Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Characterizations of two-photon absorption process induced by defects in aluminum nitride using Z-scan method

Abstract In this work, we reported two-photon absorption (TPA) measurements for aluminum vacancies in Aluminum nitride single crystals. We measured the linear transmission and identified the defect levels. Using the Z-scan method, we measured the TPA coefficients of the transitions between defect levels from 380 nm to 735 nm. The transition occurs between the aluminum vacancies defect levels. Furthermore, the power dependence shows good linear fitting, confirming the TPA mechanism. These results will be helpful for the design and fabrication of ultra-low loss waveguides and integrated photonics in the ultraviolet spectral range.

Engineering↗

R-matrix approach to collision processes: Study of the threshold behavior of {gamma}+He {yields} He{sup +}(2s)+e{sup -} or He{sup +}(2p)+e{sup -}

We report on a study of one-photon single ionization of He(1s{sup 2}) accompanied by excitation to He{sup +}(2s) or He{sup +}(2p) for photon energies at, and up to a few eV above, the excitation threshold. We find, both numerically and analytically, that as the photon energy approaches threshold from above the photoionization cross section turns sharply at about 200 meV and has a cusp at threshold. The cusp is associated with the adiabatic transfer of population between the 2s and 2p bound states of the ion. The photoelectron's electric field induces an energy splitting between the otherwise degenerate 2s and 2p states, and consequently the 2s and 2p populations oscillate with a period defined by this energy splitting. The number of oscillations is almost independent of the photoelectron's asymptotic speed v since over most of its outward journey the photoelectron moves with a speed much larger than v. However, on the last leg of its journey, after it has slowed down sufficiently in the Coulomb field of the ion, the photoelectron does move with an almost constant speed v. On this last leg the energy splitting is so small that there is insufficient time for 2s and 2p populations to undergo a full oscillation; rather, the (equal and opposite) changes in the 2s and 2p populations are proportional to v (i.e., to the square root of the excess photoelectron energy, which gives rise to a cusp).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-Particle Spectroscopy as a Versatile Tool to Explore Lower-Dimensional Structures of Inorganic Perovskites

The remarkable defect tolerant nature of inorganic cesium halide perovskites leading to near unity photoluminescence (PL) quantum yield (QY) and narrow emission linewidth across the entire visible spectrum, have provided a tantalizing platform for a development of a plethora of light-emitting applications. Recently, lower dimensional (2D, 1D, and 0D) perovskites have attracted further attention due to the enhanced thermal, photo and chemical stability as compared to their three-dimensional (3D) analogues. Combination of the external size quantization and internal octahedral organization provides a unique opportunity to study and harness “multidimensional” electronic properties engineered both on atomic scale and the nanoscale. However, crucial research to understand the elementary charge carrier dynamics in lower dimensional perovskites lags far behind the enormous effort to incorporate them into optoelectronic devices. In this Perspective, we provide a review of recent developments that focus on studies of the dynamics of excitonic complexes in Cs-based perovskite nanocrystals using single-particle time-resolved PL spectroscopy and photon correlation measurements. Single photon statistical studies not only offer the unprecedented level of detail to directly assess various recombination pathways but also provide insights into specifics of carrier’s localization. Further, we discuss the underlying physicochemical processes that govern PL emission and draw attention to a number of attributes within this class of the materials, especially lower-dimensional perovskites that may indicate the common origin of the PL emission, as well as provide a route map for the vast unexplored territories where single particle spectroscopy can be a powerful tool to unravel crucial information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combustion chemistry of the propanol isomers - investigated by electron ionization and VUV-photoionization molecular-beam mass spectrometry

