Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

High speed two-dimensional imaging with an analog interface

A quantitative pulse count (event detection) algorithm with linearity to high count rates is accomplished by combining a high-speed, high frame rate camera with simple logic code run on a massively parallel processor such as a GPU. The parallel processor elements examine frames from the camera pixel by pixel to find and tag events or count pulses. The tagged events are combined to form a combined quantitative event image.

Waugh, Justin↗

Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative comparisons of radar image, scatterometer, and surface roughness data from Pisgah Crater, CA

The relationships between radar image brightness and backscatter coefficient, between the backscatter coefficient and surface roughness, and between surface roughness and geology, must be established in order to satisfy criteria for the quantitative use of radar images. Attention is presently given to the merits of calibrated radar images and scatterometers as sources of the backscatter coefficient, theories that yield the coefficient on the basis of known surface roughness (and vice versa), and the geologic interpretation of surface roughness and backscatter signatures. These considerations are discussed in the case of the Pisgah Crater and lava field in the Mojave Desert of California.

Farr, T. G.↗

Issues in Quantitative Analysis of Ultraviolet Imager (UV) Data: Airglow

The GGS Ultraviolet Imager (UVI) has proven to be especially valuable in correlative substorm, auroral morphology, and extended statistical studies of the auroral regions. Such studies are based on knowledge of the location, spatial, and temporal behavior of auroral emissions. More quantitative studies, based on absolute radiometric intensities from UVI images, require a more intimate knowledge of the instrument behavior and data processing requirements and are inherently more difficult than studies based on relative knowledge of the oval location. In this study, UVI airglow observations are analyzed and compared with model predictions to illustrate issues that arise in quantitative analysis of UVI images. These issues include instrument calibration, long term changes in sensitivity, and imager flat field response as well as proper background correction. Airglow emissions are chosen for this study because of their relatively straightforward modeling requirements and because of their implications for thermospheric compositional studies. The analysis issues discussed here, however, are identical to those faced in quantitative auroral studies.

Germany, G. A.↗

Aquarium Shot Image Analysis

Quantitative analysis of fast-frame imagery of explosive aquarium shots can extract an abundance of information regarding the evolution of both the shock and the product gases following the passage of a detonation front. Analysis of the product gases (or any other surface of interest that lies within the shock and is observed from outside of the shock) is complicated by the fact that the water shock refracts the light in all three dimensions. This makes it necessary to correct for this refraction in order to get an accurate perception of the location of the surface and subsequently the velocities derived from the shape of that surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-AB-202-06: Quantitative Evaluation of Deformable Image Registration in MRI-Guided Adaptive Radiation Therapy

Purpose: To assess the performance of the deformable image registration algorithm used for MRI-guided adaptive radiation therapy using image feature analysis. Methods: MR images were collected from five patients treated on the MRIdian (ViewRay, Inc., Oakwood Village, OH), a three head Cobalt-60 therapy machine with an 0.35 T MR system. The images were acquired immediately prior to treatment with a uniform 1.5 mm resolution. Treatment sites were as follows: head/neck, lung, breast, stomach, and bladder. Deformable image registration was performed using the ViewRay software between the first fraction MRI and the final fraction MRI, and the DICE similarity coefficient (DSC) for the skin contours was reported. The SIFT and Harris feature detection and matching algorithms identified point features in each image separately, then found matching features in the other image. The target registration error (TRE) was defined as the vector distance between matched features on the two image sets. Each deformation was evaluated based on comparison of average TRE and DSC. Results: Image feature analysis produced between 2000–9500 points for evaluation on the patient images. The average (± standard deviation) TRE for all patients was 3.3 mm (±3.1 mm), and the passing rate of TRE<3 mm was 60% on the images. The head/neck patient had the best average TRE (1.9 mm±2.3 mm) and the best passing rate (80%). The lung patient had the worst average TRE (4.8 mm±3.3 mm) and the worst passing rate (37.2%). DSC was not significantly correlated with either TRE (p=0.63) or passing rate (p=0.55). Conclusions: Feature matching provides a quantitative assessment of deformable image registration, with a large number of data points for analysis. The TRE of matched features can be used to evaluate the registration of many objects throughout the volume, whereas DSC mainly provides a measure of gross overlap. We have a research agreement with ViewRay Inc.

