Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Theoretical study of time-resolved luminescence in semiconductors. I. Decay from the steady state

Time-resolved luminescence (TRL) is a non-destructive, non-invasive, and contactless characterization method. We studied TRL decay on semiconductor layers and thin film homostructures after a steady state illumination by simulation with Synopsys TCAD{sup ®} and by analytical approximate solution of the appropriate equations. First, we show that the luminescence decay time in general equals the minority carrier lifetime only for a homogeneous and time-independent carrier lifetime. Then, we investigate the influence of photon recycling, injection level, charge carrier diffusion, defects in the bulk and at the surfaces, as well as space charge on the TRL decay separately by quasi one-dimensional simulations of semiconductor layers and semiconductor homostructures. We further study the influence of sample non-homogeneity as may be found in polycrystalline semiconductors. We show how carrier lifetime can be extracted from the TRL transients and how the samples can be characterized by excitation dependent measurements in the open circuit case. We can explain some effects found in luminescence experiments, like a decrease of the decay time with an increasing excitation, a maximum in the decay time due to saturated bulk-defects and curved luminescence transients due to high injections or sample inhomogeneities. Furthermore, we are focussing on the question, how single layers within a semiconductor stack can be characterized.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT

Purpose: In x-ray computed tomography (CT), a violation of the Tuy data sufficiency condition leads to limited-view artifacts. In some applications, it is desirable to use data corresponding to a narrow temporal window to reconstruct images with reduced temporal-average artifacts. However, the need to reduce temporal-average artifacts in practice may result in a violation of the Tuy condition and thus undesirable limited-view artifacts. In this paper, the authors present a new iterative reconstruction method, synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON), to eliminate limited-view artifacts using data acquired within an ultranarrow temporal window that severely violates the Tuy condition. Methods: In time-resolved contrast enhanced CT acquisitions, image contrast dynamically changes during data acquisition. Each image reconstructed from data acquired in a given temporal window represents one time frame and can be denoted as an image vector. Conventionally, each individual time frame is reconstructed independently. In this paper, all image frames are grouped into a spatial–temporal image matrix and are reconstructed together. Rather than the spatial and/or temporal smoothing regularizers commonly used in iterative image reconstruction, the nuclear norm of the spatial–temporal image matrix is used in SMART-RECON to regularize the reconstruction of all image time frames. This regularizer exploits the low-dimensional structure of the spatial–temporal image matrix to mitigate limited-view artifacts when an ultranarrow temporal window is desired in some applications to reduce temporal-average artifacts. Both numerical simulations in two dimensional image slices with known ground truth and in vivo human subject data acquired in a contrast enhanced cone beam CT exam have been used to validate the proposed SMART-RECON algorithm and to demonstrate the initial performance of the algorithm. Reconstruction errors and temporal fidelity of the reconstructed images were quantified using the relative root mean square error (rRMSE) and the universal quality index (UQI) in numerical simulations. The performance of the SMART-RECON algorithm was compared with that of the prior image constrained compressed sensing (PICCS) reconstruction quantitatively in simulations and qualitatively in human subject exam. Results: In numerical simulations, the 240{sup ∘} short scan angular span was divided into four consecutive 60{sup ∘} angular subsectors. SMART-RECON enables four high temporal fidelity images without limited-view artifacts. The average rRMSE is 16% and UQIs are 0.96 and 0.95 for the two local regions of interest, respectively. In contrast, the corresponding average rRMSE and UQIs are 25%, 0.78, and 0.81, respectively, for the PICCS reconstruction. Note that only one filtered backprojection image can be reconstructed from the same data set with an average rRMSE and UQIs are 45%, 0.71, and 0.79, respectively, to benchmark reconstruction accuracies. For in vivo contrast enhanced cone beam CT data acquired from a short scan angular span of 200{sup ∘}, three 66{sup ∘} angular subsectors were used in SMART-RECON. The results demonstrated clear contrast difference in three SMART-RECON reconstructed image volumes without limited-view artifacts. In contrast, for the same angular sectors, PICCS cannot reconstruct images without limited-view artifacts and with clear contrast difference in three reconstructed image volumes. Conclusions: In time-resolved CT, the proposed SMART-RECON method provides a new method to eliminate limited-view artifacts using data acquired in an ultranarrow temporal window, which corresponds to approximately 60{sup ∘} angular subsectors.

