Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗

Improving Subsurface Stress Characterization for Carbon Dioxide Storage Projects

Researchers at New Mexico Tech, Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), and other collaborators are developing a methodology to improve characterization of stress in the subsurface by means of a model-based inversion of reservoir engineering data, time lapse seismic measurements, and microseismicity. Historically, various geophysical techniques have been used in efforts to understand the state of stress in the subsurface through direct and indirect imaging of stress sensitive features (faults and fractures) and observations of transient stress related observations (time variant elastic moduli and microseismicity). Standard direct and indirect techniques for seismic fault and fracture imaging suffer from detectability limits due to reliance on high data quality and multiplicity. Variations in effective elastic properties from inversion of high quality seismic (Vertical Seismic Profile (VSP)) data may be used to infer stress near the wellbore through integration with independent experimental characterization of the stress-velocity relationship. Given a sufficiently robust observation network, microseismic emissions may be inverted to characterize focal mechanisms which, together with supporting assumptions and constraints, inform estimates of in-situ stress. While each of these techniques contributes in part to the characterization of stress within limited spatial and temporal domains, no one method provides an unambiguous stress measurement or a predictive capability over a site scale spatial extent. Challenges associated with solution non-uniqueness, measurement ambiguity, and irregular sampling may be greatly minimized through combination of one or more of independent measurements within a common framework in which realistic geological, hydrodynamic, geomechanical, and seismological constituent process models may act as constraints.

02 PETROLEUM↗

Radiation Damage Studies of Materials and Electronic Devices Using Hadrons

We have irradiated NdFeB permanent magnet samples from different manufacturers and with differing values of coercivity and remanence using stepped doses of 1 MeV equivalent neutrons up to a fluence of 0:64 1015n=cm2 to evaluate effects on magnetization and B field distributions. The samples with high coercivity, irradiated in open circuit configurations, showed no or minimal effects when compared with unirradiated samples, whereas the lower coercivity magnets suffered significant losses of magnetization and changes in the shapes of their field patterns. One such magnet underwent a fractional magnetization loss of 13.1% after a fluence of 0:59 1015 n=cm2. This demagnetization was not uniform. With increasing fluence, B field scans along the centerlines of the pole faces revealed that the normal component of B decreased more near the midpoint of the scan than near the ends. In addition, a fit to the curve of overall magnetization loss with fluence showed a significant deviation from linearity. The results are discussed in light of other measurements and theory. The high coercivity materials appear suitable for use in accelerator applications subject to irradiation by fast neutrons such as dipoles where the internal demagnetizing field is comparable to or less than that of the open circuit samples tested in this study.

Pellett, David↗

80% Hydrogen Peroxide Mixtures with Various Fuels

Impact sensitivity testing was performed using a modified Bureau of Mines (MBOM) impactor manufactured by Safety Management Services, Inc. Type-12 tooling was utilized on this machine with a 2.5kg impactor and matching intermediate mass. This particular machine is capable of a maximum drop height of 115cm with 0.1cm increments, though 1cm increments are typically used. Sample material was placed (35 ± 2mg) onto 1 inch squares of Norton brand 180A Garnet sandpaper. Due to the reactive nature of the peroxide in these mixtures, contact between the sample and sandpaper was minimized (<10s) prior to impact. Positive results were detected visually or audibly by the operator as smoke, flash, report, tearing of the sandpaper, etc. The test was conducted using the Bruceton technique to calculate the height at which there is a 50% chance of initiation (H 50 ).

