Center and limb solar spectrum in high spectral resolution 225.2 nm to 319.6 nm

The atlas has been designed to fulfill the need in solar and stellar astronomy, in aeronomy, and in space science for a convenient reference source that provides a detailed and accurate record of the measured solar ultraviolet spectrum in high spectral resolution for the wavelength range from 225.2 nm to 319.6 nm. The atlas also contains a preliminary synthetic solar spectrum with a legend for identifying and describing the features of the synthetic spectrum. Attention is given to aspects of instrumentation, the radiometric calibration, the wavelength scale, background noise random fluctuations and data filtering, intermittent noise, the observational conditions, the experimental uncertainty, the atlas format, references, tables, and plots.

Kohl, J. L.↗

Landsat-D data acquisition and processing

The Landsat-D system, in which S-band and X-band data links will provide real-time direct transmission of sensor data, is described. System performance objectives include input data quantity of 200 MSS scenes/day and 100 TM scenes/day by the Domestic Communication Satellite, and processing capability, in a pipeline mode, of 2.6 x 10 to the 11th input bits of sensor data per 16-hour day. Data processing techniques, including automated cloudcover assessment, control point library build system, radiometric calibration, and geometric correction are discussed.

Smith, P. L., Jr.↗

Fourier spectroscopy on planetary missions including Voyager

For more than a decade, spaceborne Fourier transform spectrometers have been employed in investigations concerning the earth and other objects in the solar system. The wide spectral range at moderately high spectral resolution, the precise wavenumber and radiometric calibrations, and the reliability achieved by these instruments, have permitted scientific investigations which would otherwise have been impossible. Weight limitations and the long flight durations prohibited the use of highly sensitive, cryogenically cooled detectors on these missions. A brief review is presented of the evolution of the instruments known as IRIS (InfraRed Interferometric Spectrometer). The concept of remote sensing by infrared emission spectroscopy is discussed, and examples of results obtained with IRIS are presented. Attention is given to the most recent results from Voyager with emphasis on those from Titan.

Hanel, R. A.↗

Study on radiometric consistency of LANDSAT-4 multispectral scanner

Two full frames of radiometrically corrected LANDSAT-4 MSS data were examined to determine a number of radiometric properties. It was found that LANDSAT-4 MSS produces data of good quality with dynamic ranges and target responses qualitatively similar to those of previous MSS sensors. Banding appears to be quite well corrected, with a residual rms error of about 0.3 digital counts being measured; the histogram equalization algorithm appears to be working as advertised. A low level coherent noise effect was found in all bands, appearing in uniform areas as a diagonal striping pattern. The principle component of this noise was found by Fourier analysis to be a highly consistent wavelength of 3.6 pixels along a scan line (28 KHz). The magnitude of this effect ranged from about 0.75 of one count in the worst band (Band 1) to only about 0.25 counts in the best band (Band 4). Preparations were made for establishing a relative radiometric calibration from MSS 4 data with respect to MSS 3.

Malila, W. A.↗

Radiometric considerations in remote sensing systems

All sensors systems designed to acquire quantitative data undergo radiometric calibration. The types and potential accuracies of calibration are discussed as well as the needs for calibration in the practical application of sensors. The recent and ongoing experience with the shuttle multispectral infrared radiometer is used as a reference.

Goetz, A. F. H.↗

Study of spectral/radiometric characteristics of the thematic mapper for land use applications

The previous characterization of scan-related low-frequency noise was confirmed and extended through analysis of reflective-band data from another nighttime acquisition. Amplitude and phase relationships of the level shifts were determined for each detector in each of free full frames. Analysis of scan-direction-related signal droop effects in nighttime data from the reflective bands was begun with encouraging initial observations. Also, an effort to characterize high-frequency noise in the reflective bands through Fourier analysis of nighttime data was initiated. Recommendations are made relative to the choice of radiometric calibration constants in the thematic mapper image processing system for the routine processing of TM data. Non-linear (piece-wise linear) calibration curves are recommended.

Malila, W. A.↗

CCRS proposal for evaluating LANDSAT-4 MSS and TM data

The measurement of registration errors in LANDSAT MSS data is discussed as well as the development of a revised algorithm for the radiometric calibration of TM data and the production of a geocoded TM image.

Strome, W. M.↗

Galilean satellite multispectral data base production

A photometrically and geometrically reduced data base is being produced for the Galilean Satellites using Voyager Imaging data. The basic data set used is essentially all the useful satellite images returned by Voyager. Each frame was radiometrically calibrated and many are projected into cartographic formats. Mosaics of low, medium and high resolution frames being made for each satellite consist of registered digital images with intensity values scaled through a traceable calibration procedure to normal albedo values. Many of the mosaics are being made in two versions. One version is an albedo version and the second is a maximum discrimination version in which large variations in brightness across the picture are suppressed.

Johnson, T. V.↗

Multispectral Scanner (MSS) Instrument Description

The MSS sensor image processing and resolution capabilities as well as a general system description are presented in chart form. Emphasis is placed on absolute radiometric calibration, video and wedge level timing sequence, focal plane dimensions, sampling sequence, and a description of the mirror coordinate systems.

Barker, J. L.↗

Diffusely Reflecting Paints Containing TFE

Highly reflective, diffused coatings developed by incorporating polytetrafluoroethylene (TFE) pigment with alcohol-soluble binders. Alcohol and binder mixed together in blender before adding TFE. TFE preferably outgassed in mechanical-pump vacuum for typical interval of 4 hours before adding to liquid. Like wetting agent, vacuum treatment helps to prevent clumping of TFE and eases dispersion throughout mixture. Mixture blended for 3 to 5 minutes before used. Coatings useful on reflectance-standard surfaces for calibrating radiometric instruments in both laboratory and field. Paints washable and usable as optical reference surfaces.

