Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Glovebox for GeoLab Subsystem in HDU1-PEM

The GeoLab glovebox was designed to enable the preliminary examination, by astronauts, of geological samples collected from the surface of another planetary body. The collected information would then aid scientists in making decisions about sample curation and prioritization for return to Earth for study. This innovation was designed around a positive- pressure-enriched nitrogen environment glovebox to reduce sample handling contamination. The structure was custom-designed to fit in section H of NASA s Habitat Demonstration Unit 1 Pressurized Excursion Module (HDU1- PEM). In addition, the glovebox was designed to host analytical instruments in a way that prevents sample contamination.

Evans, Cynthia↗

The sensitive surface chemistry of Co-free, Ni-rich layered oxides: identifying experimental conditions that influence characterization results

Recent studies have suggested that Co-free, Ni-rich layered cathodes (e.g., doped LiNiO2) can provide promising battery performance for practical applications. However, these layered cathodes suffer from significant surface instability during various stages of the sample history, which generates inherent challenges for achieving stable battery performance and obtaining statistically representative characterization results. To reliably report the surface chemistry of these materials, delicate controls of stepwise sample preparation are required. In this study, we aim to reveal how the surface chemistry of LiNiO2 based materials changes with various environments, including human exhalation, sample storage, sample preparation, electrochemistry cycling, and surface doping. Our results demonstrate that the surface of these materials is highly reactive and prone to alter at various stages of sample handling and characterization. The sensitive surface could impact the interpretation of the surface chemical and structural information, including surface carbonate formation, transition metal reduction and dissolution, and surface reconstruction. Importantly, the heterogeneity of the surface degradation calls for a consolidation of nanoscale, high-resolution characterization, and ensemble-averaged methods in order to improve statistical representation. Furthermore, the doping chemistry can effectively mitigate the surface degradation and improve overall battery performance due to the enhanced surface oxygen retention. Our study highlights the necessity of strict measurements through complementary characterizations at multiple length scales to eliminate unintentional biased conclusions.

surface chemistry, Co-free Ni-rich cathodes, Istab↗

Cleanroom Contamination Identification Method Development

During fabrication, assembly, and testing of spacecraft and flight hardware it is vital to avoid contaminants that can cause degradation and could result in significant failure. Yet, there is no existing contamination monitoring method that provides the identity of airborne particles in a cleanroom facility. Knowing the particle identities, would allow scientists and engineers to determine the source of the contaminants and prevent setbacks before they occur or cause damage. Current cleanliness monitoring methods include airborne particle counters (APCs), fallout filters, and visual inspections. Particle counts from APCs are the primary metric used to define a cleanroom class and hence its level of cleanliness, but do not provide identification nor can they differentiate between large and small sizes of particles. In addition, using fallout filters is not a proactive, timely, or representative approach to cleanroom contamination monitoring because these samples are only retrieved after 30 days and are placed away from spacecraft processing to avoid interference with operations. In contrast, the forced air sampling method can collect a sample within an hour at any location required and provide results in less than a day. This system uses a cassette and filter sample medium to capture airborne particles which are then taken to a scanning electron microscope with energy dispersive spectroscopy (SEM/EDS) to identify and size the captured particles. Development of forced air sampling into an established laboratory capability will allow for fast sampling and routine identification of unknown contamination sources within the cleanroom. The test method development required market research for an air sampling cassette that increases sample collection efficiency and a filter with low enough background contamination to allow differentiation between a blank (control) and the collected sample. It was determined that a conductive black cassette and a polycarbonate filter were the best options. Conductive black cassettes, in comparison to the standard styrene, are manufactured using polypropylene filled with carbon. This makes the cassette conductive and minimizes the tendency of particles to stick to the wall of the cassette due to electrostatic force. In previous trials a mixed cellulose ester (MCE) filter was used to capture the contaminants, however the rougher surface of the filter contributed to entrapment of the particles within the filter structure and made it harder to identify the particles. In comparison, track etched polycarbonate filters have random cylindrical pores and a smooth surface which contributes to uniform sample distribution on the surface of the filter. Future work includes: testing the system using control samples to determine the efficiency and suitability of the medium, performing sample collection in various environments to establish ideal operating parameters and analyzing contaminant particles using SEM/EDS and assistant characterization techniques. Once fully developed, employing the forced air sampling method will help to prevent damage to spacecraft, avoid schedule delays, and allow for mission success.

