Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A User-Friendly GUI Tool for Automated Microstructural Analysis of Fiber-Reinforced Composites and Porous Structures

Understanding and quantifying microstructural features such as fiber orientation and porosity is critical for predicting the mechanical behavior and performance of fiber-reinforced polymer composites. Traditional manual analysis is time-consuming, subjective, and unsuitable for high-throughput datasets. We present a graphical user interface (GUI) application that automates the analysis of microscopy images to extract key microstructural metrics, including fiber orientation tensors, fiber orientation distribution, porosity and pore size distribution. The app integrates multiple image segmentation techniques including global and local thresholding, clustering, and region-based approaches, offering flexibility for different types of image qualities and features. Users can load microstructural images, select regions of interest and segmentation techniques tailored to their image dataset. It also addresses a critical challenge in fiber orientation analysis: the ambiguities caused by touching, overlapping, or partially cut fibers. It supports autorun examples for standardized workflows, enabling reproducible analysis and facilitating training and benchmarking. This tool significantly reduces manual intervention, enhances consistency, and accelerates data generation for structure–property modeling, process optimization, and digital materials research. The tool is intended for use by materials scientists, engineers, and researchers engaged in composite characterization, quality control, and machine learning-based microstructural studies.

Chawla, Komal [ORNL] (ORCID:0000000190327565)↗

Analog system for computing sparse codes

A parallel dynamical system for computing sparse representations of data, i.e., where the data can be fully represented in terms of a small number of non-zero code elements, and for reconstructing compressively sensed images. The system is based on the principles of thresholding and local competition that solves a family of sparse approximation problems corresponding to various sparsity metrics. The system utilizes Locally Competitive Algorithms (LCAs), nodes in a population continually compete with neighboring units using (usually one-way) lateral inhibition to calculate coefficients representing an input in an over complete dictionary.

Rozell, Christopher John↗

Variable loop gain using excessive regeneration for a delayed wide-area control system

Disclosed are methods and systems for adjusting a High Voltage Direct Current (HVDC) compensator output signal to an HVDC system to reduce control loop modulus due to excessive time delay of sensor measurements. Two different time windows, a Short-Time Variance Window (STVW) and an Extended-Time Variance Window (ETVW) may be examined for detection of increased energy. To detect increased energy the HVDC compensator output signal may be passed through a bandpass filter, then variances for the STVW and ETVW may be generated to produce corresponding test statistics. The STVW and ETVW test statistics may be compared to hypothesis test thresholds and have binary logic based on the hypothesis test comparisons used to generate a gain. The gain may then be multiplied times the original HVDC feedback compensator output such that the adjusted HVDC feedback compensator output reduces the control loop modulus when applied to the HVDC system.

Roberson, Dakota↗

Dominant balance-based adaptive mesh refinement for incompressible fluid flows

This work introduces a novel adaptive mesh refinement (AMR) method that utilizes dominant balance analysis (DBA) for efficient and accurate grid adaptation in computational fluid dynamics (CFD) simulations. The proposed method leverages a Gaussian mixture model (GMM) to classify grid cells into active and passive regions based on the dominant physical interactions within the equation space. By modeling truncation error probabilistically from discretized terms, the method identifies regions of high interaction where numerical accuracy is most sensitive to resolution. Unlike traditional AMR strategies, this approach does not rely on heuristic-based sensors or user-defined thresholds, providing a fully automated and problem-independent framework for AMR. Applied to the incompressible Navier-Stokes equations for steady and unsteady flow past a cylinder, the DBA-based AMR method achieves comparable accuracy to high-resolution grids while reducing computational costs by up to 70 %. The validation highlights the method’s effectiveness in capturing complex flow features while minimizing grid cells, directing computational resources toward regions with the most critical dynamics. This modular and scalable strategy is adaptable to a wide range of applications, presenting a promising tool for efficient high-fidelity simulations in CFD and other multiphysics domains.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of InSpector{sup TM} 1 1000 Instrument with LaBr{sub 3} for Nuclear Criticality Safety (NCS) Applications at the Westinghouse Hematite Decommissioning Project (HDP) - 13132

