Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Hydrogen-Bonding Bottlebrush Networks: Self-Healing Materials from Super-Soft to Stiff

The impact of polymer architecture on network dynamics and self-healing is presented using bottlebrushes containing side chains that are end-functionalized with 2-ureido-4[1H]-pyrimidinone (UPy). The synthesis of these materials is straightforward through a three-step process: (1) synthesizing rubbery poly(4-methylcaprolactone) macromonomers (p4MCL–OH) with a norbornene-based initiator, (2) functionalizing the terminal hydroxyl group with UPy–isocyanate (p4MCL–UPy), and (3) statistically copolymerizing p4MCL–OH and p4MCL–UPy via ring-opening metathesis polymerization (ROMP) to form hydrogen-bonding bottlebrushes having a fraction (p) of side chains functionalized with UPy. Attaching UPy to the free end of bottlebrush side chains dilutes the impact of friction from complementary UPy interactions on segmental dynamics, leading to a much weaker dependence of the glass-transition temperature (T g ) on p than observed in linear analogues, while the activation energy to dissociate UPy–UPy bonds (41–47 kJ/mol) remains mostly unchanged. Longer side chains result in a competition between reducing T g and inducing entanglements that influence hydrogen-bonded network dynamics. Increasing the backbone length extends the sticky Rouse region without affecting the network modulus (G x ) or UPy–UPy dissociation time (τ s ). Gx scales linearly with p and ranges from 27 kPa to 1.6 MPa, while τs remains nearly constant in contrast to linear telechelic ionomers, implying a similar self-healability across bottlebrush networks containing different amounts of UPy. Furthermore, these stretchable networks with p ≤ 0.25 undergo self-healing upon repeated rupture and melt pressing at ≤100 °C while retaining similar tensile properties. In summary, decorating bottlebrush polymers with hydrogen bonds creates opportunities to independently manipulate associative network dynamics and mechanical moduli.

36 MATERIALS SCIENCE↗

Exploring Intentional Driving Volatility in Naturalistic Driving Environment Prior to Involvement in Unsafe Events

The sequence of instantaneous driving decisions and its variations prior to involvement in safety critical events, defined as event-based volatility, can be a leading indicator of safety. The research issue is characterizing volatility in instantaneous driving decisions in longitudinal and lateral directions, and how it varies across drivers involved in normal driving, crash, and near-crash events. A rigorous quasi-experimental study design is adopted to help compare driving behaviors in normal vs unsafe outcomes. Using a unique real-world naturalistic driving database from the SHRP 2, a test set of 9,593 driving events featuring 2.2 million temporal samples of real-world driving are analyzed. Twenty-four aggregate and segmented driving volatility measures based on acceleration and vehicular jerk are proposed, capturing variations in intentional and unintentional extreme instantaneous driving decisions. Given the possibility of unobserved heterogeneity/omitted variable bias, fixed- and random-parameter discrete choice models are developed that relate crash propensity to driving volatility and other factors. Statistically significant evidence is found that driver volatilities in near-crash and crash events are significantly greater than volatility in normal driving events. After controlling for traffic, roadway, and unobserved factors, the results suggest that greater intentional volatility increases the likelihood of both crash and near-crash events. Importantly, intentional volatility in longitudinal negative jerk has more negative consequences than intentional volatility in positive vehicular jerk. Compared to acceleration/deceleration, vehicular jerk can better characterize the volatility in microscopic driving decisions. The study demonstrates the value of big data analytics for understanding extreme driving behaviors in safe vs. unsafe driving outcomes.