Hernandez Melendez, Jailyn M.↗

Sample Identifiers and Metadata Reporting Format for Environmental Systems Science

The ESS-DIVE sample identifiers and metadata reporting format primarily follows the System for Earth Sample Registration (SESAR) Global Sample Number (IGSN) guide and template, with modifications to address Environmental Systems Science (ESS) sample needs and practicalities (IGSN-ESS). IGSNs are associated with standardized metadata to characterize a variety of different sample types (e.g. object type, material) and describe sample collection details (e.g. latitude, longitude, environmental context, date, collection method). Globally unique sample identifiers, particularly IGSNs, facilitate sample discovery, tracking, and reuse; they are especially useful when sample data is shared with collaborators, sent to different laboratories or user facilities for analyses, or distributed in different data files, datasets, and/or publications. To develop recommendations for multidisciplinary ecosystem and environmental sciences, we first conducted research on related sample standards and templates. We provide a comparison of existing sample reporting conventions, which includes mapping metadata elements across existing standards and Environment Ontology (ENVO) terms for sample object types and environmental materials. We worked with eight U.S. Department of Energy (DOE) funded projects, including those from Terrestrial Ecosystem Science and Subsurface Biogeochemical Research Scientific Focus Areas. Project scientists tested the process of registering samples for IGSNs and associated metadata in workflows for multidisciplinary ecosystem sciences. We provide modified IGSN metadata guidelines to account for needs of a variety of related biological and environmental samples. While generally following the IGSN core descriptive metadata schema, we provide recommendations for extending sample type terms, and connecting to related templates geared towards biodiversity (Darwin Core) and genomic (Minimum Information about any Sequence, MIxS) samples and specimens. ESS-DIVE recommends registering samples for IGSNs through SESAR, and we include instructions for registration using the IGSN-ESS guidelines. Our resulting sample reporting guidelines, template (IGSN-ESS), and identifier approach can be used by any researcher with sample data for ecosystem sciences.

54 ENVIRONMENTAL SCIENCES↗

Ultrasonic/Sonic Driller/Corer (USDC) as a Subsurface Sampler and Sensors Platform for Planetary Exploration Applications

The search for existing or past life in the Universe is one of the most important objectives of NASA's mission. For this purpose, effective instruments that can sample and conduct in-situ astrobiology analysis are being developed. In support of this objective, a series of novel mechanisms that are driven by an Ultrasonic/Sonic actuator have been developed to probe and sample rocks, ice and soil. This mechanism is driven by an ultrasonic piezoelectric actuator that impacts a bit at sonic frequencies through the use of an intermediate free-mass. Ultrasonic/Sonic Driller/Corer (USDC) devices were made that can produce both core and powdered cuttings, operate as a sounder to emit elastic waves and serve as a platform for sensors. For planetary exploration, this mechanism has the important advantage of requiring low axial force, virtually no torque, and can be duty cycled for operation at low average power. The advantage of requiring low axial load allows overcoming a major limitation of planetary sampling in low gravity environments or when operating from lightweight robots and rovers. The ability to operate at duty cycling with low average power produces a minimum temperature rise allowing for control of the sample integrity and preventing damage to potential biological markers in the acquired sample. The development of the USDC is being pursued on various fronts ranging from analytical modeling to mechanisms improvements while considering a wide range of potential applications. While developing the analytical capability to predict and optimize its performance, efforts are made to enhance its capability to drill at higher power and high speed. Taking advantage of the fact that the bit does not require rotation, sensors (e.g., thermocouple and fiberoptics) were integrated into the bit to examine the borehole during drilling. The sounding effect of the drill was used to emit elastic waves in order to evaluate the surface characteristics of rocks. Since the USDC is driven by piezoelectric actuation mechanism it can designed to operate at extreme temperature environments from very cold as on Titan and Europa to very hot as on Venus. In this paper, a review of the latest development and applications of the USDC will be given.

sampling↗

An interactive modular design for computerized photometry in spectrochemical analysis

A general functional description of totally automatic photometry of emission spectra is not available for an operating environment in which the sample compositions and analysis procedures are low-volume and non-routine. The advantages of using an interactive approach to computer control in such an operating environment are demonstrated. This approach includes modular subroutines selected at multiple-option, menu-style decision points. This style of programming is used to trace elemental determinations, including the automated reading of spectrographic plates produced by a 3.4 m Ebert mount spectrograph using a dc-arc in an argon atmosphere. The simplified control logic and modular subroutine approach facilitates innovative research and program development, yet is easily adapted to routine tasks. Operator confidence and control are increased by the built-in options including degree of automation, amount of intermediate data printed out, amount of user prompting, and multidirectional decision points.

