moderator, the higher the energy of incident neutrons for which the detector assembly has matched detection efficiency. If all the detectors are exposed to the same radiation field and the efficiency as a function of energy (response function) of each of the detectors is known, the neutron energy spectrum can be determined from the detector count rates. Monte Carlo simulation results of response function calculations for different arrays of helium tubes with varying amount of moderators will be shown. Experimental evidence of effectiveness of a set of moderated helium tubes to measure the hardness of the incident neutrons will be demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MICRO-SEISMOMETERS VIA ADVANCED MESO-SCALE FABRICATION

The Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) seek revolutionary sensing innovations for the monitoring of nuclear detonations. Performance specifications are to be consistent with those obtainable by only an elite few products available today, but with orders of magnitude reduction in size, weight, power, and cost. The proposed commercial innovation calls upon several technologies including the combination of meso-scale fabrication and assembly, photonics-based displacement / motion detection methods, and the use of digital control electronics . Early Phase II development has demonstrated verified and repeatable sub 2ng noise floor from 3Hz to 100Hz, compact integration of 3-axis prototypes, and robust deployment exercises. Ongoing developments are focusing on low frequency challenges, low power consumption, ultra-miniature size, and low cross axis sensitivity. We are also addressing the rigorous set of specifications required for repeatable and reliable long-term explosion monitoring, including thermal stability, reduced recovery time from mass re-centering and large mechanical shocks, sensitivity stability, and transportability. Successful implementation will result in small, hand-held demonstration units with the ability to address national security needs of the DOE/NNSA. Additional applications envisioned include military/defense, scientific instrumentation, oil and gas exploration, inertial navigation, and civil infrastructure monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The entrance system laboratory prototype for an advanced mass and ionic charge composition experiment

Electrostatic analyzers (ESA) have been used extensively for the characterization of plasmas in a variety of space environments. They vary in shape, geometry, and size and are adapted to the specific particle population to be measured and the configuration of the spacecraft. Their main function is to select the energy per charge of the particles within a passband. An energy-per-charge range larger than that of the passband can be sampled by varying the voltage difference between the ESA electrodes. The voltage sweep takes time and reduces the duty cycle for a particular energy-per-charge passband. Our design approach for an advanced mass and ionic charge composition experiment (AMICCE) has a novel electrostatic analyzer that essentially serves as a spectrograph and selects ions simultaneously over a broad range of energy-per-charge (E/q). Only three voltage settings are required to cover the entire range from {approx}10 to 270 keV/q, thus dramatically increasing the product of the geometric factor times the duty cycle when compared with other instruments. In this paper, we describe the AMICCE concept with particular emphasis on the prototype of the entrance system (ESA and collimator), which we designed, developed, and tested. We also present comparisons of the laboratory results with electrostatic simulations.

42 ENGINEERING↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗

Note: A simple vibrating orifice monodisperse droplet generator using a hard drive actuator arm

We propose that the rotary voice coil actuators found in magnetic hard drives are fit to supercede loudspeakers as expedient vibration sources in the laboratory setting. A specific use case is the excitation of a liquid jet to induce controlled breakup into monodisperse droplets. Like loudspeakers, which are typically used for prototyping such devices, hard drive actuators are cheap and ubiquitous, but they are less unwieldy and supply greater amplitudes without producing noise. Frequencies between 0 and 17 kHz, and likely beyond, can be reproduced reliably. No machining tools or amplifying electronics are needed for the construction and operation of the presented droplet generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge transfer interactions in oligomer coated gold nanoclusters

Gold nanoclusters were synthesized by a bottom-up synergistic approach of in-situ oligomerization of the monomer, N-vinyl pyrrolidone (NVP) and simultaneous weak reduction of Au-NVP complexes in the absence of any other external energy sources, thereby making these tiny gold clusters as the most elemental building blocks to construct further novel nano/microstructures with application potentials. It is well-known that metal clusters with less than 2 nm size do not show the usual surface plasmon band, because of the presence of a band-gap at the fermi level. Nevertheless, our present oligomer coated gold clusters show a discrete intense band at around 630 nm, which could very well be attributed to the charge transfer between the oligomer chain and the surface Au atoms. Such kind of sacrificial plasmon induced charge transfer interaction, observed for the very first time to the best of our knowledge, were also strongly corroborated through the enhancement / shifting of specific vibrational / rotational peaks as observed from the FTIR and Raman measurements as a function of the metal oxidation states, thus representing a new prototype for an efficient solar energy conversion probe.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Oxygen vacancy formation energies in PbTiO 3 / SrTiO 3 superlattice