60 APPLIED LIFE SCIENCES↗

Dynamics of Quaternary Structure Transitions in R-State Carbonmonoxyhemoglobin Unveiled in Time-Resolved X-ray Scattering Patterns Following a Temperature Jump

It is well-known that tetrameric hemoglobin binds ligands cooperatively by undergoing a ligand-induced T → R quaternary structure transition, a structure-function relationship that has long served as a model system for understanding allostery in proteins. However, kinetic studies of the reverse, R → T quaternary structure transition following photolysis of carbonmonoxyhemoglobin (HbCO) reveal complex behavior that may be better explained by the presence of two different R quaternary structures coexisting in thermal equilibrium. Indeed, we report here time-resolved small- and wide-angle X-ray scattering (SAXS/WAXS) patterns of HbCO following a temperature jump that not only provide unambiguous evidence for more than one R state, but also unveil the time scale for interconversion between them. Since the time scale for the photolysis-induced R → T transition is likely different for different R-states, this structural heterogeneity must be accounted for to properly explain the kinetic heterogeneity observed in time-resolved spectroscopic studies following photolysis of HbCO.

Cho, Hyun Sun↗

Tracking surface photovoltage dipole geometry in Bi 2 Se 3 with time-resolved photoemission

Topological insulators have been shown to exhibit strong and long-lived surface photovoltages when excited by an infrared pump. The ability to generate long-lived potentials on these surfaces provides opportunities to manipulate the spin-momentum locked topological surface states. Moreover, the photo-induced nature of this effect allows for localized excitation of arbitrary geometries. Knowing precisely how these potentials form and evolve is critical in understanding how to manage the effect in applications. The uniqueness of the photoemission experimental geometry, in which the photoelectron must traverse the induced surface field in vacuum, provides an interesting probe of the electric dipole shape generated by the surface photovoltage. In this study, we are able to match the observed decay of the geometric effect on the photoelectron to an essential electrodynamics model of the light-induced dipole thereby tracking the fluence-dependent evolution of the dipole geometry. Finally, by utilizing a standard time-resolved angle-resolved photoemission experiment, we are able to determine real-space information of the dipole while simultaneously recovering time-resolved band structure.

42 ENGINEERING↗

Diverse simulations of time-resolved photoluminescence in thin-film solar cells: A SnO 2 /CdSe y Te 1-y case study

Time-resolved photoluminescence (TRPL) is widely used to measure carrier lifetime in thin-film solar cell absorbers. However, the injection dependence of data and frequent non-exponential decay shapes complicate the interpretation. Here, we develop a numerical model to simulate injection-dependent TRPL measurements in a SnO 2 /CdSe y Te 1-y case study solar cell structure, considering parameters of interest to researchers in industry and academia. Previous simulations have shown that, in low injection, excess electrons and holes injected by the laser pulse are rapidly separated in the electric field formed by the pn junction. As a result, at early times, the PL signal can decay faster than the Shockley-Read-Hall lifetime in the absorber bulk (t_bulk). Prior simulations have shown that the charge stored in the junction can slowly leak out to affect decays at late times. However, it has not been clear if and to what degree charge storage can affect the slopes extracted from TRPL decays - t_2 - commonly cited as the TRPL-measured lifetime. Here, we show that charge storage can, in some cases, result in t_2 values that substantially overestimate t_bulk. Previous simulations indicate that high injection conditions can screen the junction field and minimize charge separation. Here, we show that continued injection increases can drive down t_2 below t_bulk as radiative recombination becomes dominant. We catalog charge storage and radiative recombination impacts for a diverse set of material parameters and compare results to double-heterostructure models.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,S↗

Time resolved magneto-optical studies of ferromagnetic InMnSb films

We report time resolved magneto-optical measurements in InMnSb ferromagnetic films with 2% and 2.8% Mn contents grown by low temperature molecular beam epitaxy. In order to probe a possible interaction between the spins of photoexcited carriers and the Mn ions, we measured spin dynamics before and after aligning the Mn ions by applying an external magnetic field at temperatures above and below the samples' Curie temperatures. We observed no significant temperature or magnetic field dependence in the relaxation times and attribute the observed dynamics entirely to the relaxation of photoexcited electrons in the conduction band where the s-d coupling with the localized Mn ions is significantly weaker compared to the p-d exchange coupling. We observed several differences in the optical response of our InMnSb samples which could have been influenced mainly by the samples' growth conditions.

