Search NASA⌕ Search

SEARCH · Search NASA

Results for “site evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Recovery of Rare Earth Elements from Coal Mining Waste Materials

The objective of this proposed project was to locate coal overburden material that had rare earth elements (REEs) at concentrations of 300 ppm or higher. After securing the feedstock the next goal was to efficiently extract and purify the feedstocks to a purity of greater than 95%. A techno economic analysis was conducted to determine the economic viability of mining and processing REEs associated with Appalachian coal deposits. All aspects of mining, mineral processing, by-product potential, waste management, permitting and economics were examined. Attention was paid to the separation, degree of purification and marketing of Rare Earth elements. Along with REEs we evaluated the economics of the recovery of other metals of interest aong with the REEs. Our site location chosen was at the Jeddo Coal Site near Hazleton, Pennsylvania. The primary site was at the Upper Leigh High Mine. However, that changed to the North Eckley Mine site. We have analyzed a third site that will now be our second alternative to North Eckley. That site is the Highland mine site. This site is in a similar basin as the North Eckley site. During this project we evaluated various acids and extraction conditions. We have settled on using HCl as the acid of choice. One of the advantages of using HCl is it allows for easy removal of the highest contaminating metal, iron. When iron reacts with HCl in the presence of high chlorides it creates the anion complex FeCl 4 -1 . This FeCl 4 -1 complex will bind with an anion exchange resin. Greater than 99.8% of the iron is removed with this technique. Once the FeCl 4 -1 complex is bound to the anion exchange resin it can be released easily by just passing water over it. This water dilutes the FeCl 4 -1 to form FeCl 3 which is not anionic and therefore not attracted to the anion exchange resin. The FeCl 3 solution is a popular water flocculating agent used all over the world for water purification. We plan on this being one of our products produced. One of our goals was to create a multipurpose facility that was capable of handling multiple feedstocks. The proposed multipurpose facility will be able process all coal biproducts and coal products. These include 1.) clays that can easily be leached with ion exchange or acid 2.) Hard mineral deposits that can be leached with high pressure acid digestion 3.) Fly ash can be leached in the high-pressure acid digestion reactor. Fly ash is not a focus of this proposal but, the beneficial aspect of its utilization in this design cannot be overlooked. 4.) Acid Mine Drainage (AMD) Sludge is a high source of REE’s and can easily be dissolved to form a pregnant leach solution. Not shown on this simplified block flow diagram but crucial to its success is the recycle of acids. Our REE separation system is a continuous ion exchange process. The first stage is the separation of the non-REEs from the REEs. This is accomplished because the REEs are relatively larger than most of the non-REEs and typically have higher oxidation states (+3) than the non-REEs. In this step all the elements stick onto the column. However, as the columns are rinsed with various concentrations of acids different elements come off. For example, monovalent elements such as sodium and potassium elute off the column with a 1M HCl solution. Divalent elements such as calcium and magnesium do not elute until a 2M HCl solution is passed over the columns. The trivalent elements (REEs) are not eluted until a much higher concentrated acid is passed of the columns. Iron is also a trivalent, but it was removed in a prior anion exchange system. Aluminum is trivalent too, but it is much smaller than the REE atoms and elutes near the end of the 2 M HCl with the divalents. At the stage 2 and 3 our volume and masses have become too small to run on the continuous system. Therefore, we used a batch chromatography column or a flash chromatography column. The stage 2 process separates these REEs into 3 different fractions. A light, mid and heavy fraction. We calculated that we recovered greater than 90% of the REEs. This third column was packed with a different stationary phase. Five elements were chosen and purified to higher than 95% purity as shown by our internal testing. These elements were shipped to the DOE.