The Westinghouse Hematite Decommissioning Project (HDP) is a former nuclear fuel cycle facility that is currently undergoing decommissioning. One aspect of the decommissioning scope is remediation of buried nuclear waste in unlined burial pits. The current Nuclear Criticality Safety program relies on application of criticality controls based on radiological setpoints from a 2 x 2 Sodium Iodide (NaI) detector. Because of the nature of the material buried (Low Enriched Uranium (LEU), depleted uranium, thorium, and radium) and the stringent threshold for application of criticality controls based on waste management (0.1 g {sup 235}U/L), a better method for {sup 235}U identification and quantification has been developed. This paper outlines the early stages of a quick, in-field nuclear material assay and {sup 235}U mass estimation process currently being deployed at HDP. Nuclear material initially classified such that NCS controls are necessary can be demonstrated not to require such controls and dispositioned as desired by project operations. Using Monte Carlo techniques and a high resolution Lanthanum Bromide (LaBr) detector with portable Multi-Channel Analyzer (MCA), a bounding {sup 235}U mass is assigned to basic geometries of nuclear material as it is excavated. The deployment of these methods and techniques has saved large amounts of time and money in the nuclear material remediation process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prevalence of Self-Reported Voice Concerns and Associated Risk Markers in a Nonclinical Sample of Military Service Members

Introduction: Difficult communication environments are common in military settings, and effective voice use can be critical to mission success. This study aimed to estimate the prevalence of self-reported voice disorders among U.S. military service members and to identify factors that contribute to their voice concerns. Method: A nonclinical sample of 4,123 active-duty service members was recruited across Department of Defense hearing conservation clinics. During their required annual hearing evaluation, volunteers provided responses to voice-related questions including a slightly adapted version of the Voice Handicap Index-10 (VHI-10) as part of a larger survey about communication issues. Changepoint detection was applied to age and years of service to explore cohort effects in the reporting of voice concerns. Logistic regression analyses examined multiple available factors related to communication to identify factors associated with abnormal results on the VHI-10. Results: Among the respondents, 41% reported experiencing vocal hoarseness or fatigue at least several times per year, and 8.2% ( n = 336) scored above the recommended abnormal cut-point value of 11 on the VHI-10. Factors independently associated with the greatest risk for self-reported voice concerns were sex (female), cadmium exposure, vocal demands (the need for a strong, clear voice), and auditory health measures (frequency of experiencing temporary threshold shifts; self-reported hearing difficulties). Conclusions: Based on self-reported voice concerns and false negative rates reported in the literature, the prevalence of dysphonia in a large sample of active-duty service members is estimated to be 11.7%, which is higher than that in the general population. Certain predictors for voice concerns were expected based on previous literature, like female sex and voice use, but frequency of temporary threshold shifts and exposure to cadmium were surprising. The strong link between voice and auditory problems has particular implications regarding the need for effective communication in high-noise military and other occupational environments.

Audiology & Speech-Language Pathology↗

Subcritical turbulence spreading and avalanche birth

In confined plasmas, a localized fluctuation in a marginal or weakly damped region will propagate and generate an avalanche if it exceeds a threshold. In this letter, a new model for turbulence spreading based on subcritical instability in the turbulence intensity is introduced. We derive a quantitative threshold for spreading from a seed in a stable region, based on a competition between diffusion and nonlinear growth of the turbulence intensity. The model resolves issues with the established Fisher equation model for turbulence spreading, which is supercritical and cannot support the stationary coexistence of multiple turbulence levels. Implications for turbulence spreading are discussed, including the dynamics of ballistic penetration of turbulence into the stable zone. Finally, tests of the theory are suggested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the signal-to-noise ratio for laser ranging by adjusting the photon equivalent threshold of a multi-pixel photon counter

A photon equivalent (PE) threshold-adjusting regime for laser ranging is proposed based on a multi-pixel photon counter (MPPC), and the mechanism of PE threshold influence on the signal-to-noise ratio (SNR) is demonstrated and analysed. The unique PE threshold adjustability of an MPPC leads to interesting results for laser ranging. Experimental results show that the SNR of the laser ranging system is significantly improved by optimising the MPPC PE threshold, which is beneficial for detection and false alarm probabilities. Submillimeter laser ranging resolution is obtained with noncooperative targets placed several meters away. Nanosecond dead time single photon laser ranging without gating is obtained due to an MPPC with a small pixel area. Multiple target ranging is implemented with a single MPPC rather than an array. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of advanced automatic PET segmentation methods using nonspherical thin-wall inserts

