Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Discovery of a 7 mHz X-Ray Quasi-Periodic Oscillation from the Most Massive Stellar-Mass Black Hole IC 10 X-1

We report the discovery with XMM-Newton of an approx.. = 7 mHz X-ray (0.3-10.0 keV) quasi-periodic oscillation (QPO) from the eclipsing, high-inclination black hole binary IC 10 X-1. The QPO is significant at >4.33 sigma confidence level and has a fractional amplitude (% rms) and a quality factor, Q is identical with nu/delta nu, of approx. = 11 and 4, respectively. The overall X-ray (0.3-10.0 keV) power spectrum in the frequency range 0.0001-0.1 Hz can be described by a power-law with an index of approx. = −2, and a QPO at 7 mHz. At frequencies approx. > 0.02 Hz there is no evidence for significant variability. The fractional amplitude (rms) of the QPO is roughly energy-independent in the energy range of 0.3-1.5 keV. Above 1.5 keV the low signal-to-noise ratio of the data does not allow us to detect the QPO. By directly comparing these properties with the wide range of QPOs currently known from accreting black hole and neutron stars, we suggest that the 7 mHz QPO of IC 10 X-1 may be linked to one of the following three categories of QPOs: (1) the "heartbeat" mHz QPOs of the black hole sources GRS 1915+105 and IGR J17091−3624, or (2) the 0.6-2.4 Hz "dipper QPOs" of high-inclination neutron star systems, or (3) the mHz QPOs of Cygnus X-3.

Oscillation↗

RBE of Energetic Iron Ions for the Induction of Early and Late Chromosome Aberrations in Different Cell Types

Numerous published studies have reported the RBE values for chromosome chromosomes induced by charged particles of different LET. The RBE for chromosome aberrations in human lymphocytes exposed ex vivo showed a similar relationship as the quality factor for cancer induction. Consequently, increased chromosome aberrations in the astronauts' white blood cells post long-duration missions are used to determine the biological doses from exposures to space radiation. The RBE value is known to be very different for different types of cancer. Previously, we reported that the RBE for initial chromosome damages was high in human lymphocytes exposed to Fe ions. After multiple cell divisions post irradiation, the RBE was significantly smaller. To test the hypothesis that the RBE values for chromosome aberrations are different between early and late damages and also different between different cell types, we exposed human lymphocytes ex vivo, and human fibroblast cells and human mammary epithelial cells in vitro to 600 MeV/u Fe ions. Post irradiation, the cells were collected at first mitosis, or cultured for multiple generations for collections of remaining or late arising chromosome aberrations. The chromosome aberrations were quantified using fluorescent in situ hybridization (FISH) with whole chromosome specific probes. This study attempts to offer an explanation for the varying RBE values for different cancer types.

Zhang, Ye↗

RBE of Energetic Iron Ions for the Induction of Early and Late Chromosome Aberrations in Different Cell Types

Numerous published studies have reported the Relative Biological Effectiveness (RBE) values for chromosome aberrations induced by charged particles of different LET. The RBE for chromosome aberrations in human lymphocytes exposed ex vivo has been suggested to show a similar relationship as the quality factor for cancer induction. Therefore, increased chromosome aberrations in the astronauts' white blood cells post long-duration missions are used to determine the biological doses from exposures to space radiation. However, the RBE value is known to be very different for different types of cancer. Previously, we reported that, even though the RBE for initial chromosome damages was high in human lymphocytes exposed to Fe ions, the RBE was significantly reduced after multiple cell divisions post irradiation. To test the hypothesis that RBE values for chromosome aberrations are cell type dependent, and different between early and late damages, we exposed human lymphocytes ex vivo, and human mammary epithelial cells in vitro to various charged particles. Chromosome aberrations were quantified using the samples collected at first mitosis post irradiation for initial damages, and the samples collected after multiple generations for the remaining or late arising aberrations. Results of the study suggested that the effectiveness of high-LET charged particles for late chromosome aberrations may be cell type dependent, even though the RBE values are similar for early damages.