The combustion of 1-propanol and 2-propanol was studied in low-pressure, premixed flat flames using two independent molecular-beam mass spectrometry (MBMS) techniques. For each alcohol, a set of three flames with different stoichiometries was measured, providing an extensive data base with in total twelve conditions. Profiles of stable and intermediate species, including several radicals, were measured as a function of height above the burner. The major-species mole fraction profiles in the 1-propanol flames and the 2-propanol flames of corresponding stoichiometry are nearly identical, and only small quantitative variations in the intermediate species pool could be detected. Differences between flames of the isomeric fuels are most pronounced for oxygenated intermediates that can be formed directly from the fuel during the oxidation process. The analysis of the species pool in the set of flames was greatly facilitated by using two complementary MBMS techniques. One apparatus employs electron ionization (EI) and the other uses VUV light for single-photon ionization (VUV-PI). The photoionization technique offers a much higher energy resolution than electron ionization and as a consequence, near-threshold photoionization-efficiency measurements provide selective detection of individual isomers. The EI data are recorded with a higher mass resolution than the PI spectra, thus enabling separation of mass overlaps of species with similar ionization energies that may be difficult to distinguish in the photoionization data. The quantitative agreement between the EI- and PI-datasets is good. In addition, the information in the EI- and PI-datasets is complementary, aiding in the assessment of the quality of individual burner profiles. The species profiles are supplemented by flame temperature profiles. The considerable experimental efforts to unambiguously assign intermediate species and to provide reliable quantitative concentrations are thought to be valuable for improving the mechanisms for higher alcohol combustion. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

137 Ba Double Gamma Decay Measurement with GAMMASPHERE

The study of the electromagnetic moments (EM), and decay probability, provides detailed information about nuclear wave functions. The well-know properties of EM interactions are good for extracting information about the motion of nucleons. Higher order EM processes always occur, but are usually too weak to be measured. In the case of a 0 + → 0 + transitions, where a single gamma transition is forbidden, the simultaneous emission of two γ-rays has been studied. An interesting opportunity to further investigate 2-photon emission phenomena is by using a standard 137 Cs source populating, via β-decay, the J π = 11/2 - isomeric state at 662 keV in 137 Ba. In this case, two photon process can have contributions from quadrupole-quadrupole or dipole-octupole multipolarities in direct competition with the high multipolarity M4 decay. Since the yield of the double gamma decay is around six orders of magnitude less than the first order transition, very good statistics are needed in order to observe the phenomena and great care must be taken to suppress the first-order decay. The Gammasphere array is ideal since its configuration allows a good coverage of the angular distribution and the Compton events can be suppressed. Nevertheless the process to understand and eliminate the Compton background is a challenge. Geant4 simulations were carried out to help understand and correct for those factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Azimuthal single- and double-spin asymmetries in semi-inclusive deep-inelastic lepton scattering by transversely polarized protons

A comprehensive set of azimuthal single-spin and double-spin asymmetries in semi-inclusive leptoproduction of pions, charged kaons, protons, and antiprotons from transversely polarized protons is presented. These asymmetries include the previously published HERMES results on Collins and Sivers asymmetries, the analysis of which has been extended to include protons and antiprotons and also to an extraction in a three-dimensional kinematic binning and enlarged phase space. They are complemented by corresponding results for the remaining four single-spin and four double-spin asymmetries allowed in the one-photon-exchange approximation of the semi-inclusive deep-inelastic scattering process for target-polarization orientation perpendicular to the direction of the incoming lepton beam. Among those results, significant non-vanishing cos ( Φ–Φ S ) modulations provide evidence for a sizable worm-gear (II) distribution, ${g}_{1\mathrm{T}}^q\left(x,{\mathrm{p}}_T^2\right)$. Most of the other modulations are found to be consistent with zero with the notable exception of large sin ( Φ S ) modulations for charged pions and K + .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum interferometry and pathway selectivity in the nonlinear response of photosynthetic excitons

We propose a time–frequency resolved spectroscopic technique which employs nonlinear interferometers to study exciton–exciton scattering in molecular aggregates. A higher degree of control over the contributing Liouville pathways is obtained as compared to classical light. We show how the nonlinear response can be isolated from the orders-of-magnitude stronger linear background by either phase matching or polarization filtering. Both arise due to averaging the signal over a large number of noninteracting, randomly oriented molecules. We apply our technique to the Frenkel exciton model which excludes charge separation for the photosystem II reaction center. We show how the sum of the entangled photon frequencies can be used to select two-exciton resonances, while their delay times reveal the single-exciton levels involved in the optical process.

Science & Technology - Other Topics↗

Attosecond Intramolecular Scattering and Vibronic Delays

We study the temporal and vibrational signature of the universal nuclear recoil associated with the electron emission and intramolecular scattering that accompanies the photoelectric effect. We illustrate these phenomena in the photoionization of the CO molecule from the C-1s orbital using an analytical model that reproduces the entangled character of the nuclear and electronic motion in this process. We show that the photoelectron emission delay can be decomposed into its localization and resonant-confinement components. Photoionization by a broadband x-ray pulse results in a coherent vibrational ionic state delayed compared to the classical sudden-photoemission limit.