Wali, Behram↗

Km‐Scale Simulations of Mesoscale Convective Systems Over South America—A Feature Tracker Intercomparison

Mesoscale convective systems (MCSs) are clusters of thunderstorms that are important in Earth's water and energy cycle. Additionally, they are responsible for extreme events such as large hail, strong winds, and extreme precipitation. Automated object-based analyses that track MCSs have become popular since they allow us to identify and follow MCSs over their entire life cycle in a Lagrangian framework. This rise in popularity was accompanied by an increasing number of MCS tracking algorithms, however, little is known about how sensitive analyses are concerning the MCS tracker formulation. Here, we assess differences between six MCS tracking algorithms on South American MCS characteristics and evaluate MCSs in kilometer-scale simulations with observational-based MCSs over 3 years. All trackers are run with a common set of MCS classification criteria to isolate tracker formulation differences. The tracker formulation substantially impacts MCS characteristics such as frequency, size, duration, and contribution to total precipitation. The evaluation of simulated MCS characteristics is less sensitive to the tracker formulation and all trackers agree that the model can capture MCS characteristics well across different South American climate zones. Dominant sources of uncertainty are the segmentation of cloud systems in space and time and the treatment of how MCSs are linked in time. Our results highlight that comparing MCS analyses that use different tracking algorithms is challenging. We provide general guidelines on how MCS characteristics compare between trackers to facilitate a more robust assessment of MCS statistics in future studies.

54 ENVIRONMENTAL SCIENCES↗

Tracking the Sun II: The Installed Cost of Photovoltaics in the U.S. from 1998-2008

Installations of solar photovoltaic (PV) systems have been growing at a rapid pace in recent years. In 2008, 5,948 MW of PV was installed globally, up from 2,826 MW in 2007, and was dominated by grid-connected applications. The United States was the world's third largest PV market in terms of annual capacity additions in 2008, behind Spain and Germany; 335 MW of PV was added in the U.S. in 2008, 293 MW of which came in the form of grid-connected installations. Despite the significant year-on-year growth, however, the share of global and U.S. electricity supply met with PV remains small, and annual PV additions are currently modest in the context of the overall electric system. The market for PV in the U.S. is driven by national, state, and local government incentives, including up-front cash rebates, production-based incentives, requirements that electricity suppliers purchase a certain amount of solar energy, and Federal and state tax benefits. These programs are, in part, motivated by the popular appeal of solar energy, and by the positive attributes of PV - modest environmental impacts, avoidance of fuel price risks, coincidence with peak electrical demand, and the location of PV at the point of use. Given the relatively high cost of PV, however, a key goal of these policies is to encourage cost reductions over time. Therefore, as policy incentives have become more significant and as PV deployment has accelerated, so too has the desire to track the installed cost of PV systems over time, by system characteristics, by system location, and by component. To address this need, Lawrence Berkeley National Laboratory initiated a report series focused on describing trends in the installed cost of grid-connected PV systems in the U.S. The present report, the second in the series, describes installed cost trends from 1998 through 2008. The analysis is based on project-level cost data from more than 52,000 residential and non-residential PV systems in the U.S., all of which are installed at end-use customer facilities (herein referred to as 'customer-sited' systems). The combined capacity of systems in the data sample totals 566 MW, equal to 71% of all grid-connected PV capacity installed in the U.S. through 2008, representing the most comprehensive source of installed PV cost data for the U.S.9 The report also briefly compares recent PV installed costs in the U.S. to those in Germany and Japan. Finally, it should be noted that the analysis presented here focuses on descriptive trends in the underlying data, and is primarily summarized in tabular and graphical form; later analysis may explore some of these trends with more-sophisticated statistical techniques. The report begins with a summary of the data collection methodology and resultant dataset (Section 2). The primary findings of the analysis are presented in Section 3, which describes trends in installed costs prior to receipt of any financial incentives: over time and by system size, component, state, customer segment (residential vs. commercial vs. public-sector vs. non-profit), application (new construction vs. retrofit), and technology type (building-integrated vs. rack-mounted, crystalline silicon vs. thin-film, and tracking vs. rack-mounted). Section 4 presents additional findings related to trends in PV incentive levels over time and among states (focusing specifically on state and utility incentive programs as well as state and Federal tax credits), and trends in the net installed cost paid by system owners after receipt of such incentives. Brief conclusions are offered in the final section.