Purpose: The use of positron emission tomography (PET) within radiotherapy treatment planning requires the availability of reliable and accurate segmentation tools. PET automatic segmentation (PET-AS) methods have been recommended for the delineation of tumors, but there is still a lack of thorough validation and cross-comparison of such methods using clinically relevant data. In particular, studies validating PET segmentation tools mainly use phantoms with thick plastic walls inserts of simple spherical geometry and have not specifically investigated the effect of the target object geometry on the delineation accuracy. Our work therefore aimed at generating clinically realistic data using nonspherical thin-wall plastic inserts, for the evaluation and comparison of a set of eight promising PET-AS approaches. Methods: Sixteen nonspherical inserts were manufactured with a plastic wall of 0.18 mm and scanned within a custom plastic phantom. These included ellipsoids and toroids derived with different volumes, as well as tubes, pear- and drop-shaped inserts with different aspect ratios. A set of six spheres of volumes ranging from 0.5 to 102 ml was used for a baseline study. A selection of eight PET-AS methods, written in house, was applied to the images obtained. The methods represented promising segmentation approaches such as adaptive iterative thresholding, region-growing, clustering and gradient-based schemes. The delineation accuracy was measured in terms of overlap with the computed tomography reference contour, using the dice similarity coefficient (DSC), and error in dimensions. Results: The delineation accuracy was lower for nonspherical inserts than for spheres of the same volume in 88% cases. Slice-by-slice gradient-based methods, showed particularly lower DSC for tori (DSC < 0.5), caused by a failure to recover the object geometry. The region-growing method reached high levels of accuracy for most inserts (DSC > 0.76 except for tori) but showed the largest errors in the recovery of pears and drops dimensions (higher than 10% and 30% of the true length, respectively). Large errors were visible for one of the gradient-based contouring methods when delineating drop-shaped inserts. Low DSC due to systematic underestimation of the volumes was observed for our fuzzy clustering method when using nonspherical inserts. The adaptive iterative thresholding method produced the highest DSC score on our nonspherical dataset (DSC > 0.83, except for tori) and showed robustness to the insert geometry. Conclusions: This study investigated the accuracy of eight PET-AS methods for the delineation of objects with a range of nonspherical geometries. The authors’ results confirmed the robustness of some segmentation approaches, but also showed the weaknesses of some of the other methods implemented, which were not observed with spherical inserts. This work therefore highlights the importance of using a variety of thin-wall inserts with complex geometries for the validation of PET-AS methods and provided useful information for further development of the methods tested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans

Purpose: The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. Methods: The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Results: Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference in the performance of any device between gamma criteria of 2%/2 mm, 3%/3 mm, and 5%/3 mm. Finally, optimal cutoffs (e.g., percent of pixels passing gamma) were determined for each device and while clinical practice commonly uses a threshold of 90% of pixels passing for most cases, these results showed variability in the optimal cutoff among devices. Conclusions: IMRT QA devices have differences in their ability to accurately detect dosimetrically acceptable and unacceptable plans. Field-by-field analysis with a MapCheck device and use of the MapCheck with a MapPhan phantom while delivering at planned rotational gantry angles resulted in a significantly poorer ability to accurately sort acceptable and unacceptable plans compared with the other techniques examined. Patient-specific IMRT QA techniques in general should be thoroughly evaluated for their ability to correctly differentiate acceptable and unacceptable plans. Additionally, optimal agreement thresholds should be identified and used as common clinical thresholds typically worked very poorly to identify unacceptable plans.

60 APPLIED LIFE SCIENCES↗

Interfacial oxide and other species in trimethylaluminum-pretreated atomic layer deposition-Al 2 O 3 /GaN characterized by sputter-assisted ToF-SIMS

Deposition techniques, like atomic layer deposition (ALD), are used to form high-quality dielectrics for GaN-based metal–oxide–semiconductor (MOS) gate structures due to the lack of a reliable thermal oxide in GaN. Moreover, interfacial GaO x from pre-existing native oxides is thought to adversely impact channel carrier dynamics and induce undesired threshold voltage shifts in GaN-based MOS gate structures. Exposure of the GaN surface to the trimethylaluminum (TMA) precursor prior to standard alumina ALD decreases the native oxide layer on GaN, but the extent of chemical modification has not been well studied in the context of interface composition in a MOS gate structure. Herein, we compare annealed 55 nm Al 2 O 3 dielectric films on GaN grown using either a water-first ALD process or a process including sequential pulses of TMA immediately before the initiation of Al 2 O 3 ALD. Time-of-Flight Secondary Ion Mass Spectrometry measures differences in the interfacial GaO x content between each ALD film. Here, it also detects surface contaminant species like Si, F, S, and C. Furthermore, we report the formation of an AlN species at the Al 2 O 3 /GaN interface, which is more prominent for the film grown using the TMA pre-pulse step. In general, this work demonstrates that the TMA pre-pulse step is an effective strategy for cleaning substrate surfaces prior to ALD.