74 ATOMIC AND MOLECULAR PHYSICS↗

An automated voxelized dosimetry tool for radionuclide therapy based on serial quantitative SPECT/CT imaging

Purpose: To create an accurate map of the distribution of radiation dose deposition in healthy and target tissues during radionuclide therapy.Methods: Serial quantitative SPECT/CT images were acquired at 4, 24, and 72 h for 28 {sup 177}Lu-octreotate peptide receptor radionuclide therapy (PRRT) administrations in 17 patients with advanced neuroendocrine tumors. Deformable image registration was combined with an in-house programming algorithm to interpolate pharmacokinetic uptake and clearance at a voxel level. The resultant cumulated activity image series are comprised of values representing the total number of decays within each voxel's volume. For PRRT, cumulated activity was translated to absorbed dose based on Monte Carlo-determined voxel S-values at a combination of long and short ranges. These dosimetric image sets were compared for mean radiation absorbed dose to at-risk organs using a conventional MIRD protocol (OLINDA 1.1).Results: Absorbed dose values to solid organs (liver, kidneys, and spleen) were within 10% using both techniques. Dose estimates to marrow were greater using the voxelized protocol, attributed to the software incorporating crossfire effect from nearby tumor volumes.Conclusions: The technique presented offers an efficient, automated tool for PRRT dosimetry based on serial post-therapy imaging. Following retrospective analysis, this method of high-resolution dosimetry may allow physicians to prescribe activity based on required dose to tumor volume or radiation limits to healthy tissue in individual patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Search for anomalous neutral current coherent-like single-photon production in MicroBooNE

This note describes progress towards the first experimental search for neutrino-induced neutral current coherent single-photon production (NC coherent 1γ). The search makes use of data from the MicroBooNE’s 85-tonne active mass liquid argon time projection chamber detector, situated in Fermilab’s Booster Neutrino Beam, with an average neutrino energy of $\langle$E ν $\rangle$ ~ 0.8 GeV. A selection targeted on candidate neutrino interactions with a single photon-like electromagnetic shower in the final state and no visible vertex activity was developed to search for this rare NC coherent 1γ process.

43 PARTICLE ACCELERATORS↗

Ultrafast Fiber Bragg Grating Interrogation for Sensing in Detonation and Shock Wave Experiments

Chirped fiber Bragg grating (CFBG) sensors coupled to high speed interrogation systems are described as robust diagnostic approaches to monitoring shock wave and detonation front propagation tracking events for use in high energy density shock physics applications. Taking advantage of the linear distributed spatial encoding of the spectral band in single-mode CFBGs, embedded fiber systems and associated photonic interrogation methodologies are shown as an effective approach to sensing shock and detonation-driven loading processes along the CFBG length. Two approaches, one that detects spectral changes in the integrated spectrum of the CFBG and another coherent pulse interrogation approach that fully resolves its spectral response, shows that 100-MHz–1-GHz interrogation rates are possible with spatial resolution along the CFBG in the 50 µm to sub-millimeter range depending on the combination of CFBG parameters (i.e., length, chirp rate, spectrum) and interrogator design specifics. In conclusion, results from several dynamic tests are used to demonstrate the performance of these high speed systems for shock and detonation propagation tracking under strong and weak shock pressure loading: (1) linear detonation front tracking in the plastic bonded explosive (PBX) PBX-9501; (2) tracking of radial decaying shock with crossover to non-destructive CFBG response; (3) shock wave tracking along an aluminum cylinder wall under weak loading accompanied by dynamic strain effects in the CFBG sensor.