01 COAL, LIGNITE, AND PEAT↗

A Deep Exon Cryptic Splice Site Promotes Aberrant Intron Retention in a Von Willebrand Disease Patient

A translationally silent single nucleotide mutation in exon 44 (E44) of the von Willebrand factor (VWF) gene is associated with inefficient removal of intron 44 in a von Willebrand disease (VWD) patient. This intron retention (IR) event was previously attributed to reordered E44 secondary structure that sequesters the normal splice donor site. We propose an alternative mechanism: the mutation introduces a cryptic splice donor site that interferes with the function of the annotated site to favor IR. We evaluated both models using minigene splicing reporters engineered to vary in secondary structure and/or cryptic splice site content. Analysis of splicing efficiency in transfected K562 cells suggested that the mutation-generated cryptic splice site in E44 was sufficient to induce substantial IR. Mutations predicted to vary secondary structure at the annotated site also had modest effects on IR and shifted the balance of residual splicing between the cryptic site and annotated site, supporting competition among the sites. Further studies demonstrated that introduction of cryptic splice donor motifs at other positions in E44 did not promote IR, indicating that interference with the annotated site is context dependent. We conclude that mutant deep exon splice sites can interfere with proper splicing by inducing IR.

60 APPLIED LIFE SCIENCES↗

Distribution of Infiltration in the 216-U-10 and 216-B-3 Pond Systems 1944-1997

A modeling system to simulate fate and transport of contaminant plumes in groundwater beneath the Central Plateau to support the Cumulative Impact Evaluation (CIE) and Composite Analysis (CA) is being developed. The CIE will evaluate the cumulative effect of multiple Central Plateau radiological and chemical sources on groundwater quality (DOE/RL-2018-69, Cumulative Impact Evaluation Technical Approach Document ). This will enable cleanup decisions to be evaluated in the context of all Central Plateau waste sites and existing groundwater conditions. The CA evaluates the cumulative effect of all sources of radioactive materials on radiological dose to future members of the public (DOE/RL-2018-60, Annual Status Report (FY 2018): Composite Analysis of Low Level Waste Disposal in the Central Plateau of the Hanford Site ). Fate and transport modeling will be used to forecast future groundwater concentrations for both the CIE and CA. The CIE/CA subsurface modeling system is divided into source (inventory), vadose zone, and saturated zone facets. Source inventory is a necessary input to the vadose zone facet, and releases from the vadose zone to groundwater are inputs to the saturated zone facet. The vadose zone facet simulates historical and future releases from the vadose zone to groundwater for both liquid waste and solid waste disposal sites. Effluent release volumes and radionuclide inventory estimates for liquid waste sites are contained in ECFHANFORD- 17-0079, Hanford Soil Inventory Model (SIM-v2) Calculated Radionuclide Inventory of Direct Liquid Discharges to Soil in the Hanford Site’s 200 Areas , herein referred to as SIM-v2. The liquid waste sites in SIM-v2 include the 216-B-3 Pond near 200 East Area and the 216-U-10 Pond in 200 West Area. The 216-B-3 Pond system consisted of a main pond and 3 expansion lobes that were operational during overlapping time periods. It also included influent ditches, but these are not listed as liquid waste sources in SIM-v2 and are not included in the CIE/CA modeling. The total effluent volume released to the pond system was measured, but the partitioning of this volume to the various expansion lobes was not determined and is not accounted for in SIM-v2. Regarding the 216-U-10 Pond, it received water from several influent ditches. The pond and the influent ditches are listed as liquid waste sites in SIM-v2 and are included as sources in the CIE/CA modeling. Because water in the ditches flowed into the pond, only a portion of the effluent volumes and contaminant inventories assigned to the ditches in SIM-v2 infiltrated from the ditches. Thus, partitioning of infiltration and contaminant inventories between the ditches and the pond is not fully accounted for in SIM-v2. Further, some of the water in the 216-U-10 Pond entered overflow ditches and the amount of this overflow was not recorded and is not accounted for in SIM-v2. Thus, the purpose of this Environmental Calculation File (ECF) is to partition the infiltration of wastewater and contaminant inventory between the main pond and each expansion lobe of the 216-B-3 Pond system, and to partition the infiltration of wastewater and contaminant inventory between the ditches and pond of the 216-U-10 Pond system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lidar-Based Evaluation of HRRR Performance in California’s Diablo Range