Atomic layer deposition↗

Assessment of Tumor Volumes in Skull Base Glomus Tumors Using Gluc-Lys[{sup 18}F]-TOCA Positron Emission Tomography

Purpose: To assess a threshold for Gluc-Lys[{sup 18}F]-TOCA positron emission tomography (PET) in target volume delineation of glomus tumors in the skull base and to compare with MRI-based target volume delineation. Methods and Materials: The threshold for volume segmentation in the PET images was determined by a phantom study. Nine patients with a total of 11 glomus tumors underwent PET either with Gluc-Lys[{sup 18}F]-TOCA or with {sup 68}Ga-DOTATOC (in 1 case). All patients were additionally scanned by MRI. Positron emission tomography and MR images were transferred to a treatment-planning system; MR images were analyzed for lesion volume by two observers, and PET images were analyzed by a semiautomated thresholding algorithm. Results: Our phantom study revealed that 32% of the maximum standardized uptake value is an appropriate threshold for tumor segmentation in PET-based target volume delineation of gross tumors. Target volume delineation by MRI was characterized by high interobserver variability. In contrast, interobserver variability was minimal if fused PET/MRI images were used. The gross tumor volumes (GTVs) determined by PET (GTV-PET) showed a statistically significant correlation with the GTVs determined by MRI (GTV-MRI) in primary tumors; in recurrent tumors higher differences were found. The mean GTV-MRI was significantly higher than mean GTV-PET. The increase added by MRI to the common volume was due to scar tissue with strong signal enhancement on MRI. Conclusions: In patients with glomus tumors, Gluc-Lys[{sup 18}F]-TOCA PET helps to reduce interobserver variability if an appropriate threshold for tumor segmentation has been determined for institutional conditions. Especially in patients with recurrent tumors after surgery, Gluc-Lys[{sup 18}F]-TOCA PET improves the accuracy of GTV delineation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Renewable Fuel Standard May Limit Overall Greenhouse Gas Savings by Corn Stover-Based Cellulosic Biofuels in the U.S. Midwest: Effects of the Regulatory Approach on Projected Emissions

The Renewable Fuel Standard (RFS) program specifies a greenhouse gas (GHG) reduction threshold for cellulosic biofuels, while the Low Carbon Fuel Standard (LCFS) program in California does not. Here, we investigate the effects of the GHG threshold under the RFS on projected GHG savings from two corn stover-based biofuel supply chain systems in the United States Midwest. The analysis is based on a techno-economic framework that minimizes ethanol selling price. The GHG threshold lowers the lifecycle GHG of ethanol: 34.39 +/- 4.92 gCO(2) MJ(-1) in the RFS-compliant system and 46.30 +/- 10.05 gCO(2) MJ1 in the non RFS-compliant system. However, hypothetical biorefinery systems complying with the RFS will not process the more GHG-intensive corn stover, and thus much less biofuel will be produced compared to the non RFS-compliant system. Thus, taken as a whole, the non RFS-compliant system would achieve more GHG savings than an RFS-compliant system: 10.7 TgCO(2) year(-1) in the non RFS-compliant system compared with 4.4 TgCO(2) year1 in the RFS-compliant system. These results suggest that the current RFS GHG reduction threshold may not be the most efficient way to carry out the purposes of the Energy Security and Independence Act in the corn stover-based biofuel system: relaxing the threshold could actually increase the overall GHG savings from corn stover-based biofuels. Therefore, the LCFS-type regulatory approach is recommended for the corn stover-based cellulosic biofuel system under the RFS program. In addition, our calculation of the GHG balance for stover-based biofuel accounts for SOC losses, while the current RFS estimates do not include effects on SOC.

CARBON, BIOMASS, VOLUME↗

Lead-chalcogenide mid-infrared vertical external cavity surface emitting lasers with improved threshold: Theory and experiment

Mid-infrared Vertical External Cavity Surface Emitting Lasers (VECSEL) based on narrow gap lead-chalcogenide (IV-VI) semiconductors exhibit strongly reduced threshold powers if the active layers are structured laterally for improved optical confinement. This is predicted by 3-d optical calculations; they show that lateral optical confinement is needed to counteract the anti-guiding features of IV-VIs due to their negative temperature dependence of the refractive index. An experimental proof is performed with PbSe quantum well based VECSEL grown on a Si-substrate by molecular beam epitaxy and emitting around 3.3 μm. With proper mesa-etching, the threshold intensity is about 8-times reduced.