Zhang, Ye↗

A Reference Field for GCR Simulation and an LET-Based Implementation at NSRL

Exposure to galactic cosmic rays (GCR) on long duration deep space missions presents a serious health risk to astronauts, with large uncertainties connected to the biological response. In order to reduce the uncertainties and gain understanding about the basic mechanisms through which space radiation initiates cancer and other endpoints, radiobiology experiments are performed. Some of the accelerator facilities supporting such experiments have matured to a point where simulating the broad range of particles and energies characteristic of the GCR environment in a single experiment is feasible from a technology, usage, and cost perspective. In this work, several aspects of simulating the GCR environment in the laboratory are discussed. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at the NASA Space Radiation Laboratory (NSRL) limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is within physical uncertainties, allowing a single reference field for deep space missions to be defined. Third, an approach for simulating the reference field at NSRL is presented. The approach allows for the linear energy transfer (LET) spectrum of the reference field to be approximately represented with discrete ion and energy beams and implicitly maintains a reasonably accurate charge spectrum (or, average quality factor). Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the proposed strategy are discussed in this context.

Slaba, Tony C.↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗

Kelt-16b: A Highly Irradiated, Ultra-Short Period Hot Jupiter Nearing Tidal Disruption

We announce the discovery of KELT-16b, a highly irradiated, ultra-short period hot Jupiter transiting the relatively bright (visual magnitude equals 11.7) star TYC 2688-1839-1/KELT-16. A global analysis of the system shows KELT-16 to be an F7V star with effective temperature equal to 6236 plus or minus 54 degrees Kelvin, log g (sub asterisk) equal to 4.253 from plus 0.031 to minus 0.036, [Fe/H] equal to minus 0.002 from plus 0.086 to minus 0.085, mass (sub asterisk) equal to 1.211 from plus 0.043 to minus 0.046 times the solar mass, and radius (sub asterisk) equal to 1.360 from plus 0.064 o minus 0.053 times the solar radius. The planet is a relatively high-mass inflated gas giant with planetary mass equal to 2.75 from plus 0.016 to minus 0.15 times Jupiter's mass, planetary radius equal to 1.415 from plus 0.084 to minus 0.067 times Jupiter's radius, density planetary rho equal to 1.20 plus or minus 0.18 grams per cubic centimeter, surface gravity, log planetary gravity equal to 3.530 from plus 0.042 to minus 0.049, and equatorial temperature equal to 2453 from plus 55 to minus 47 degrees Kelvin. The best-fitting linear ephemeris is T(sub C) equal to 22457247.24791 plus or minus 0.00019 BJD (sub TDB) and P equal to 0.9689951 plus or minus 0.0000024 day. KELT-16b joins WASP-18b, -19b, -43b, -103b, and HATS-18b as the only giant transiting planets with periodicity P less than 1 day. Its ultra-short period and high irradiation make it a benchmark target for atmospheric studies by the Hubble Space Telescope, Spitzer, and eventually the James Webb Space Telescope. For example, as a hotter, higher-mass analog of WASP-43b, KELT-16b may feature an atmospheric temperature-pressure inversion and day-to-night temperature swing extreme enough for TiO to rain out at the terminator. KELT-16b could also join WASP-43b in extending tests of the observed mass-metallicity relation of the solar system gas giants to higher masses. KELT-16b currently orbits at a mere approximately 1.7 Roche radii from its host star, and could be tidally disrupted in as little as a few times 10 (sup 5) years (for a stellar tidal quality factor of Q (sup prime) (sub asterisk) equal to 10 (sup 5). Finally, the likely existence of a widely separated bound stellar companion in the KELT-16 system makes it possible that Kozai-Lidov (KL) oscillations played a role in driving KELT-16b inward to its current precarious orbit.

Oberst, Thomas E.↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

TOI-503: The First Known Brown-dwarf Am-star Binary from the TESS Mission

We report the discovery of an intermediate-mass transiting brown dwarf (BD), TOI-503b, from the TESS mission. TOI-503b is the first BD discovered by TESS, and it has circular orbit around a metallic-line A-type star with a period of P=3.6772±0.0001 days. The light curve from TESS indicates that TOI-503b transits its host star in a grazing manner, which limits the precision with which we measure the BD’s radius R(b) = 1.34(+0.26, -0.15)R(J). We obtained high resolution spectroscopic observations with the FIES, Ondrejov, PARAS, Tautenburg, and TRES spectrographs, and measured the mass of TOI-503b to be M(b)=53.7±1.2 M(J). The host star has a mass of M(*)=1.80±0.06M(ʘ), a radius of R(*)=1.70±0.05R(ʘ), an effective temperature of T(eff)=7650±160 K, and a relatively high metallicity of 0.61±0.07 dex. We used stellar isochrones to derive the age of the system to be ∼180 Myr, which places its age between that of RIK 72b (a ∼10 Myr old BD in the Upper Scorpius stellar association) and AD 3116b (a ∼600 Myr old BD in the Praesepe cluster). Given the difficulty in measuring the tidal interactions between BDs and their host stars, we cannot precisely say whether this BD formed in situ or has had its orbit circularized by its host star over the relatively short age of the system. Instead, we offer an examination of plausible values for the tidal quality factor for the star and BD. TOI-503b joins a growing number of known short-period, intermediate-mass BDs orbiting main sequence stars, and is the second such BD known to transit an A star, after HATS-70b. With the growth in the population in this regime, the driest region in the BD desert (35–55M(J) sin i) is reforesting.