36 MATERIALS SCIENCE↗

Leveraging design of experiments to build chemometric models for the quantification of uranium (VI) and HNO3 by Raman spectroscopy

Partial least squares regression (PLSR) and support vector regression (SVR) models were optimized for the quantification of U(VI) (10–320 g L −1 ) and HNO 3 (0.6–6 M) by Raman spectroscopy with optimized calibration sets chosen by optimal design of experiments. The designed approach effectively minimized the number of samples in the calibration set for PLSR and SVR by selecting sample concentrations with a quadratic process model, despite complex confounding and covarying spectral features in the spectra. The top PLS2 model resulted in percent root mean square errors of prediction for U(VI), HNO 3 , and NO 3 − of 3.7%, 3.6%, and 2.9%, respectively. PLS1 models performed similarly despite modeling an analyte with a majority linear response (i.e., uranyl symmetric stretch) and another with more covarying vibrational modes (i.e., HNO 3 ). Partial least squares (PLS) model loadings and regression coefficients were evaluated to better understand the relationship between weaker Raman bands and covarying spectral features. Support vector machine models outperformed PLS1 models, resulting in percent root mean square error of prediction values for U(VI) and HNO 3 of 1.5% and 3.1%, respectively. The optimal nonlinear SVR model was trained using a similar number of samples (11) compared with the PLSR model, even though PLS is a linear modeling approach. The generic D-optimal design presented in this work provides a robust statistical framework for selecting training set samples in disparate two-factor systems. This approach reinforces Raman spectroscopy for the quantification of species relevant to the nuclear fuel cycle and provides a robust chemometric modeling approach to bolster online monitoring in challenging process environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Research Trends and Applications of PMUs

This work is a survey of current trends in applications of PMUs. PMUs have the potential to solve major problems in the areas of power system estimation, protection, and stability. A variety of methods are being used for these purposes, including statistical techniques, mathematical transformations, probability, and AI. The results produced by the techniques reviewed in this work are promising, but there is work to be performed in the context of implementation and standardization. As the smart grid initiative continues to advance, the number of intelligent devices monitoring the power grid continues to increase. PMUs are at the center of this initiative, and as a result, each year more PMUs are deployed across the grid. Since their introduction, myriad solutions based on PMU-technology have been suggested. The high sampling rates and synchronized measurements provided by PMUs are expected to drive significant advancements across multiple fields, such as the protection, estimation, and control of the power grid. This work offers a review of contemporary research trends and applications of PMU technology. Most solutions presented in this work were published in the last five years, and techniques showing potential for significant impact are highlighted in greater detail. Being a relatively new technology, there are several issues that must be addressed before PMU-based solutions can be successfully implemented. This survey found that key areas where improvements are needed include the establishment of PMU-observability, data processing algorithms, the handling of heterogeneous sampling rates, and the minimization of the investment in infrastructure for PMU communication. Solutions based on Bayesian estimation, as well as those having a distributed architectures, show great promise. The material presented in this document is tailored to both new researchers entering this field and experienced researchers wishing to become acquainted with emerging trends.

42 ENGINEERING↗

Cellulose Isolation Methodology for NMR Analysis of Cellulose Ultrastructure

In order to obtain accurate information about the ultrastructure of cellulose from native biomass by 13C cross polarization magic angle spinning (CP/MAS) NMR spectroscopy the cellulose component must be isolated due to overlapping resonances from both lignin and hemicellulose. Typically, cellulose isolation has been achieved via holocellulose pulping to remove lignin followed by an acid hydrolysis procedure to remove the hemicellulose components. Using 13C CP/MAS NMR and non-linear line-fitting of the cellulose C4 region, it was observed that the standard acid hydrolysis procedure caused an apparent increase in crystallinity of ~10% or less on the cellulose isolated from Populus holocellulose. We have examined the effect of the cellulose isolation method, particularly the acid treatment time for hemicellulose removal, on cellulose ultrastructural characteristics by studying these effects on cotton, microcrystalline cellulose (MCC) and holocellulose pulped Populus. 13C CP/MAS NMR of MCC indicated that holocellulose pulping and acid hydrolysis has little effect on the crystalline ultrastructural components of cellulose. Although any chemical method to isolate cellulose from native biomass will invariably alter substrate characteristics, especially those related to regions accessible to solvents, we found those changes to be minimal and consistent in samples of typical crystallinity and lignin/hemicellulose content. Based on the rate of the hemicellulose removal, as determined by HPLC-carbohydrate analysis and magnitude of cellulose ultrastructural alteration, the most suitable cellulose isolation methodology utilizes a treatment of 2.5 M HCl at 100 °C for a standard residence time between 1.5 and 4 h. However, for the most accurate crystallinity results this residence time should be determined empirically for a particular sample.