Shai, M. C.↗

Characterizing the scientific potential of satellite sensors

Analytical and programming support is to be provided to characterize the potential of the LANDSAT thematic mapper (TM) digital imagery for scientific investigations in the Earth sciences and in terrestrial physics. In addition, technical support to define lower atmospheric and terrestrial surface experiments for the space station and technical support to the Research Optical Sensor (ROS) study scientist for advanced studies in remote sensing are to be provided. Eleven radiometric calibration and correction programs are described. Coherent noise and bright target saturation correction are discussed along with image processing on the LAS/VAX and Hp-300/IDIMS. An image of San Francisco, California from TM band 2 is presented.

Source record↗

Evaluation of the Radiometric Integrity of LANDSAT 4 Thematic Mapper Band 6 Data

Probably the most generally accepted method for processing radiometric data from space is to correct the observed radiance or apparent temperature to a surface radiance or temperature value using atmospheric propagation models. As part of NASA's Heat Capacity Mapping Mission (HCMM) experiment the atmospheric propagation models were used in reverse in an attempt to evaluate the post launch radiometric response of the radiometer. Techniques successfully used to radiometrically calibrate the HCMM sensor were extended. The HCMM experiment is described and used as a base for the evaluation of the TM band 6 (infrared) sensor.

Schott, J. R.↗

Scientific Requirements for Ozone Measurements

A study was conducted to determine the necessary parameters for the correlation of data on Earth ozone. First, requirements for the needed measurement accuracy for the change in ozone (yearly percent decrease) over a ten year period were determined. Secondly, the capabilities of the solar backscatter ultraviolet spectrometer instrumentation (SBUV) were examined. These included satellite coverage, radiometric calibration accuracy, instrument degradation, and algorithm accuracy. Third, and finally, ground based total and vertical zone distribution measurements, which could be used to support satellite observations, were considered.

Source record↗

Progress in Planetary Radarclinometry

Efforts have continued to improve radarclinometry in spite of the fact that the theory and algorithms still predate the development of the radiometrically calibrated radar upon which they must depend in order to achieve metric precision. Such efforts help to insure the availability of the technique for data returned by the Venus Radar Mapper. Even now, compensation for layover and production of synthesized stereo enhance geologic interpretability of radar images. The theory of radarclinometry utilizes a knowledge of the relation between pixel DN value and terrain surface orientation to produce a topographic map. The process may be conceived in terms of a surface integral which develops away from a topographic profile as available ground truth. Alternatively, in consideration of the unavailability of ground truth in extraterrestrial applications, radarclinometry may develop as a line integral developing from a single point, providing reasonable assumptions about the mathematical nature of local curvature.

Wildey, R. L.↗

LANDSAT-4/5 image data quality analysis

A LANDSAT Thematic Mapper (TM) quality evaluation study was conducted to identify geometric and radiometric sensor errors in the post-launch environment. The study began with the launch of LANDSAT-4. Several error conditions were found, including band-to-band misregistration and detector-to detector radiometric calibration errors. Similar analysis was made for the LANDSAT-5 Thematic Mapper and compared with results for LANDSAT-4. Remaining band-to-band misregistration was found to be within tolerances and detector-to-detector calibration errors were not severe. More coherent noise signals were observed in TM-5 than in TM-4, although the amplitude was generally less. The scan direction differences observed in TM-4 were still evident in TM-5. The largest effect was in Band 4 where nearly a one digital count difference was observed. Resolution estimation was carried out using roads in TM-5 for the primary focal plane bands rather than field edges as in TM-4. Estimates using roads gave better resolution. Thermal IR band calibration studies were conducted and new nonlinear calibration procedures were defined for TM-5. The overall conclusion is that there are no first order errors in TM-5 and any remaining problems are second or third order.

Malaret, E.↗

Radiometric analysis of the longwave infrared channel of the Thematic Mapper on LANDSAT 4 and 5

The first objective was to evaluate the postlaunch radiometric calibration of the LANDSAT Thematic Mapper (TM) band 6 data. The second objective was to determine to what extent surface temperatures could be computed from the TM and 6 data using atmospheric propagation models. To accomplish this, ground truth data were compared to a single TM-4 band 6 data set. This comparison indicated satisfactory agreement over a narrow temperature range. The atmospheric propagation model (modified LOWTRAN 5A) was used to predict surface temperature values based on the radiance at the spacecraft. The aircraft data were calibrated using a multi-altitude profile calibration technique which had been extensively tested in previous studies. This aircraft calibration permitted measurement of surface temperatures based on the radiance reaching the aircraft. When these temperature values are evaluated, an error in the satellite's ability to predict surface temperatures can be estimated. This study indicated that by carefully accounting for various sensor calibration and atmospheric propagation effects, and expected error (1 standard deviation) in surface temperature would be 0.9 K. This assumes no error in surface emissivity and no sampling error due to target location. These results indicate that the satellite calibration is within nominal limits to within this study's ability to measure error.

Schott, John R.↗

On the spectral reflectance properties of materials exposed at the Viking landing sites

Reflectance data derived from Viking Lander multispectral data were used to characterize the types of soils and blocks exposed at the landing sites and to search for evidence of relatively unaltered igneous rocks. A comprehensive effort was mounted to examine multispectral data that combines testing of camera radiometric calibrations, explicitly removing the effects of atmospheric attenuation and skylight, and quantitatively comparing the corrected data to reflectance data from laboratory materials. Bi-directional reflectances for blue, green and red channels were determined for 31 block and soil exposures at Viking landing sites.

Guinness, E.↗