60 APPLIED LIFE SCIENCES↗

Quantitative effective atomic number imaging using simultaneous x-ray absorption and phase shift measurement

A scanning type x-ray imaging system which measures the absorption and differential phase shift in a material quantitatively and simultaneously has been developed. The absorption and differential phase are used to obtain the effective atomic number of organic material samples which closely reflects their chemical composition. An effective atomic number map of polymer fibers has been obtained. The experimentally obtained effective atomic numbers of these polymers agree well with the corresponding calculated values.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid Evaluation of Particle Properties using Inverse SEM Simulations

This report is the final deliverable of a 3 year project whose purpose was to investigate the possibility of using simulations of X-ray spectra generated inside a scanning electron microscope (SEM) as a means to perform quantitative analysis of the sample imaged in the SEM via an inverse analysis methodology. Using the nine point Technology Readiness Levels (TRL) typically used by the US Department of Defense (DOD) and the National Aeronautics and Space Administration (NASA), this concept is now at a TRL of 3. In other words, this work has proven the feasibility of this concept and is ready to be further investigated to address some of the issues highlighted by this initial proof of concept.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-207A-12: HLCC Based Quantitative Evaluation Method of Image Artifact in Dental CBCT

Purpose: Image artifacts are usually evaluated qualitatively via visual observation of the reconstructed images, which is susceptible to subjective factors due to the lack of an objective evaluation criterion. In this work, we propose a Helgason-Ludwig consistency condition (HLCC) based evaluation method to quantify the severity level of different image artifacts in dental CBCT. Methods: Our evaluation method consists of four step: 1) Acquire Cone beam CT(CBCT) projection; 2) Convert 3D CBCT projection to fan-beam projection by extracting its central plane projection; 3) Convert fan-beam projection to parallel-beam projection utilizing sinogram-based rebinning algorithm or detail-based rebinning algorithm; 4) Obtain HLCC profile by integrating parallel-beam projection per view and calculate wave percentage and variance of the HLCC profile, which can be used to describe the severity level of image artifacts. Results: Several sets of dental CBCT projections containing only one type of artifact (i.e. geometry, scatter, beam hardening, lag and noise artifact), were simulated using gDRR, a GPU tool developed for efficient, accurate, and realistic simulation of CBCT Projections. These simulated CBCT projections were used to test our proposed method. HLCC profile wave percentage and variance induced by geometry distortion are about 3∼21 times and 16∼393 times as large as that of the artifact-free projection, respectively. The increase factor of wave percentage and variance are 6 and133 times for beam hardening, 19 and 1184 times for scatter, and 4 and16 times for lag artifacts, respectively. In contrast, for noisy projection the wave percentage, variance and inconsistency level are almost the same with those of the noise-free one. Conclusion: We have proposed a quantitative evaluation method of image artifact based on HLCC theory. According to our simulation results, the severity of different artifact types is found to be in a following order: Scatter>Geometry>Beam hardening>Lag>Noise>Artifact-free in dental CBCT.

60 APPLIED LIFE SCIENCES↗

Correlation Analysis of TEM Images of Nanocrystal Molecules

Quantitative characterizataion of images of naocrystals and nanostructures is a challenging but important task. The development and optimization of methods for the construction of complex nanostructures rely on imaging techniques. Computer programs were developed to quantify TEM images of nanocrystal/DNA nanostructures, and results are presented for heterodimers annd trimers of gold nanocrystals. The programs presented here have also been used to analyze more complex trimers and tetramers linked by branched DNA, as well as for structures made from attaching gold nanocrystals to CdSe/ZnS core-shell quantum dots. This work has the additional goal of enabling others to quickly and easily adapt the methods for their own use.

36 MATERIALS SCIENCE↗

Development and Validation of Quantitative Model-Based Image Reconstruction for NDE of Reinforced Steel-Lined Concrete Structures: Kal-El FY 2020

This project studied the capabilities of Model-Based Image Reconstruction (MBIR) and Machine Learning (ML) algorithms in the imaging and estimation of rebar corrosion from ultrasound signals. The application was challenging due to the introduction of a steel liner between the sensor and the concrete containing the rebar. The study focused in a synthetic specimen with a 6.35 mm thick steel liner, and a 19.05 mm diameter rebar at a depth of 44.5 mm and with four levels of corrosion; 0%, 20%, 50%, and 100% corrosion level. The corrosion was applied uniformly around the rebar, generating a ring in the perimeter of the rebar with different acoustic density. In order to generate a realistic synthetic dataset, we added random texture to the concrete of the synthetic specimens. This texture will mimic the variations encountered in real concrete specimens.We adapted our MBIR algorithm for the application and enhanced the algorithm to integrate in the physical model known specimen features, such as the steel liner thickness. The new MBIR method was able to cancel out reverberation from the steel liner and properly image the rebar. In particular, corrosion for the 50% and 100% cases were easily visible and quantitative metrics showed a slight separation for the 0% and 20% levels. The quantitative results were in agreement with the qualitative assessment. We also developed a ML XGBoost model to estimate corrosion level from the ultrasound signals. By combining the ML method with MBIR, we can pinpoint in the ultrasound signals the section that corresponds to the echoes from the rebar. The extract signals are processed by the XGBoost model for prediction. From each system scan, we obtain 15 predictions. The median prediction value is used as the final prediction. The True Acceptance Rate for the method is over 99%.