Bair, V. L.↗

Nonparametric Multiparticle Set Methods for Interpreting Environmental Samples

Collection and analysis of environmental samples is commonly used by a range of stakeholders in nuclear safeguards and security contexts. While the ubiquity of samples and their transport in the environment allow regular collection, developing and demonstrating methods for analyzing these samples is difficult. In this work, an environmental sample consists of a set of one or more individual particles. Recent advances in reactor simulation have allowed us to generate data that are more representative of real-world environmental samples, enabling statistically defensible method development and testing. The most notable of these advances is a drastic increase in the number of material depletion regions, which allows our simulations to capture the variation in isotopic composition seen at length scales consistent with environmental samples. Traditional approaches for handling multiparticle samples treat each particle in the sample individually, estimating the quantity of interest (e.g., core-average burnup) resulting from measurement and analysis of signatures (e.g., nuclide assays) from each individual particle. Individual estimates are then averaged to generate a single estimate of the quantity of interest over the entire sample. In this presentation, we introduce two novel approaches for interpreting environmental samples that comprise of multiple particles: (1) the Quantile-Quantile Comparator, which uses a multivariate generalization of quantile-quantile plots for comparing unknown statistical distributions, and (2) the Set Transformer, an attention-based neural network module designed to model interactions among elements (particles) in the input set (sample). Statistically representative sampling cannot be guaranteed as samples are passively collected and are beholden to what particles are available in the environment. These new analysis methods for set-input problems are expected to be more robust than traditional approaches to issues of sampling bias where particles are not uniformly distributed throughout regions of interest, as well as generally outperform traditional approaches by jointly considering all elements in the set. We will present results comparing the performance of traditional single particle approaches and the novel Quantile-Quantile Comparator and Set Transformer for interpretation of simulated environmental samples.

Phathanapirom, Birdy↗

Corrosion of metal samples rapidly measured

Corrosion of a large number of metal samples that have been exposed to controlled environment is accurately and rapidly measured. Wire samples of the metal are embedded in clear plastic and sectioned for microexamination. Unexposed wire can be included in the matrix as a reference.

Maskell, C. E.↗

Do galactic potential wells depend on their environment?

Using galaxies in complete samples as tracers of the galaxy density field and about 1000 galaxies with measured circular velocities as targets, we examine the cross-correlation functions between the targets and tracers as a function of galaxy circular velocities. The correlation strength does not vary with the circular velocities except for elliptical galaxies with the highest velocity dispersions, where the effect may well be due to morphological segregations in clusters of galaxies. This is contrasted with the strong dependence of the correlation functions of dark halos on their circular velocities in some models of galaxy formation.

Mo, H. J.↗

Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions

In the robotic search for life on Mars, different proposed missions will analyze the chemical and biological signatures of life using different platforms. The analysis of samples via analytical instrumentation on the surface of Mars has thus far only been attempted by the two Viking missions. Robotic arms scooped relogith material into a pyrolysis oven attached to a GC/MS. No trace of organic material was found on any of the two different samples at either of the two different landing sites. This null result puts an upper limit on the amount of organics that might be present in Martian soil/rocks, although the level of detection for each individual molecular species is still debated. Determining the absolute limit of detection for each analytical instrument is essential so that null results can be understood. This includes investigating the trade off of using pyrolysis versus liquid solvent extraction to release organic materials (in terms of extraction efficiencies and the complexity of the sample extraction process.) Extraction of organics from field samples can be accomplished by a variety of methods such utilizing various solvents including HCl, pure water, supercritical fluid and Soxhelt extraction. Utilizing 6N HCl is one of the most commonly used method and frequently utilized for extraction of organics from meteorites but it is probably infeasible for robotic exploration due to difficulty of storage and transport. Extraction utilizing H2O is promising, but it could be less efficient than 6N HCl. Both supercritical fluid and Soxhelt extraction methods require bulky hardware and require complex steps, inappropriate for inclusion on rover spacecraft. This investigation reports the efficiencies of pyrolysis and solvent extraction methods for amino acids for different terrestrial samples. The samples studied here, initially created in aqueous environments, are sedimentary in nature. These particular samples were chosen because they possibly represent one of the best terrestrial analogs of Mars and they represent one of the absolute best case scenarios for finding organic molecules on the Martian surface.

Beegle, L. W.↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Promoted Combustion of Metals in a High-Pressure, Flowing Oxygen Environment

Traditional promoted combustion testing has used 0.125 inch diameter samples that are ignited in a pressurized, oxygen-enriched environment. Many years of testing this sample size have yielded useful data regarding threshold pressure, or the minimum oxygen pressure required to support self-sustained combustion. However, when a material is tested in a flowing system, the threshold pressure changes. White Sands Test Facility has developed a test system to burn samples in flowing gaseous oxygen. Current sample configurations are 0.5 inch diameter rods and 1.25 inch diameter pipes with pressures ranging up to 2000 psi and gas velocities reaching 200 ft/s. This paper describes the test apparatus, modifications made as the result of a fire, and a description of the tests currently being performed.