14 SOLAR ENERGY↗

SU-C-BRA-02: Gradient Based Method of Target Delineation On PET/MR Image of Head and Neck Cancer Patients

Purpose: Validate the consistency of a gradient-based segmentation tool to facilitate accurate delineation of PET/CT-based GTVs in head and neck cancers by comparing against hybrid PET/MR-derived GTV contours. Materials and Methods: A total of 18 head and neck target volumes (10 primary and 8 nodal) were retrospectively contoured using a gradient-based segmentation tool by two observers. Each observer independently contoured each target five times. Inter-observer variability was evaluated via absolute percent differences. Intra-observer variability was examined by percentage uncertainty. All target volumes were also contoured using the SUV percent threshold method. The thresholds were explored case by case so its derived volume matched with the gradient-based volume. Dice similarity coefficients (DSC) were calculated to determine overlap of PET/CT GTVs and PET/MR GTVs. Results: The Levene’s test showed there was no statistically significant difference of the variances between the observer’s gradient-derived contours. However, the absolute difference between the observer’s volumes was 10.83%, with a range from 0.39% up to 42.89%. PET-avid regions with qualitatively non-uniform shapes and intensity levels had a higher absolute percent difference near 25%, while regions with uniform shapes and intensity levels had an absolute percent difference of 2% between observers. The average percentage uncertainty between observers was 4.83% and 7%. As the volume of the gradient-derived contours increased, the SUV threshold percent needed to match the volume decreased. Dice coefficients showed good agreement of the PET/CT and PET/MR GTVs with an average DSC value across all volumes at 0.69. Conclusion: Gradient-based segmentation of PET volume showed good consistency in general but can vary considerably for non-uniform target shapes and intensity levels. PET/CT-derived GTV contours stemming from the gradient-based tool show good agreement with the anatomically and metabolically more accurate PET/MR-derived GTV contours, but tumor delineation accuracy can be further improved with the use PET/MR.

60 APPLIED LIFE SCIENCES↗

Quantum model of electron accumulation at charged boundaries of heavily doped semiconductor films

A new quantum model of electron accumulation at positively charged boundaries of semiconductor films has been developed. It is based on the well-known concepts of quantum confinement of transverse electron motion in a uniform electric field, the role of which is played by the effective field of attraction to positive surface donor centers. Electrons with a surface density equal to the donor concentration occupy the corresponding quasi-discrete states according to the Fermi statistics. At reasonable concentrations all the electrons of the accumulation layer are mainly concentrated at the first quantum-confinement level. Ultra-high built-in fields on the order of the atomic level (10{sup 8} V/cm) correspond to the onset of filling the third level. The potential profile, which describes the interaction of the accumulation-layer electrons with other charged particles (including holes) is calculated by double integration of the Poisson equation with the electron density in the form of squares of the corresponding segments of the Airy function. Its boundary value-the surface potential-describes the effect of the electron-accumulation layer on the external electric circuit. The obtained dependence of the surface potential on the resulting boundary electric field (including that induced by the built-in charge) is easily transformed into the corresponding capacitance-voltage characteristics.

36 MATERIALS SCIENCE↗

GPS-aided Space Shuttle navigation

In the present paper, specific GPS (Global Positioning System) aided Shuttle navigation are presented as examples of the navigation performance prediction process. The process described is a statistical covariance error analysis. To facilitate detailing, the process is broken down into four portions with sharply limited interfaces. Considerations of mission scenarios form one distinct package of computer routines. Simulation of the onboard navigation filter is another facet of the process, as are the larger system covariance program and the GPS segment covariance simulation. The combination of these computer tools permits proper evaluation of the multitude of correlated error sources affecting GPS-aided Shuttle navigation.