36 MATERIALS SCIENCE↗

A Seeman–Bohlin geometry for high-resolution nanosecond x-ray diffraction measurements from shocked polycrystalline and amorphous materials [Shock compression measurement in a Seeman-Bohlin camera geometry developed for time-resolved x-ray diffraction studies of shocked polycrystalline and amorphous materials]

Here, we report on a focusing x-ray diffraction geometry capable of high-resolution in situ lattice probing from dynamically loaded polycrystalline and amorphous materials. The Seeman–Bohlin-type camera presented here is ideally suited for time-resolved x-ray diffraction measurements performed on high energy multibeam laser platforms. Diffraction from several lattice planes of ablatively shock-loaded 25 μm thick Cu foils was recorded on a focusing circle of diameter D=100 mm with exceptional angular resolution limited only by the spectral broadening of the x-ray source. Excellent agreement was found between the density measured using x-ray diffraction and that inferred from Doppler velocimetry and the known shock Hugoniot of Cu. In addition, x-ray diffraction signal was captured from an amorphous material under static conditions.

36 MATERIALS SCIENCE↗

Determination of mineral dissolution regimes using flow-through time-resolved analysis (FT-TRA) and numerical simulation

Flow-through time resolved analysis (FT-TRA) involves subjecting small mineral samples (< 10 mg) inserted in a miniature flow-through cell (50 μL) to controlled flows of eluent analyzed on-line by ICP-MS. In this study, FT-TRA is used to empirically determine the dissolution regimes for the two well-studied minerals forsterite and calcite, representing minerals with relatively slow and fast dissolution kinetics. A proportional increase in steady-state effluent [Mg, Si] concentrations with increasing flow-through cell eluent residence times confirms a dominantly surface-controlled dissolution regime for a powdered forsterite sample at pH 2.3, implying that transport limitations are negligible. In contrast, the relationship between flow rates and dissolution rates for single grain calcite samples at pH 2.3-4 reveals that transport limitations affect the rate of calcite dissolution. In order to provide a quantitative and process-based assessment of the effect of diffusive transport limitations, simulations of the calcite experiments were performed with a high resolution, pore-scale model that considers the geometry of the calcite grain and the FT-TRA flow-through reactor. The pore-scale model reproduces the observed effluent [Ca] concentrations for all experimental conditions using a single set of surface kinetic parameters, by accounting for the formation of a diffusive boundary layer (DBL) that varies in thickness as a function of flow rates. These results demonstrate that combining FT-TRA with pore-scale modeling makes it possible to obtain unprecedented insights not achievable by either method separately, including quantification of DBL thicknesses and the determination of transport controls as a function of pH, flow velocity and residence times.

58 GEOSCIENCES↗

Dodecane Radiolysis Yields by Time-Resolved and Steady-State Methods

Liquid organic molecules are present as solvents, complexing ligands, and additives in both used nuclear fuel reprocessing solvent systems and in their subsequent nuclear waste streams. Under these extreme environments, these organic molecules are constantly exposed to ionizing radiation which promotes their radiolysis, forming a variety of short-lived, highly energetic, excited state and radical species.1-4 Here, we demonstrate new experimental results for the steady-state and time-resolved irradiations of dodecane (C12H26), a long chain, liquid, aliphatic hydrocarbon that is the prototypical solvent used for benchtop studies of aqueous-organic solvent extraction systems. When ionizing radiation interacts with neat dodecane, the energy transfer can result in molecular ionization, to give the dodecane radical cation (C12H26+•) and the solvated electron (eS–), and molecular electronic excitation (C12H26*), which rapidly produces transient carbon-centered radical fragments (CxHy•) and hydrogen atoms (H•).1-4 Studies on the initial yields of the ionization and excitation products were performed using time-resolved picosecond electron pulse radiolysis with the use of molecular probes. Using steady-state cobalt-60 gamma irradiations, the suite of products formed by dodecane radiolysis in aerated and deaerated solutions was determined. Then, using iodine as an alkyl radical scavenger, the loss of molecular iodine with dose was quantified, and by correlating with the molecular hydrogen yields of the system, the initial yields of the various carbon-centered radicals were also determined. Finally, the rates of reactions of the C12H26+• and eS– with ligands proposed for use in spent nuclear fuel reprocessing were studied as a function of temperature from 10 – 40 °C.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Nanoscale imaging of quantum dot dimers using time-resolved super-resolution microscopy combined with scanning electron microscopy

Abstract Time-resolved super-resolution microscopy was used in conjunction with scanning electron microscopy to image individual colloidal CdSe/CdS semiconductor quantum dots (QD) and QD dimers. The photoluminescence (PL) lifetimes, intensities, and structural parameters were acquired with nanometer scale spatial resolution and sub-nanosecond time resolution. The combination of these two techniques was more powerful than either alone, enabling us to resolve the PL properties of individual QDs within QD dimers as they blinked on and off, measure interparticle distances, and identify QDs that may be participating in energy transfer. The localization precision of our optical imaging technique was ∼3 nm, low enough that the emission from individual QDs within the dimers could be spatially resolved. While the majority of QDs within dimers acted as independent emitters, at least one pair of QDs in our study exhibited lifetime and intensity behaviors consistent with resonance energy transfer from a shorter lifetime and lower intensity donor QD to a longer lifetime and higher intensity acceptor QD. For this case, we demonstrate how the combined super-resolution optical imaging and scanning electron microscopy data can be used to characterize the energy transfer rate.