The performance of the NOAA High-Resolution Rapid Refresh (HRRR) model for capturing low-level winds near a wind energy production site during summer 2019 is evaluated. This study catalogs the ability of HRRR to predict boundary layer dynamics relevant to wind energy interests over complex terrain, which has presented challenges for weather and energy forecasting. Performance is evaluated by comparing HRRR output to wind-profiling Doppler lidars at Lawrence Livermore National Laboratory Site 300. HRRR captured the diurnal profile of horizontal winds in the observed 150-m layer, despite strong underpredictions (∼4 m s −1 ) during evening and nighttime hours. These underpredictions may be a result of local speedup flows observed by the lidars, which were unresolved in HRRR due to their small spatial extent. HRRR bias magnitude relative to observations was found to be minimal during days with synoptic-scale troughs and strong 850-hPa geopotential gradients, while bias magnitude was maximal during days with synoptic ridging and weak 850-hPa geopotential gradients. To translate wind speed predictions to energy forecasting, generic turbine models were used to estimate power generation for turbines characteristic of the nearby Altamont Pass Wind Resource Area. Results show that HRRR-based energy estimates predicted daytime power generation adequately relative to lidar-based estimates with an 18-h lead time (bias magnitude < 0.4 MW from 0900 to 1400 LT) but overpredicted power during the rest of the diurnal cycle (bias > 1 MW). These results demonstrate conditions under which HRRR performs well for wind energy applications in complex terrain, while highlighting biases that require further investigation to support usage of a high-resolution model for wind energy forecasts.

Boundary layer↗

2024 Results for Avian Monitoring at the Technical Area 36 Minie Site, Technical Area 39 Point 6, Technical Area 16 Burn Ground, and DARHT at Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) biological subject matter experts in the Environmental Protection and Compliance Division initiated a multi-year program in 2013 to monitor avifauna (birds) at two open detonation sites and one open burn site on LANL property. Additional monitoring began in 2017 at a third firing site, the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility. In this annual report, we compare monitoring results from these efforts among years to identify and evaluate firing and open burn site impacts on the local bird community. The objectives of this study are • to determine whether LANL operations impact bird abundance, species richness, or diversity; • to examine occupancy and nest success of secondary-cavity nesting birds that use nest boxes; and • to examine chemical concentrations (such as radionuclides, inorganic elements, and/or organic compounds) in nonviable eggs and deceased nestlings that are collected opportunistically with the upper-level bounds of background concentrations, when available. During May through July 2024, LANL biologists completed multiple avian point count surveys at each of the following treatment sites: • Technical Area (TA) 36 Minie Site, • TA-39 Point 6, • TA-16 Burn Ground, and • DARHT. We recorded a total of 1,088 birds that represented 65 species at the four treatment sites and compared these results with data from their associated control sites. In 2024, abundance and species richness at treatment and control sites continued to trend similarly from year to year, with minor random deviations expected from bird communities. Species richness at firing sites differed little from the previous year’s values. Two new bird species were observed at the firing sites—cedar waxwing (Bombycilla cedrorum) and pinyon jay (Gymnorhinus cyanocephalus). Shannon diversity values at TA-36 Minie Site, TA-39, and DARHT were statistically higher than one or more of their associated controls. Annual species diversity at treatment sites was high in 2024 across all firing sites relative to similar habitat control sites. We also monitored avian nest boxes to compare occupancy and nest success data from nest boxes at treatment sites with the overall avian nest box monitoring network and against a subset of relevant control sites. Nest box success has decreased at both treatment and control sites since monitoring began, suggesting that overlapping climatic factors are responsible for patterns of declining nest success. In 2024, nonviable avian eggs and one nestling were opportunistically collected at Bandelier National Monument, TA-16 Burn Ground, TA-36 Minie, TA-39 Point 6, and DARHT. All egg samples and the one nestling sample were evaluated for per- and polyfluoroalkyl substances, which were detected from all locations, including the control site at Bandelier National Monument. Overall results from 2024 continue to suggest that operations at the four treatment sites are not negatively impacting bird populations. This long-term project will continue to monitor for any changes over time.

