Behind the Meter Solar+Storage: Market data and trends [Slides]

As the distributed solar market evolves toward more dynamic forms of deployment, interest in paired solar-plus-storage applications continues to gain steam, but details on the current state of the market are relatively sparse. To fill that void, Berkeley Lab has released an in-depth analysis of this budding market segment. This report draws on the Lab’s Tracking the Sun dataset to characterize trends in deployment, system sizing and equipment selection, installer-market development, and system pricing. The report also provides indicative analyses of the financial and resilience value that host customers in several key markets presently receive by pairing storage with solar.

14 SOLAR ENERGY↗

Integrated Framework of Multisource Data Fusion for Outage Location in Looped Distribution Systems

Accurate outage location is essential for expediting post-outage power restoration, minimizing outage duration, and enhancing the resilience of distribution networks. With the advent of advanced metering infrastructure, data-driven outage location methods have significantly advanced beyond traditional approaches that rely on manual inspections. However, existing methods still face critical challenges, like reliance on single-source data, limited ability to handle partially observable systems or difficulties with loop networks. To the best of our knowledge, no single approach has comprehensively addressed all of these challenges at once. To this end, this paper proposes a comprehensive multisource data fusion framework for outage locations via probabilistic graph networks. The framework consists of three key phases. First, a novel method for reconstituting distribution networks with loops is developed, transforming looped networks into multiple radial subnetworks that retain all outage causalities of the original network. Second, Bayesian network (BN) models are established for each subnetwork, integrating multiple data sources and network structures. Finally, a joint Gibbs sampling mechanism, featuring forward and backward information flow, is designed to merge data from separate BN models and maximize the utilization of limited evidence, ensuring accurate outage location identification. In conclusion, the framework was validated on two modified public test systems, and comparative studies confirmed its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reference Site Condition Datasets for Floating Wind Arrays in the United States

Floating offshore wind farm design is highly site-specific, requiring detailed information about the specific conditions of a project area for realistic design studies. Unfortunately, publicly available site condition data for potential floating offshore wind project sites in the United States is scarce. To support U.S. offshore wind research, we developed reference site condition datasets, including metocean and seabed information, for four potential floating wind project areas in the U.S.: Humboldt Bay, Morro Bay, the Gulf of Maine, and the Gulf of Mexico. These datasets were compiled using publicly available data. Our metocean analysis, covering wind, waves, and surface currents, utilized measurement data from 2000 to 2020. Sources included the National Renewable Energy Laboratory’s National Offshore Wind Dataset for wind data, National Data Buoy Center buoys for wave data, and the High Frequency Radar Network for surface currents. These data were integrated into hourly time series used to compute extreme return periods up to 500 years, monthly statistics, and joint probability clusters for fatigue analysis. Soil conditions were evaluated using the usSEABED database and bathymetry grids were interpolated from the NCEI Digital Elevation Model Global Mosaic. Further information on the datasets and how they were created can be found in: Biglu, M., M. Hall, E. Lozon, S. Housner. 2024. Reference Site Conditions for Floating Wind Arrays in the United States. Golden, CO: National Renewable Energy Laboratory (NREL). NREL/TP-5000-89897. The data are also available at: https://github.com/FloatingArrayDesign/SiteConditions The content of each dataset is as follows: _NOW23_wind.txt: Hourly NOW-23 wind data up to a height of 400 meter. _metocean_1hr.txt: Hourly time series including wind, wave, surface current and temperature data. _Summary.xlsx: Metocean data, including extreme values, joint probability distributions and monthly statistics. _usSEABED_soil.csv: Extract of the usSEABED database for this specific site. _bathymetry_200m.txt (and 500m, 1000m): Gridded seabed depth data.

16 TIDAL AND WAVE POWER↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Solar Energy Extension Project

The town of Stratford plans to develop and own a 6 kilowatt (kW) solar array on the roof of a municipal-owned public pavilion on the town green. A SolarEdge level 2 EV charging station will be installed at the pavilion to be used by the public. The charging station will have one charging port. The town will install 3 air source heat pumps in the library located adjacent to the pavilion to reduce the use of propane to heat the library. The town will install 4 air source heat pumps in the Town Hall to reduce the use of #2 heating oil to heat the facility. The 6 kW solar array will provide electricity to the library to offset electricity usage, and when an EV plugs into the charging station the solar will provide electricity to the charging station. There is no ground disturbance or ground trenching associated with this project. The 6 kW solar array on the roof of the pavilion will include 20 (390) watt all black panels. A SolarEdge level 2 EV charger will be installed at the pavilion with the 240 V inverter. The solar array will provide electricity to the library and when a vehicle plugs into the EV charger the solar array will switch to power the charger. Any excess electricity that is generated by the array and not used by the library or the EV charger will be fed onto the grid and the town will receive a net metering credit applied towards future consumption. There is no ground disturbance associated with the EV charger or solar array, and the town will install signage to direct the public to the charger. The library will install 2 (18,000) BTU ductless air source heat pumps and 1 (24,000) BTU unit. This will significantly reduce the amount of propane required to heat the library. The Town Hall will install 2 (36,000) BTU ductless air source heat pumps and 2 (9,000) BTU units to reduce the amount of #2 heating oil required to heat the building.