Matchett, G.↗

Software and Algorithms for Biomedical Image Data Processing and Visualization

A new software equipped with novel image processing algorithms and graphical-user-interface (GUI) tools has been designed for automated analysis and processing of large amounts of biomedical image data. The software, called PlaqTrak, has been specifically used for analysis of plaque on teeth of patients. New algorithms have been developed and implemented to segment teeth of interest from surrounding gum, and a real-time image-based morphing procedure is used to automatically overlay a grid onto each segmented tooth. Pattern recognition methods are used to classify plaque from surrounding gum and enamel, while ignoring glare effects due to the reflection of camera light and ambient light from enamel regions. The PlaqTrak system integrates these components into a single software suite with an easy-to-use GUI (see Figure 1) that allows users to do an end-to-end run of a patient s record, including tooth segmentation of all teeth, grid morphing of each segmented tooth, and plaque classification of each tooth image. The automated and accurate processing of the captured images to segment each tooth [see Figure 2(a)] and then detect plaque on a tooth-by-tooth basis is a critical component of the PlaqTrak system to do clinical trials and analysis with minimal human intervention. These features offer distinct advantages over other competing systems that analyze groups of teeth or synthetic teeth. PlaqTrak divides each segmented tooth into eight regions using an advanced graphics morphing procedure [see results on a chipped tooth in Figure 2(b)], and a pattern recognition classifier is then used to locate plaque [red regions in Figure 2(d)] and enamel regions. The morphing allows analysis within regions of teeth, thereby facilitating detailed statistical analysis such as the amount of plaque present on the biting surfaces on teeth. This software system is applicable to a host of biomedical applications, such as cell analysis and life detection, or robotic applications, such as product inspection or assembly of parts in space and industry.

Talukder, Ashit↗

Analysis of Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption from 3-13 km Altitudes

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS space mission [1]. It uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1575 nm band, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver measures the energies of the laser echoes from the surface along with the range profile of scattering in the path. The column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off-line signals via the integrated path differential absorption (IPDA) technique. The time of flight of the laser pulses is used to estimate the height of the scattering surface and to reject laser photons scattered in the atmosphere. We developed an airborne lidar to demonstrate an early version of the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar stepped the pulsed laser's wavelength across the selected CO2 line with 20 wavelength steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a NIR photomultiplier and is recorded on every other reading by a photon counting system [2]. During August 2009 we made a series of 2.5 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over locations in the US, including the SGP ARM site in Oklahoma, central Illinois, north-eastern North Carolina, and over the Chesapeake Bay and the eastern shore of Virginia. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, and in-situ measurements were made using its CO2 sensor and radiosondes. We have conducted an analysis of the ranging and IPDA lidar measurements from these four flights. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We used a cross-correlation approach to process the laser echo records. This was used to estimate the range to the scattering surface, to define the edges of the laser pulses and to determine echo pulse energy at each wavelength. We used a minimum mean square approach to fit an instrument response function and to solve for the best-fit CO2 absorption line shape. We then calculated the differential optical depth (DOD) of the fitted CO2 line. We computed its statistics at the various altitude steps, and compare them to the DODs calculated from spectroscopy based on HITRAN 2008 and the column conditions calculated from the airborne in-situ readings. The results show the lidar and in-situ measurements have very similar DOD change with altitude and greater than 10 segments per flight where the scatter in the lidar measurements are less than or equal to 1ppm. We also present the results from subsequent CO2 column absorption measurements, which were made with stronger detected signals during three flights on the NASA DC-8 over the southwestern US in during July 2010.

Abshire, James B.↗

Classification Experiments on Real-World Texture

Many papers have been published concerning the analysis of visual texture and yet, very few application domains use texture for image classification. A possible reason for this low transfer of the technology is the lack of experience and testing in real-world imagery. In this paper, we assess the performance of texture-based classification methods on a number of real-world images relevant to autonomous navigation on cross-country terrain and to autonomous geology. Texture analysis will form part of the closed loop that allows a robotic system to navigate autonomously. We have implemented two different classifiers on features extracted by Gabor filter banks. The first classifier models feature distributions for each texture class using a mixture of Gaussians. Classification is performed using Maximum Likelihood. The second classifier represents local statistics using marginal histograms of the features over a region centered on the pixel to be classified. We measure system performance by comparison to ground truth image labels.