54 ENVIRONMENTAL SCIENCES↗

EO-1 Hyperion Reflectance Time Series at Calibration and Validation Sites: Stability and Sensitivity to Seasonal Dynamics

This study evaluated Earth Observing 1 (EO-1) Hyperion reflectance time series at established calibration sites to assess the instrument stability and suitability for monitoring vegetation functional parameters. Our analysis using three pseudo-invariant calibration sites in North America indicated that the reflectance time series are devoid of apparent spectral trends and their stability consistently is within 2.5-5 percent throughout most of the spectral range spanning the 12-plus year data record. Using three vegetated sites instrumented with eddy covariance towers, the Hyperion reflectance time series were evaluated for their ability to determine important variables of ecosystem function. A number of narrowband and derivative vegetation indices (VI) closely described the seasonal profiles in vegetation function and ecosystem carbon exchange (e.g., net and gross ecosystem productivity) in three very different ecosystems, including a hardwood forest and tallgrass prairie in North America, and a Miombo woodland in Africa. Our results demonstrate the potential for scaling the carbon flux tower measurements to local and regional landscape levels. The VIs with stronger relationships to the CO2 parameters were derived using continuous reflectance spectra and included wavelengths associated with chlorophyll content and/or chlorophyll fluorescence. Since these indices cannot be calculated from broadband multispectral instrument data, the opportunity to exploit these spectrometer-based VIs in the future will depend on the launch of satellites such as EnMAP and HyspIRI. This study highlights the practical utility of space-borne spectrometers for characterization of the spectral stability and uniformity of the calibration sites in support of sensor cross-comparisons, and demonstrates the potential of narrowband VIs to track and spatially extend ecosystem functional status as well as carbon processes measured at flux towers.

Calibration↗

Regional Rates of Young US Forest Growth Estimated From Annual Landsat Disturbance History and IKONOS Stereo Imagery

Forests of the Contiguous United States (CONUS) have been found to be a large contributor to the global atmospheric carbon sink. The magnitude and nature of this sink is still uncertain and recent studies have sought to define the dynamics that control its strength and longevity. The Landsat series of satellites has been a vital resource to understand the long-term changes in land cover that can impact ecosystem function and terrestrial carbonstock. We combine annual Landsat forest disturbance history from 1985 to 2011 with single date IKONOS stereoimagery to estimate the change in young forest canopy height and above ground live dry biomass accumulation for selected sites in the CONUS. Our approach follows an approximately linear growth rate following clearing over short intervals and does not estimate the distinct non-linear growth rate over longer intervals.We produced canopy height models by differencing digital surface models estimated from IKONOS stereo pairs with national elevation data (NED). Correlations between height and biomass were established independently using airborne LiDAR, and then applied to the IKONOS-estimated canopy height models. Graphing current biomass against time since disturbance provided biomass accumulation rates. For 20 study sites distributed across five regions of the CONUS, 19 showed statistically significant recovery trends (p is less than 0.001) with canopy growth from 0.26 m yr-1to 0.73 m yr-1. Above ground live dry biomass (AGB) density accumulation ranged from 1.31 t/ha yr-1 to 12.47 t/ha yr-1. Mean forest AGB accumulationwas 6.31 t/ha yr-1 among all sites with significant growth trends. We evaluated the accuracy of our estimates by comparing to field estimated site index curves of growth, airborne LiDAR data, and independent model predictions of C accumulation. Growth estimates found with this approach are consistent with site index curves and total biomass estimates fall within the range of field estimates. This is aviable approach to estimate forest biomass accumulation in regions with clear-cut harvest disturbances.