Maes, M. J.↗

The Marshall Space Flight Center Drop Tube Facility

The structural and instrumentation hardware and the improved experimental capabilities of a 105-m Drop Tube Facility are described. The structure is designed to provide a high-vacuum facility in a vertical orientation. The low-gravity environment obtained during free-fall and the containerless materials processing capabilities are discussed. Two furnaces, an electron-beam and an electromagnetic levitator, are used to melt metallic samples in a process environment ranging from 10 to the -6th torr to 1 atm. Specifics of the vacuum control and gas delivery systems are provided. The experimental instrumentation and data acquisition systems used to perform predrop and in-flight measurements of the melting and solidification process are discussed. Typical experimental results are presented as an indicator of the performance of the Drop Tube Facility.

Rathz, Thomas J.↗

High-temperature Tribological Behavior of Structural Materials after Conditioning in Impure-Helium Environments for High_temperature Gas-Cooled Reactor Applications

Incoloy 800HT and Inconel 617 have been selected as candidate structural alloys for the hightemperature gas-cooled reactor (HTGR) concept. Helium, the primary coolant, contains impurities (e.g., H2O and CH4) that can induce corrosion reactions at high temperatures, which in turn can affect the tribological behavior of components in sliding contact such as valves and control-rod drive systems. This paper presents results from the study of the tribological behavior of both alloys before and after conditioning them in either an impure-helium oxidizing environment or in an air environment. Both alloys were conditioned for 22 days at elevated temperatures in a once-through helium loop with 4 ppmv H2O and tested subsequently at elevated temperatures with a pin-on-disk tribometer in an air environment 650 degrees C and 750 degrees C for 800HT; 850 degrees C and 900 degrees C for 617 - with various applied loads - 1 N, 2 N and 5 N. SEM-EDS analysis revealed that conditioning the samples in an oxidizing environment leads to the formation of a mixed Fe/Cr-oxide on alloy 800HT and a Cr-oxide on alloy 617, both increasing the wear resistance compared to that of as-received samples. Alloy 617 exhibited lower steady-state friction coefficients compared to those of alloy 800HT. There was a significant decrease in the scatter of the steadystate friction coefficient of the conditioned samples compared to that of the unconditioned samples. The steady-state friction coefficient for alloy 800HT and 617 were found to be 0.53 +/- 0.07 and 0.25 +/- 0.04, respectively. The wear resistance of alloy 800HT is approximately one order of magnitude lower than that of alloy 617 in all cases that exhibited measurable wear. After sample conditioning, the wear volumes measured at low loads were undistinguishable from the unworn background, a result attributed to the formation of a compacted glaze layer under high temperatures and high contact stresses.

Alloys 800 and 617↗

Microbiological Contamination of Spacecraft

The International Space Station (ISS) Phase1 Program resulted in seven US astronauts residing aboard the Russian Space Station Mir between March 1995 and May 1998. Collaboration between U.S. and Russian scientists consisted of collection and analyses of samples from the crewmembers and the Mir and Shuttle environments before, during, and after missions that lasted from 75 to 209 days in duration. The effects of long-duration space flight on the microbial characteristics of closed life support systems and the interactions of microbes with the spacecraft environment and crewmembers were investigated. Air samples were collected using a Russian or U.S.-supplied sampler (SAS, RCS, or Burkard,) while surface samples were collected using contact slides (Hycon) or swabs. Mir recycled condensate and stored potable water sources were analyzed using the U.S.-supplied Water Experiment Kit. In-flight analysis consisted of enumeration of levels of bacteria and fungi. Amounts of microorganisms seen in the air and on surfaces were mostly within acceptability lin1its; observed temporal fluctuations in levels of microbes probably reflect changes in environmental conditions (e.g., humidity). All Mir galley hot water samples were within the standards set for Mir and the ISS. Microbial isolates were returned to Earth for identification of bacterial and fungal isolates. Crew samples (nose, throat, skin, urine, and feces) were analyzed using methods approved for the medical evaluations of Shuttle flight crews. No significant changes in crew microbiota were found during space flight or upon return relative to preflight results. Dissemination of microbes between the crew and environment was demonstrated by D A fingerprinting. Some biodegradation of spacecraft materials was observed. Accumulation of condensate allowed for the recovery of a wide range of bacteria and fungi as well as some protozoa and dust mites.