14 SOLAR ENERGY↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distribution System Research Roadmap; Energy Efficiency and Renewable Energy

The scope of the U.S. Department of Energy's Energy Efficiency and Renewable Energy (EERE) office covers a number of distributed energy resource (DER) technologies, including distributed photovoltaics, smart buildings, wind, water, behind-the-meter-storage, and electric vehicles. The impact of these technologies on the distribution system is often assessed with an individual technology focus. Similarly, different technology offices often leverage different sets of tools, leading to analyses that are not comparable. EERE sought the ability to assess the impact of integrating multiple DER technologies, and to comprehensively address DER integration challenges across the portfolio of EERE technologies. This project built on existing work understanding technical challenges, mapped out the key research questions, assessed relevant capabilities across the national laboratory network, identified key gaps, and produced a research roadmap to inform EERE investment decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests

The hot box test method has been applied to evaluate both the steady-state (U-value) and dynamic thermal properties of building envelopes. However, the high construction cost of full-scale hot box apparatus and the testing time required (usually several days) may prevent its wider adoption. To overcome the limitations of full-scale hot box tests, here we propose a novel method to evaluate the dynamic thermal performance of building envelope components using a small-scale calibrated hot box and scaled-down specimen. In this paper, the scaling relationships of thermal properties evaluated using a full-size specimen and a scaled-down specimen are established based on the Laplace transform of the heat transfer equations. In addition, dynamic thermal properties obtained from scaled-down experimental tests are compared to the values calculated by the EN ISO13768 (ISO) method. A small-scale hot box with a 355 mm × 355 mm metering area was constructed and calibrated to validate the correlations. Three scaled-down concrete sandwich wall panels were then tested and the scaling relationship was cross-validated using the experimental results, finite difference (FD) simulations, and the ISO method. The results indicate that the dynamic thermal properties obtained from a scaled-down hot box test can be correlated to its full-size counterpart when certain conditions are met. The scaled-down hot box test is demonstrated to be an effective yet economical alternative to a full-scale test with significantly reduced experimentation cost and turn-around time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of swinging door lossy compression of synchrophasor data

As the number of operational Phasor Measurement Units (PMUs) is increasing, compression is becoming crucial for efficiently transferring and storing enormous amount of synchrophasor data continuously measured from a power system. Some utilities in the U.S. have already adopted a nonlinear compression technique, called Swinging Door Algorithm (SDA), assuming compressed data meets technical and regulatory requirements without resulting in any degradation of the measurements. This paper studies impacts of this compression algorithm on field measured and simulated PMU data, and presents results from spectral analyses of raw and decompressed measurements. The results show blind application of the SDA compression alters frequency content in the measurements and introduces false harmonics and aliasing. These can lead to false conclusions being drawn from the measurements about the power system condition.

42 ENGINEERING↗

Impact of Electrode Thickness and Temperature on the Rate Capability of Li 4 Ti 5 O 12 /LiMn 2 O 4 Cells

Growing demand for stationary energy storage systems requires the development of low cost, long cycle life, safe batteries. Lithium-ion batteries (LiBs) utilizing Li 4 Ti 5 O 12 /LiMn 2 O 4 (LMO) cathode are promising candidates providing critical-material-free chemistry, high power capability, and long lifespan. However, their low energy density is a major drawback. In this work, we evaluate the rate performance of LTO/LMO cells fabricated with electrode loadings from 1.7 to 4.2 mAh cm -2 toward the development of high energy density and low cost LTO/LMO cells. The operating temperature is varied from 30 °C to 55 °C to evaluate the impact of electrode thickness vs temperature limitations on the electrode utilization. In addition, Newman modeling is performed to provide detailed understandings of the cell performance. Combining experimental and simulated results, we show the rate capability of the thicker electrodes is limited by the electrolyte transport. When the cells are discharged by applying pulsed current, Li + ion depletion is mitigated and the discharge capacity increases. Thus, high energy density LTO/LMO cells for BTMS applications can operate more efficiently when intermittent rest is applied. Finally, overcoming electrolyte transport limitations will be the key to enabling the development of high energy density LTO/LMO cells using thick electrodes.

25 ENERGY STORAGE↗

Data-driven evaluation of HVAC operation and savings in commercial buildings

Commercial buildings consumed 36% of electricity, or 1.35 trillion kWh, in the United States in 2017, and almost 30% of this energy was wasted. Much of this loss can be attributed to inefficient heating ventilation and air con­ditioning (HVAC) systems. By improving the operational conditions of HVAC, significant savings can be achieved. However, most buildings and building equipment do not use costly sub-meters to monitor and address performance issues, and on-site auditing can be expensive and insufficient. Alternatively in this study, we propose a data-driven method to identify savings opportunities using only whole building meter data and without setting foot in the building. For this purpose, we introduced two algorithms that virtually quantify the value of a thermostat setpoint setback and HVAC rescheduling. Additionally, we developed novel methods for detecting occupancy patterns and quantifying the baseload of the HVAC operation. Using a clustering algorithm, we identified those buildings for which HVAC savings was significant and further categorized the buildings based on their potential for savings. A population study of over 432 commercial buildings demonstrated a median percentage energy savings of 1.6% from a baseload reduction and 2.1% from HVAC rescheduling. Additionally, results indicate that retail buildings have the highest potential for savings among the building types studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Enhancing Performance Contracts with Monitoring-Based Commissioning (MBCx)

Integrating monitoring-based commissioning (MBCx) software tools into performance contracts is a timely topic given recent developments in MBCx software offerings and the growing number of MBCx deployments nationwide. Many commercial building owners have started to install MBCx software tools that tie in advanced metering infrastructure, building automation systems, and local weather data to enable ongoing commissioning and identify energy conservation measures. To support federal and commercial building owners in understanding, procuring, and implementing MBCx software tools, this report provides an overview of their capabilities, the MBCx process, and how MBCx can be integrated into - and benefit - each phase of a performance contract. This report is intended to spur increased use of MBCx in performance contracts, whether an agency has previously installed or is considering adding MBCx at the time of their project. Additionally, case studies illustrate successful experiences using MBCx within performance contracts at a university campus and across a large number of buildings managed by the General Services Administration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