image segmentation↗

A new classification scheme of plastic wastes based upon recycling labels

Highlights: • PET, HPDE or PP types of plastics are considered. • An automated classification of plastic bottles based on the feature extraction and classification methods is performed. • The decision mechanism consists of PCA, Kernel PCA, FLDA, SVD and Laplacian Eigenmaps methods. • SVM is selected to achieve the classification task and majority voting technique is used. - Abstract: Since recycling of materials is widely assumed to be environmentally and economically beneficial, reliable sorting and processing of waste packaging materials such as plastics is very important for recycling with high efficiency. An automated system that can quickly categorize these materials is certainly needed for obtaining maximum classification while maintaining high throughput. In this paper, first of all, the photographs of the plastic bottles have been taken and several preprocessing steps were carried out. The first preprocessing step is to extract the plastic area of a bottle from the background. Then, the morphological image operations are implemented. These operations are edge detection, noise removal, hole removing, image enhancement, and image segmentation. These morphological operations can be generally defined in terms of the combinations of erosion and dilation. The effect of bottle color as well as label are eliminated using these operations. Secondly, the pixel-wise intensity values of the plastic bottle images have been used together with the most popular subspace and statistical feature extraction methods to construct the feature vectors in this study. Only three types of plastics are considered due to higher existence ratio of them than the other plastic types in the world. The decision mechanism consists of five different feature extraction methods including as Principal Component Analysis (PCA), Kernel PCA (KPCA), Fisher’s Linear Discriminant Analysis (FLDA), Singular Value Decomposition (SVD) and Laplacian Eigenmaps (LEMAP) and uses a simple experimental setup with a camera and homogenous backlighting. Due to the giving global solution for a classification problem, Support Vector Machine (SVM) is selected to achieve the classification task and majority voting technique is used as the decision mechanism. This technique equally weights each classification result and assigns the given plastic object to the class that the most classification results agree on. The proposed classification scheme provides high accuracy rate, and also it is able to run in real-time applications. It can automatically classify the plastic bottle types with approximately 90% recognition accuracy. Besides this, the proposed methodology yields approximately 96% classification rate for the separation of PET or non-PET plastic types. It also gives 92% accuracy for the categorization of non-PET plastic types into HPDE or PP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

STATISTICAL PROPERTIES OF SOLAR ACTIVE REGIONS OBTAINED FROM AN AUTOMATIC DETECTION SYSTEM AND THE COMPUTATIONAL BIASES

We have developed a computational software system to automate the process of identifying solar active regions (ARs) and quantifying their physical properties based on high-resolution synoptic magnetograms constructed from Michelson Doppler Imager (MDI; on board the SOHO spacecraft) images from 1996 to 2008. The system, based on morphological analysis and intensity thresholding, has four functional modules: (1) intensity segmentation to obtain kernel pixels, (2) a morphological opening operation to erase small kernels, which effectively remove ephemeral regions and magnetic fragments in decayed ARs, (3) region growing to extend kernels to full AR size, and (4) the morphological closing operation to merge/group regions with a small spatial gap. We calculate the basic physical parameters of the 1730 ARs identified by the auto system. The mean and maximum magnetic flux of individual ARs are 1.67 x 10{sup 22} Mx and 1.97 x 10{sup 23} Mx, while that per Carrington rotation are 1.83 x 10{sup 23} Mx and 6.96 x 10{sup 23} Mx, respectively. The frequency distributions of ARs with respect to both area size and magnetic flux follow a log-normal function. However, when we decrease the detection thresholds and thus increase the number of detected ARs, the frequency distribution largely follows a power-law function. We also find that the equatorward drifting motion of the AR bands with solar cycle can be described by a linear function superposed with intermittent reverse driftings. The average drifting speed over one solar cycle is 1{sup o}.83{+-}0{sup o}.04 yr{sup -1} or 0.708 {+-} 0.015 m s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Stent Retriever Thrombectomy in Different Thrombus Locations of Anterior Cerebral Circulation