Jan Subjak↗

Track Structure Components: Characterizing Energy Deposition from Direct and Peripheral Hits in Spherical Cells

Energy deposition by ionizing radiation in micrometric targets (microdosimetry), representative of cells, is very important to understand the effect of radiation and the cellular and biological response. Microdosimetry is used to estimate quality factors for risk assessment in radiation protection and quantify Relative Biological Effectiveness (RBE) for treatment planning of hadron radiation therapy. Radiation physics has shown that ionizing radiation deposit their energy in a complex manner, the track structure. Consequently, energy deposited in a target is a function of factors like the ion type, its energy and the irradiated volume.

Ianik Plante↗

Dispersion compensation in whispering gallery modes

We show that manipulation by a spatial profile of refractive index of a circularly symmetric dielectric cavity results in a novel way of fine tuning frequency separations as well as spatial localizations of high-Q whispering gallery modes excited in the cavity. The method enables dispersion compensation in the modes (spectrum equalization), diminishes the quality-factor limitation by surface roughness and contamination, and enables critical coupling to ultra-high-Q modes without maintaining an air-gap with evanescent couplers.

photonic↗

Low-threshold photonic crystal laser

We have fabricated photonic crystal nanocavity lasers, based on a new high-quality factor design that incorporates fractional edge dislocations.

photonic↗

Progress in the Development of Frequency-Domain Multiplexing for the X-ray Integral Field Unit on Board the Athena Mission

Frequency-domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality-factor LC filters and room-temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model with the single-pixel AC bias ( ΔE = 1.8 eV ) and nine-pixel multiplexing ( ΔE = 2.6 eV ) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by nonfundamental issues related to FDM readout in our laboratory setup.

H. Akamatsu↗

Low-Loss Thin-Film Al-On-Si Microwave Resonators for Astronomy Applications Designing and Characterizing the Next Generation of Microwave Detectors

We present measurements of prototype thin film Al microwave kinetic inductance detectors (MKIDs) intended for application in the sub-mm astronomy balloon experiment EXCLAIM. The device we show is dark, or non-optically coupled, and contains 16 coplanar waveguide (CPW) resonators etched into a 261 nm sputter deposited Al layer on a Si wafer. The resonators span the f0 = 3.5 - 4 GHz range, and include both lambda=2 and lambda=4 resonators. Each resonator is coupled to the feedline using one of three alternating coupling designs. We performed transmission line measurements of the device for a series of excitation powers ranging from -90 dBm to -30 dBm, and at a series of base temperatures ranging from 73 mK to 400 mK. We observed quality factors of up to Qi  107 at a base temperature of 73 mK. The lambda=2 and lambda=4 resonators performed similarly, achieving comparable Qi values. The results of these measurements are actively informing the fi nal design of the EXCLAIM instrument. EXCLAIM will incorporate six spectrometers, each containing an array of over 300 resonators in the 420-540 GHz range.

Carrie Volpert↗

On Parametric Generation of Deep UV Light in Monolithic Cavities With Cubic Nonlinearity

Coherent ultra violet (UV) light has broad applications in optical atomic clocks and quantum computers. Since availability of semiconductor tunable monochromatic lasers is limited at short wavelengths, optical nonlinear processes are frequently used to produce the desirable radiation wavelength. Optical crystals with quadratic nonlinearity are promising for this purpose because of their transparency and high optical damage threshold. In this paper we discuss a possibility of generation of coherent deep UV light utilizing high quality factor (-Q) monolithic optical microcavities made of crystalline optical materials characterized with cubic nonlinearities. We show that the generation is feasible in spite of the relatively small cubic nonlinearities, due to the ultra-broad-band high optical transparency of the crystals and associated high-Q achievable in the cavities created out of the materials. We found that the birefringence as well as the tensor nature of the nonlinear susceptibility of the crystalline optical materials can simplify the phase matching of the nonlinear processes.