Neigh, Christopher S. R.↗

Evaluation of Hypotheses for the Fate of Historical Discharges from Hanford Site BC Cribs and Trenches

A preliminary review of declassified reports and historical documents from the 1950s and 1960s indicated they may contain valuable information regarding potential impacts to groundwater from liquid waste discharged to the 216-BC Cribs and Trenches during the late 1950s. Transport of contaminants in the vadose zone beneath the BC Cribs area is simulated by a vadose zone model developed for the Composite Analysis (DOE/RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau ). Results from this model indicate there has been no substantial breakthrough of contaminants (particularly technetium-99) to groundwater from the vadose zone up to the present day. However, there is uncertainty in the anisotropy and other model input parameters as well as acknowledged sparseness of sampling data for this area. In this study, historical documents and other information were reviewed to evaluate the possibility that contaminant breakthrough to groundwater occurred during or shortly after operation of the BC Cribs sites, and whether refinements of the vadose zone model parametrization should be considered.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing a chemical cleaning protocol to determine the nickel isotopic composition of ancient seawater from carbonates

Reconstructing the ancient marine cycle of Ni, a trace metal in the oceans essential to enzymes regulating the C, N, and O cycles, would inform how Ni bioavailability shaped early life. The Ni isotopic composition of seawater (δ 60 Ni SW ) through time could provide insight, but this approach requires sedimentary archives that faithfully record δ 60 Ni SW . Carbonates are an often-used record of seawater chemistry, but contaminants could bias the measured δ 60 Ni of bulk sediment. To isolate the true carbonate-bound δ 60 Ni signal, we optimized a chemical cleaning protocol designed to minimize non‑carbonate Ni contributions and maximize carbonate recovery. We analyzed ODP Site 1007 sediments and evaluated oxidative and reductive pre-cleaning steps and carbonate dissolution protocols. Our results show that only reductive cleaning significantly altered the subsequent carbonate leachate composition, lowering Ni/Ca ratios by up to 60% and δ 60 Ni values by as much as 0.4 ‰. In contrast, δ 60 Ni values were largely insensitive to premature carbonate dissolution during pre-cleaning or to partial leaching of silicates during carbonate dissolution, even at higher acid molarities or longer reaction times. We recommend an evidence-based protocol that removes hydro-soluble salts and clays, applies reductive cleaning and oxidative cleaning for certain sample compositions, and dissolves carbonate using 0.5 M acetic acid, adjusted to pH 5. Using these results, we infer a ∼ 0.9 ‰ Ni isotopic fractionation between chemically cleaned deep-water carbonates (+0.4 ± 0.1 ‰) and deep seawater. This method development is a key step toward accurately reconstructing ancient marine Ni cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing monitoring networks for local earthquakes

Abstract Seismic networks are essential for monitoring local earthquakes in connection to industrial activities, including wastewater injection and CO2 sequestration. Because these networks are typically deployed for short periods of time at specific sites, it is beneficial to develop best practices for efficient and effective installation and monitoring. Such standards are available for regional earthquake and microseismic monitoring, but not readily available for local scale (tens of kilometer scale) monitoring. Once the region of interest has been determined, the key parameters for establishing a network are available monitoring station locations, site noise, and site utility. Networks should be designed based on the project monitoring goals for earthquake magnitude and density. Herein, a network was established at the Patterson and Hartland Oil Fields in western Kansas in association with a US Department of Energy CarbonSAFE carbon capture and sequestration research project. We employed observations from an analog local network, the Wellington Earthquake Monitoring Network in south-central Kansas, to assess site noise and estimate earthquake detection thresholds for the Patterson and Hartland fields. Noise from oil production facilities was evaluated, concluding that oil lease sites are suitable for monitoring small local earthquakes (M1-M3). The network was designed to have a magnitude of completeness of M1 while using station locations on existing field operator leases. Fifteen months of continuous network operation demonstrates reliable and efficient local earthquake monitoring and provides best practices recommendations for similar operations.

58 GEOSCIENCES↗

Laboratory Investigations

The primary objectives were to examine the site-specific physical, chemical, and biological factors that impact construction, durability and performance of the proposed 5-MW (sub e) solar pond system at the Salton Sea. The interactions of the water, salt, and soil of the site and on material compatibility were examined. Potential interactions of the water/brine and soil are particularly important because the pond will utilize the naturally occurring clays as a bottom seal. Although there is a considerable and growing solar pond literature, little written information deals with the important site-specific investigations of water, salt, and soil. Therefore, technical effort was directed toward identifying the factors that should be investigated and determining methods of investigation. As a result, a by-product was the development of an approach for site-specific investigations and some specific methodologies. This development should continue in order to establish a generic approach for evaluating the suitability of any site for the construction of large-scale solar ponds.