13C CP/MAS↗

Variability in NGC 3201 Giant Stars and Its Impact on Their Spectroscopic [Fe/H] Determination

We present the analysis of 34 light curves in V and I of 17 giant stars in the globular cluster NGC 3201 to check if such stars are variable and if their variability has some kind of impact on the iron abundance as obtained from spectroscopic measurements. First, we computed the generalized Lomb–Scargle and phase dispersion minimization periodograms of the sample to check if the stars were variables. In this way, seven stars of the sample were found to be nonvariable, two stars are considered as possible variables, and eight stars were found to be variable, with periods ranging from 0.0881 ± 0.0001 to 0.5418 ± 0.0027 days. According to the literature, the variables have distinct values of [Fe I/H]: the three most metal-rich stars are in the red giant branch (RGB) stage, one has [Fe I/H] = −1.37 dex, while the other two have [Fe I/H] = −1.31 dex. The two most metal-poor variables have [Fe I/H] = −1.61 dex and [Fe I/H] = −1.62 dex, and are AGB stars; the remaining variables have [Fe I/H] = −1.44, −1.48, and −1.50 dex, the first two being RGB stars while the last is an AGB star. On the other hand, stars that appear to be nonvariable have −1.56 ≤ [Fe I/H] ≤ −1.40. We conclude that variability somehow affects the spectroscopic determination of the iron content of giant stars in NGC 3201, increasing the iron spread of the cluster. If variability is not taken into account, this spread could be incorrectly interpreted as due to an intrinsic iron spread affecting the stars of the cluster.

36 MATERIALS SCIENCE↗

Method for copper staining of germanium crystals

Proper conditions for copper staining of germanium crystals include a low solution temperature of 3 degrees C, illumination of the sample by infrared light, and careful positioning of the light source relative to the sample so as to minimize absorption of the infrared light.

Rivet, E. J.↗

On the constancy of the lunar cratering flux over the past 3.3 billion yr

Utilizing a method that minimizes random fluctuations in sampling crater populations, it can be shown that the ejecta deposit of Tycho, the floor of Copernicus, and the region surrounding the Apollo 12 landing site have incremental crater size-frequency distributions that can be expressed as log-log linear functions over the diameter range from 0.1 to 1 km. Slopes are indistinguishable for the three populations, probably indicating that the surfaces are dominated by primary craters. Treating the crater populations of Tycho, the floor of Copernicus, and Apollo 12 as primary crater populations contaminated, but not overwhelmed, with secondaries, allows an attempt at calibration of the post-heavy bombardment cratering flux. Using the age of Tycho as 109 m.y., Copernicus as 800 m.y., and Apollo 12 as 3.26 billion yr, there is no basis for assuming that the flux has changed over the past 3.3 billion yr. This result can be used for dating intermediate aged surfaces by crater density.

Guinness, E. A.↗

Jet Engine hot parts IR Analysis Procedure (J-EIRP)

A thermal radiation analysis method called Jet Engine IR Analysis Procedure (J-EIRP) was developed to evaluate jet engine cavity hot parts source radiation. The objectives behind J-EIRP were to achieve the greatest accuracy in model representation and solution, while minimizing computer resources and computational time. The computer programs that comprise J-EIRP were selected on the basis of their performance, accuracy, and flexibility to solve both simple and complex problems. These programs were intended for use on a personal computer, but include the ability to solve large problems on a mainframe or supercomputer. J-EIRP also provides the user with a tool for developing thermal design experience and engineering judgment through analysis experimentation, while using minimal computer resources. A sample jet engine cavity analysis demonstrates the procedure and capabilities within J-EIRP, and is compared to a simplified method for approximating cavity radiation. The goal is to introduce the terminology and solution process used in J-EIRP and to provide insight into the radiation heat transfer principles used in this procedure.