36 MATERIALS SCIENCE↗

Evaluating Electroluminescence Imaging and Image Processing as a Quantitative Solar Cell Characterization Method

Mitigating dust accumulation on the surface of solar arrays is crucial for maintaining maximum power output. We propose investigating electroluminescence imaging paired with image processing as a means of evaluating various dust mitigation techniques. Image processing was able to clearly differentiate between pristine and dusted solar cells. Paired with traditional analysis techniques, this method proves to be a quick and powerful characterization tool.

Photovoltaic↗

A new hue capturing technique for the quantitative interpretation of liquid crystal images used in convective heat transfer studies

A new image processing based color capturing technique for the quantitative interpretation of liquid crystal images used in convective heat transfer studies is presented. This method is highly applicable to the surfaces exposed to convective heating in gas turbine engines. It is shown that, in the single-crystal mode, many of the colors appearing on the heat transfer surface correlate strongly with the local temperature. A very accurate quantitative approach using an experimentally determined linear hue vs temperature relation is found to be possible. The new hue-capturing process is discussed in terms of the strength of the light source illuminating the heat transfer surface, the effect of the orientation of the illuminating source with respect to the surface, crystal layer uniformity, and the repeatability of the process. The present method is more advantageous than the multiple filter method because of its ability to generate many isotherms simultaneously from a single-crystal image at a high resolution in a very time-efficient manner.

Camci, C.↗

SU-E-QI-16: Reproducibility of Computed Tomography Quantitative Structural Features Using the FDA Thoracic Phantom Image Database

Purpose: To assess the reproducibility of quantitative structural features using images from the computed tomography thoracic FDA phantom database under different scanning conditions. Methods: Development of quantitative image features to describe lesion shape and size, beyond conventional RECIST measures, is an evolving area of research in need of benchmarking standards. Gavrielides et al. (2010) scanned a FDA-developed thoracic phantom with nodules of various Hounsfield units (HU) values, shapes and sizes close to vascular structures using several scanners and varying scanning conditions/parameters; these images are in the public domain. We tested six structural features, namely, Convexity, Perimeter, Major Axis, Minor Axis, Extent Mean and Eccentricity, to characterize lung nodules. Convexity measures lesion irregularity referenced to a convex surface. Previously, we showed it to have prognostic value in lung adenocarcinoma. The above metrics and RECIST measures were evaluated on three spiculated (8mm/-300HU, 12mm/+30HU and 15mm/+30HU) and two non-spiculated (8mm/+100HU and 10mm/+100HU) nodules (from layout 2) imaged at three different mAs values: 25, 100 and 200 mAs; on a Phillips scanner (16-slice Mx8000-IDT; 3mm slice thickness). The nodules were segmented semi-automatically using a commercial software tool; the same HU range was used for all nodules. Results: Analysis showed convexity having the lowest maximum coefficient of variation (MCV): 1.1% and 0.6% for spiculated and non-spiculated nodules, respectively, much lower compared to RECIST Major and Minor axes whose MCV were 10.1% and 13.4% for spiculated, and 1.9% and 2.3% for non-spiculated nodules, respectively, across the various mAs. MCVs were consistently larger for speculated nodules. In general, the dependence of structural features on mAs (noise) was low. Conclusion: The FDA phantom CT database may be used for benchmarking of structural features for various scanners and scanning conditions; we used only a small fraction of available data. Our feature convexity outperformed other structural features including RECIST measures.

60 APPLIED LIFE SCIENCES↗

A Locally Adapting Technique for Edge Detection using Image Segmentation

Rapid growth in the field of quantitative digital image analysis is paving the way for scientific researchers to make precise measurements about objects in an image. To compute quantities from an image such as the density of compressed materials or the velocity of a shockwave, object boundaries must first be determined. Images containing regions that each have a spatial trend in intensity are of particular interest here. For edge detection, we present a supervised, statistical image segmentation method that incorporates spatial information to locate boundaries between regions with overlapping intensity histograms, specifically for images where the regions are known but precise boundary locations are unknown. The segmentation of a pixel is determined by comparing its intensity to distributions from nearby pixel intensities, and a gradient of the segmented image indicates edge locations. Because of the statistical nature of the algorithm, we use maximum likelihood estimation to quantify uncertainty about each boundary. We demonstrate the success of this algorithm at locating boundaries and providing uncertainty bands on a radiograph of a multicomponent cylinder and on an optical image of a laser-induced shockwave.

97 MATHEMATICS AND COMPUTING↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