Pierson, D. L.↗

Advanced Curation of Current and Future Extraterrestrial Samples

Curation of extraterrestrial samples is the critical interface between sample return missions and the international research community. Curation includes documentation, preservation, preparation, and distribution of samples. The current collections of extraterrestrial samples include: Lunar rocks / soils collected by the Apollo astronauts Meteorites, including samples of asteroids, the Moon, and Mars "Cosmic dust" (asteroid and comet particles) collected by high-altitude aircraft Solar wind atoms collected by the Genesis spacecraft Comet particles collected by the Stardust spacecraft Interstellar dust collected by the Stardust spacecraft Asteroid particles collected by the Hayabusa spacecraft These samples were formed in environments strikingly different from that on Earth. Terrestrial contamination can destroy much of the scientific significance of many extraterrestrial materials. In order to preserve the research value of these precious samples, contamination must be minimized, understood, and documented. In addition the samples must be preserved - as far as possible - from physical and chemical alteration. In 2011 NASA selected the OSIRIS-REx mission, designed to return samples from the primitive asteroid 1999 RQ36 (Bennu). JAXA will sample C-class asteroid 1999 JU3 with the Hayabusa-2 mission. ESA is considering the near-Earth asteroid sample return mission Marco Polo-R. The Decadal Survey listed the first lander in a Mars sample return campaign as its highest priority flagship-class mission, with sample return from the South Pole-Aitken basin and the surface of a comet among additional top priorities. The latest NASA budget proposal includes a mission to capture a 5-10 m asteroid and return it to the vicinity of the Moon as a target for future sampling. Samples, tools, containers, and contamination witness materials from any of these missions carry unique requirements for acquisition and curation. Some of these requirements represent significant advances over methods currently used. New analytical and screening techniques will increase the value of current sample collections. Improved web-based tools will make information on all samples more accessible to researchers and the public. Advanced curation of current and future extraterrestrial samples includes: Contamination Control - inorganic / organic Temperature of preservation - subfreezing / cryogenic Non-destructive preliminary examination - X-ray tomography / XRF mapping / Raman mapping Microscopic samples - handling / sectioning / transport Special samples - unopened lunar cores Informatics - online catalogs / community-based characterization.

Allen, Carlton C.↗

High-Resolution Imaged-Based 3D Reconstruction Combined with X-Ray CT Data Enables Comprehensive Non-Destructive Documentation and Targeted Research of Astromaterials

Providing web-based data of complex and sensitive astromaterials (including meteorites and lunar samples) in novel formats enhances existing preliminary examination data on these samples and supports targeted sample requests and analyses. We have developed and tested a rigorous protocol for collecting highly detailed imagery of meteorites and complex lunar samples in non-contaminating environments. These data are reduced to create interactive 3D models of the samples. We intend to provide these data as they are acquired on NASA's Astromaterials Acquisition and Curation website at http://curator.jsc.nasa.gov/.

Blumenfeld, E. H.↗

Genesis Contingency Planning and Mishap Recovery: The Sample Curation View

Planning for sample preservation and curation was part of mission design from the beginning. One of the scientific objectives for Genesis included collecting samples of three regimes of the solar wind in addition to collecting bulk solar wind during the mission. Collectors were fabricated in different thicknesses for each regime of the solar wind and attached to separate frames exposed to the solar wind during specific periods of solar activity associated with each regime. The original plan to determine the solar regime sampled for specific collectors was to identify to which frame the collector was attached. However, the collectors were dislodged during the hard landing making identification by frame attachment impossible. Because regimes were also identified by thickness of the collector, the regime sampled is identified by measuring fragment thickness. A variety of collector materials and thin films applied to substrates were selected and qualified for flight. This diversity provided elemental measurement in more than one material, mitigating effects of diffusion rates and/or radiation damage. It also mitigated against different material and substrate strengths resulting in differing effects of the hard landing. For example, silicon crystal substrates broke into smaller fragments than sapphire-based substrates and diamond surfaces were more resilient to flying debris damage than gold. The primary responsibility of the curation team for recovery was process documentation. Contingency planning for the recovery phase expanded this responsibility to include not only equipment to document, but also gather, contain and identify samples from the landing area and the recovered spacecraft. The team developed contingency plans for various scenarios as part of mission planning that included topographic maps to aid in site recovery and identification of different modes of transport and purge capability depending on damage. A clean tent, set-up at Utah Test & Training Range to control the environment for processing the sample return capsule and cleanly installing a nitrogen purge to the canister, was used to control the environment for extracting collector fragments from the damaged canister and to document and package over 10,000 collector fragments.

Stansbery, E. K.↗