Baumeister, Joseph F.↗

Electronic Photography at the NASA Langley Research Center

An electronic photography facility has been established in the Imaging & Photographic Technology Section, Visual Imaging Branch, at the NASA Langley Research Center (LaRC). The purpose of this facility is to provide the LaRC community with access to digital imaging technology. In particular, capabilities have been established for image scanning, direct image capture, optimized image processing for storage, image enhancement, and optimized device dependent image processing for output. Unique approaches include: evaluation and extraction of the entire film information content through scanning; standardization of image file tone reproduction characteristics for optimal bit utilization and viewing; education of digital imaging personnel on the effects of sampling and quantization to minimize image processing related information loss; investigation of the use of small kernel optimal filters for image restoration; characterization of a large array of output devices and development of image processing protocols for standardized output. Currently, the laboratory has a large collection of digital image files which contain essentially all the information present on the original films. These files are stored at 8-bits per color, but the initial image processing was done at higher bit depths and/or resolutions so that the full 8-bits are used in the stored files. The tone reproduction of these files has also been optimized so the available levels are distributed according to visual perceptibility. Look up tables are available which modify these files for standardized output on various devices, although color reproduction has been allowed to float to some extent to allow for full utilization of output device gamut.

Holm, Jack↗

Curation of Frozen Samples

NASA's Johnson Space Center (JSC) and the Astromaterials Curator are charged by NPD 7100.10D with the curation of all of NASA s extraterrestrial samples, including those from future missions. This responsibility includes the development of new sample handling and preparation techniques; therefore, the Astromaterials Curator must begin developing procedures to preserve, prepare and ship samples at sub-freezing temperatures in order to enable future sample return missions. Such missions might include the return of future frozen samples from permanently-shadowed lunar craters, the nuclei of comets, the surface of Mars, etc. We are demonstrating the ability to curate samples under cold conditions by designing, installing and testing a cold curation glovebox. This glovebox will allow us to store, document, manipulate and subdivide frozen samples while quantifying and minimizing contamination throughout the curation process.

Fletcher, L. A.↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

Cibuzar, Branelle R.↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

Rodriguez, Branelle R.↗

Studies of Thermophysical Properties of Metals and Semiconductors by Containerless Processing Under Microgravity

Electromagnetic levitation under microgravity provides unique opportunities for the investigation of liquid metals, alloys and semiconductors, both above and below their melting temperatures, with minimized disturbances of the sample under investigation. The opportunity to perform such experiments will soon be available on the ISS with the EML payload which is currently being integrated. With its high-performance diagnostics systems EML allows to measure various physical properties such as heat capacity, enthalpy of fusion, viscosity, surface tension, thermal expansion coefficient, and electrical conductivity. In studies of nucleation and solidification phenomena the nucleation kinetics, phase selection, and solidification velocity can be determined. Advanced measurement capabilities currently being studied include the measurement and control of the residual oxygen content of the process atmosphere and a complementary inductive technique to measure thermophysical properties.

Seidel, A.↗

High-resolution in situ electrochemical NMR with interdigitated electrodes

A system for carrying out electrochemical nuclear magnetic resonance spectroscopy (EC-NMR) is disclosed, along with methods of manufacturing the EC-NMR system, and methods of using the EC-NMR system to monitor electrochemical reactions. The system comprises interdigitated electrodes arranged in a cylindrically symmetric manner. The system allows for nuclear magnetic resonance spectroscopy to be carried out on a sample during electrolysis with minimal effect to its sensitivity.

Tong, YuYe J.↗