36 MATERIALS SCIENCE↗

Time-resolved in situ Studies of Apatite Formation in Aqueous Solutions

Formation of hydroxylapatite through the precipitation and evolution of calcium phosphate precursor phases under varying conditions of temperature (25-90 C), pH (6.5-9.0), and calcium to phosphorus ratio (1.0, 1.33, 1.5, and 1.67) comparable to those found in many sediments and soils were studied. The products of low-temperature precipitation were analyzed by ex situ X-ray diffraction and SEM, as well as time-resolved in situ synchrotron X-ray diffraction. Rietveld refinement was used for quantitative evaluation of relative abundances during phase evolution. The results of ex situ investigations conducted at ambient temperature and near-neutral pH indicate formation of amorphous calcium phosphate, which over the course of experiments transforms to brushite and ultimately hydroxylapatite. The results of in situ X-ray diffraction experiments suggest a more complex pathway of phase development under the same conditions. Some of the initially formed amorphous calcium phosphate and/or crystalline brushite transformed to octacalcium phosphate. In the later stage of the reactions, octacalcium phosphate transforms quite rapidly to hydroxylapatite. This is accompanied or followed by the transformation of the remaining brushite to monetite. Hydroxylapatite and monetite coexist in the sample throughout the remainder of the experiments. In contrast to the near-neutral pH experiments, the results from ex situ and in situ diffraction investigations performed at higher pH yield similar results. The precipitate formed in the initial stages in both types of experiments was identified as amorphous calcium phosphate, which over the course of the reaction quite rapidly transformed to hydroxylapatite without any apparent intermediate phases. This is the first application of time-resolved in situ synchrotron X-ray diffraction to precipitation reactions in the Ca(OH){sub 2}-H{sub 3}PO{sub 4}-H{sub 2}O system. The results indicate that precursors are likely to occur during the natural or induced (e.g., with application of Ca+PO{sub 4} amendments) formation of hydroxylapatite in many sedimentary environments.

54 ENVIRONMENTAL SCIENCES↗

Disentanglement of electron dynamics and space-charge effects in time-resolved photoemission from h-BN/Ni(111)

We observe time-resolved and polarization dependent two-, three-, and four-photon transitions from a Ni(111) surface covered with a monolayer of hexagonal boron nitride. The spectra show features due to transitions involving two unoccupied intermediate states: the n=1 image potential state of Ni(111) and a boron nitride-related interface state. We use these transitions in order to track the effects of space-charge on the spectra in view of pump-probe experiments, at high excitations densities. A simple model is presented, which reproduces the measured energy shifts and broadenings in great detail, allowing the ultrafast dynamics and the space-charge effects to be disentangled. Moreover, owing to the high excitation densities an additional particular three-photon transition via both the interface state and a virtual intermediate state could be measured and identified. The polarization-dependent transient of this transition has successfully been simulated, allowing the lifetime of the involved intermediate state to be extracted from the data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiolytic degradation of n -dodecane: Insights from time resolved pulsed electron radiolysis using aromatic scavengers

This study uses time-resolved picosecond pulsed electron radiolysis and transient absorbance spectroscopy to investigate early radiolytic processes in n-dodecane, a prototypical organic solvent for reprocessing used nuclear fuel (UNF). The primary radical cation, solvated electron, and excited states in neat n-dodecane are formed and consumed on timescales that are difficult to observe directly. Aromatic solutes, biphenyl and benzophenone, were utilized as scavengers to convert these short-lived species into longer-lived, optically detectable transient products to serve as indirect probes of the fraction of the initial n-dodecane radiolytic products that can be intercepted before undergoing ultrafast decay or competing reactions. The transient absorbance spectra of these scavengers and their radiolytic products were analyzed. Results indicate that while biphenyl and benzophenone effectively capture several radiolytic species, they do not fully scavenge all n-dodecane excited states, suggesting potential inefficiencies or additional side reactions. This study provides insight into the formation and accessibility of radiation-induced excited states and charge carriers in n-dodecane, which play a key role in the degradation of solvent extraction systems used in UNF reprocessing.