BackgroundMechanical thrombectomy (MT) is a safe and efficient treatment for acute ischemic stroke in patients with proximal anterior occlusion and large penumbra. We evaluated the technical and clinical success of MT in relation to the location of the occlusion (internal carotid artery, M1 and M2 segments of the middle cerebral artery).MethodsWe prospectively reviewed 130 patients of whom 105 met the inclusion criteria. Baseline clinical, procedural and imaging variables, technical outcome (TICI, thrombolysis in cerebral infarction), 24 h imaging outcome and three-month clinical outcome (mRS, modified Rankin Scale) were recorded. Differences between the groups were studied with statistical tests according to the type of the variable.ResultsThere were 37, 46 and 22 patients in the internal carotid artery (ICA), M1 and M2 groups, respectively. TICI 2b or 3 was achieved in 92 cases (88 %) with a non-significant trend towards a better recanalization outcome in the ICA and M1 groups. Overall, 57 of the 105 patients (55 %) experienced favorable clinical outcome (mRS ≤ 2) with no significant differences between the groups. Excellent outcome (mRS ≤ 1) was seen in 40 patients (39 %) and there proportionally more patients with excellent outcome in the ICA and M1 groups (ICA: 44 %, M1: 41 %, M2: 23 % of patients, p = 0.22).ConclusionsThere were no statistically significant differences in the technical or clinical outcomes between the different sites of occlusion (ICA, M1 or M2). There was a non-significant trend towards achieving excellent clinical outcome (3-month mRS ≤ 1) more often and better recanalization results in the two more proximal locations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical and Clinical Outcomes Following Colonic Stenting: A Seven-Year Analysis of 268 Procedures

AimsTo assess the factors contributing to the technical and clinical success of colorectal stenting for large bowel obstruction.Methodology268 cases of colonic stenting for large bowel obstruction were performed in 249 patients of mean age of 72 years (28–98) between 2006 and 2013. The majority of strictures were due to malignant disease, 244/268 (91 %). Diverticular strictures accounted for 24/268 (9 %).ResultsOverall technical success rate was 81 % (217/268), with a clinical success rate of 65 % (174/268). Duration of symptoms ranged from 0 to 180 days (mean 8 days). Technical success rate was seen to decrease with increasing symptom duration. For symptom duration of less than 1 week, technical success was 85.4 % (181/212) versus 69.6 % (39/56) for those with symptoms of greater than a week (p < 0.05). Clinical success rates fell from 71.3 % (107/150) to 59.3 % (70/118) (p < 0.05) when attempting to stent lesions of greater than 5 cm. There was also a significant reduction in clinical success when stenting lesions on a bend rather than a straight segment of colon 75.7 % (109/144) versus 59.7 % (74/124) (p < 0.05). A total of 20 (7.46 %) perforations were identified during the study. Stent migration occurred in 6.6 % of cases. In-stent stenosis occurred in 3.3 %. The overall 30-day all cause mortality rate was 9 %.ConclusionLesion size, location and duration of obstructive symptoms are statistically significant determinants of patient outcome. These factors could be used to advise patient selection for colonic stenting or direct progression to surgical intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solar flare X-ray polarimeter utilizing a large area thin beryllium scattering disk

A model of a solar flare X-ray polarimeter utilizing a large-area thin beryllium scattering disk was developed using Monte Carlo techniques for several classes of solar flares. The solar-flare polarimeter consists of a 30-cm-diam Be disk of about 1/3 of a scattering length thickness, which is surrounded by a cylindrical detector composed of six segmented panels of NaI scintillators, each coupled to 15 photomultiplier tubes. The instrument is sensitive to X-rays from 10 to 100 keV. For a class-M-2 solar flare observed for 10 sec from a balloon at an altitude of 150,000 ft, the minimum detectable polarization at the 99 percent statistical confidence level was found to be 1-6 percent over the energy range 20-100 keV.

Gotthelf, E.↗

Focal Gray Matter Plasticity as a Function of Long Duration Head Down Tilted Bed Rest: Preliminary Results