36 MATERIALS SCIENCE↗

2005 ACGIH Lifting TLV: Employee-Friendly Presentation and Guidance for Professional Judgment

The American Council of Governmental Industrial Hygienists (ACGIH) Lifting Threshold Limit Values (TLVs) provide a tool to reduce incidence of low back and shoulder injuries. However, application of the TLV is too complicated for floor-level workers and relies on professional judgment to assess commonly encountered tasks. This paper presents an Employee-Friendly Simplified Format of the TLV that has been adapted from Table 1 of the Lifting TLV presented in the 2005 TLVs and BEIs Based on the Documentation of the Threshold Limit Values for Chemical Substances and Physical Agents & Biological Exposure Indices. This simplified format can be employed by floor-level workers to self-assess lifting tasks. The Ergonomics Project Team also provides research-based guidance for applying professional judgment consistent with standard industry practice: Extended Work Shifts – Reduce weight by 20% for shifts lasting 8 to 12 hours; Constrained Lower Body Posture – Reduce weight by 25% when lifting in such postures; Infrequently Performed Lifts – Lift up to 15 lbs. ≤3 lifts per hour within the zones marked “No safe limit for repetitive lifting” in the TLVs Table 1; Asymmetry beyond 30° – Reduce weight by 10 lbs. for lifts with up to 60° asymmetry from sagittal plane.

60 APPLIED LIFE SCIENCES↗

A fully 3D atomistic quantum mechanical study on random dopant induced effects in 25nm MOSFETs

We present a fully 3D atomistic quantum mechanical simulation for nanometered MOSFET using a coupled Schroedinger equation and Poisson equation approach. Empirical pseudopotential is used to represent the single particle Hamiltonian and linear combination of bulk band (LCBB) method is used to solve the million atom Schroedinger's equation. We studied gate threshold fluctuations and threshold lowering due to the discrete dopant configurations. We compared our results with semiclassical simulation results. We found quantum mechanical effects increase the threshold fluctuation while decreases the threshold lowering. The increase of threshold fluctuation is in agreement with previous study based on approximated density gradient approach to represent the quantum mechanical effect. However, the decrease in threshold lowering is in contrast with the previous density gradient calculations.

36 MATERIALS SCIENCE↗

Scattering assisted injection based injectorless mid infrared quantum cascade laser

An injectorless five-well mid infrared quantum cascade laser is analyzed which relies on phonon scattering injection in contrast to resonant tunneling injection, which has been previously used for injectorless designs. A Monte Carlo based self-consistent electron and photon transport simulator is used to analyze the performance of the analyzed design and compare it to existing injectorless designs. The simulation results show that the analyzed design could greatly enhance the optical gain and the characteristic temperatures of injectorless quantum cascade lasers (QCLs) which have typically been hindered by low characteristic temperatures and significant temperature related performance degradation. Simulations of the analyzed device predict threshold current densities of 0.85 kA/cm{sup 2} and 1.95 kA/cm{sup 2} at 77 K and 300 K, respectively, which are comparable to the threshold current densities of conventional injector based QCLs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonance Suppression based on Predictive Control of Grid-following Inverters with LCL Filter in Weak Grid Condition

This paper presents an effective resonance suppression control when grid interactive inverter with LCL filter experience weak grid conditions. The resonance suppression mechanism is based on finite-set model predictive control (FSMPC) with adaptive cost function to alter the controller objectives seamlessly. The large parasitic impedance and low short circuit ratio (SCR) of weak grid challenges the operation of gridconnected inverters. Specifically, the LCL filter resonance may get excited, resulting in collapse of the inverter operation. To address this issue, an effective active damping approach is implemented in the proposed control. In the proposed active damping scheme for resonance suppression, the feedback currents are switched based on the operating conditions of inverter. During the stiff grid conditions, grid current serves as feedback to the controller. While in the weak grid conditions, the inverter current is selected as feedback signal. The toggling action between these two feedback currents is determined by comparing moving RMS of grid current with threshold current as constraint in the cost function of the proposed MPC scheme. The threshold current for toggling action is based on the reference active and reactive power setpoints plus an acceptable band of variation. The theoretical analysis is verified by several case studies.

Umar, Muhammad Farooq↗