58 GEOSCIENCES↗

Phase Transitions in Ge-Te Phase Change Materials Studied by Time-resolved X-ray Diffraction

Resistivity versus temperature measurements and time-resolved x-ray diffraction were used to study Ge-Te phase change materials. Resistivity versus temperature measurements showed one sharp drop in resistivity for films with 30, 50, and 70 at.?% Ge, two steps for films with 40 at.?% Ge, and a gradual transition for films with 60 at.?% Ge. Films with 30, 50, and 70 at.?% Ge crystallized in a single-step process with GeTe and Te, only GeTe, and GeTe and Ge diffraction peaks, respectively. Films with 40 and 60 at.?% Ge crystallized in a two-step process with GeTe peaks appearing first and additional Te or Ge peaks, respectively, appearing at higher temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the limits of observing motion in time-resolved X-ray scattering

Limits on the ability of time-resolved X-ray scattering (TRXS) to observe harmonic motion of amplitude, A and frequency, ω 0 , about an equilibrium position, R 0 , are considered. Experimental results from a TRXS experiment at the LINAC Coherent Light Source are compared to classical and quantum theories that demonstrate a fundamental limitation on the ability to observe the amplitude of motion. These comparisons demonstrate dual limits on the spatial resolution through Q max and the temporal resolution through ω max for observing the amplitude of motion. In the limit where ωmax ≈ ω 0 , the smallest observable amplitude of motion is A = 2π/Q max . In the limit where ω max ≥2ω 0 , A≤2π/Q max is observable provided there are sufficient statistics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time resolved measurements in a low aspect ratio transonic compressor stage

The time resolved flowfield in a low aspect ratio transonic compressor stage has been studied using a high frequency response sphere probe with a bandpass of D.C. to 20 kHz in a blowdown compressor facility. Averaged over the compressor annulus, the data agree well with those measured with standard pitot type probes on the same stage in a conventional test rig. Not all the spanwise distributions agree, however. These differences are explained as errors in the pitot probe readings due to fluctuations in the flow. The experimental data are compared to the results of a three-dimensional inviscid Euler calculation.

Epstein, A. H.↗

Combined, time-resolved, in situ neutron reflectometry and X-ray diffraction analysis of dynamic SEI formation during electrochemical N 2 reduction

One means of improving performance for electrochemical ammonia production through the Li-mediated N 2 reduction reaction (Li-NRR) is by cycling the current driving the reaction between open-circuit conditions and periods of applied current density. Herein, we have investigated the dynamics of the electrode–electrolyte interface under Li-NRR conditions during current cycling using in situ time-resolved neutron reflectometry and grazing-incidence synchrotron X-ray diffraction. During cycling, measured neutron reflectivity curves indicated bilayer formation in which Li-containing species such as LiOH, Li 2 O, and small quantities of Li 3 N and metallic Li primarily appeared in a thin layer at the cathode surface, above which formed a much larger, porous, ‘solid–electrolyte interface’ (SEI) layer. Upon return to open-circuit conditions, Li-containing species quickly moved out of the thin layer, leaving a compact, stable layer of decomposition products underneath the SEI layer. This SEI layer concomitantly filled with electrolyte or dissolved, becoming indistinguishable from the electrolyte via contrast in scattering-length density (SLD). During the second current cycle, Li-containing species again preferentially deposited directly atop the cathode, with the thick SEI-like layer again appearing within a minute. This SEI layer exhibited a lower SLD more quickly than in the first cycle, which might suggest that Li-containing species become distributed within the porous SEI layer. Furthermore, these time-resolved observations of SEI and plated layers during current cycling suggest that benefits associated with return to open-circuit conditions between periods of applied current density may be related to the concomitant loss of Li-containing species from a thin layer at the cathode surface into a porous SEI layer that becomes filled with electrolyte or dissolves.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation App for Time-Resolved Photoluminescence in Thin-Film Solar Cells

We develop a COMSOL Multiphysics-based model and application, or "app", for time-resolved photoluminescence (TRPL) measurements in thin-film solar cells. TRPL is commonly used to measure recombination in thin-film solar cells. However, simulations show that decay times extracted from TRPL data are not, in general, equal to the Shockley-Read-Hall lifetime parameter set in the model. Here, we present a model and app, using graded CdSe y Te 1-y solar cells as an example, that can be used to study impacts of a range of potentially important material and measurement parameters on TRPL results.

minority-carrier lifetime↗