The defect stability in a prototypical perovskite oxide superlattice consisting of ${\mathrm{SrTiO}}_{3}$ and ${\mathrm{PbTiO}}_{3}$ (STO/PTO) is determined by using first principles density functional theory calculations. Specifically, the oxygen vacancy formation energies ${E}_{\mathrm{v}}$ in the paraelectric and ferroelectric phases of a superlattice with four atomic layers of STO and four layers of PTO (4STO/4PTO) are determined and compared. The effects of charge state, octahedral rotation, polarization, and interfaces on ${E}_{\mathrm{v}}$ are examined in this paper. The formation energies vary layer by layer in the superlattices, with ${E}_{\mathrm{v}}$ being higher in the ferroelectric phase than that in the paraelectric phase. The two interfaces constructed in these oxide superlattices, which are symmetrically equivalent in the paraelectric systems, exhibit very different formation energies in the ferroelectric superlattices and this can be seen to be driven by the coupling of ferroelectric and rotational modes. At equivalent lattice sites, ${E}_{\mathrm{v}}$ of charged vacancies is generally lower than that of neutral vacancies. Octahedral rotations $({\mathrm{a}}^{0}{\mathrm{a}}^{0}{\mathrm{c}}^{{-}})$ in the superlattices have a significant effect on ${E}_{\mathrm{v}}$, increasing the formation energy of vacancies located near the interface but decreasing the formation energy of the oxygen vacancies located in the bulk-like regions of the STO and PTO constituent parts. The formation-energy variations among different layers are found to be primarily caused by the difference in the local relaxation at each layer. Finally, these fundamental insights into the defect stability in perovskite superlattices can be used to tune defect properties by controlling the constituent materials of superlattices and interface engineering.

36 MATERIALS SCIENCE↗

Synthesizing Virtual Oscillators to Control Islanded Inverters

Virtual oscillator control (VOC) is a decentralized control strategy for islanded microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. Compared to droop control, which is only well defined in sinusoidal steady state, VOC is a time-domain controller that enables interconnected inverters to stabilize arbitrary initial conditions to a synchronized sinusoidal limit cycle. However, the nonlinear oscillators that are elemental to VOC cannot be designed with conventional linear-control design methods. We address this challenge by applying averaging- and perturbation-based nonlinear analysis methods to extract the sinusoidal steady-state and harmonic behavior of such oscillators. The averaged models reveal conclusive links between real- and reactive-power outputs and the terminal-voltage dynamics. Similarly, the perturbation methods aid in quantifying higher order harmonics. The resultant models are then leveraged to formulate a design procedure for VOC such that the inverter satisfies standard ac performance specifications related to voltage regulation, frequency regulation, dynamic response, and harmonic content. Experimental results for a single-phase 750 VA, 120 V laboratory prototype demonstrate the validity of the design approach. They also demonstrate that droop laws are, in fact, embedded within the equilibria of the nonlinear-oscillator dynamics. This establishes the backward compatibility of VOC in that, while acting on time-domain waveforms, it subsumes droop control in sinusoidal steady state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Validation of Subsystem Models for a Novel Variable Displacement Hydraulic Motor

A novel, variable displacement, low-speed high-torque hydraulic motor is being developed that is expected to be highly efficient across a broad operating range. To ensure the final hardware achieves the expected performance, the models used in the development of the motor must be experimentally validated and revised, as necessary. The specific focus in this work is on mechanical energy loss models that were used to guide the design of a single-cylinder motor prototype and on experimental tests used for model validation. Ideally each model, whether friction loss in a piston/cylinder interface or energy loss due to leakage in a valve , would be individually validated by an independent test. This granular approach would remove any question of where the error lies and result in highly accurate models. However, many motor components have multiple forms of energy loss, creating difficulty in validating individual losses. Additionally, it is not physically realizable to divide many components into an individual model equivalent test. Testing the motor as a full assembly is possible, but pinpointing the source of discrepancies between the model and the hardware becomes difficult with dozens of models potentially being partially responsible. A compromise was found by separating the motor into functional component groups that are characterized by the type of loss and ability to test each subcomponent independently. By checking for correlation between test observations and model predictions, revisions could be implemented into the models. This allows future solutions to be more accurately predicted in the design phase to drive the design of better machines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and evaluation of the MAMMI dedicated breast PET

Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV-750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPi User Manual V0.1