Source record↗

Use of Physics to Improve Solar Forecast: Physics-Informed Persistence Models for Simultaneously Forecasting GHI, DNI, and DHI

Observation-based statistical models have been widely used in forecasting solar energy; however, existing models often lack a clear relation to physics and are limited largely to global horizontal irradiance (GHI) forecasts over relatively short time horizons (< 1 hour). Incorporating physics into observation-based models, increasing forecast time horizons and developing a model system for forecasting not only GHI but also direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) remain challenging, especially under cloudy conditions because of complex cloud-radiation interactions. This work attempts to address these challenges by developing a hierarchy of four new physics-informed persistence models that can be used to simultaneously forecast GHI, DNI and DHI. The decade-long measurements (1998 to 2014) at the U.S. Department of Energy's Atmospheric Radiation Measurement (ARM)'s Southern Great Plains (SGP) Central Facility site are used to evaluate the performance of the new models. Overall, the results show that the new physics-informed forecast models generally outperform the simple and smart persistence models, and improve the forecast accuracy at lead times from 1.25 hours up to 6 hours. Further analysis reveals that the forecast error is highly related to the error and temporal variability of the assumed cloud predictor. The best model for forecasting different radiative components can be explained by the relationship between solar irradiances and cloud properties.

54 ENVIRONMENTAL SCIENCES↗

Bringing Automated Fault Detection and Diagnostics Tools for HVAC&R Into the Mainstream

Heating, ventilation, and air-conditioning (HVAC) systems consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. commercial buildings. Additionally, commercial refrigeration (R) systems add about 1 quad to commercial buildings energy consumption. Most HVAC systems operate with one or more faults that result in increased energy consumption. Fault detection and diagnostics (FDD) tools have been developed to address this national issue, and many tools are commercially available. FDD tools have the potential to save considerable energy for an existing commercial rooftop unit (RTU) and refrigeration systems. These devices can be used for both retro commissioning and, when faults are addressed, continuous commissioning. However, there appears to be multiple market barriers for this technology. Although there are efforts to develop FDD tool standards, currently there are no standards and methods to define functions, capabilities, accuracy, and reliability of FDD tools in the field. Moreover, most of the commercial FDD tools have not been verified in the field independently. This paper presents a comprehensive approach for bringing HVAC FDD tools into the mainstream. The approach involves demonstrating ten commercially available FDD tools installed at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying and assessing market barriers, creating a process evaluation methodology, and assisting utility companies in developing incentive programs. Furthermore, the preliminary baseline results from the case study demonstrate how the use of an independent monitoring system (IMS) can be used for ground-truth in evaluating FDD tools in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AN APPROACH TO BRINGING AUTOMATED FAULT DETECTION AND DIAGNOSIS (AFDD) TOOLS FOR HVAC&R INTO THE MAINSTREAM