Long duration spaceflight (i.e., 22 days or longer) has been associated with changes in sensorimotor systems, resulting in difficulties that astronauts experience with posture control, locomotion, and manual control. The microgravity environment is an important causal factor for spaceflight induced sensorimotor changes. Whether these sensorimotor changes are solely related to peripheral changes from reduced vestibular stimulation, body unloading, body fluid shifts or that they may be related to structural and functional brain changes is yet unknown. However, a recent study reported associations between microgravity and flattening of the posterior eye globe and protrusion of the optic nerve [1] possibly as the result of increased intracranial pressure due to microgravity induced bodily fluid shifts [3]. Moreover, elevated intracranial pressure has been related to white matter microstructural damage [2]. Thus, it is possible that spaceflight may affect brain structure and thereby cognitive functioning. Long duration head down tilt bed rest has been suggested as an exclusionary analog to study microgravity effects on the sensorimotor system [4]. Bed rest mimics microgravity in body unloading and bodily fluid shifts. In consideration of the health and performance of crewmembers both in- and post-flight, we are conducting a prospective longitudinal 70-day bed rest study as an analog to investigate the effects of microgravity on brain structure [5]. Here we present results of the first six subjects. Six subjects were assessed at 12 and 7 days before-, at 7, 30, and ~70 days in-, and at 8 and 12 days post 70 days of bed rest at the NASA bed rest facility in UTMB, Galveston, TX, USA. At each time point structural MRI scans (i.e., high resolution T1-weighted imaging and Diffusion Tensor Imaging (DTI)) were obtained using a 3T Siemens scanner. Focal changes over time in gray matter density were assessed using the voxel based morphometry 8 (VBM8) toolbox under SPM. Longitudinal processing in VBM8 includes linear registration of each scan to the mean of the subject and subsequently transforming all scans in to MNI space by applying the warp from the mean subject to MNI to the individual gray matter segmentations. Modulation was applied so that all images represented the volume of the original structure in native space. Voxel wise analysis was carried out on the gray matter images after smoothing, using a flexible factorial design with family wise error correction. Focal changes in white matter microstructural integrity were assessed using tract based spatial statistics (TBSS) as part of FMRIB software library (FSL). TBSS registers all DTI scans to standard space. It subsequently creates a study specific white matter skeleton of the major white matter tracts. For each subject, for each DTI metric (i.e. fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD)), the maximum value in a line perpendicular to the skeleton tract is projected to the skeleton. Non-parametric permutation based t-tests and ANOVA's were used for voxel-wise comparison of the skeletons. For both VBM and TBSS, comparison of pre bed rest measurements did not show significant differences. VBM analysis revealed decreased gray matter density in bilateral areas including the frontal medial cortex, the insular cortex and the caudate (see Figure) from 'pre to in bed rest'. Over the same time period, there was an increase in gray matter density in the cerebellum, occipital-, and parietal cortex, including the precuneus (see Figure). The majority of these changes did not recover from 'during to post bed rest'. TBSS analysis did not reveal significant changes in white matter microstructural integrity after correction for multiple comparisons. Uncorrected analyses (p<.015) revealed an increase in RD in the cerebellum and brainstem from pre bed rest to the first week in bed rest that did not recover post bed rest. Extended bed rest, which is an analog for microgravity, can result in gray matter changes and potentially in microstructural white matter changes in areas that are important for neuro motor behavior and cognition. These changes did not recover at two weeks post bed rest. Whether the effects of bed rest wear off at longer times post bed rest, and if they are associated with behavior are important questions that warrant further research.

Koppelmans, V.↗

A Dirichlet process mixture model for automatic {sup 18}F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions

Purpose: The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. Methods: The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracy was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10–37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. Results: Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a calibration curve was determined to automatically generate the optimal parameter from the variance of the ROI. This “calibration curve” was then applied to contour the whole data set. The accuracy (mean discrepancy between DPM model-based contours and reference contours) of volume estimation was below (1 ± 7)% on the whole data set (1 SD). The overlap between true and automatically segmented contours, measured by the Dice similarity coefficient, was 0.93 with a SD of 0.03. Conclusions: The proposed DPM model was able to accurately reproduce known volumes of FDG concentration, with high overlap between segmented and true volumes. For all the analyzed inserts of the IEC phantom, the algorithm proved to be robust to variations in radius and in TBR. The main advantage of this algorithm was that no setting of DPM parameters was required in advance, since the proper setting of the only parameter that could significantly influence the segmentation results was automatically related to the uptake variance of the chosen ROI. Furthermore, the algorithm did not need any preliminary choice of the optimum number of classes to describe the ROIs within PET images and no assumption about the shape of the lesion and the uptake heterogeneity of the tracer was required.

60 APPLIED LIFE SCIENCES↗