This document describes the Serial Powering Interface (SPi) ASIC. SPi is a general purpose ASIC prototype designed for use in serial powering of silicon detector instrumentation. This description is written as a user manual to aid application, not as a design description. SPi is a generic custom ASIC, manufactured in 0.25 {mu}m CMOS by TSMC, to interface between a constant current source and silicon detector read-out chips. There is no SEU (single event upset) protection, but most (not all) components are radiation tolerant design. An operating voltage of 1.2 to 2.5 volts and other design features make the IC suitable for a variety of serial powering architectures and ROICs. It should be noted that the device is likely to be a prototype for demonstration rather than a product for inclusion in a detector. The next design(s), SPin, are likely to be designed for a specific application (eg SLHC). The component includes: (1) Seven bi-directional LVDS-like buffers for high data rate links to/from the read-out chips. These are AC coupled (series capacitor) off-chip for DC level conversion; (2) A programmable internal programmable shunt regulator to provide a defined voltage to readout chips when linked in a serial powering chain; (3) A programmable internal shunt regulator control circuit for external transistor control; (4) Shunt current measurement (for internal shunt regulator); (5) A programmable internal shunt regulator current alarm; and (6) Two programmable linear regulators.

43 PARTICLE ACCELERATORS↗

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

We have built a prototype germanium detector with a Compton veto that is optimized for high sensitivity in the low-energy range around ~100 keV. It is specifically designed to address the problem to directly detect plutonium gamma emissions in spent nuclear fuel by non-destructive assay. This is not possible with current detectors due to the large low-energy background of Compton-scattered high-energy radiation from the fission products, whose gamma flux is at least 6 to 7 orders of magnitude higher than the Pu signal. Our instrument is designed to assess the feasibility to selectively suppress the background in the low-energy region around ~100 keV with the strongest Pu X-ray and gamma emissions lines. It employs a thin Ge detector with a large Compton veto directly behind it to suppress the background from forward-scattered radiation by anti-coincidence vetoing. This report summarizes the design considerations and the performance of the instrument.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Majorana Electroformed Copper Mechanical Analysis

The MAJORANA DEMONSTRATOR is a large array of ultra-low background high-purity germanium detectors, enriched in 76 Ge, designed to search for zero-neutrino double-beta decay. The DEMONSTRATOR will utilize ultra high purity electroformed copper for a variety of detector components and shielding. A preliminary mechanical evaluation was performed on the Majorana prototype electroformed copper material. Several samples were removed from a variety of positions on the mandrel. Tensile testing, optical metallography, scanning electron microscopy, and hardness testing were conducted to evaluate mechanical response. Analyses carried out on the Majorana prototype copper to this point show consistent mechanical response from a variety of test locations. Evaluation shows the copper meets or exceeds the design specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Viscosity Meaurement Technique for Metal Fuels

Metallic fuels have exceptional transient behavior, excellent thermal conductivity, and a more straightforward reprocessing path, which does not separate out pure plutonium from the process stream. Fabrication of fuel containing minor actinides and rare earth (RE) elements for irradiation tests, for instance, U-20Pu-3Am-2Np-1.0RE-15Zr samples at the Idaho National Laboratory, is generally done by melt casting in an inert atmosphere. For the design of a casting system and further scale up development, computational modeling of the casting process is needed to provide information on melt flow and solidification for process optimization. Therefore, there is a need for melt viscosity data, the most important melt property that controls the melt flow. The goal of the project was to develop a measurement technique that uses fully sealed melt sample with no Americium vapor loss to determine the viscosity of metallic melts and at temperatures relevant to the casting process. The specific objectives of the project were to: develop mathematical models to establish the principle of the measurement method, design and build a viscosity measurement prototype system based on the established principle, and calibrate the system and quantify the uncertainty range. The result of the project indicates that the oscillation cup technique is applicable for melt viscosity measurement. Detailed mathematical models of innovative sample ampoule designs were developed to not only determine melt viscosity, but also melt density under certain designs. Measurement uncertainties were analyzed and quantified. The result of this project can be used as the initial step toward the eventual goal of establishing a viscosity measurement system for radioactive melts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultra-Compact High Efficiency Multi-Level Gan-Based PV Inverter

This project developed the key technology for a scalable, high-density photovoltaic (PV) inverter, based on gallium-nitride (GaN) power semiconductors, and advanced digital control. Specifically, we explored the feasibility of a flying-capacitor multi-level inverter for 1.5 kV PV installations, through the development of hardware prototypes utilizing low-inductance commutation loop designs, robust digital control and signaling, and low-cost heatsink integration.

14 SOLAR ENERGY↗