Heating, ventilation and air-conditioning (HVAC) systems can consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. in commercial buildings. Additionally, commercial refrigeration (R) systems add about 2 quads to commercial buildings energy consumption. Most HVAC systems have one or more faults (low/high refrigerant charge, valve leakage, condenser/evaporator fouling, filter/dryer restriction, economizer faults, controls faults) that result in increased energy consumption. Automated fault detection and diagnosis (AFDD) tools have been developed to address this national issue and many tools are commercially available. AFDD tools have the potential to save considerable energy for existing commercial RTUs, chillers and refrigeration systems. These devices can be used for both retro commissioning, and, when faults are addressed, continuous commissioning as well. However, there appears to be multiple market barriers for this technology. A key market barrier for this technology is the lack of awareness of AFDD products among potential customers. Most HVAC contractors are not familiar with the latest AFDD technologies and HVAC technicians lack skills regarding these technologies. Quantifying potential benefits to building owners is difficult since there are several FDD tools with varying capabilities. For instance, there are several FDD products ranging from handling just economizer faults to those that also handle full-blown refrigerant-side and air-side faults. Methods/algorithms used in FDD vary significantly. Even though there are efforts to develop standards, currently there are no standards/methods to define functions, capabilities, accuracy, and reliability of FDD tools. Moreover, most of the commercial AFDD tools have not been verified in the field independently. This paper presents a comprehensive approach to bringing HVAC AFDD tools into the mainstream. The approach involves demonstrating ten commercially available tools at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying market barriers, and assisting utility companies in developing incentive programs. This paper presents selection of AFDD tools, ite identification, and field testing and evaluation method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment for the Disposal of Low Level Waste in the 200 East Area Burial Grounds (FY2019 Annual Status Report)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-730) and are compared with U.S. Department of Energy requirements (DOE O 435.1 and performance objectives defined in companion documents DOE M 435.1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations, indicating that potential impacts are well below performance objectives; therefore, future compliance with DOE O 435.1 is expected. A new PA study has been initiated in this fiscal year (FY) 2019 for evaluation of active disposal sites within the 200 West and East Areas (Trenches 31 and 34 in 200 West; Trench 94 in 200 East) because extended time has elapsed between the current annual status report and the original PA (WHC-SD-WM-TI-370) for the active disposal sites. The new PA for the active disposal sites is expected to be completed in FY 2021.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Status Report (FY 2020): Performance Assessment for the Disposal of Low Level Waste in the 200 East Area Burial Grounds

This annual review provides the projected dose estimates of radionuclide inventories disposed in the 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-730). The estimates are compared with requirements of DOE O 435.1 Chg 1 and performance objectives defined in companion documents DOE M 435.1-1 Chg 1and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 Chg 1 is expected. A new PA study was initiated in fiscal year (FY) 2019 for evaluation of active disposal sites within the 200 East and 200 West Areas (Trench 94 in 200 East; Trenches 31 and 34 in 200 West) due to extended time elapsing between the current annual status report and the original PA for the active disposal sites. The new PA for the active disposal sites is expected to be completed in FY 2021. Within the active burial grounds in the 200 East Area, low-level waste and mixed low-level waste will continue to be disposed of in the dedicated U.S. Navy reactor compartment trench at the 218-E-12B Burial Ground (Trench 94). During this reporting period (FY 2020, from October 1, 2019, through September 30, 2020), two reactor compartments were disposed in Trench 94. Results from sorption experiments are summarized for this reporting period to quantify the efficacy of concrete waste forms in retaining key radionuclides (e.g., technetium-99 and iodine-129). The test durations ranged from 1 to 3 months. Continued groundwater monitoring of the 200 East Area LLBGs indicates no groundwater contamination due to LLBG waste. Current assumptions about future land use at the Hanford Site are consistent with PA analysis1 assumptions of a post-closure facility that will not be degraded by human activity. The LLBGs are located in an area identified for waste management and containment of residual contamination. This area will remain after final environmental remediation and the proposed shrinkage of Hanford Site boundaries to small sections within the 200 East and 200 West Areas in the Central Plateau (DOE/EIS-0391). The current closure plan for the LLBGs (DOE/RL-2000-707) estimates that the 200 East LLBGs will be closed in the 2050 timeframe. The Disposal Authorization Statement, other technical basis documents, and the radioactive waste management basis are of continued adequacy to meet the performance objectives of DOE O 435.1 Chg 1. Overall, there are no substantive changes to primary PA assumptions nor the PA analysis conclusion; therefore, compliance with DOE O 435.1 Chg 1 and the Disposal Authorization Statement is maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Building 23-117, Administration Building, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to update the façade of Building 23-117, Administration Building (Nevada State Historic Preservation Office [SHPO] Resource No. B15256), at the Nevada National Security Site (NNSS) in Nye County, Nevada. The NNSA/NFO is implementing a long-term project to modernize the town of Mercury for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800.

54 ENVIRONMENTAL SCIENCES↗