36 MATERIALS SCIENCE↗

First Search for Neutral Current Coherent Single-Photon Production in MicroBooNE

This article presents the first search for neutrino-induced neutral current coherent single-photon production (NC coherent 1$\gamma$). The search makes use of data from the MicroBooNE 85-tonne active volume liquid argon time projection chamber detector, situated in the Fermilab Booster Neutrino Beam (BNB), with an average neutrino energy of $\langle E_{\nu}\rangle \sim 0.8$ GeV. A targeted selection of candidate neutrino interactions with a single photon-like electromagnetic shower in the final state and no visible vertex activity was developed to search for the NC coherent 1$\gamma$ process, along with two auxiliary selections used to constrain the dominant background from NC$\pi^0$ production. With an integrated exposure of $6.87 \times 10^{20}$ protons on target delivered by the BNB, we set the world's first limit for this rare process, corresponding to an upper limit on the flux-averaged cross section of $\sigma<1.49 \times 10^{-41}\text{cm}^2$ at 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A non-Markovian model of avalanche gain statistics for a solid-state photomultiplier

A solid-state photomultiplier (SSPM) capable of continously detecting individual photons of wavelength between 0.4 and 28 microns has recently been disclosed (Petroff et al., 1987). The initial response of the SSPM to single photon is a fast, high-amplitude current pulse of between 10,000 and 100,000 electrons. A phenomenological model of the SSPM avalanche process is presented which successfully predicts the shape of the observed pulse-amplitude distribution by including small history-dependent effects on the carrier transport. The model clarifies the consequences of the electric field strength and the scattering of the electrons for the development of the avalanche in the SSPM.

Laviolette, Randall A.↗

A long-range laser velocimeter for the National Full-Scale Aerodynamics Complex: New developments and experimental application

A long-range laser velocimeter (LV) developed for remote operation from within the flow fields of the large wind tunnels of the National Full-Scale Aerodynamics Complex is described. Emphasis is placed on recent improvements in optical hardware as well as recent additions to data acquisition and processing techniques. The system has been upgraded from a dual-beam, single-color LV with focal range to 10 m, to a dual-beam, two-color LV with focal range to 20 m. At the new extended measurement range (between 10 and 20 m), signals are photon-resolved, and a photon correlation technique is applied to acquire and process the LV signals. This technique permits recovery of the velocity probability distributions at a particular measurement location from which the mean components of velocity and the corresponding normal stress components of turbulence are obtained. The method used for data reduction is outlined in detail, and a discussion of measurement accuracy is made. To study the performance of the LV and verify the measurement accuracy, laboratory measurements were made in the flow field of a 10 cm-diameter, 30-m/sec axisymmetric jet. A discussion of the requirements and techniques used to seed the flow is made, and boundary-layer surveys of mean velocity and turbulence intensity of the streamwise component and the component normal to the surface are presented.

Reinath, Michael S.↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of local micro-breakdown in the Geiger mode of avalanche photodiodes

Mathematical modeling methods were used to study the dynamics of micro-breakdown development in structures of silicon avalanche photodiodes. The constructed model considers the locality of the avalanchexs multiplication region appearing during single photon absorption and the delay of the avalanchexs current spreading over the rear electrode of the diode. The calculations showed two different phases of transient process of the formation of the electrical signal, i.e., the rapid and slow ones due to current spreading and ordinary RC recharge, respectively. The load resistances required to implement the pulsed mode of operation of the structures of the avalanche photodiode were calculated for a series of actual diode capacitances and spreading resistances of the rear electrode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiquark matrix elements in the proton and three gluon exchange for exclusive $η_c$ production in photon-proton diffractive scattering

Exclusive production of a η c pseudoscalar meson in γ ( * ) + p → η c + p scattering at high energies involves a C -odd exchange in the t -channel. We formulate the description of this process within the high-energy framework of eikonal dipole scattering. We obtain expressions for the light-cone wave function of the η c required in this framework as well as for the C -odd amplitudes due to exchange of a single photon, of a photon plus two gluons, and of three gluons. We relate these amplitudes to correlators of the plus component of the quark current in the light-cone wave function of the proton. For high transverse momenta, these correlators correspond to (leading twist) generalized parton distributions given by diagrams where all exchanged gauge bosons attach to a single quark in the proton. Diagrams involving multiquark matrix elements potentially sensitive to correlations screen infrared singularities. Moreover, they are numerically important for configurations where the exchanged bosons nearly share the total momentum transfer. Using two simple models for the three-quark Fock state of the proton at x ≃ 0.1 , we find that single photon exchange dominates for | t | < 1.5 GeV 2 . Here, the quark generalized parton distribution could be measured cleanly in γ ( * ) + p → η c + p via single photon exchange. For higher momentum transfer, three-gluon (“Odderon”) exchange is dominant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