Matsko, A.B.↗

A Cavity System for Seawater Dielectric Measurements at P-Band

This paper describes a new system for measuring the dielectric constant of seawater near 700 MHz. The purpose of this research is to obtain data at P-band for the dielectric constant of seawater that can be combined with previous L-band data for developing a model function valid from 500 MHz to 2000 MHz. A transmission-type cylindrical cavity has been constructed with the TM010 mode resonance occurring near 700 MHz. The seawater is introduced via a capillary quartz tube. The dimensions of the cavity have been determined by electromagnetic modelling. The model takes the cavity wall loss into account and can provide accurate estimation of resonance condition for both the empty cavity and cavity with seawater. The errors between the theory and measurement are about 0.07% for the resonant frequency and 0.4% for the quality factor, Q. The cavity design, experimental setup and measurement schedule will be presented in the paper.

Roger Lang↗

Impedance Matching a Quarter Wave Resonant Receiver to Improve Efficiency in Unipolar Capacitive Wireless Power Transfer

Impedance matching techniques to achieve high performance in conventional wireless power transfer (WPT) systems are well established. These WPT systems are modelled as a lumped circuit, where the voltages/currents are approximately uniform and mostly unaffected by parasitic elements. However, a group of WPT techniques exist that utilize parasitic elements to form a highly resonant power transfer condition at high quality factors, exploiting a distributed circuit operation that can be modeled as a mutually coupled transmission line. A calculated matching network typically becomes unmatched when connected to the transmission line, as it changes the electrical structure of the coupled transmission line. This is particularly true for WPT systems that use quarter wave (QWR) or half wave resonators (HWR) for the receiver. Here we present one technique of matching to a mutually coupled transmission line where a parallel path is formed that improves the power transfer efficiency without severely altering the transmission line characteristics.

Wireless↗

High-Rate Delay Tolerant Networking (HDTN) Software Requirements Analysis

This document serves as a detailed analysis of the main networking protocols implemented by HDTN. Sources of the protocol specifications include Internet Engineering Task Force (IETF) Request for Comments (RFC) and Consultative Committee for Space Data Systems (CCSDS) standards. The focus of this report is to derive software requirements suitable for NASA Procedural Requirements 7150.2D Class B compliance, including requirements traceability and software verification and validation, from the source specifications. This analysis will be incorporated into the finalized HDTN Software Requirements Specification (SRS) but does not encompass the full scope of the HDTN SRS. Requirements in this document are considered draft. The complete requirements will include bundle application requirements, interface requirements, computer resource requirements, software quality factors, and additional requirements as determined by the project. This document is publicly released to the greater community to receive feedback and foster collaboration opportunities.

Rachel Dudukovich↗

A Perspective on Multi-Source Energy Harvesting Technology Using Piezoelectric and Thermoelectric Materials

Energy harvesting using various locally available energy sources such as vibration energy, heat, sound, or magnetic field have become attractive topics for supplying power to modular electronic devices making them run independently in extreme environments. In this paper, we will be discussing the perspectives on thermoelectric (TE) and piezoelectric materials and devices, and then the concept of multi-source energy harvester using piezoelectric and thermoelectric devices and integration of them into a reliable and independent power source. TE materials having low thermal conductivity and high figure-of-merit ( zT ) are developed to convert even a small temperature gradient efficiently into electrical energy with the state-of-the-art conversion efficiency of ~15% and output power of ~56 W from single device. The piezoelectric device architecture is configured using high performance piezoelectric ceramics (Cu-Mn-PIN-PMN-PT). These ceramics exhibit high piezoelectric coefficient with high mechanical quality factor and low dielectric loss factor. Using these piezoelectric materials, power density as high a 2 mW/cm 2 is demonstrated in 1-1.5 g vibration environments. The piezoelectric device is attached on the surface of TE module to capture both the vibration and thermal energy sources to realize dual mode energy harvester. The multi-energy transfer strategy opens opportunities for a future generation of wireless and modular electronic devices. These devices would be useful in powering wearable electronic devices, micro sensor chargers, etc. in extreme environmental conditions using body heat/thermal sources and induced motion/vibrations.

Piezoelectric↗